• 제목/요약/키워드: Planetary boundary layers height

Search Result 5, Processing Time 0.02 seconds

One-Dimensional Model for Simulations of Atmospheric Mixed Layer : Application to Dukyang Bay Area (대기혼합층 모사를 위한 1차원 수치모형 : 득량만에서의 적용)

  • Kim, Yoo-Keun;Moon, Sung-Euii;Ahn, Joong-Bae
    • Journal of Environmental Science International
    • /
    • v.6 no.5
    • /
    • pp.425-435
    • /
    • 1997
  • One-dimensional thermodynamic mixed layer model to stimulate variations of meteorological variables wish the planetary boundary layer has been developed In this study. This model consists of 2 prognostic equations, which can predict the variations of potential temperature and mixing ratio and several diagnostic equations. Physics within the surface and mixed layers has been considered seperately in the model. For the variations of the model, Its result has been analysed and compared with observated data over Ole Dukyang Bay for one day, July 23, 1992. The simulated height of mixed layer is comparable to the observation and the variations of temperature and mixing ratio in the mixed layer are also reasonably simulated. Those Imply that the model responds appropriately with given boundary conditions In sprite of Its simplilfied assumptions applied to the model and insufficient boundary and Initial conditions.

  • PDF

Sensitivity Experiments of Vertical Resolution and Planetary Boundary Layer Parameterization Schemes on the Seoul Metropolitan Area using WRF Model (수도권 지역의 고해상도 WRF 모델 기반 연직 해상도 및 경계층 모수화 방안 민감도 실험)

  • Lim, A-Young;Roh, Joon-Woo;Jee, Joon-Bum;Choi, Young-Jean
    • Journal of the Korean earth science society
    • /
    • v.36 no.6
    • /
    • pp.553-566
    • /
    • 2015
  • The effects of vertical resolutions and planetary boundary layer (PBL) physics schemes in a numerical simulation with a very high resolution over the metropolitan area were investigated. The numerical experiments using the Weather Research and Forecast model were conducted from 0000 UTC 25 October to 0000 UTC 26 October 2013. We verified the numerical results against with six hourly observation data from the radiosonde at Seolleung, which was located in southern part of Seoul, and forty three auto weather systems in Seoul. In the experiments of vertical resolutions in low level atmosphere with 44, 50, and 60 layers, which are set to be subdivided particularly under 2 km height. The experiment in 60 layers, which has the highest vertical resolution in this study, showed relatively a clear diurnal variation of PBL heights. Especially, the difference of PBL heights and 10-meter wind fields were mainly seen in the area of high altitude lands for the experiments of vertical resolution. In the sensitivity experiment of PBL schemes such as asymmetric convective model-version 2 (ACM2), Yonsei University (YSU), and Mellow-Yamada-Janjic (MYJ) to the temperature, all three PBL schemes revealed lower temperature than observed profile from the radiosonde in the entire period. The experiments with YSU PBL and ACM2 PBL schemes show relatively less biased in comparison with the experiment of the MYJ PBL scheme.

Verification of the Planetary Boundary Layer Height Calculated from the Numerical Model Using a Vehicle-Mounted Lidar System (차량탑재 라이다 시스템을 활용한 수치모델 행성경계층고도 검증)

  • Park, Chang-Geun;Nam, Hyoung-Gu
    • Korean Journal of Remote Sensing
    • /
    • v.36 no.5_1
    • /
    • pp.793-806
    • /
    • 2020
  • In this study,for YSU (Yonsei University), MYJ(Mellor-Yamada-Janjic), ACM2 (Asymmetric Convective Model), and BouLac (Bougeault-Lacarrere) PBL schemes, numerical experiments were performed for the case period (June 26-30, 2014). The PBLH calculated by using the backscatter signal produced by the mobile vehicle-mounted lidar system (LIVE) and the PBLH calculated by the prediction of each PBL schemes of WRF were compared and analyzed. In general, the experiments using the non-local schemes showed a higher correlation than the local schemes for lidar observation. The standard deviation of the PBLH difference for daylight hours was small in the order of YSU (≈0.39 km), BouLac (≈0.45 km), ACM2 (≈0.47 km), MYJ (≈0.53 km) PBL schemes. In the RMSE comparison for the case period, the YSU PBL scheme was found to have the highest precision. The meteorological lider mounted on the vehicle is expected to provide guidance for the analysis of the planetary boundary layer in a numerical model under various weather conditions.

Modelling of Aerosol Vertical Distribution during a Spring Season at Gwangju, Korea

  • Shin, Sung-Kyun;Lee, Kwon-Ho
    • Asian Journal of Atmospheric Environment
    • /
    • v.10 no.1
    • /
    • pp.13-21
    • /
    • 2016
  • The vertical distributions of aerosol extinction coefficient were estimated using the scaling height retrieved at Gwangju, Korea ($35.23^{\circ}N$, $126.84^{\circ}E$) during a spring season (March to May) of 2009. The aerosol scaling heights were calculated on a basis of the aerosol optical depth (AOD) and the surface visibilities. During the observation period, the scaling heights varied between 3.55 km and 0.39 km. The retrieved vertical profiles of extinction coefficient from these scaling heights were compared with extinction profile derived from the Light Detection and Ranging (LIDAR) observation. The retrieve vertical profiles of aerosol extinction coefficient were categorized into three classes according to the values of AODs and the surface visibilities: (Case I) the AODs and the surface visibilities are measured as both high, (Case II) the AODs and the surface visibilities are both lower, and (Others) the others. The averaged scaling heights for the three cases were $3.09{\pm}0.46km$, $0.82{\pm}0.27km$, and $1.46{\pm}0.57km$, respectively. For Case I, differences between the vertical profile retrieved from the scaling height and the LIDAR observation was highest. Because aerosols in Case I are considered as dust-dominant, uplifted dust above planetary boundary layer (PBL) was influenced this discrepancy. However, for the Case II and other cases, the modelled vertical aerosol extinction profiles from the scaling heights are in good agreement with the results from the LIDAR observation. Although limitation in the current modelling of vertical structure of aerosols exists for aerosol layers above PBL, the results are promising to assess aerosol profile without high-cost instruments.

Vertical Ozone Distribution over Seoul: Ozonesonde Measurements During June 6~9, 2003 (서울지역 연직 오존 분포: 2003년 6월 6~9일 오존존데 관측)

  • Hwang, Mi-Kyoung;Kim, Yoo-Keun;Oh, In-Bo;Song, Sang-Keun;Lim, Yun-Kyu
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.24 no.2
    • /
    • pp.196-205
    • /
    • 2008
  • Variability in vertical ozone and meteorological profiles was measured by 2Z electrochemical concentration cells (ECC) ozonesonde at Bangyi in Seoul ($37.52^{\circ}N$, $127.13^{\circ}E$) during June $6{\sim}9$, 2003 in odor to identify the vertical distribution of ozone and its relationship with the lower-atmospheric structure resulted in the high ozone concentrations near the surface. The eight profiles obtained in the early morning and the late afternoon during the study period clearly showed that the substantial change of ozone concentrations in lower atmosphere(${\sim}5\;km$), indicating that it is tightly coupled to the variation of the planetary boundary layer (PBL) structure as well as the background synoptic flow. All profiles observed early in the morning showed very low ozone concentrations near the surface with strong vertical gradients in the nocturnal stable boundary layer due to the photochemical ozone loss caused by surface NO titration under very weak vertical mixing. On the other hand, relatively uniform ozone profiles in the developed mixing layer and the ozone peaks in the upper PBL, were observed in the late afternoon. It was noted that a significant increase in ozone concentrations in the lower atmosphere occurred with the corresponding decrease of the mixing height in the late afternoon on June 8. Ozone in upper layer did not vertically vary much compared to that in PBL but changed significantly on June 6 that was closely associated with the variation of synoptic flows. Interestingly, heavily polluted ozone layers aloft (a maximum value of 115 ppb around 2 km) were formed early in the morning on 6 through 7 June under dominant westerly synoptic flows. This indicates the effects of the transport of pollutants on regional scale and consequently can give a rise to increase the surface ozone concentration by downward mixing processes enhanced in the afternoon.