• Title/Summary/Keyword: Plant Maintenance

Search Result 921, Processing Time 0.027 seconds

A Study on Reasonable Improvement of Legal Requirement for Fire Proofing for Steel Structures in a Chemical Plant (화학플랜트에서 철골구조물 내화기준의 합리적인 개선에 관한 연구)

  • Hwang, Soon-Yong;Char, Soon-Chul;Kang, Kyung-Sik
    • Journal of the Korea Safety Management & Science
    • /
    • v.9 no.1
    • /
    • pp.51-63
    • /
    • 2007
  • It is noted that the disaster such as fire, explosion, collapse has been rapidly increased caused by strength deterioration of steel structures at petrochemical plant during fire. In this regard, it is stressed out that the legal requirement for fire proofing for steel structures at petrochemical plant should be carefully reviewed since the current legal requirement such as Industrial Safety & Health Law, Architectural Law has a conflict and different way of approach. In addition, it is our point of view that the present law should be revised to consolidate into single law including engineering design criteria to reflect unreasonable legal requirement. It is further our point of view that the performance certificate for fire proofing like UL-1709, basis of maintenance should be appropriately and reasonably provided in line with global practice.

A Thesis of Design Air Operated Valve Actuator in Nuclear Power Plant (원자력 발전소 AOV 구동기 설계 정립화)

  • Choi, J.K.;Hwang, J.H.;Kim, Y.B.;Son, K.Ch.
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2616-2620
    • /
    • 2008
  • AOV used fluid capacity and fluid pressure control in nuclear power plant with heating power plant. AOV structures safely must be secured the reliability and a safety of the atomic power plant. but, AOV where is used from domestic is using the product of the overseas enterprise. The AOV design and maintenance technique is insufficient. Therefore According to ASME designed AOV, The performance test resultant fluid leakage did not occur and AOV design was satisfactory.

  • PDF

A Research and Analysis on the Actual Condition of Safety Management at Small-Medium Chemical Plant (중소기업 화학 사업장의 안전관리 실태 조사 분석)

  • 이태우;강경식
    • Proceedings of the Safety Management and Science Conference
    • /
    • 1999.11a
    • /
    • pp.97-108
    • /
    • 1999
  • Most of chemical plant are using toxic and dangerous materials, inflammable and poisonous. There are many accidental dangers by escaping of fire, explosive and poisonous materials in case of high temperature and pressure. The accidents lead to taking employer's and local people's life and environmental contamination. Therefore, 27 small-medium chemical plant, which size is 30∼200 employees out of safety management agent in the area of A was selected in this study. The problems of safety management and several countermeasures at the chemical plants was indicated through the analyzed data. Prior to this analysis, top managers' concerns, equipment maintenance for the safety management are needed. For the future, calamity prevention countermeasures by industrial disaster analysis are needed and active safety management programs are investigated for the industrial disaster prevention and productivity enhancement at the chemical plant.

  • PDF

Competitive Effects of Annual Weeds on Soybeans. II. Effect of Weed-free Maintenance Period on the Growth and Yield of Soybeans. (대두의 일년생잡조와의 경합에 관한 연구 II. 잡초방제기간의 차이가 대두의 생육 및 수량에 미치는 영향)

  • Jong-Yeong Pyon;Young-Rae Kim
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.23 no.2
    • /
    • pp.150-153
    • /
    • 1978
  • A study was conducted to determine the critical period of weed-free maintenance required to produce maximum soybean yields. Leaf area index(LAI). crop growth rate (CGR), and number of pods per plant were increased with extended weed-free maintenance period. Consequently, maximum soybean yields were obtained when weeds were controlled for more than six weeks, but a relatively high level of ;soybean production was attained with only two weeks of weed free maintenance.

  • PDF

A Investment on Wire-wireless Communication Method for Electrical Device Infrastructure Maintenance (전력설비 관리를 위한 무선 및 유선 통신 방법에 관한 고찰)

  • Kim, Young-Eok;Lee, Jin
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.2
    • /
    • pp.354-359
    • /
    • 2016
  • Power plants maintenance data is to be sent to management server system via a communication network. In this case, reliable communication network is required. Transmission of the power plants maintenance data is used in the wired communication network or wireless communication network. PLC communication network is a kind of wired communication network. However PLC communication network is easily affected by noise. On the vulnerable areas in power line system, such as a mountain or rural areas, it is difficult to form a power line communication network. For a wireless communication, environment are also influenced factors in wireless communication. Harsh environmental factors are bring the communication characteristic degradation. In such areas it can be used a combination of two networks and in this way the complementary function can be achieved. Power plants are distributed in various regions across the country. The appropriate communication network is needed to maintain the power plant.This study investigated the effect of environment on the wired communication and wireless communication. It would examine a variable factor which is affect to the communication characteristic. We used PLC communication for wired communication network and ZigBee communication for wireless communication network. We investigated the characteristics of a single communication network and it raised the need for a complex communication technology to complement a single communication network.

Improving the Efficiency of Cybersecurity Risk Analysis Methods for Nuclear Power Plant Control Systems (원전 제어시스템 사이버보안 위험 분석방법의 효율성 개선)

  • Shin-woo Lee;Jung-hee Lee
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.34 no.3
    • /
    • pp.537-552
    • /
    • 2024
  • Domestic nuclear power plants operate under the establishment of the "Information System Security Regulations" in accordance with the Nuclear Safety Act, introducing and implementing a cybersecurity system that encompasses organizational structure as well as technical, operational, and managerial security measures for assets. Despite attempts such as phased approaches and alternative measures for physical protection systems, the reduction in managed items has not been achieved, leading to an increased burden on security capabilities due to limited manpower at the site. In the main text, an analysis is conducted on Type A1 assets performing nuclear safety functions using Maintenance Rules (MR) and EPRI Technical Assessment Methodology (TAM) from both a maintenance perspective and considering device characteristics. Through this analysis, approaches to re-evaluate the impact of cyber intrusions on asset functionality are proposed.

Research on the on-site Seat Test Technology for the nuclear safety related valves (원전용 안전등급 밸브의 현장 폐쇄기밀시험 기술에 대한 연구)

  • Jung Hwan Seok;Kim Tae Sung
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.17 no.1
    • /
    • pp.8-17
    • /
    • 2021
  • The seat leakage test is required after the maintenance work on the valve seat. Either the test has been performed outside of the plant after cutting the valve from the pipe system or the simplified test has been performed so far. It was unable to perform the test at the plant site because it is hard to make a steady pressure on the valve inlet when it is installed in the pipe. This research aims to perform the leakage test in the nuclear power plant while it is installed in the pipe system. The mock-up test is performed by pressurizing the leak-off pipe on the valve body. The result is compared with traditional test result by pressurizing the valve inlet. Furthermore the chamber mock-up tests are performed under various conditions. The leak rate by the developed test using the leak-off pipe is found to be similar but greater than the leak rate by the existing test method. It implies that the test using the leak-off pipe is more conservative than the existing test. The methodology and the equipment which this paper suggests that on-site seat test is possible and the application of the technology could reduce the time and cost for the valve maintenance work significantly.

Chloride Penetration Analysis of Fly Ash Concrete using Potentiometric Titration and XRF (플라이애시를 혼입한 콘크리트의 전위차 적정법과 XRF를 이용한 염화물 침투 분석 )

  • Eun-A Seo;Ji-Hyun Kim;Ho-Jae Lee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.5
    • /
    • pp.16-22
    • /
    • 2023
  • In this study, a salt water immersion test was performed on concrete specimens simulating the concrete mix design of the nuclear power plant, and the correlation between the amount of chloride and the XRF component according to the depth of the concrete was analyzed. The amount of chloride on the surface of the nuclear power plant concrete increased slightly with increasing immersion time in salt water, but the amount of chloride in the depth of 5.5 mm or more showed a clear tendency to increase with increasing immersion time in salt water. As a result of analyzing the correlation between the amount of chloride in concrete and the XRF component, the concrete with 20% FA substitution compared with the OPC concrete showed a very high correlation between the composition ratio of Cl ions and the evaluation result of salt damage resistance by XRF component analysis. Accordingly, it was confirmed that chlorine ion analysis and salt damage resistance performance evaluation by XRF component analysis were possible through repeated data accumulation in the nuclear power plant concrete mix with 20% fly ash replacement.

Estimation of the Energy Saving Potential using Energy Bandwidth Analysis in Manufacturing Plant (에너지 대역분석 기법을 이용한 생산플랜트에서 에너지절감 잠재량 산정)

  • Park, Hyung-Joon;Shon, Jin-Geun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.60 no.4
    • /
    • pp.236-240
    • /
    • 2011
  • Currently one of the most importance issues in industrial sector is energy cost and energy efficiency. The manufacturing plants especially have made many efforts to reduce energy cost by implementing maintenances. But in many cases, they are not aware that how much energy could be saved more. If we know the best energy consumption, which signifies energy baseline, we can control the intensity of maintenances. One way to obtain the baseline is using proper statistics from a specific plant, a sector of industry. Energy bandwidth signifies the gap between actual Specific Energy Consumption(SEC) of a certain plant and minimum SEC of the best plant, and estimate energy saving potential(ESP) is a result of bandwidth analysis. We chose a model plant and implemented some maintenance for a year, and then we obtained ESP. Additionally we could determine the decreased amount of carbon emissions from the plant using Carbon Emissions Factor(CEF) by Intergovernmental Panel on Climate Change(IPCC).

Arabidopsis SIZ1 positively regulates alternative respiratory bypass pathways

  • Park, Bong-Soo;Kim, Sung-Il;Song, Jong-Tae;Seo, Hak-Soo
    • BMB Reports
    • /
    • v.45 no.6
    • /
    • pp.342-347
    • /
    • 2012
  • Plant mitochondria possess alternative respiratory pathways mediated by the type II NAD(P)H dehydrogenases and alternative oxidases. Here, E3 SUMO ligase was shown to regulate alternative respiratory pathways and to participate in the maintenance of carbon and nitrogen balance in Arabidopsis. The transcript abundance of the type II NAD(P)H dehydrogenases NDA2 and NDB2 and alternative oxidases AOX1a and AOX1d genes was low in siz1-2 mutants compared to that in wild-type. The addition of nitrate or ammonium resulted in a decrease or an increase in the expression of the same gene families, respectively, in both wild-type and siz1-2 mutants. The amount of free sugar (glucose, fructose and sucrose) was lower in siz1-2 mutants than that in wild-type. These results indicate that low nitrate reductase activity due to the AtSIZ1 mutation is correlated with an overall decrease in alternative respiration and with a low carbohydrate content to maintain the carbon to nitrogen ratio in siz1-2 mutants.