• Title/Summary/Keyword: Planning directions

Search Result 569, Processing Time 0.03 seconds

Comparative Study of Institutional Approaches to Children's Playgrounds for Ensuring the Right to Play (놀이권 보장 측면에서 본 국내외 어린이놀이터 관련 법제 비교 연구)

  • Song, Yun-Jeong;Lee, Sang-Min;Kang, Hyunmi;Kim, Suin
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.51 no.6
    • /
    • pp.33-45
    • /
    • 2023
  • The importance of play from a Children's Rights perspective has been continuously emphasized, and the need for play facilities and spaces has been reiterated. Meanwhile, in South Korea, despite the continuous increase in the number of play facilities, efforts to improve children's play spaces are required. Therefore, this study reevaluated the current regulations and policies concerning play and play spaces from the perspective of securing the right to play. An analysis of the legal concept of domestic playgrounds, related laws, construction standards, and regulations was conducted. The systems and characteristics of the related regulations in the UK, Canada, and Germany were analyzed. Based on the results of the comparative analysis, our directions for improving the system of playgrounds to ensure the children's right to play were proposed. First, a legal definition of the concept and scope of playgrounds should be established. Second, beyond safety-focused facility regulations, there is a need for institutional enhancements to ensure the right to play. Third, comprehensive management of playgrounds is required as a spatial concept rather than as individual facilities. Fourth, qualitative management is needed through specific guidelines and guidelines related to the establishment of playgrounds. These results can serve as a basis for establishing systems and promoting policy projects to ensure children's right to play in various fields, including urban planning, child welfare, and education in the future.

Analysis of Users' Sentiments and Needs for ChatGPT through Social Media on Reddit (Reddit 소셜미디어를 활용한 ChatGPT에 대한 사용자의 감정 및 요구 분석)

  • Hye-In Na;Byeong-Hee Lee
    • Journal of Internet Computing and Services
    • /
    • v.25 no.2
    • /
    • pp.79-92
    • /
    • 2024
  • ChatGPT, as a representative chatbot leveraging generative artificial intelligence technology, is used valuable not only in scientific and technological domains but also across diverse sectors such as society, economy, industry, and culture. This study conducts an explorative analysis of user sentiments and needs for ChatGPT by examining global social media discourse on Reddit. We collected 10,796 comments on Reddit from December 2022 to August 2023 and then employed keyword analysis, sentiment analysis, and need-mining-based topic modeling to derive insights. The analysis reveals several key findings. The most frequently mentioned term in ChatGPT-related comments is "time," indicative of users' emphasis on prompt responses, time efficiency, and enhanced productivity. Users express sentiments of trust and anticipation in ChatGPT, yet simultaneously articulate concerns and frustrations regarding its societal impact, including fears and anger. In addition, the topic modeling analysis identifies 14 topics, shedding light on potential user needs. Notably, users exhibit a keen interest in the educational applications of ChatGPT and its societal implications. Moreover, our investigation uncovers various user-driven topics related to ChatGPT, encompassing language models, jobs, information retrieval, healthcare applications, services, gaming, regulations, energy, and ethical concerns. In conclusion, this analysis provides insights into user perspectives, emphasizing the significance of understanding and addressing user needs. The identified application directions offer valuable guidance for enhancing existing products and services or planning the development of new service platforms.

A Comparative Study on Enhancing the Function of the Health Center in a Urban Area (도시지역 한 보건소 기능 강화 방안에 대한 의견 비교 분석)

  • Lee, Weon-Young;Shin, Young-Jeon;Kwon, Young-Jun;Choi, Bo-Youl;Moon, Ok-Ryun;Jeon, Hye-Jeong
    • Journal of Preventive Medicine and Public Health
    • /
    • v.31 no.4 s.63
    • /
    • pp.857-874
    • /
    • 1998
  • The objective of this study is to collect the opinions on the present condition and the improvement directions of urban health centers from and to make a comparison. Samples were drawn from the various sources of a district in seoul. 53 persons involved in district health's administration(the Members of a District Parliament, the senior officials of a District office, village chief) and 84 health center workers were surveyed with anonymous postal questionaires and 427 district private medical personnels with postal questionaires and 625 users of a health center with direct questionaires, from November 18 to 25, 1996. Additionally, 12,151 households were surveyed with self-reported questionaires including priorities on special district health services of health center, from September 1 to 7, 1996. The major findings were as follows : 1) Although the persons involved in district health administration tend to put lower priority on health service over other community activities, they well acknowledged the importance of health center. But health center workers strongly acknowledged the importance of both health service and heath center. 2) As to the level of human resoureces, equipments and ammenities of Health Center commpared with private medical institute, the persons involved in district health's administration and health center workers responded that health center was higher in following order : 54.9%, 41.6%, 36.5% and 88.0%, 80.7%, 44.1%. 3) Concerning the priorities of health center's improvement, the persons involved in district health's administration replied in the order of reinforcement of proffesional health workers (43.3%), improvement of equipments and ammenities(28.3%), and the health center workers replied in the order of reconstruction of organization(24.1%), public health education and promotion(22.8%), reinforcement of proffesional health workers(21.0%). 4) Both the persons involved in district health's administration and health center workers replied that Ministry Health and Welfare, District office, health center were essential as the most critical organizations in the activation of Health Center's Function. 5) Persons involved in district health's administration and health center workers chose, as the most important health center's Function, medical treatment and prevention of infectious disease, and prevention of acute and chrone disease control and special district health service, respectively. Both Groups replied that fammily planning and parasite control are no longer in need. 6) As the future health service requiring reinforcement, every human resources parties considered health conselling, health line, sex education as the most imortant elements in public health education. Concerning the reinforement of other health services such as medical checkup and visiting nurses, every human resources parties showed more than 80% approval rate, but for oriental medical care service, the private medical personels showed relatively low approval rate(52.9%). Therefore the planning for reinforcement of health center's function requires the reflection of human resources party's opinion and the implication of system which can control and combine the differences in party's opinions.

  • PDF

Preliminary Results of Stereotactic Radiosurgery Using Stereotactic Body Frame (정위 체부 고정틀을 이용한 체부 방사선수술의 예비적 결과)

  • Ahn Seung Do;Yi Byong Yong;Choi Eun Kyung;Kim Jong Hoo;Nho Young Ju;Shin Kyung Hwan;Kim Kyoung Ju;Chung Won Kyun;Chang Hyesook
    • Radiation Oncology Journal
    • /
    • v.18 no.4
    • /
    • pp.251-256
    • /
    • 2000
  • Purpose : To evaluate efficacy and complication of stereotactic radiosurgery using stereotactic body frame. Methods and Materials :From December 1997 to June 1999, 11 patients with primary and metastatic tumors were treated with stereotactic radiosurgery using stereotactic body frame(Precision TherapyTu). Three patients were treated with primary hepatoma and seven with metastatic tumor from liver, lung, breast, trachea and one with arteriovenous malformation on neck. We used vacuum pillow for immobilization and made skin marker on sternum and tibia area with chest marker and leg marker. Diaphragm control was used for reducing movement by respiration. CT-simulation and treatment planning were peformed. Set-up error was checked by CT-Simulator before each treatment. Dose were calculated on the 80$\~$90$\%$ isodose of isocenter dose and given consecutive 3 fractions for total dose of 30 Gy (10 Gy/fraction). Results :Median follow-up was 12 months. One patient (9$\%$) showed complete response and four Patients (36$\%$) showed partial response and others showed stable disease. Planning target volumes (PTV) ranged from 3 to 111 cc (mean 18.4 n). Set-up error was within 5 mm in all directions (X, Y, Z axis). There was no complication in all patients. Conclusion :In Primary and metastatic tumors, stereotactic body frame is very safe, accurate and effective treatment modality.

  • PDF

Effects for the Thermal Comfort Index Improvement of Park Woodlands and Lawns in Summer (여름철 공원 수림지와 잔디밭의 온열쾌적지수 개선 효과)

  • Ryu, Nam-Hyong;Lee, Chun-Seok
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.42 no.6
    • /
    • pp.21-30
    • /
    • 2014
  • The purpose of this study was to evaluate human thermal comfort in summer by the type of greenery in parks and to explore planning solutions to supply a comfortable thermal environment in parks. The research was conducted in three different land cover types: a park with multi-wide-canopied trees(WOODLAND), park with grass(LAWN) and park with pavement(PAV) as reference sites in Hamyang-Gun SangrimPark. Field measurements of air temperature, relative humidity and wind velocity, short-wave and long-wave radiation from six directions(east, west, north, south, upward and downward) were carried out in the summer of 2014(August 21-23 and 29-30). Mean Radiant Temperature($T_{mrt}$) absorbed by a human-biometeorological reference person was estimated from integral radiation and the calculation of angular factors. The thermal comfort index PET was calculated by Rayman software, UTCI, OUT_SET$^*$ were calculated using the UTCI Calculator and the Thermal Comfort Calculator of Richard DeDear. The results showed that the WOODLAND has the maximum cooling effect during daytime, reduced air temperatures/$T_{mrt}$ by up to $5.9^{\circ}C/35^{\circ}C$ compared to PAV and lowered heat stress values despite increasing relative humidity values and decreasing wind velocity. While the LAWN had very slight cooling effects during daytime, reduced air temperatures/$T_{mrt}$ by up to $0.9^{\circ}C/3^{\circ}C$ compared to PAV, the improvement effects of the thermal comfort index was very slight. However, during nighttime the microclimatic and radiant conditions of WOODLAND, LAWN, and PAV were similar owing to the absence of solar radiation, reduction of wind velocity and an increase in relative humidity. Because the shading and evapotranspiration effects of the WOODLAND were much greater than the evapotranspiration effects of the LAWN, it can be said that the solutions for supplying comfortable thermal environment in parks are to amplify the green volumes rather than green areas. This study was undertaken to evaluate the human thermal comfort in summer of WOODLAND/LAWN parks and to determine the improvement effects of thermal comfort index. These results can contribute to the provision better thermal comfort for park users during park planning.

Evaluation of the effect of a Position Error of a Customized Si-Bolus Produced using a 3D-Printer: Cervical Cancer Radiation Treatment (3D 프린터를 이용하여 제작한 맞춤형 Si-Bolus의 위치 오차 효과 평가: 자궁경부암 방사선 치료)

  • Seong Pyo Hong;Ji Oh Jeong;Seung Jae Lee;Byung Jin Choi;Chung Mo Kim;Soo Il Jung;Yun Sung Shin
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.35
    • /
    • pp.7-13
    • /
    • 2023
  • Purpose: In this study, we evaluated the effect of using a customized bolus on dose delivery in the treatment plan when cervical cancer protruded out of the body along with the uterus and evaluated reproducibility in patient set-up. Materials & Methods: The treatment plan used the Eclipse Treatment Planning System (Version 15.5.0, Varian, USA) and the treatment machine was VitalBeam (Varian Medical Systems, USA). The radiotherapy technique used 6 MV energy in the AP/PA direction with 3D-CRT. The prescribed dose is 1.8 Gy/fx and the total dose is 50.4 Gy/28 fx. Semiflex TM31010 (PTW, Germany) was used as the ion chamber, and the dose distribution was analyzed and evaluated by comparing the planned and measured dose according to each position movement and the tumor center dose. The first measurement was performed at the center by applying a customized bolus to the phantom, and the measurement was performed while moving in the range of -2 cm to +2 cm in the X, Y, and Z directions from the center assuming a positional error. It was measured at intervals of 0.5 cm, the Y-axis direction was measured up to ±3 cm, and the situation in which Bolus was set-up incorrectly was also measured. The measured doses were compared based on doses corrected to CT Hounsfield Unit (HU) 240 of silicon instead of the phantom's air cavity. Result: The treatment dose distribution was uniform when the customized bolus was used, and there was no significant difference between the prescribed dose and the actual measured value even when positional errors occurred. It was confirmed that the existing sheet-type bolus is difficult to compensate for irregularly shaped tumors protruding outside the body, but customized Bolus is found to be useful in delivering treatment doses uniformly.

  • PDF

Analysis of the Causes of Subfrontal Recurrence in Medulloblastoma and Its Salvage Treatment (수모세포종의 방사선치료 후 전두엽하방 재발된 환자에서 원인 분석 및 구제 치료)

  • Cho Jae Ho;Koom Woong Sub;Lee Chang Geol;Kim Kyoung Ju;Shim Su Jung;Bak Jino;Jeong Kyoungkeun;Kim Tae_Gon;Kim Dong Seok;Choi oong-Uhn;Suh Chang Ok
    • Radiation Oncology Journal
    • /
    • v.22 no.3
    • /
    • pp.165-176
    • /
    • 2004
  • Purpose: Firstly, to analyze facto in terms of radiation treatment that might potentially cause subfrontal relapse in two patients who had been treated by craniospinal irradiation (CSI) for medulloblastoma, Secondly, to explore an effective salvage treatment for these relapses. Materials and Methods: Two patients who had high-risk disease (T3bMl, T3bM3) were treated with combined chemoradiotherapy CT-simulation based radiation-treatment planning (RTP) was peformed. One patient who experienced relapse at 16 months after CSI was treated with salvage surgery followed by a 30.6 Gy IMRT (intensity modulated radiotherapy). The other patient whose tumor relapsed at 12 months after CSI was treated by surgery alone for the recurrence. To investigate factors that might potentially cause subfrontal relapse, we evaluated thoroughly the charts and treatment planning process including portal films, and tried to find out a method to give help for placing blocks appropriately between subfrotal-cribrifrom plate region and both eyes. To salvage subfrontal relapse in a patient, re-irradiation was planned after subtotal tumor removal. We have decided to treat this patient with IMRT because of the proximity of critical normal tissues and large burden of re-irradiation. With seven beam directions, the prescribed mean dose to PTV was 30.6 Gy (1.8 Gy fraction) and the doses to the optic nerves and eyes were limited to 25 Gy and 10 Gy, respectively. Results: Review of radiotherapy Portals clearly indicated that the subfrontal-cribriform plate region was excluded from the therapy beam by eye blocks in both cases, resulting in cold spot within the target volume, When the whole brain was rendered in 3-D after organ drawing in each slice, it was easier to judge appropriateness of the blocks in port film. IMRT planning showed excellent dose distributions (Mean doses to PTV, right and left optic nerves, right and left eyes: 31.1 Gy, 14.7 Gy, 13.9 Gy, 6.9 Gy, and 5.5 Gy, respectively. Maximum dose to PTV: 36 Gy). The patient who received IMRT is still alive with no evidence of recurrence and any neurologic complications for 1 year. Conclusion: To prevent recurrence of medulloblastoma in subfrontal-cribriform plate region, we need to pay close attention to the placement of eye blocks during the treatment. Once subfrontal recurrence has happened, IMRT may be a good choice for re-irradiation as a salvage treatment to maximize the differences of dose distributions between the normal tissues and target volume.

Evaluating the usefulness of BinkieRTTM (oral positioning stent) for Head and Neck Radiotherapy (두경부암 환자 방사선 치료 시 BinkieRTTM(구강용 고정장치)에 대한 유용성 평가)

  • GyeongJin Lee;SangJun Son;GyeongDal Lim;ChanYong Kim;JeHee Lee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.34
    • /
    • pp.21-30
    • /
    • 2022
  • Purpose: The purpose of this study is to evaluate the effectiveness of oral positioning stent, the BinkieRTTM in radiation treatment for head and neck cancer patients in terms of tongue positions reproducibility, tongue doses and material properties. Materials and Methods: 24 cases using BinkieRTTM during radiation treatments were enrolled. The tongue was contoured on planning CT and CBCT images taken every 3 days during treatment, and then the DSC and center of tongue shift values were analyzed to evaluate the reproducibility of the tongue. The tongue dose was compared in terms of dose distribution when using BinkieRTTM and different type of oral stents (mouthpiece, paraffin wax). Randomly selected respective 10 patients were measured tongue doses of initial treatment plan for nasal cavity and unilateral parotid cancer. Finally, In terms of material evaluation, HU and relative electron density were identified in RTPS. Results: As a result of DSC analysis, it was 0.8 ± 0.07, skewness -0.8, kurtosis 0.61, and 95% CI was 0.79~0.82. To analyze the deviation of the central tongue shift during the treatment period, a 95% confidence interval for shift in the LR, SI, and AP directions were indicated, and a one-sample t-test for 0, which is an ideal value in the deviation(n=144). As a result of the t-test, the mean and SD in the LR and SI directions were 0.01 ± 0.14 cm (p→.05), 0.03 ± 0.25 cm (p→.05), and -0.08 ± 0.25 cm (p ←.05) in the AP direction. In the case of unilateral parotid cancer patients, the Dmean to the tongue of patients using BinkieRTTM was 16.92% ± 3.58% compared to the prescribed dose, and 23.99% ± 10.86% of patients with Paraffin Wax, indicating that the tongue dose was relatively lower when using BinkieRTTM (p←.05). On the other hand, among nasal cavity cancer patients, the Dmean of tongue dose for patients who used BinkieRTTM was 4.4% ± 5.6%, and for those who used mouthpiece, 5.9% ± 6.8%, but it was not statistically significant (p→.05). The relative electron density of Paraffin Wax, BinkieRTTM and Putty is 0.94, 0.99, 1.26 and the mass density is 0.95, 0.99 and 1.32 (g/cc), Transmission Factor is 0.99, 0.98, 0.96 respectively. Conclusion: The result of the tongue DSC analysis over the treatment period was about 0.8 and Deviation of the center of tongue shifts were within 0.2 cm, the reproducibility was more likely excellent. In the case of unilateral head and neck cancer patients, it was found that the use of BinkieRTTM rather than Paraffin Wax or Putty can reduce the unnecessary dose irradiated to the tongue. This study might be useful to understand of BinkieRTTM's properties and advantages. And also it could be another considered option as oral stent to keep the reproducibility of tongue and reducing dose during head and neck radiation treatments.

Clinical Usefulness of Implanted Fiducial Markers for Hypofractionated Radiotherapy of Prostate Cancer (전립선암의 소분할 방사선치료 시에 위치표지자 삽입의 유용성)

  • Choi, Young-Min;Ahn, Sung-Hwan;Lee, Hyung-Sik;Hur, Won-Joo;Yoon, Jin-Han;Kim, Tae-Hyo;Kim, Soo-Dong;Yun, Seong-Guk
    • Radiation Oncology Journal
    • /
    • v.29 no.2
    • /
    • pp.91-98
    • /
    • 2011
  • Purpose: To assess the usefulness of implanted fiducial markers in the setup of hypofractionated radiotherapy for prostate cancer patients by comparing a fiducial marker matched setup with a pelvic bone match. Materials and Methods: Four prostate cancer patients treated with definitive hypofractionated radiotherapy between September 2009 and August 2010 were enrolled in this study. Three gold fiducial markers were implanted into the prostate and through the rectum under ultrasound guidance around a week before radiotherapy. Glycerin enemas were given prior to each radiotherapy planning CT and every radiotherapy session. Hypofractionated radiotherapy was planned for a total dose of 59.5 Gy in daily 3.5 Gy with using the Novalis system. Orthogonal kV X-rays were taken before radiotherapy. Treatment positions were adjusted according to the results from the fusion of the fiducial markers on digitally reconstructed radiographs of a radiotherapy plan with those on orthogonal kV X-rays. When the difference in the coordinates from the fiducial marker fusion was less than 1 mm, the patient position was approved for radiotherapy. A virtual bone matching was carried out at the fiducial marker matched position, and then a setup difference between the fiducial marker matching and bone matching was evaluated. Results: Three patients received a planned 17-fractionated radiotherapy and the rest underwent 16 fractionations. The setup error of the fiducial marker matching was $0.94{\pm}0.62$ mm (range, 0.09 to 3.01 mm; median, 0.81 mm), and the means of the lateral, craniocaudal, and anteroposterior errors were $0.39{\pm}0.34$ mm, $0.46{\pm}0.34$ mm, and $0.57{\pm}0.59$ mm, respectively. The setup error of the pelvic bony matching was $3.15{\pm}2.03$ mm (range, 0.25 to 8.23 mm; median, 2.95 mm), and the error of craniocaudal direction ($2.29{\pm}1.95$ mm) was significantly larger than those of anteroposterior ($1.73{\pm}1.31$ mm) and lateral directions ($0.45{\pm}0.37$ mm), respectively (p<0.05). Incidences of over 3 mm and 5 mm in setup difference among the fractionations were 1.5% and 0% in the fiducial marker matching, respectively, and 49.3% and 17.9% in the pelvic bone matching, respectively. Conclusion: The more precise setup of hypofractionated radiotherapy for prostate cancer patients is feasible with the implanted fiducial marker matching compared with the pelvic bony matching. Therefore, a less marginal expansion of planning target volume produces less radiation exposure to adjacent normal tissues, which could ultimately make hypofractionated radiotherapy safer.

Verification of skin dose according to the location of tumor in Tomotherapy (토모테라피 시 종양의 위치에 따른 피부선량 검증)

  • Yoon, Bo Reum;Park, Su Yeon;Park, Byoung Suk;Kim, Jong Sik;Song, Ki Won
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.273-280
    • /
    • 2014
  • Purpose : To verify the skin dose in Tomotherapy-based radiation treatment according to the change in tumor locations, skin dose was measured by using Gafchromic EBT3 film and compared with the planned doses to find out the gap between them. Materials and Methods : In this study, to measure the skin dose, I'm RT Phantom(IBA Dosimetry, Germany) was utilized. After obtaining the 2.5mm CT images, tumor locations and skin dose measuring points were set by using Pinnacle(ver 9.2, Philips Medical System, USA). The tumor location was decided to be 5mm and 10mm away from surface of the phantom and center. Considering the attenuation of a Tomo-couch, we ensured a symmetric placement between the ceiling and floor directions of the phantom. The measuring point of skin doses was set to have 3mm and 5mm thickness from the surface. Measurement was done 3 times. By employing TomoHD(TomoHD treatment system, Tomotherapy Inc., Madison, Wisconsin, USA), we devised Tomotherapy plans, measured 3 times by inserting Gafchromic EBT3 film into the phantom and compared the measurement with the skin dose treatment plans. Results : The skin doses in the upper part of the phantom, when the tumor was located in the center, were found to be 7.53 cGy and 7.25 cGy in 5mm and 3mm respectively. If placed 5mm away from the skin in the ceiling direction, doses were 18.06 cGy and 16.89 cGy; if 10mm away, 20.37 cGy and 18.27 cGy, respectively. The skin doses in the lower part of the phantom, when the tumor was located in the center, recorded 8.82 cGy and 8.29 cGy in 5mm and 3mm, each; if located 5mm away from the lower part skin, 21.69 cGy and 19.78 cGy were respectively recorded; and if 10mm away, 20.48 cGy and 19.57 cGy were recorded. If the tumor was placed in the center, skin doses were found to increase by 3.2~17.1% whereas if the tumor is 5mm away from the ceiling part, the figure decreased to 2.8~9.0%. To the Tomo-couch direction, skin doses showed an average increase of 11% or over, compared to the planned treatment. Conclusion : This study found gaps between planned skin doses and actual doses in the Tomotherapy treatment planning. Especially to the Tomo-cocuh direction, skin doses were found to be larger than the planned doses. Thus, during the treatment of tumors near the Tomo-couch, doses will need to be more accurately calculated and more efforts to verify skin doses will be required as well.