• 제목/요약/키워드: Planar position measurement

검색결과 18건 처리시간 0.019초

공간오차 측정을 통한 6자유도 병렬기구의 보정 (Calibration of 6-DOF Parallel Mechanism Through the Measurement of Volumetric Error)

  • 오용택;아궁 샴수딘 사라기;김정현;고태조
    • 한국기계가공학회지
    • /
    • 제11권3호
    • /
    • pp.48-54
    • /
    • 2012
  • This paper introduces the kinematic calibration method to improve the positioning accuracy of a parallel mechanism. Since all the actuators in the parallel mechanism are controlled simultaneously toward the target position, the volumetric errors originated from each motion element are too complicated. Therefore, the exact evaluation of the error sources of each motion element and its calibration is very important in terms of volumetric errors. In the calibration processes, the measurement of the errors between commands and trajectories is necessary in advance. To do this, a digitizer was used for the data acquisition in 3 dimensional space rather than arbitrary planar error data. After that, the optimization process that was used for reducing the motion errors were followed. Consequently, Levenberg-Marquart algorithm as well as the error data acquisition method turned out effective for the purpose of the calibration of the parallel mechanism.

Analysis of Absorption Loss by a Human Body in On-to-Off Body Communication at 2.45 GHz

  • Jeon, Jaesung;Lee, Sangwoo;Choi, Jaehoon;Kim, Sunwoo
    • Journal of electromagnetic engineering and science
    • /
    • 제15권2호
    • /
    • pp.97-103
    • /
    • 2015
  • This paper investigates the effect of absorption loss by a human body to the received signal strength with respect to on-body transmitting antenna positions in on-to-off wireless body area networks. This investigation is based on measurement results obtained from experiments performed on human bodies (male and female) using planar inverted-F antennas in an anechoic chamber. The total absorption loss by the human body is also presented through the SEMCAD-X simulations. Our investigation showed that the received signal strength becomes lower when the transmitting antenna is mounted at a specific position where more absorption loss is experienced. The statistical analyses of on-to-off body channel characteristics based on the measurement results are presented.

임의의 위치에서 사용 가능한 영상 기반 변위 계측 시스템 (Vision-Based Displacement Measurement System Operable at Arbitrary Positions)

  • 이준화;조수진;심성한
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제18권6호
    • /
    • pp.123-130
    • /
    • 2014
  • 본 연구에서는 카메라의 위치에 상관없이 정확하게 구조물의 변위를 측정할 수 있는 영상 기반 변위 계측 시스템을 제안하였다. 기존의 영상 기반 변위 계측 시스템은 카메라의 각도에 따라 오차를 유발하며, 그에 따라 대형 구조물에서 적용성에 제한되는 단점이 존재하였다. 본 시스템은 네 개의 점이 그려진 측정판을 변위를 측정하고자 하는 구조물의 위치에 부착하여 카메라로 촬영한 뒤 영상을 해석하여 변위를 얻는다. 측정판과 카메라의 각도에 무관하게 구조물의 변위를 얻기 위하여, 이미지 좌표계와 세계 좌표계 상의 두 평면간의 대응관계를 표현하는 평면 호모그래피 기법을 활용하였다. 성능 검증을 위하여 소형 구조물을 이용한 실내실험을 수행하였으며, 어떠한 각도에서 촬영하더라도 실제 변위를 정확하게 측정할 수 있음을 보였다.

자기동조 제어기를 이용한 위치확보 시스템에 관한 연구 (Analysis of Dynamic Positioning System Based on Self-Tuning Control)

  • 이상무;이판묵;홍사영
    • 대한조선학회지
    • /
    • 제26권2호
    • /
    • pp.32-40
    • /
    • 1989
  • 자동위치 확보시스템은 선박이 불규칙 해상에서 작업을 수행할 때 선체의 위치 및 선수를 일정한 작업반경 내에서 유지할 수 있도록 추진기를 자동제어하는 방법이다. 위치확보시스템의 구성은 계측시스템, 제어기시스템, 추진기시스템 및 동력시스템으로 구성된다. 본 논문은 최적제어 기법과 필터링 기법을 이용한 제어기시스템 구성에 관하여 논하였고, 제어시스템 구성을 위한 상태방정식의 정립과정을 서술하였다. 선체의 평면운동은 저주파수 운동과 고주파수 운동의 성분으로 구성되었다고 가정하였다. 저주파수 운동은 추진기에 의한 외력, 조류력 및 2차차수 파랑강제력에 기인하며 고주파수 운동은 1차 차수 파랑강제력에 의해 유기된다. 해상에서 계측되는 신호에는 선체의 운동성분 이외에도 계측오차 성분이 포함된다. 자기동조필터 및 칼만필터를 이용하여 계측신호로부터 저주파수 운동성분과 고주파수 운동성분을 각각 독립적으로 추정하고, 추정된 저주파수 운동성분을 궤환하여 제어를 수행하였다. 제어기는 교란환경 속의 최적제어기인 LQG제어기를 이용하였다. 시뮬레이션을 수행하기 위하여 Wimpey Sealab의 데이타를 이용하였다.

  • PDF

반자율무인잠수정의 수중 복합항법 시스템 성능평가를 위한 회전팔 시험 (Rotating Arm Test for Assessment of an Underwater Hybrid Navigation System for a Semi-Autonomous Underwater Vehicle)

  • 이종무;이판묵;김시문;홍석원;서재원;성우제
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.141-148
    • /
    • 2003
  • This paper presents a rotating ann test for assessment of an underwater hybrid navigation system for a semi-autonomous underwater vehicle. The navigation system consists of an inertial measurement unit (IMU), an ultra-short baseline (USBL) acoustic navigation sensor and a doppler velocity log (DVL) accompanying a magnetic compass. The errors of inertial measurement units increase with time due to the bias errors of gyros and accelerometers. A navigational system model is derived to include the error model of the USBL acoustic navigation sensor and the scale effect and bias errors of the DVL, of which the state equation composed of the navigation states and sensor parameters is 25 in the order. The conventional extended Kalman filter was used to propagate the error covariance, update the measurement errors and correct the state equation when the measurements are available. The rotating ann tests are conducted in the Ocean Engineering Basin of KRISO, KORDI to generate circular motion in laboratory, where the USBL system was absent in the basin. The hybrid underwater navigation system shows good tracking performance against the circular planar motion. Additionally this paper checked the effects of the sampling ratio of the navigation system and the possibility of the dead reckoning with the DVL and the magnetic compass to estimate the position of the vehicle.

  • PDF

전파속도를 알수 없는 재료에서의 AE 발생위치 온라인 측정 (AE source on-line localization on material with unknown acoustic wave propagation velocity)

  • 장경영;이원흠;김달중
    • 대한기계학회논문집A
    • /
    • 제22권3호
    • /
    • pp.688-694
    • /
    • 1998
  • The ability to locate the defects in materials is one of the major attrations of the acoustic emission(AE) technique. The most conventional method for planar AE source localization is to place three or more AE sensors on the plate and to determine the source position by measuring the differences in the arrival times of the AE wave at the sensors, which is called as triangulation method. But this method can not be applied in the material of which elastic wave propagtion velocity is not known. In this paper, we propose two methods, vector method and error minimization method, for AE source location on the material with unknown AE wave velocity. In this method, it is not needed to know the propagation velocity previously, that is, we can apply this method to arbitrary material of which properties are not known exactly. Also, in this paper, the robustness to the error in the measurement of time differences are discussed for both methods. Finally, in order to evaluate the actual performances, experiments using a pencil lead break as the AE source were carried out on the aluminum plate.

반자율무인잠수정의 수중 복합항법 시스템 성능평가를 위한 회전팔 시험 (Rotating Arm Test for Assessment of an Underwater Hybrid Navigation System for a Semi-Autonomous Underwater Vehicle)

  • 이종무;이판묵;김시문;홍석원;서재원;성우제
    • 한국해양공학회지
    • /
    • 제17권4호
    • /
    • pp.73-80
    • /
    • 2003
  • This paper presents considerations on the results of the rotating arm test, which was carried out for assessment of an hybrid navigation system for a semi-autonomous underwater vehicle. The navigation system consists of an inertial measurement unit(IMU), an ultra-short baseline(USBL) acoustic navigation sensor and a doppler velocity log(DVL) accompanying a magnetic compass. A navigational systemmodel is derived to include the scale effect and bias errors of the DVL, of which the state equation composed of the navigation states and sensor parameters are 25 in the order. The extended Kalman filter was used to propagate the error covariance, The rotating arm tests were carried out in the Ocean Engineering Basin of KRISO, to generate circular motion. The hybrid underwater navigation system shows good tracking performance against the circular planar motion. Additionally this paper checked the effects of the sampling ratio of the navigation system and the possibility of the dead reckoning with the DVL and the magnetic compass to estimate the position of the vehicle.

MR 관류강조영상에서 정상 가토의 국소 뇌혈류량 측정 (Measurement of Regional Cerebral Blood Volume in Normal Rabbits on Perfusion-weighted MR Image)

  • 박병래;예수영;나상옥;김학진;이석홍;전계록
    • Investigative Magnetic Resonance Imaging
    • /
    • 제4권2호
    • /
    • pp.100-106
    • /
    • 2000
  • 목적: 정상 가토의 뇌혈류를 측정하고자 자기공명영상 기법중 스캔시간이 훨씬 짧은 single shot gradient echo-planar 기법을 관류강조영상에 적용하여 뇌혈류량 측정법의 유용성을 알아보고자 하였다. 대상 및 방법: 몸무게 2.1-3.6kg의 가토 24마리를 실험군으로 채택하고, 실험군을 소아용 위치 잡이에 복와위로 눕힌 후 관류강조영상을 획득하였다. 관류강조영상 획득은 매 1초마다 연속하여 한 단면당 44초가지 44개의 영상을 얻었다. 스캔 시작 후 4초 경과시 조영제 Gd-DTPA 2ml를 빠른 속도로 경정맥 주입 후 연속하여 식염수 5ml를 경정맥 주입하였으며, 한 가토에서 동일한 방법으로 약 30분 간격으로 2회씩 실시하였다. 영상은 두정부 대뇌피질, 궁룡부 대뇌피 질 두 부위와 기저핵 한 부위에서 약 $3-5{\textrm{mm}^2}$의 면적으로 선택한 후, 시간 경과에 따른 신호강도의 변화를 보여주는 커브를 구하였다 이 영상을 PC로 전송한 후 자체 개발한 영상처리 프로그램과 IDL 소프트웨어를 이용하여 상대적 및 국소 뇌혈류량을 구하였다. 결과: 실험군으로 채택한 가토 총 24마리중 22마리에서 만족할 만한 1-2회의 시간-신호강도 곡선을 얻었다. 획득한 데이터는 두정부 대뇌피질 두 곳과 기저 핵에서 시간의 경과에 따른 신호강도의 변화를 측정하고, 이들 부위의 국소 뇌혈류 용적 및 조영제의 잔류 시간을 구하였다. 평균 국소 뇌혈류량 용적비는 궁륭부 대뇌피질에서는 $0.97{\pm}0.35$, 기저 핵에서는 $0.99{\pm}0.37$이었으며, 조영제의 펑균 잔류시간은 궁룡부 대뇌피질에서는 $9.83{\pm}1.63초$, 기저핵에서는 $9.42{\pm}1.14$초로서 두 부위간에 통계학적으로 유의한 차이는 없었다. 결론: 궁룡부 대뇌피질과 기저 핵에서 평균 국소 뇌혈류량 용적비와 조영제 평균잔류 시간의 차이는 없었다. 그러므로 PWI가 뇌혈류량 측정에 유용하며 허혈성 질환의 조기진단 및 예후 추정에 이용될 수 있다. 향후 정상조직과 뇌경색이 유발 된 조직의 rCBV차이를 비교할 수 있으며, DWI 소견과 경색 환자에 적용하면 뇌혈류 변화 분석에 도움이 될 것으로 사료된다.

  • PDF