• Title/Summary/Keyword: Planar.

Search Result 3,651, Processing Time 0.029 seconds

A Study on a Planar Array Antenna Design with a Flat-Topped Radiation Pattern (구형 방사 패턴을 갖는 평면 배열 안테나 설계에 대한 연구)

  • Eom Soon-Young;Pyo Cheol-Sig;Jeon Soon-Ick;Kim Chang-Joo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.15 no.9
    • /
    • pp.896-905
    • /
    • 2004
  • In this paper, the design, fabrication and experiment on a planar array antenna with a flat-topped radiation pattern for a mobile base station antenna were described. The current distribution of an antenna aperture, which is easily realizable in a feeding network compared with the conventional one of sin(x)/x was optimized for shaping a desired flat-topped radiation pattern. The planar array antenna designed in this paper has a rectangular lattice and is composed of array elements of 16${\times}$8. Each radiating element, which is a microstrip element fed coaxially, has a linear vertical polarization and the feed network which use a Wilkinson power divider and a 180$^{\circ}$ ring hybrid coupler as a base element is designed. The flat-topped radiation pattern with 90$^{\circ}$ is shaped by 16 array elements with the element spacing of 0.55 λ$_{ο}$ in the azimuth plane, and the normal radiation pattern with 10$^{\circ}$ is shaped by 8 array elements with the element spacing of 0.65 λ$_{ο}$ in the elevation plane. Also, the planar array antenna is symmetrically divided into four parts. It consists of one hundred-twenty-eight radiating elements, thirty-two 1-4 column dividers, low 1-8 row dividers and one 1-4 input power divider. In order to verify electrical performances of the planar way antenna proposed in this paper, the experimental breadboard operated in tile band of 1.92~2.17 GHz(IMT2000 band) was fabricated, and its experimental results were a good agreement with simulation ones.

Clinical Usefulness of 99mTc-DMSA Renal SPECT Using High Sensitivity-All Purpose Collimator for Pediatric Patients (고감도 범용성 콜리메이터를 이용한 소아 환자 99mTc-DMSA 신장 SPECT의 유용성)

  • Kim, Jin-Eui;Kim, Jung-Soo;Han, Jae-Bok;Choi, Nam-Gil
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.3
    • /
    • pp.219-231
    • /
    • 2016
  • $^{99m}Tc$-DMSA planar scan that can analyze the functions of kidney quantitatively provides less information on a lesion than tomography scanning. Therefore, this study applied a high sensitivity all-purpose collimator that is sensitive to photonic signals to $^{99m}Tc$-DMSA and carried out a clinical scan with single photon emission computed tomography (SPECT). And diagnostic accuracy and time requirement of were analyzed to know the clinical usefulness of the applied scanning method. 10 subjects were intravenously injected with radiopharmaceutical product (1.0-1.2 MBq/kg) and scanned by a gamma camera with planar scanner (high resolution (HR)-mode, $256{\times}256$, 50 kcts/view, 4 image) and SPECT (HR / high sensitive (HS)-mode, $128{\times}128$, step and shoot, $180^{\circ}$, variable sec/angle, total 64 frame, OSEM reconstruction), respectively. The collected data was compared with an analysis program. The results showed that HS-mode SPECT detected total counts 1.8-5.6 times more than planar scan. Relative renal function evaluated based on the counts was not significantly different by two scanning methods (p=0.96) and it turned out that test time was shortened by 39% when HS-mode SPECT was used. Therefore, SPECT using HR, HS-mode collimator could analyze renal function more quantitatively than using planar scan and the former could diagnose the location information of a lesion more accurately than the latter as well as shortened test time requirement, which demonstrated the clinical usefulness of $^{99m}Tc$-DMSA renal SPECT using high sensitivity all purpose collimator.

The Clinical Role of $^{99m}Tc$-(V)-DMSA Imaging in Patients with Head and Neck Cancer (두경부 종양에서 $^{99m}Tc$-(V)-DMSA 영상술의 진단적 유용성)

  • Bae, Sun-Kun;Lee, Jae-Tae;Park, June-Sik;Park, In-Kyu;Hyun, Dong-Woo;Lee, Young-Hak;Kim, Jeong-Gyun;Ahn, Byeong-Cheal;Choi, Ji-Yong;Sohn, Sang-Gyun;Lee, Kyu-Bo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.4
    • /
    • pp.526-532
    • /
    • 1995
  • Introduction : $^{99m}Tc$-(V)-DMSA is a tumor seeking agent that has been used to image medullary carcinoma of thyroid, soft tissue sarcoma and lung cancer. This study was designed to assess the clinical role of $^{99m}Tc$-(V)-DMSA in the diagnosis of head and neck cancers. We has evaluated the diagnostic efficacy of planar and SPECT imaging using $^{99m}Tc$-(V)-DMSA. Patients and Method : Sixty-eight patients with head and neck mass were included in this study. All subjects were diagnosed by biopsy or surgery. Planar and SPECT images were obtained at 2 or 3 hour after intravenous injection of 740 MBq(20 mCi) $^{99m}Tc$-(V)-DMSA. Seventeen patients also underwent SPECT in aging using dual head camera. Result : The diagnostic sensitivity of $^{99m}Tc$-(V)-DMSA planar and SPECT imaging was 65% and 90%, and specificity was 80% and 66%, respectively. The sensitivity of planar imaging in squamous cell carcinoma was similar to overall sensitivity Six metastatic lesion were first diagnosed by scintigraphy. But benign lesions such as Kikuchi syndrome, tuberculous lymphadenitis also revealed increased uptake. Conclusion : $^{99m}Tc$-(V)-DMSA imaging seems to be a promising method in the evaluation of patients with head and neck mass. We recommend SPECT imaging to delineate anatomic localization of the lesion.

  • PDF

A Planar Implementation of a Negative Group Delay Circuit (평면 구조의 마이너스 군지연 회로 설계)

  • Jeong, Yong-Chae;Choi, Heung-Jae;Chaudhary, Girdhari;Kim, Chul-Dong;Lim, Jong-Sik
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.3
    • /
    • pp.236-244
    • /
    • 2010
  • In this paper, a planar structure negative group delay circuit(NGDC) is proposed to overcome the limited availability of the component values required for the prototype lumped element(LE) NGDC design. From the prototype LE circuit analysis, general design equations and the conditions to obtain the NGD are derived and illustrated. Then the LE circuit is converted into the planar structure by applying the transmission line resonator(TLR) theory. As a design example, the LE NGDC and the proposed planar structure NGDC are designed and compared. To estimate the commercial applicability, 2-stage reflection type planar NGDC with -5.6 ns of total group delay, -0.2 dB of insertion loss, and 30 MHz of bandwidth together with 0.1 dB and 0.5 ns of the magnitude and group delay flatness, respectively, for Wideband Code Division Multiple Access(WCDMA) downlink band is fabricated and demonstrated. Also, to show the applicability of the proposed NGDC, we have configured a simple signal cancellation loop and obtained good loop suppression performance.

Heating Characteristics of Planar Heater Fabricated with Different Mixing Ratios of MXene-CNT-WPU Composites (MXene-CNT-WPU 복합소재 기반 면상발열체의 배합 비율에 따른 발열 특성)

  • Hyo-Jun, Oh;Quy-Dat, Nguyen;Yoonsik, Yi;Choon-Gi, Choi
    • Clean Technology
    • /
    • v.28 no.4
    • /
    • pp.278-284
    • /
    • 2022
  • This study presents an excellent planar heater based on low-dimensional composites. By optimizing the ratio of 1D carbon nanotubes (CNT) and 2D MXene (Ti3C2TX), it is possible to create a planar heater that has superior electrical conductivity and high heat generation characteristics. Low-dimensional composites were prepared by mixing CNT paste and MXene solution with eco-friendly waterborne polyurethane (WPU). In order to find the optimal mixing ratio for the MXene-CNT-WPU composites, samples with MXene to CNT weight ratios of 3:1, 1:1, 1:3, 1:7, and 1:14 were investigated. In addition to these different weight ratios, 5 wt% WPU was equally applied to each sample. It was confirmed that the higher the weight ratio of CNT, the lower the sheet resistance and the higher the heating temperature. In particular, when the MXene-CNT-WPU planar heater was fabricated by mixing MXene and CNT at a weight ratio of 1:7 and 1:14, the heating temperature was higher than the heating temperature of a CNT-WPU planar heater. These characteristics are due to the optimized mixture of the 1D materials (CNT) and the 2D materials (MXene) causing the formation of a flat surface and a dense network structure. The low-dimensional composites manufactured with the optimized mixing ratios found in this study are expected to be applied in flexible electronic devices.

Planar near-field antenna measurement method based on symplectic relation and reaction concept

  • Cho, Yong-Heui
    • International Journal of Contents
    • /
    • v.6 no.2
    • /
    • pp.6-9
    • /
    • 2010
  • Using symplectic relation and reaction concept, we propose a planar near-field antenna measurement method. A generalized probe compensation equation is deduced to obtain the probe correction formulation. To verify our approach, a reflector antenna with $1{\times}2$ horn array is fabricated and measured in the near-field measurement facility. The near-field measurement results are compared with the physical optics (PO) simulation. The results of measurement and simulation agree very well near to the mainbeam.

A Study on the Application of Direct Method for the Inelastic Analysis of Planar Frames (평면골조의 비탄성 거동해석을 위한 Direct Method의 적용에 관한 연구)

  • 윤태호;이상호;정일영
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1995.04a
    • /
    • pp.1-8
    • /
    • 1995
  • A method for the inelastic response analysis of Planar frame based on Direct Method is presented. Two elements ( inelastic truss and inelastic beam ) are developed. The accuracy and reliability of the preposed method is verified by comparing the results of example analysis with BRAIN-2D developed by Powell.

  • PDF

Probabilistic Estimation of Area- and Feature-based Stereo Matching Results Considering Uncertatinty (불확실성을 고려한 영역과 특징기반 스테레오 정합결과의 확률적 통합)

  • 문인혁
    • Proceedings of the IEEK Conference
    • /
    • 2001.06d
    • /
    • pp.69-72
    • /
    • 2001
  • This paper proposes a positional estimation method for extracted line features by stereo vision. Based on given reference plane, planar surfaces corresponding the given plane are first extracted. Then, features in the planar surfaces are selected. Using the Extended Kalman Filter the feature positions are estimated by combining area- and feature-based stereo matching results. Experimental results show the proposed method is feasible.

  • PDF

Robust plane sweep algorithm for planar curve segments

  • Lee, In-Kwon;Lee, Hwan-Yong;Kim, Myung-Soo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1991.10b
    • /
    • pp.1617-1622
    • /
    • 1991
  • Plane sweep is a general method in computational geometry. There are many efficient theoretical algorithms designed using plane sweep technique. However, their practical implementations are still suffering from the topological inconsistencies resulting from the numerical errors in geometric computations with finite-precision arithmetic. In this paper, we suggest new implementation techniques for the plane sweep algorithms to resolve the topological inconsistencies and construct the planar object boundaries from given input curve segments.

  • PDF

초고속 자기 공명 영상 기법 - Echo Planar 영상 및 Spiral Scan 영상

  • 안창범
    • Investigative Magnetic Resonance Imaging
    • /
    • v.3 no.1
    • /
    • pp.6-12
    • /
    • 1999
  • Echo Planar Imaging (EPI) Spiral Scan 영상을 초고속 자기공명영상 기법으로서 전체 k-space의 데이터를 한번 scan에 다 받을 수 있기 때문에 데이터 측정시간을 100ms 이내로 단축시킬 수 있다. 이러한 초고속 영상 기법은 최근 활발히 연구되고 있는 뇌기능 영상과 관련하여 중요도가 더욱 커지고 있다. EPI는 직각좌표계에서 데이터를 받기 때문에 재구성은 비교적 쉬우나 eddy current를 많이 야기시키는 단점을 가지고 있다. 반면에 Spiral Scan 영상은 먼저 데이터를 원 또는 직각좌표계로 interpolation을 한 후 재구성하여야 하는 단점이 있으나, 상대적으로 eddy current가 작고, 방향과 무관하게 균일한 point spread function을 가지며, 혈류와 관련한 위상이 스스로 rephasing 되어 심장 영상 등에 유리한 장점이 있다.

  • PDF