• Title/Summary/Keyword: Placement distance

Search Result 142, Processing Time 0.024 seconds

Horizontal alteration of anterior alveolar ridge after immediate implant placement: A retrospective cone beam computed tomography analysis

  • Hyun, Young Keun;Lee, Chung Yun;Keerthana, Subramanian;Ramasamy, Selvaponpriya;Song, So-Yeon;Shim, Ji Suk;Ryu, Jae Jun
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.2
    • /
    • pp.117-125
    • /
    • 2021
  • PURPSE. The aim of this study was to evaluate the labio-lingual alterations of the alveolar bone where the implant was placed immediately after tooth extraction. MATERIALS AND METHODS. Implants were placed immediately after tooth extraction on anterior alveolar ridges in the maxilla and mandible. The pinguide system was used to help determine the location and path of implants during the surgical process. The horizontal distance from implants to the outer border of alveolar bone was measured at the rim and middle of the implants in the cone beam computed tomography images. The alteration of alveolar bone was evaluated comparing the horizontal distances measured immediately after surgery and 3 months after surgery. RESULTS. The results show that more resorption occurred towards the labial bone than the lingual bone in the maxilla. A similar amount of labial and lingual bone resorption was observed in the mandible. CONCLUSION. Considering the horizontal alteration of alveolar bone, labio-lingual positioning of the implant towards the lingual bone in the maxilla and at the center of the alveolar ridge in the mandible is recommended when it is placed immediately after tooth extraction.

Knowledge Distribution in the Science and Technology Space (Case of the Eurasian Economic Union)

  • Farida ALZHANOVA;Gulnaz ALIBEKOVA;Farkhat DNISHEV;Nazyken BAGAYEVA
    • Journal of Distribution Science
    • /
    • v.21 no.9
    • /
    • pp.81-91
    • /
    • 2023
  • Purpose: The article aims to assess the possibilities and contribution of countries to the creation and distribution of knowledge circulating in the scientific and technological space of the EAEU. Research design, data, and methodology: To understand the conditions and possibilities for the distribution of knowledge, the methodology of the quality of economic space used. The space is considered through density, placement, connectedness, and asymmetry. Used bibliometric analysis, balance of payments analysis, and integration indicators. Results: The study showed that low barriers, including language, created visible advantages in the mutual distribution of knowledge. However, the geo-technological space of the EAEU is polarised and has differences in the density and distribution of scientific resources. Asymmetries are shown in the distance between countries in multidirectional trends. Cooperation between countries has a different level of interaction. Conclusions: The internal resources of the geo-technological space of the EAEU are limited, and most of the needs are covered by external sources. Some mechanisms of the scientific policy of countries in scientific careers act as «demotivates» for distributing knowledge within the EAEU. Countries need to improve the quality of services and trade data to better understand technology distribution processes through bilateral channels.

Finding the optimum shape of the energy dissipator to minimize the impact force due to the dam break flow

  • Asrini Chrysanti;Sangyoung Son
    • Ocean Systems Engineering
    • /
    • v.14 no.2
    • /
    • pp.157-169
    • /
    • 2024
  • The sudden release of water from a dam failure can trigger bores on a flat surface and exert substantial impact forces on structures. This flow poses a high-risk flood hazard to downstream urban areas, making it imperative to study its impact on structures and devise effective energy dissipators to mitigate its force. In this study, a combination of Genetic Algorithm optimization and numerical modeling is employed to identify the optimal energy dissipator. The analysis reveals that a round arc-shaped structure proves most effective, followed by a triangular shape. These shapes offer wide adaptability in terms of structure dimensions. Structures with higher elevation, especially those with round or triangular shapes, demonstrate superior energy dissipation capabilities. Conversely, square-shaped structures necessitate minimal height to minimize impact forces. The optimal width for dissipating energy is found to be 0.9 meters, allowing for effective wave run-up and propagation. Furthermore, the force exerted on structures increases with higher initial water levels, but diminishes with distance from the dam, highlighting the importance of placement in mitigating impact forces.

Effect of rhPMP-2 coated implants on alveolar ridge augmentation in dogs (성견에서 골형성단백질이 코팅된 임플란트가 치조골 증대에 미치는 영향)

  • Park, Chan-Kyung;Kim, Jong-Eun;Shin, Ju-Hee;Ryu, Jae-Jun;Huh, Jung-Bo;Shin, Sang-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.3
    • /
    • pp.202-208
    • /
    • 2010
  • Purpose: This study was aimed to evaluate the effect of rhPMP-2 coated implants on alveolar ridge augmentation in dogs. Materials and methods: Six Beagle dogs were used in this study. Six 8.0 mm long anodized surface titanium implants were placed 5 mm into the mandibular alveolar ridge following 6 month of healing period after extraction. Each animal received three implants coated with rhBMP-2 and three uncoated control implants using the randomized split-mouth design. Radiographic examinations were undertaken immediately at implant placement (baseline), at weeks 4 and 8 after implant placement. The amount of bone augmentation was evaluated by measuring the distance from the uppermost point of the coverscrew to the marginal bone. Implant Stability Quotient (ISQ) values were measured immediately at implant placement and 8 weeks after implant placement. For the statistical analysis, Man-Whitney ranksum test and Wilcoxon signed rank test of SPSS 12.0 software were used (P=.05). Results: The BMP group exhibited radiographic vertical bone augmentation about $0.6{\pm}0.7$ mm at 8 weeks later while controls showed bone loss about $0.4{\pm}0.6$ mm. There was significant difference among the rhBMP-2 group and controls in bone level change (P<.05). The ISQ values were significantly higher in the BMP-2 group than the control group at 8 weeks later (P<.05), while there was no significant difference at surgery. Conclusion: Within the limitation of this study, the rhBMP-2 coated on anodized implant could stimulate vertical alveolar bone augmentation, which may increase implant stability significantly on completely healed alveolar ridge.

Finite element stress analysis according to the point and surface occlusal loads on the implant prosthesis (임플란트 보철물의 점하중과 면하중에 따른 유한요소법적 응력 분석)

  • Choi, Min-Ho;Kang, Jae-Suek;Boo, Soo-Bung;Oh, Snag-Ho;An, OK-Ju;Kang, Dong-Wan
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.20 no.2
    • /
    • pp.83-94
    • /
    • 2004
  • The purpose of this study was to compare the distributing pattern of stress according to the types of occlusal load on the finite element models of the splinted implant prostheses. The finite element model was designed with the parallel placement of two fixtures ($4.0mm{\times}11.5mm$) on mandibular first and second molars. The cemented crowns for mandibular first and second molars were made. Three-dimensional finite element model was created with the components of the implant, surrounding bone and cemented crowns. Two types of occlusal load, the point load and the surface load within 0.5 mm radius circle, were applied to the finite element models with 200N magnitude in axial(along the long axis of the implant and oblique(angulation of $30^{\circ}$ to the long axis) directions perpendicular to cuspal incline. Loads were positioned from the center of central fossa and to distance of 2 mm and 4 mm apart from the center of central fossa. Von-Mises stresses were recorded and compared in the fixtures and sections. The results were as following : 1. Under axial loading at the central fossa, the stress was distributed along the fixture except for the apical portion, not relative to both point & surface contacts. 2. With offset distance increasing, the highest stresses were concentrated in the neck portion of the fixture. 3. The maximum von Mises stress under the oblique load was greater than that under the axial load. 4. Under the oblique load, the highest stress were concentrated in the buccal side and lingual neck portion of the fixture with offset distance increasing. The results had a tendency to increase the stress on the neck portion of fixture with the offset and oblique loads increasing. The design of occlusal scheme should be allowed to distribute stress axially in maximum intercuspation and to decrease the angulation of cuspal incline.

Spatial Information Search Features Shown in Eye Fixations and Saccades (시선의 고정과 도약에 나타난 공간정보 탐색 특성)

  • Kim, Jong-Ha
    • Korean Institute of Interior Design Journal
    • /
    • v.26 no.2
    • /
    • pp.22-32
    • /
    • 2017
  • This research is to analyze the spatial information search features which shown by Eye fixation and movement and conducted eye tracking experiment for targeting sports shop spatial images which it are same but looks different. This is able to find out the eye movement feature according to placement of goods from the eye movement and movement distance of spatial visitor, and the result can be defined as following. First, the whole original-reverse left / right images have a higher number of observations in the [IN] area than in the [OUT] area. This is because after eye taking high observations in LA area of [IN] have been jump-over [OUT], performed search activities in low eye fixation without high eye fixation. Second, there was a difference in the frequency of the observation data as the composition of the images changed. The original image has been often fixed the eyes in LA area, and the one that has been observed for a long time is reverse left / right image. Also, fixation point was shown higher at the reverse left / right image as jump-over from [OUT] area to [IN] area. If LA area seen as reverse left / right image, it is located in right-hand side. The case where the dominant area is on the right side has a characteristic that the eye fixation is longer. This can be understand that the arrangement of products for attract the customer's attention in the commercial space might be more effective when it is on the right side. Third, the moving distance(IN ${\rightarrow}$ OUT) of the sight pointed to external from LA area was long in the both original-reverse left / right images, but it is no relation with search direction([IN${\rightarrow}$OUT] [IN${\rightarrow}$OUT]) of the sight. In other words, the sight that entered in LA area can be seen as visual perception activity for re-searching after big jump-over, in the case go in to outward (OUT area) after searching for more than certain time. The fact that the moving distance of eye is relatively short in the [IN ${\rightarrow}$ OUT] process considered as that the gaze that stays outside the LA area naturally enters in to LA area.

Anatomic study of the incisive canal in relation to midpalatal placement of mini-implant (정중구개부의 미니 임플랜트 식립과 관련된 절치관의 해부학적 연구)

  • Kim, Sung-Jin;Lim, Sung-Hoon
    • The korean journal of orthodontics
    • /
    • v.39 no.3
    • /
    • pp.146-158
    • /
    • 2009
  • Objective: The purpose of this study was to reveal the position of the incisive foramen in relation to the incisive papilla and cusp tips. Methods: Plaster models and CT images of 25 adult orthodontic patients were used to measure the width of the incisive canal and positions of the anterior and posterior borders of the incisive foramen in relation to the incisive papilla. Results: The palatal surface distance from the interdental papilla between the maxillary central incisors to the posterior border of the incisive foramen along the palatal surface was 1.7 fold of the distance from the interdental papilla between the central incisors to the posterior border of the incisive papilla. The distance between the posterior border of the incisive papilla and posterior border of the incisive foramen along the palatal surface was 6.15 ${\pm}$ 1.75 mm. The anteroposterior position of the posterior border of the incisive foramen was slightly anterior to the lingual cusp tips of the maxillary 1st premolars. The width of the incisive foramen was 4.03 ${\pm}$ 0.64 mm, therefore it is recommended to position the mini-implant more than 3 mm laterally when placing a mini-implant lateral to the incisive foramen, from the center. Conclusions: These results can be used as a reference in presuming the position of the incisive foramen when placing mini-implant in the anterior palate area.

A STUDY OF THE CRAZING OF TOOTH STRUCTURE ASSOCIATED WITH PLACEMENT OF PINS (Pin장착시(裝着時)에 치질귀열(齒質龜裂)에 미치는 영향(影響)에 관(關)한 연구(硏究))

  • Na, Young-Min;Choi, Ho-Young;Min, Byung-Soon;Park, Sang-Jin
    • Restorative Dentistry and Endodontics
    • /
    • v.11 no.1
    • /
    • pp.33-41
    • /
    • 1985
  • The purpose of this study was to determine the extent of tooth structure crazing when pinhole were drilled in dentin at various distances from the dentionenamel junction, and when pins were inserted by hand wrench and Auto-klutch handpiece. Sixty freshly extracted teeth were embedded in blocks of cold-curing acrylic resin to a level 1mm apical to the cementoenamel junction, the crown of the teeth were removed to a level 1.5mm coronal to the cementoenamel junction. After being sectioned, the cut surface of the teeth were smoothed, and they were divided into 4 groups. Group I : 4 pinholes were drilled with self-threading Minim spiral drill and pins were inserted with hand wrench in fifteen teeth. Group II : 4 pinholes were drilled with self-threading Minim spiral drill and pins were inserted with Auto-klutch handpiece in fifteen teeth. Group III : 4 pinholes were drilled with self-threading Regular spiral drill and pins were inserted with hand wrench in fifteen teeth. Group IV : 4 pinholes were drilled with self-threading Regular spiral drill and pins were inserted with Auto-klutch handpiece in fifteen teeth. The cut surface were then examined microscopically for the presence or absence of craze line. The results were as follows: 1. The self-threading Minim pin groups (Group I & II) produced less craze lines than did the self-threading Regular pin groups (Group III & IV). 2. In the self-threading Minim pin groups, there was more craze lines with hand wrench (Group I) than with Auto-klutch handpiece (Group 11). 3. In the self-threading Regular pin groups, there was more craze lines with hand wrench (Group III) than with Auto-klutch handpiece (Group IV). 4. Placement of the pinhole at 0.0mm from the dentionenamel junction produced more craze lines than placed at 0.5mm, 1.0mm (p<0.05), however there was no statistically significant between the 0.5mm and 1.0mm distance.

  • PDF

Pin Distribute Method of Twist Cable at Military Unmanned Vehicle Wiring Unit Connector (군용 무인 이동체 배선장치 커넥터에서 트위스트 케이블 핀 배치 최적화 방안)

  • Eun, Hee-hyun;Roh, Dong-gyu;Kwak, Gyu-min;Kim, Jae-seung;Lee, Chul
    • Journal of Advanced Navigation Technology
    • /
    • v.24 no.4
    • /
    • pp.245-250
    • /
    • 2020
  • Currently, unmanned military vehicles under development in Korea have more devices to carry out various missions, and interface cables between them are also increasing. In addition, due to a small space problem inside the unmanned vehicle, devices are required to be miniaturized and integrated. For two reasons, connectors also need to be selected, which makes them vulnerable to noise due to the closer distance between the pins. In this paper, we analyzed how much the magnetic field produced by noise at the connector pin where cable twist is released affects the surrounding pin and presented the guide for optimal pin placement. First, the effect of magnetic field is greater than the crosstalk between pin and pin. Second, the magnetic field on both sides between + and - is strong when approaching one step with noise source. Third, the magnetic field strength is improved when setting the ground pin as the ground pin between the noise and the original signal when approaching the A noise source and the two steps. Fourth, in the case of a differential mode communication, the optimal placement area of the sensitive signal was presented according to positions Tx± and Rx±.

A New Anterior Approach for Fluoroscopy-guided Suprascapular Nerve Block - A Preliminary Report -

  • Kang, Sang-Soo;Jung, Jae-Woo;Song, Chang-Keun;Yoon, Young-Jun;Shin, Keun-Man
    • The Korean Journal of Pain
    • /
    • v.25 no.3
    • /
    • pp.168-172
    • /
    • 2012
  • Background: The aim of the study was to investigate the feasibility of fluoroscopy-guided anterior approach for suprascapular nerve block (SSNB). Methods: Twenty patients with chronic shoulder pain were included in the study. All of the nerve blocks were performed with patients in a supine position. Fluoroscopy was tilted medially to obtain the best view of the scapular notch (medial angle) and caudally to put the base of coracoid process and scapular spine on same line (caudal angle). SSNB was performed by introducing a 100-mm, 21-gauge needle to the scapular notch with tunnel view technique. Following negative aspiration, 1.0 ml of contrast was injected to confirm the scapular notch, and 1 % mepivacaine 2 ml was slowly injected. The success of SSNB was assessed by numerical rating scale (NRS) before and after the block. Results: The average NRS was decreased from $4.8{\pm}0.6$ to $0.6{\pm}0.5$ after the procedure (P < 0.05). The best view of the scapular notch was obtained in a medial angle of $15.1{\pm}2.2$ ($11-19^{\circ}$) and a caudal angle of $15.4{\pm}1.7^{\circ}$ ($12-18^{\circ}$). The average distance from the skin to the scapular notch was $5.8{\pm}0.6$ cm. None of the complications such as pneumothorax, intravascular injection, and hematoma formation was found except one case of partial brachial plexus block. Conclusions: SSNB by fluoroscopy-guided anterior approach is a feasible technique. The advantage of using a fluoroscopy resulted in an effective block with a small dose of local anesthetics by an accurate placement of a tip of needle in the scapular notch while avoiding pneumothorax.