• Title/Summary/Keyword: Placements

Search Result 152, Processing Time 0.022 seconds

Efficient Global Placement Using Hierarchical Partitioning Technique and Relaxation Based Local Search (계층적 분할 기법과 완화된 국부 탐색 알고리즘을 이용한 효율적인 광역 배치)

  • Sung Young-Tae;Hur Sung-Woo
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.42 no.12
    • /
    • pp.61-70
    • /
    • 2005
  • In this paper, we propose an efficient global placement algorithm which is an enhanced version of Hybrid Placer$^{[25]}$, a standard cell placement tool, which uses a middle-down approach. Combining techniques used in the well-known partitioner hMETIS and the RBLS(Relaxation Based Local Search) in Hybrid Placer improves the quality of global placements. Partitioning techniques of hMETIS is applied in a top-down manner and RBLS is used in each level of the top-down hierarchy to improve the global placement. The proposed new approach resolves the problem that Hybrid Placer seriously depends on initial placements and it speeds up without deteriorating the placement quality. Experimental results prove that solutions generated by the proposed method on the MCNC benchmarks are comparable to those by FengShui which is a well known placement tool. Compared to the results of the original Hybrid Placer, new method is 5 times faster on average and shows improvement on bigger circuits.

Accuracy and Safety of Bedside External Ventricular Drain Placement at Two Different Cranial Sites : Kocher's Point versus Forehead

  • Park, Young-Gil;Woo, Hyun-Jin;Kim, Il-Man;Park, Jae-Chan
    • Journal of Korean Neurosurgical Society
    • /
    • v.50 no.4
    • /
    • pp.317-321
    • /
    • 2011
  • Objective : External ventricular drain (EVD) is commonly performed with a freehand technique using surface anatomical landmarks at two different cranial sites, Kocher's point and the forehead. The aim of this study was to evaluate and compare the accuracy and safety of these percutaneous ventriculostomies. Methods : A retrospectively review of medical records and head computed tomography scans were examined in 227 patients who underwent 250 freehand pass ventriculostomy catheter placements using two different methods at two institutions, between 2003 and 2009. Eighty-one patients underwent 101 ventriculostomies using Kocher's point (group 1), whereas 146 patients underwent 149 forehead ventriculostomies (group 2). Results : In group 1, the catheter tip was optimally placed in either the ipsilateral frontal horn or the third ventricle, through the foramen of Monro (grade 1) in 82 (81.1%) procedures, in the contralateral lateral ventricle (grade 2) in 4 (3.9%), and into eloquent structures or non-target cerebrospinal space (grade 3) in 15 (14.8%). Intracerebral hemorrhage (ICH) >1 mL developed in 5 (5.0%) procedures. Significantly higher incidences of optimal catheter placements were observed in group 2. ICH>1 mL developed in 11 (7.4 %) procedures in group 2, showing no significant difference between groups. In addition, the mean interval from the EVD to ventriculoperitoneal shunt was shorter in group 2 than in group 1, and the incidence of EVD-related infection was decreased in group 2. Conclusion : Accurate and safe ventriculostomies were achieved using both cranial sites, Kocher's point and the forehead. However, the forehead ventriculostomies provided more accurate ventricular punctures.

Analysis of Influencing Factors of Traveler Detour Making Behavior for Providing Freeway VMS Information (고속도로 VMS 정보 제공 시 우회율 산출에 관한 연구)

  • Choi, Jai-Sung;Sung, Hyun-Jin;Kim, Sang-Youp;Park, Jun;Kang, Weon-Eui
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.9 no.3
    • /
    • pp.41-50
    • /
    • 2010
  • This paper presents an investigation result that is made to determine dominant influencing factors and their specific impacts on motorist detour makings for VMS placements on freeway. This was necessary to provide engineers with a tool for evaluating VMS cost-effectiveness and its feasibility. This research found that additional travel time delay is the most influential variable in determining motorist detour makings. Also, more than 70% freeway motorists recognize the adjacent national roads as their detour routes, and both AADT and the distance to the entering point of the detour path are found to be dominating factors. Motorist detour ratio model by VMS placement on freeway is developed based on the Stated Preference. In model validation, actual detour making behaviors observed by the Revealed Preference values verify the detour ratio on the Stated Preference. These research findings should be useful for cost-effective placements of VMS on freeway, and it is recommended that the results be tested by practicing engineers in the ITS sector.

Nonparametric multiple comparison method in one-way layout based on joint placement (일원배치모형에서 결합위치를 이용한 비모수 다중비교법)

  • Seok, Dahee;Kim, Dongjae
    • The Korean Journal of Applied Statistics
    • /
    • v.30 no.6
    • /
    • pp.1027-1036
    • /
    • 2017
  • Multiple comparisons are required to confirm whether or not something is significant if the null hypothesis to test whether the difference between more than three treatments is rejected in a one-way layout. There are both parametric multiple comparison method Tukey (1953) and Nonparametric multiple comparison method based on Kruskal-Wallis (1952).This procedure is applied to a mixed sample of all data and then an average ranking is used for each of three or more treatments. In this paper, a new nonparametric multiple comparison procedure based on joint placements for a one-way layout as extension of the joint placements described in Chung and Kim (2007) was proposed. Monte Carlo simulation is also adapted to compare the family wise error rate (FWE) and the power of the proposed method with previous methods.

Comparison of Stability Coefficients of Radial Shape Armor Blocks Depending on Placement Methods (피복 방법에 따른 방사형 소파 블록의 안정계수 비교)

  • Min, Eun-Jong;Cheon, Se-Hyeon;Suh, Kyung-Duck
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.27 no.2
    • /
    • pp.135-141
    • /
    • 2015
  • In this study, two different uniform placement methods are proposed for each of Tetrapod, Rakuna-IV, and Dimple armoring a rubble mound breakwater, and the corresponding stability coefficients are determined by hydraulic experiments. The Tetrapod and Rakuna-IV show similar stability coefficients regardless of the placement methods, whereas the Dimple shows somewhat different stability coefficients depending on the placement methods. It is shown that the Dimple gives the largest stability coefficient, whereas the Tatrapod gives the smallest value. The uniform placement methods of Tatrapod and Rakuna-IV give slightly larger stability coefficients than the random placement, whereas the uniform placements of Dimple give much larger stability coefficients than the random placement. However, the small void ratio of uniform placements of Dimple requires attention because the blocks would behave like single layer system blocks so that brittle failure could occur.

The Analysis of Transmission Power Control Model for Energy Efficiency in Body Sensor Systems (에너지 효율을 위한 인체 센서 시스템의 전송 전력 조절 모델 분석)

  • Hong, Jin-A;Kim, Namgi
    • Journal of Internet Computing and Services
    • /
    • v.15 no.4
    • /
    • pp.1-8
    • /
    • 2014
  • In wireless body sensor system(WB-SNSs), unlike existing sensor network system, the size of device is small and amount of battery is considerably limited. And various channel environments can be made by link channel characteristic, human movements, sensor placements, transmission power control(TPC) algorithms and so on. In this paper, therefore we take diverse experiments with totally considerated environments to overcome these restrictions and to manage the energy efficiently and find the value of target received signal strength indicator(RSSI) based on diverse factors such as human movements, sensor placements, and TPC algorithms. And we conduct analysis in terms of energy consumption and packet delivery rate(PDR) based on the experimental results. Through these analysis, we compare and evaluate the efficiency according to setup values of Target RSSI and Target RSSI range suitable for wireless body sensor network system.

A Method for Challenge Placement to Set the Level of Difficulty in a Car Driving Game (자동차 주행 게임에서의 난이도 설정을 위한 도전 배치 방법)

  • Kim, Sangchul;Park, Dosaeng
    • Journal of Korea Game Society
    • /
    • v.15 no.4
    • /
    • pp.169-178
    • /
    • 2015
  • Providing various levels of difficulty of game play is one of important considerations in game development. In this paper, we propose a method for obtaining the challenges that will be placed on the track of an one-player car driving game. Herein challenges denote obstacles on the track, and the level of difficulty is represented by an estimated time needed for driving one lap of the track. In the proposed method, the problem for finding challenge placement is modeled as an IP(Integer Programming) one, and then LP relaxation and Simultaneous Annealing are employed to find a solution. To the experiment with the proposed method, we can obtain challenge placements to approximately meet given target driving times. Also, after practically driving on the track where those obtained challenges are being placed, it is seen that the average driving times approximate the target driving times of those challenge placements. Our method can allow game play with various levels of difficulty so that the users' interest and the level of immerse are expected to be raised.

Five-year retrospective radiographic follow-up study of dental implants with sandblasting with large grit, and acid etching-treated surfaces

  • Kim, Hak-Kyun;Lee, Eun-Young;Kim, Jae-Jin
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.41 no.6
    • /
    • pp.317-321
    • /
    • 2015
  • Objectives: The purpose of this study is to evaluate five-year radiographic follow-up results of the Korean sandblasting with large grit, and acid etching (SLA)-treated implant system. Materials and Methods: The subjects of the study are 54 patients who have been followed-up to date, of the patients who underwent implant surgery from May 1, 2009 to April 30, 2011. In all, 176 implant placements were performed. Radiographs were taken before the first surgery, immediately after the first and second surgeries, immediately and six months after the final prosthesis installation, and every year after that. Bone loss was evaluated by the method suggested by Romanos and Nentwig. Results: A total of 176 implant placements were performed - 122 in men and 54 in women. These patients have been followed-up for an average of 4.9 years. In terms of prosthetic appliances, there were 156 bridges and 20 single prostheses. Nine implants installed in the maxillary molar area, three in the mandibular molar area and two in the maxillary premolar area were included in group M, with bone loss less than 2 mm at the crestal aspect of the implant. Of these, eight implants were single prostheses. In all, six implants failed - four in the mandible and two in the maxilla. All of these failures occurred in single-implant cases. The implant survival rate was 98.1% on the maxilla and 94.3% on the mandible, with an overall survival of 96.6%. Conclusion: Within the limitations of this study, implants with the SLA surface have a very superior survival rate in relatively poor bone environments such as the maxilla.

Development of New Cancer Therapy and Its Physics

  • Oh, Hung-Kuk;Jeong, Jin-Ha
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2001.05a
    • /
    • pp.147-155
    • /
    • 2001
  • Nasucon lamp and Russian ones, which are coated with some special materials on the glass bulb, gave good clinical results for a cancer therapy. They are experimentally studied with Automatic Bioelectric Response Recorder on the six placements of the electrodes (two feet, two hands and two foreheads). They reduced the current rather than the control (natural) state. However infrared lamp and Chinese God light did not reduced the value current. Hemoglobin in blood. Brown gas, Ti$_3$SiC$_2$ and Nasucon have planar crystallizing $\pi$-bonding bonding layer and covalent bonding one in sequence commonly and thus the alternating magnetic fields are protected. Nasucon lamp and Russian ones utilized electric bulbs in order to generate alternating magnetic fields and to produce absorbing force.

  • PDF