• 제목/요약/키워드: Planar curve

검색결과 89건 처리시간 0.024초

Computational earthquake performance of plan-irregular shear wall structures subjected to different earthquake shock situations

  • Cao, Yan;Wakil, Karzan;Alyousef, Rayed;Yousif, Salim T.;Jermsittiparsert, Kittisak;Ho, Lanh Si;Alabduljabbar, Hisham;Alaskar, Abdulaziz;Alrshoudi, Fahed;Mohamed, Abdeliazim Mustafa
    • Earthquakes and Structures
    • /
    • 제18권5호
    • /
    • pp.567-580
    • /
    • 2020
  • In this paper, irregularly designed planar reinforced concrete wall structures are investigated computationally. For this purpose, structures consisting of four regular and irregular models of short-order (two-class) and intermediate (five-class) types have been investigated. The probabilistic evaluation of seismic damage of these structures has been performed by using the incremental inelastic dynamic analysis to produce the seismic fragility curve at different levels of damage. The fragility curves are based on two classes of maximum damage indices and the Jeong-Nansha three-dimensional damage index. It was found that there is a significant increase in damage probability in irregular structures compared to regular ones. The rate of increase was higher in moderate and extensive damage levels. Also, the amount of damage calculated using the two damage indices shows that the Jeong-Nensha three-dimensional damage index in these types of structures provides superior results.

대체천연가스 화염 이미지 역변환에서 전처리 효과 (Effect of a Preprocessing Method on Inverting Chemiluminescence Images of Flames Burning Substitute Natural Gas)

  • 안광호;송원준;차동진
    • 설비공학논문집
    • /
    • 제27권12호
    • /
    • pp.609-619
    • /
    • 2015
  • A preprocessing scheme utilizing multi-division of the ROI (region of interest) in a chemiluminescence image during inversion is proposed. The resulting inverted image shows the flame's structure, which can be useful for studying combustion instability. The flame structure is often quantitatively visualized with PLIF (planar laser-induced fluorescence) images as well. The chemiluminescence image, which is a line-integral of the flame, needs to be preprocessed before inversion, mainly due to the inherent noise and the assumption of axisymmetry during the inversion. The feasibility of the multi-division preprocessing technique has been tested with experimentally-obtained OH PLIF and $OH^*$ chemiluminescence images of jet and swirl-stabilized flames burning substitute natural gas (SNG). It turns out that the technique outperforms two conventional methods, specifically, the technique without preprocessing and the one with uni-division, reconstructing the SNG flame structures much better than its two counterparts when compared using corresponding OH PLIF images. The characteristics of the optimum degree of polynomials to be applied for curve-fitting of the flame region data for the multi-division method involving two flames has also been investigated.

컨포멀 위상 배열 안테나의 패턴 합성에 대한 고찰 (Study on Pattern Synthesis of Conformal Phased Array Antenna)

  • 박동철;권오혁;류홍균;이규송
    • 한국전자파학회논문지
    • /
    • 제26권12호
    • /
    • pp.1031-1043
    • /
    • 2015
  • 본 논문에서는 Enhanced Adaptive Genetic Algorithm(EAGA)를 이용하여 두 가지 종류의 컨포멀 배열 안테나의 패턴 합성 과정을 기술하였다. 한 종류는 2차 함수 형태의 실린더 도체 위에 배열된 $1{\times}16$ 배열 안테나이고, 다른 종류는 2차 함수 곡선의 회전체 곡면 도체 위에 배열된 18개 소자 배열 안테나이다. 패턴 합성시 각 소자의 능동 소자 패턴을 이용하였고, 특히 회전체형 배열 안테나의 경우, 합성 시간을 크게 줄이기 위해 동심원형 평면 배열 안테나의 능동 소자 패턴을 구한 뒤 이를 변환하여 사용하였다. 제안한 합성 기법의 타당성을 검증하기 위해 MATLAB 내에서 합성된 배열 안테나의 패턴과 MWS(Microwave Studio) 내에서 구현된 배열 안테나의 패턴을 비교하였으며, 또한, $1{\times}16$ 배열 안테나의 경우는 측정 패턴과 합성 패턴도 비교하였다.

MR 관류강조영상에서 정상 가토의 국소 뇌혈류량 측정 (Measurement of Regional Cerebral Blood Volume in Normal Rabbits on Perfusion-weighted MR Image)

  • 박병래;예수영;나상옥;김학진;이석홍;전계록
    • Investigative Magnetic Resonance Imaging
    • /
    • 제4권2호
    • /
    • pp.100-106
    • /
    • 2000
  • 목적: 정상 가토의 뇌혈류를 측정하고자 자기공명영상 기법중 스캔시간이 훨씬 짧은 single shot gradient echo-planar 기법을 관류강조영상에 적용하여 뇌혈류량 측정법의 유용성을 알아보고자 하였다. 대상 및 방법: 몸무게 2.1-3.6kg의 가토 24마리를 실험군으로 채택하고, 실험군을 소아용 위치 잡이에 복와위로 눕힌 후 관류강조영상을 획득하였다. 관류강조영상 획득은 매 1초마다 연속하여 한 단면당 44초가지 44개의 영상을 얻었다. 스캔 시작 후 4초 경과시 조영제 Gd-DTPA 2ml를 빠른 속도로 경정맥 주입 후 연속하여 식염수 5ml를 경정맥 주입하였으며, 한 가토에서 동일한 방법으로 약 30분 간격으로 2회씩 실시하였다. 영상은 두정부 대뇌피질, 궁룡부 대뇌피 질 두 부위와 기저핵 한 부위에서 약 $3-5{\textrm{mm}^2}$의 면적으로 선택한 후, 시간 경과에 따른 신호강도의 변화를 보여주는 커브를 구하였다 이 영상을 PC로 전송한 후 자체 개발한 영상처리 프로그램과 IDL 소프트웨어를 이용하여 상대적 및 국소 뇌혈류량을 구하였다. 결과: 실험군으로 채택한 가토 총 24마리중 22마리에서 만족할 만한 1-2회의 시간-신호강도 곡선을 얻었다. 획득한 데이터는 두정부 대뇌피질 두 곳과 기저 핵에서 시간의 경과에 따른 신호강도의 변화를 측정하고, 이들 부위의 국소 뇌혈류 용적 및 조영제의 잔류 시간을 구하였다. 평균 국소 뇌혈류량 용적비는 궁륭부 대뇌피질에서는 $0.97{\pm}0.35$, 기저 핵에서는 $0.99{\pm}0.37$이었으며, 조영제의 펑균 잔류시간은 궁룡부 대뇌피질에서는 $9.83{\pm}1.63초$, 기저핵에서는 $9.42{\pm}1.14$초로서 두 부위간에 통계학적으로 유의한 차이는 없었다. 결론: 궁룡부 대뇌피질과 기저 핵에서 평균 국소 뇌혈류량 용적비와 조영제 평균잔류 시간의 차이는 없었다. 그러므로 PWI가 뇌혈류량 측정에 유용하며 허혈성 질환의 조기진단 및 예후 추정에 이용될 수 있다. 향후 정상조직과 뇌경색이 유발 된 조직의 rCBV차이를 비교할 수 있으며, DWI 소견과 경색 환자에 적용하면 뇌혈류 변화 분석에 도움이 될 것으로 사료된다.

  • PDF

Potential Energy Curves and Geometrical Structure Variations for [MX4]2- : M=Ni(II), Pd(II), Pt(II); X=Cl-, Br-) Dissociating into ([MX3]- + X-) : Ab Initio Study

  • Park, Jong-Keun;Kim, Bong-Gon;Koo, In-Sun
    • Bulletin of the Korean Chemical Society
    • /
    • 제26권11호
    • /
    • pp.1795-1802
    • /
    • 2005
  • Potential energy curves and internuclear (M-X) distance variations for dissociation reactions of $[MX_4]^{2-}$ into ($[MX_3]^-$ + $X^-$) have been calculated using ab initio Hartree-Fock (HF), second order M$\ddot{o}$ller-Plesset perturbation (MP2), and Density Functional Theory (DFT) methods with a triple zeta plus polarization (TZP) basis set. The equilibrium geometrical structures of $[MX_4]^{2-}$ are optimized to tetrahedral geometry for $[NiX_4]^{2-}$ and square planar geometry for ($[PdX_4]^{2-}$ and $[PtX_4]^{2-}$). The bond (M-X) distances of $[NiCl_4]^{2-}$, $[NiBr_4]^{2-}$, $[PdCl_4]^{2-}$, $[PdBr_4]^{2-}$, $[PtCl_4]^{2-}$, and $[PtBr_4]^{2-}$ at the DFT level are 2.258, 2.332, 2.351, 2.476, 2.367, and 2.493 $\AA$, respectively. The dissociation energies for the bond dissociation of ($[MX_3]^-$${\cdot}{\cdot}{\cdot}$$X^-$) at the DFT level are found to be 4.73 eV for $[NiCl_4]^{2-}$, 4.89 eV for $[NiBr_4]^{2-}$, 4.93 eV for $[PdCl_4]^{2-}$, 5.57 eV for $[PdBr_4]^{2-}$, 5.44 eV for $[PtCl_4]^{2-}$, and 5.87 eV for $[PtBr_4]^{2-}$. As the (M${\cdot}{\cdot}{\cdot}$X) distance of ($[MX_3]^-$${\cdot}{\cdot}{\cdot}$$X^-$) increases, the distance variation (Rt) of trans (M-X) bond at the trans-position is shorter than those (Rc) of two cis (M-X) bonds at the cisposition. Simultaneously the atomic charge variation of trans-X atom is more positive than those of equilibrium $[MX_4]^{2-}$ structures, while the variation of leaving X group is more positive.

Side-Wall 공정을 이용한 WNx Self-Align Gate MESFET의 제작 및 특성

  • 문재경;김해천;곽명현;임종원;이재진
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 1999년도 제17회 학술발표회 논문개요집
    • /
    • pp.162-162
    • /
    • 1999
  • 초고주파 집적회로의 핵심소자로 각광을 받고 있는 GaAs MESFET(MEtal-emiconductor)은 게이트 형성 공정이 가장 중요하며, WNx 내화금속을 이용한 planar 게이트 구조의 경우 임계전압(Vth:threshold voltage)의 균일도가 우수할 뿐만 아니라 특히 Side-wall을 이용한 self-align 게이트는 소오스 저항을 줄일 수 있어 고성능의 소자 제작을 가능하게 한다.(1) 본 연구의 핵심이 되는 Side-wall을 형성하기 위하여 PECVD법에 의한 SiOx 박막을 증착하고, 건식식각법을 이용하여 SiOx side-wall을 형성하였다. 이 공정을 이용하여 소오스 저항이 낮고 임계전압의 균일도가 우수한 고성능의 self-aligned gate MESFET을 제작하였다. 3inch GaAs 기판상에 이온주입법에 의한 채널 형성, d.c. 스퍼터링법에 의한 WNx 증착, PECVD법에 의한 SiOx 증착, MERIE(Magnetic Enhanced Reactive Ion Etcing)에 의한 Side-wall 형성, LDD(Lightly Doped Drain)와 N+ 이온주입, 그리고 RTA(Rapid Thermal Annealing)를 사용하여 활성화 공정을 수행하였다. 채널은 40keV, 4312/cm2로, LDD는 50keV, 8e12/cm2로 이온주입하였고, 4000A의 SiOx를 증착한 후 2500A의 Side-wall을 형성하였다. 옴익 접촉은 AuGe/Ni/Au 합금을 이용하였고, 소자의 최종 Passivation은 SiNx 박막을 이용하였다. 제작된 소자의 전기적 특성은 hp4145B parameter analyzer를 이용한 전압-전류 측정을 통하여 평가하였다. Side-wall 형성은 0.3$\mu\textrm{m}$ 이상의 패턴크기에서 수직으로 잘 형성되었고, 본 연궁에서는 게이트 길이가 0.5$\mu\textrm{m}$인 MESFET을 제작하였다. d.c. 특성 측정 결과 Vds=2.0V에서 임계전압은 -0.78V, 트랜스컨덕턴스는 354mS/mm, 그리고 포화전류는 171mA/mm로 평가되었다. 특히 본 연구에서 개발된 트랜지스터의 게이트 전압 변화에 따른 균일한 트랜스 컨덕턴스의 특성은 RF 소자로 사용할 때 마이크로 웨이브의 왜곡특성을 없애주기 때문에 균일한 신호의 전달을 가능하게 한다. 0.5$\mu\textrm{m}$$\times$100$\mu\textrm{m}$ 게이트 MESFET을 이용한 S-parameter 측정과 Curve fitting 으로부터 차단주파수 fT는 40GHz 이상으로 평가되었고, 특히 균일한 트랜스컨덕턴스의 경향과 함께 차단주파수 역시 게이트 바이어스, 즉 소오스-드레스인 전류의 변화에 따라 균일한 값을 보였다. 본 연구에서 개발된 Side-wall 공정은 게이트 길이가 0.3$\mu\textrm{m}$까지 작은 경우에도 사용가능하며, WNx self-align gate MEESFET은 낮은 소오스저항, 균일한 임계전압 특성, 그리고 높고 균일한 트랜스 컨덕턴스 특성으로 HHP(Hend-Held Phone) 및 PCS(Personal communication System)와 같은 이동 통신용 단말기의 MMICs(Monolithic Microwave Integrates Circuits)의 제작에 활용될 것으로 기대된다.

  • PDF

저가의 머신 비전 카메라를 이용한 2차원 진동의 측정 및 교정 (Measurement of two-dimensional vibration and calibration using the low-cost machine vision camera)

  • 김서우;이정권
    • 한국음향학회지
    • /
    • 제37권2호
    • /
    • pp.99-109
    • /
    • 2018
  • 현존하는 진동 측정 센서는 정밀도 면에서는 대부분의 진동을 측정하기에 충분하나, 센서 한 개로 하나의 지점이나 방향에 한정하여 측정할 수밖에 없다는 단점을 갖고 있다. 반면 카메라의 경우, 정밀도나 측정 가능한 주파수 영역의 면에서는 다소 불리하지만, 한 번에 광범위한 영역의 진동을 측정할 수 있고 가격 면에서 유리하며 다자유도의 진동을 동시에 측정할 수 있다는 큰 장점을 갖고 있다. 본 연구에서는 저가의 머신 비전 카메라가 진동 측정 센서로서 어느 정도의 오차 범위 내에서 진동을 측정할 수 있는지 알아본 후, 실제 외팔보의 진동을 측정하였다. 카메라의 2차원 평면 이미지는 두 방향의 직선 운동과 한 방향의 회전 운동을 나타낼 수 있다. 먼저 단일 점의 진동을 카메라로 측정하고, LDV(Laser Doppler Vibrometer) 측정을 기준으로 한 카메라 측정의 오차를 실험적으로 교정하였다. 다음으로 다중점의 진동을 한 번에 측정하여 회전 진동과 외팔보 전체 형상의 진동을 측정하였다. 외팔보 전체 형상 진동은 주파수와 시간 영역 모두에 대하여 분석하였다.

비균일 진주층 모사 다층형 복합재료의 내충격성에 관한 수치해석 (Numerical Study on Impact Resistance of Nonuniform Nacre-patterned Multi-layer Structures)

  • 이태희;고권환;홍정욱
    • 한국전산구조공학회논문집
    • /
    • 제35권4호
    • /
    • pp.215-226
    • /
    • 2022
  • 우수한 역학적 성능을 가진 생물체의 구조를 모방하여 고성능의 복합재료를 개발하려는 노력이 최근 활발히 이뤄지고 있다. 진주층 구조는 구성재료 대비 월등히 높은 파괴인성을 지닌다는 점에서 촉망받는 자연 모사 구조 중 하나이다. 하지만, 진주층 모사 구조의 형상이 변형될 때 구조의 충격성능이 어떻게 달라지는지에 관한 연구는 아직 충분히 진행되지 않았다. 본 연구에서는 무작위로 변형된 진주층 모사 복합재의 수치모델을 개발하고 충격성능을 분석하였다. 먼저, 균일한 진주층 모사 패턴에서 플레이트 판의 평면 크기를 무작위로 변형하는 알고리즘을 개발하고 이를 활용하여 불균일한 진주층 패턴 모사 구조를 모델링하였다. 그 후, 낙하충격 시뮬레이션을 수행하고 해당 모델의 충격거동을 에너지 흡수율과 본 미세스 응력 분포, 충격력-시간 그래프를 활용하여 평가하였다. 수치해석결과를 바탕으로, 충돌 범위 주변 플레이트 판의 기하학적 형상이 불균일할수록 진주층 모사 구조의 내충격성이 저하됨을 입증하였다. 이러한 진주층 모사 형상에 대한 심층적인 이해는 진주층 모사 구조의 최적설계를 수립하는 데 효율적으로 활용될 수 있을 것으로 기대된다.

전자선 빔 치료 시 삼차원프린터를 이용하여 제작한 환자맞춤형 볼루스의 유용성 및 선량 정확도 평가 (Efficacy and Accuracy of Patient Specific Customize Bolus Using a 3-Dimensional Printer for Electron Beam Therapy)

  • 최우근;전준철;주상규;민병준;박수연;남희림;홍채선;김민규;구범용;임도훈
    • 한국의학물리학회지:의학물리
    • /
    • 제27권2호
    • /
    • pp.64-71
    • /
    • 2016
  • 삼차원 프린터(3DP)를 이용하여 환자맞춤형 전자선 치료용 볼루스(patient specific customized bolus, PSCB)를 제작하는 절차를 고안하고 제안된 방법으로 제작한 PSCB의 선량 정확도를 평가했다. 치료계획장치에서 치료계획표적용적(PTV)에 적합한 전자선 빔과 조사면 크기를 선택하고 초기 선량계산을 수행했다. 계산된 선량분포를 기반으로 PSCB를 그리고 재계산을 수행했다. 수 차례 반복을 통해 최상의 PSCB를 설계하고 설계된 윤곽자료를 DICOMRT 프로토콜을 이용해 자체 제작한 변환프로그램으로 전송했다. PSCB의 윤곽자료는 자체 변환프로그램을 이용해 3DP에서 인식 가능한 파일(STL 포맷)로 변환한 후 3DP를 이용해 제작했다. PSCB의 유용성을 검증하기 위해 2명의 가상 환자(오목, 볼록 유형)를 생성했고 각각의 환자에 가상의 PTV와 정상장기(OAR)을 생성했다. 3D-PSCB 를 사용했을 때와 사용하지 않았을 때의 선량체적히스토그램(DVH)와 선량 특성을 비교했다. 3D-PSCB 제작의 정확도를 분석하기 위해 필름 선량측정을 통해 선량 정확도를 평가했다. 치료계획 결과와 필름을 이용한 선량분포를 중첩한 후 빔 중심축에서의 심부선량곡선을 구했고 감마분석(3% 선량 오차와 3 mm 거리오차)을 수행 했다. 2명의 가상환자 모두에서 PSCB를 사용한 경우 PTV 선량은 큰 차이를 보이지 않았다. PSCB를 사용할 경우 PSCB를 사용하지 않는 경우에 비해 OAR의 최대 선량, 최소선량, 평균선량은 각각 평균 9.7%, 36.6%, 28.3% 감소했다. 처방선량의 90% 선량($V_{90%}$)을 받는 OAR의 용적은 PSCB를 적용할 경우 약 99% 낮아졌다(14.40 vs $0.1cm^3$). 또한 처방선량의 80% 선량을 받는 OAR 체적도 PSCB를 사용할 경우 약 91% 줄었다(42.6 vs $3.7cm^3$). 감마분석 결과(3%, 3 mm) 오목 및 볼록 볼루스를 적용한 경우 각각 95%, 98% 통과율(pass rate)을 보였다. 3DP를 이용해 PSCB를 제작하는 절차를 정립하고 선량적 정확도를 평가해서 임상적용이 가능한 만족할 만한 결과를 얻었다. 3DP 기술의 빠른 발전에 힘입어 PSCB의 임상적용이 좀 더 쉬워지고 적용대상이 확장될 것으로 생각된다.