• Title/Summary/Keyword: Plant Efficiency

Search Result 2,828, Processing Time 0.032 seconds

Effect of sewage flow on treatment efficiency of small scale wastewater treatment plant in rural community (농촌 지역에서 유입 유량이 소규모 하수처리장 처리 효율에 미치는 영향)

  • Im, Jiyeol;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.18 no.3
    • /
    • pp.267-274
    • /
    • 2016
  • Sewerage supply in rural community is the important for water quality protection of water system such as river, lake and wetland. And characteristic of small scale wastewater system that have wide range of inflow and concentration in sewage should be considered for stable operation of small scale wastewater treatment plant. In this research, characteristics of flow ratio (flow / designed flow), effect on treatment efficiency of small scale wastewater treatment plant and assessment of optimal flow ratio were conducted through analysis on operation result of 18 small scale wastewater treatment plant in Bong-hwa gun. As a result, flow ratio shows the higher value during summer. However pollutants concentration in sewage was shown the higher concentration during autumn and winter. Treatment of small scale wastewater treatment plant is increased when flow ratio increased, and nutrient treatment efficiency is more sensitive to change of flow ratio than organic compound and suspended solids. According to this research result, it need to be maintained flow ratio 0.8 over value for stable treatment efficiency of small scale wastewater treatment plant.

A study on Design of Plant Safety Evaluation for Increasing Productivity (생산성향상을 위한 설비안전평가 시스템 설계)

  • Yang, Gwang-Mo;Seo, Jang-Hun;Jo, Yong-Uk;Lee, Gong-Seop
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2008.04a
    • /
    • pp.339-344
    • /
    • 2008
  • This study's purpose centers plant management activities that is management system for total plant efficiency's maximization, plant evaluation system that production and safety management activities factor that is enforcing in manufacturing industry can develop evaluation model that can evaluate quantitative activities in process that maximize productivity and safety efficiency wishes to do design.

  • PDF

Evaluation on the Expected Purification Efficiency of Air Ion and Analysis on the Generated Amount of Negative Air Ions by Plants for the Purification of Particulate Matter in Air (지표대기 미세먼지 정화를 위한 식물체 음이온 발생량 분석 및 음이온의 미세먼지 기대정화지수 평가)

  • Oh, Deuk-Kyun;Ju, Jin-Hee
    • Journal of Environmental Science International
    • /
    • v.29 no.6
    • /
    • pp.623-631
    • /
    • 2020
  • This study analyzes the effect of negative air ions on the concentration of airborne particulate matter and evaluates the expected purification efficiency of open spaces for particulate matter by investigating the amount of negative air ions generated by plants. This study establishes a negative air ion generation treatment environment, plant environment, and control environment to measure the purification efficiency of particulate matter under the conditions of each, analyzing the expected purification efficiency by designing a particulate matter purification model. Results show that the amount of generated negative air ion according to environment was negative air ion generation treatment environment > plant environment > control environment; this order also applies to the particulate matter purification efficiency. Moreover, it took 65 min for the negative ion generation treatment environment, 90 min for the plant environment, and 240 min for the control environment to reach the standard expected purification efficiency of particulate matter concentration of 960 mg/㎥ for PM10. For PM2.5, with the designated maximum concentration of 700 mg/㎥, it took 60 min for the negative ion generation treatment environment, 80 min for the plant environment, and more than 240 min for the control environment. Based on these results, the expected purification efficiency compared to the control environment was quadrupled in the negative ion generation treatment environment and tripled in the plant environment on average.

A Study on the Development of Analytic Hierarchy Process Plant Evaluation System for Safety Management (안전관리를 위한 AHP 설비 평가시스템 개발에 관한 연구)

  • Yun, Yeo-Kwon;Cho, Young-Wook;Yang, Kwang-Mo
    • Journal of the Korea Safety Management & Science
    • /
    • v.14 no.3
    • /
    • pp.127-134
    • /
    • 2012
  • Plant safety management that is enforcing introducing more than 95% in domestic manufacturing industry is using total plant efficiency by the evaluation index, and as a result, can see a lot of examples that plant productivity, economy and safety is increased. The efficient safety estimation for a business should analyze an accident data by considering every possible and potential factor. This study's purpose centers plant safety management activities that is management system for plant production and safety efficiency's maximization, plant evaluation system that plant safety management activities factor(reliability, maitainability, safety, service quality) that is enforcing in manufacturing industry can develop evaluation model that can evaluate qualitative activities by quantitative activities in process that maximize plant safety management wishes to do design.

Performance Analysis of Supercritical Coal Fired Power Plant Using gCCS Simulator

  • Tumsa, Tefera Zelalem;Mun, Tae-Young;Lee, Uendo;Yang, Won
    • 한국연소학회:학술대회논문집
    • /
    • 2014.11a
    • /
    • pp.37-40
    • /
    • 2014
  • Capturing the carbon dioxide emitted from coal-fired power plants will be necessary if targeted reduction in carbon emissions is to be achieved. Modelling and simulation are the base for optimal operation and control in thermal power plant and also play an important role in energy savings. This study aims to analyze the performance of supercritical coal fired power plant through steady and dynamic simulation using a commercial software gCCS. A whole power plant has been modeled and validated with design data of 500 MWe power plant, base and part load operations of the plant were also evaluated, consequently it had been proven that the simulated result had a good agreement with actual operating data. In addition, the effect of co-firng on the plant efficiency and flue gases were investigated using gCCS simulator.

  • PDF

Analysis of the Virtual Power Plant Model Based on the Use of Emergency Generators in South Korea

  • Chung, Beom Jin;Kim, Chang Seob;Son, Sung-Yong
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.1
    • /
    • pp.38-46
    • /
    • 2016
  • This study analyzes the economic efficiency of the virtual power plant (VPP) model that aims to integrate a number of emergency generators installed at the consumer end and operate them as a single power plant. Several factors such as the demand response benefits from VPP operation and costs incurred for converting emergency generators into VPP are considered to assess the economic efficiency of the proposed VPP model. Scenarios for yearly VPP conversion are prepared based on the installed capacities of the emergency generators distributed in South Korea, while the costs and benefits are calculated from the viewpoints of participants and power companies in accordance with California Test Methods. Furthermore, a sensitivity analysis is conducted on the cost factors among those affecting the economic efficiency of VPP business because these two factors have a great impact on benefits.

Preparation of Composite Adsorbents by Activation of Water Plant Sludge and Phenolic Resin Mixtures

  • Myung, Heung-Sik;Kim, Dong-Pyo
    • Carbon letters
    • /
    • v.1 no.3_4
    • /
    • pp.154-157
    • /
    • 2001
  • Composite adsorbents were prepared by mixing water plant sludge with phenolic resin having the ratio of 1 : 1, 1 : 2, and 1 : 3 respectively, curing from $100^{\circ}C$ to $170^{\circ}C$ under $N_2$ atmosphere, and then activating with $N_2$ at $700^{\circ}C$. Thermal property, specific surface area and morphology of the composite adsorbents as well as their precursors were measured by TGA, BET and SEM respectively. Removal efficiency of the composite adsorbents to ${NH_4}^+$ and TOC was compared with those of commercial zeolite and activated carbon. The adsorbents presented very promising TOC removal efficiency of 98%, which was identical level to that of commercial activated carbon while they displayed removal efficiency, only 32%, of ${NH_4}^+$. Therefore, this composite adsorbent considered as the alternative material of commercial activated carbon, used as an expensive removal agent of organic substances and THM in water treatment plant and it also suggested a possibility of practical application in other processes.

  • PDF

Implementation of Performance Monitoring System for Thermal Power Plant in SIEMENS DCS (SIEMENS DCS 환경에서 화력발전소 성능감시 시스템 구현)

  • 김승민;문태선;조창호
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.37-37
    • /
    • 2000
  • This paper introduces the Performance Monitoring System(PMS) in a thermal power plant. The purpose of the PMS is to offer the operator current performance information of plant which could be an index of plant status or information to improve plant efficiency. The PMS of Bukcheju thermal power plant unit #2&3 is implemented under the SIEMENS DCS which supplies about 150 function blocks for performance calculation and all measured signals. The performance of unit, boiler, turbines, feedwater heaters, condenser, airpreheaters, feedwater pumps will be monitored and updated for every 5 minutes in PMS of Bukcheju TPP.

  • PDF

Performance Evaluation of the Samcheonpo Small-Hydro Power Plant (삼천포 해양소수력 성능평가)

  • Cho, Hong-Yeon;Cho, Beom-Jun;Kang, Geum-Seok
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.617-620
    • /
    • 2007
  • The performance evaluation of the Samcheonpo small-hydropower plant constructed on the October 25th,2006, was carried out focused on the turbine and generator efficiency analysis by using the measurement data. The unreasonable and unrealistic efficiency results are occurred in some periods because of the data variability, uncertainty, and measurement errors and mistakes. Whereas, the big mismatch is the tidal elevation predicted in the design processes. The difference between the measured and estimated tidal elevation is obvious during the low water period. It should be considered and checked in depth on the efficiency analysis of the planned and constructing small-hydro power plants in other coastal areas.

  • PDF

Efficiency Verification of Small-Scale Sewage Treatment Plant Using Discussed Vinyl as Biofilm Media (폐비닐 재활용 여재를 이용한 소규모 오수종말처리장의 효율검증)

  • Rim, Jay-Myoung;Kim, Byoung-Ug;Koo, Bon-Soo
    • Journal of Industrial Technology
    • /
    • v.18
    • /
    • pp.1-6
    • /
    • 1998
  • This study was conducted to use disused vinyl as biofilm for biological sewage treatment. Efficiency verification was performed on laboratory and on-site plant. In laboratory study, total biochemical oxygen demand(TBOD) removal rate was ranged 94.8~97 % in each hydraulic retention tim(HRT), 12, 16, 20, 24 hr, respectively. At that time, filling rate was 50 %. And effluent TBOD concentration was low ranged 3.64~6.28 mg/L. In on-site plant, TBOD removal rate was ranged 88.2~96.8 % and effluent TBOD concentration was 4.8~17.7mg/L. This concentration was lower than disign effluent concentration, 30mg/L. Total kjeldhal nitrogen(TKN) removal efficiency was ranged 56.8~90.9%. This was resulted higher than Lab. scale treatment efficiency.

  • PDF