• Title/Summary/Keyword: Placement Height

Search Result 169, Processing Time 0.029 seconds

Differential temperature fire detector analysis of comparative study based on sensor installation (차동식 열감지기 설치기준 비교분석에 관한 연구)

  • Hwang, Dong-Hwan;Yang, Kwang Mo;Kang, Kyung-Sik
    • Journal of the Korea Safety Management & Science
    • /
    • v.16 no.4
    • /
    • pp.379-389
    • /
    • 2014
  • Fire detectors are designed to minimize loss of life from a fire alarm system as an alarm to help evacuate more quickly until the completion of the evacuation alarm should be continued. the purpose of such alarms in order to achieve the characteristic fire heat release rate reaches a certain level, or when a certain time has elapsed, when the heat detector is to be alarms to answer. Requires a quick response, it is desirable to install the sensor as much as possible, but taking into account the cost of installation problems by engineering approach to minimize the quantity and rapidity of detection capability should be increased. In order to increase the rapidity of fire detectors in a room according to the height of the sensing period is to be maintained the optimum distance of the fire detector detects characteristics should be considered. Differential spot-type heat detectors installed domestic basis, depending on the type of sensor that can detect one sensor area is limited and less than 4m ceiling height regulations and simply double the number in excess of 4m and intended to be installed.

MEASUREMENT OF MAXILLARY SINUS VOLUME FOR THE PLACEMENT OF GRAFT MATERIAL - A CASE CONTROL STUDY USING CT IMAGE (상악동 골이식술을 위한 이식재의 부피 측정 - CT를 이용한 환자 대조군 연구)

  • Kim, Hyung-Wook;Lee, Seul-Ki;Chung, Jae-An;Shin, Jin-Eob;Um, Yun-Sub;Kim, Ki-Young;Kim, Jong-Sik;Song, Yun-Jung;Hong, Soon-Min;Park, Jun-Woo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.33 no.5
    • /
    • pp.511-517
    • /
    • 2007
  • Purpose: The aim of this study is to determine whether a difference in the amount of bone graft material is needed between edentulous patients and dentulous patients and to calculate the amount of augmentation for a sinus lift procedure. Methods: 19 patients(20 sinuses) were included to measure maxillary sinus volume. Facial CT scanning was performed using MX 8000 IDT CT devices(Philips, USA). And it was used for IDLvm(The IDL Virtual Machine) 6.0, CT Volume Analyzer Ver 2.3 program to measure maxillary sinus volumes Results: At edentulous patients, volumes(mean${\pm}SD$) of the inferior portion of the sinuses were $0.56{\pm}0.13cm^3$(5mm height), $2.35{\pm}0.57cm^3$(10mm height), $4.85{\pm}1.10cm^3$(15mm height). At dentulous patients, volumes(mean${\pm}SD$) of the inferior portion of the sinuses were $0.41{\pm}0.18cm^3$(5mm height), $1.76{\pm}0.42cm^3$(10mm height), $3.80{\pm}0.84cm^3$ (15mm height). A significant correlation was found between augmentation height(5mm, 10mm, 15mm) and the calculated sinus volume.(p=0.027, p=0.018, p=0.044) Conclusions: A significant correlation was found between augmentation height(5mm, 10mm, 15mm) and the calculated sinus volume. Detailed preoperative knowledge of sinus lift augmentation volume is helpful in determining the appropriate amount of the bone graft material.

The retrospective study of survival rate of implants with maxillary sinus floor elevation (상악동 거상술을 동반한 상악구치부에 식립된 임플란트 생존율에 대한 후향적 연구)

  • Kim, Beom-Jin;Lee, Jae-Hoon
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.36 no.2
    • /
    • pp.108-118
    • /
    • 2010
  • Introduction: Maxillary posterior region, compared to the mandible or maxillary anterior region, has a thin cortical bone layer and is largely composed of cancellous bone, and therefore, it is often difficult to achieve primary stability. In such cases, sinus elevation with bone graft is necessary. Materials and Methods: In this research, 121 patients who had implant placement after bone graft were subjected to a follow-up study of 5 years from the moment of the initial surgery. The total survival rate, 5-year cumulative survival rate and the influence of the following factors on implant survival were evaluated; the condition of the patient (sex, age, general body condition), the site of implant placement, diameter and length of the implant, sinus elevation technique, closure method for osseous window, type of prosthesis and opposing teeth. Results: 1. The 5-year cumulative survival rate of total implants was 90.5%, there was no significant difference between sex, age, the site of implant placement, diameter and length of the implant, sinus elevation technique, and the type of opposing teeth. 2. Patients with diabetes mellitus < osteoporosis and smooth-surfaced machined group < hydroxyapatite (HA)-treated group and homogenous demineralized freeze dried allogenic bone (DFDB) bone graft only group had significantly lower survival rate. 3. With less than 4 mm of residual alveolar ridge height, lateral approach without closing the osseous window resulted in a significantly lower survival rate. 4. Restoration of a single implant showed a significantly lower survival rate, compared to cases where the superstructure was joined with several implants in the area. Conclusion: Patients with diabetes or osteoporosis need longer period of time for osseointegration compared to the normal, and the dentists must be prudent when choosing a surface treatment type and the bone graft material. Also, as the vertical dimension of the residual alveolar ridge can influence the result, staged implant placement should be considered when it seems difficult for the implant to gain primary stability from the residual bone with less than 4 mm of vertical dimension. It is recommended to obdurate the bone window and that the superstructure be connected with several impants in the peripheral area.

A change of sinus floor level related to the amount of grafted material after bone added osteotome sinus floor elevation (BAOSFE) technique: A radiographic retrospective study (상악동저 거상술에서 이식재 양에 따른 이식골 높이 변화에 대한 방사선학적 평가)

  • Lee, Ji-Eun;Park, So-Min;Lee, Jong-Bin;Pang, Eun-Kyoung
    • The Journal of the Korean dental association
    • /
    • v.55 no.11
    • /
    • pp.756-765
    • /
    • 2017
  • Purpose: The purpose of this article is to evaluate a change o bone level on the sinus floor by a bone added osteotome sinus floor elevation (BAOSFE) technique, according to the amount of deproteinized bovine bone mineral (DBBM). And Changes in augmented bone height after BAOSFE procedure were also assessed for 6 months after the implant procedure. Materials and Methods: Forty eight single implants were placed in the posterior maxilla using BAOSFE technique. The implantation sites were classified into two groups according to the amount of grafted DBBM, 0.25 group (0.25g) and 0.5 group (0.5 g). Panoramic views or cone-beam computed tomography (CBCT) were taken at the time of implant placement with BAOSFE and after at least 6 months to assess the bone level changes in the elevated sites with DBBM. Results: Alveolar bone level around all implants was stable clinically and radiographically during the follow-up. Mean augmented bone height was $5.21{\pm}0.94mm$ in 0.25 group and $6.92{\pm}1.19mm$ in 0.5 group. Statistically significant difference in augmented bone height was found in the comparison between the 0.25 group and 0.5 group at the time of surgery. There was a positive correlation between the length of the implant protruding into the maxillary sinus and the augmented bone height. After 6 months, mean reduction of augmented bone height was $0.50{\pm}0.34mm$ in 0.25 group and $0.41{\pm}0.30mm$ in 0.5group. There was no specific correlation between the reduction of augmented bone height and amount of grafted DBBM. Conclusion: Within the limit of this study, the amount of grafting materials and the protrusion length of implant into the maxillary sinus affect the amount of the augmented bone height.

  • PDF

Interspinous Implant with Unilateral Laminotomy for Bilateral Decompression of Degenerative Lumbar Spinal Stenosis in Elderly Patients

  • Ryu, Sung-Joo;Kim, In-Soo
    • Journal of Korean Neurosurgical Society
    • /
    • v.47 no.5
    • /
    • pp.338-344
    • /
    • 2010
  • Objective : This study assessed the safety and efficacy of one level unilateral laminotomy bilateral decompression (ULBD) with the placement of a device for intervertebral assisted motion (DIAM) compared with one level ULBD only in elderly patients with degenerative lumbar spinal stenosis (DLSS). Methods : A non randomized prospective analysis was performed on 16 patients who underwent one level ULBD with DIAM (Group A) and 20 patients with one level ULBD only (Group B) between February 2007 and March 2008. Radiographic imaging, visual analog scale (VAS) and MacNab outcome scale were obtained before and after surgery at a mean interval of 21 months (range 17-27 months). Results : The disc height, interpedicular distance, slip distance and segmental lordotic angle were similar between two groups. In the group A, there was no significant difference between the pre- and post-operative imaging in terms of the sagittal balance and disc height. Both groups showed significant improvement in the clinical outcomes. In addition, there was significantly less low-back pain in the group A than in the group B at the last follow up, while the clinical improvement of the leg pain and MacNab outcome scale showed no significant difference in the two groups. There were no major complications or DIAM associated complications. Conclusion : ULBD with DIAM is a safe and efficacious treatment for selective elderly patients with DLSS, particularly for relieving low back pain comparing to ULBD. ULBD with DIAM did not alter the disc height or sagittal alignment at the mean 21 months follow-up interval.

Two-short implant supported single molar restoration in atrophic posterior maxilla : a clinical study (위축된 상악구치부에서 두 개의 짧은 임플란트 지지형 단일치관의 임상연구)

  • Song, Ho-Yong;Heo, Yoon-Hyuk;Park, Chan-Jin;Cho, Lee-Ra
    • The Journal of the Korean dental association
    • /
    • v.53 no.9
    • /
    • pp.628-643
    • /
    • 2015
  • Purpose: The aim of this retrospective study was to compare marginal bone loss and survival rates of double short implants(multiple implant) which had been installed and restored in severely atrophic maxillary molar site without a grafting procedure. Material and Method: The subjects were patients (90 patients, 180 implants) who had been installed double short implants in severely atrophic maxillary single molar site without bone augmentation procedure from 2006 to 2014 in dental clinic in Chuncheon city. Following data were collected from dental records and radiographic panoramic views: patient's age, gender, smoking status, implant site, timing of implant installation, residual ridge height. The correlation between those factors and survival rate and marginal bone loss were analyzed. Statistical analysis was performed using Chi-square test, Student's t- test and ANOVA. Result: Eleven implants in 6 patients failed and the cumulative survival rate was 93.9%. No significant differences were found in relation to the following factors: patient's age, gender, implant site, timing of implant installation (P> .05). There were significant differences in smoking status and residual ridge height(P< .05). The average follow-up time was $45{\pm}14.7months$. The mean marginal bone loss of survived 169 implants was $0.08{\pm}0.59mm$. Conclusion: Despite the short term outcomes, the survival rate of double short implants was comparable to normal length implants. This study demonstrated that placement of double short implants without the use of bone grafting procedure for severely atrophic posterior maxilla is a simple and predictable treatment procedure.

Clinical and Radiological Outcomes of Anterior Cervical Interbody Fusion Using Hydroxyapatite Spacer

  • Kim, Sung-Chul;Kang, Sung-Won;Kim, Se-Hyuk;Cho, Ki-Hong;Kim, Sang-Hyun
    • Journal of Korean Neurosurgical Society
    • /
    • v.46 no.4
    • /
    • pp.300-304
    • /
    • 2009
  • Objective : This is retrospective study of clinical and radiological outcomes of anterior cervical fusion using Bongros-$HA^{TM}$ (BioAlpha, Seongnam, Korea) which is a type of synthetic hydroxyapatite (HA) spacer to evaluate the efficacy in its clinical application and usefulness as a reliable alternative to autograft bone. Methods : Twenty-nine patients were enrolled in this study and 40 segments were involved. All patients were performed anterior cervical interbody fusion using HA spacer and plating system. Indications for surgery were radiculopathy caused by soft-disc herniation or spondylosis in 18 patients, spondylotic myelopathy in 1 patient, and spinal trauma in 10 patients. Cervical spine radiographs were obtained on postoperative 1day, 1week, and then at 1, 2, 6, and 12 months in all patients to evaluate intervertebral disc height, and the degrees of lordosis. Cervical computed tomography was done at postoperative 12 month in all patients to confirm the fusion status. The mean period of clinical follow-up was 17 months. Results : Complete interbody fusion was achieved in 100% of patients. Preoperative kyphotic deformities were corrected in all cases after surgery. Intervertebral disc height was well maintained during follow up period. There were no cases of graft extrusion, graft deterioration and graft fracture. Conclusion : HA spacer is very efficient in achieving cervical fusion, maintaining intervertebral disc height, and restoring lordosis. When combined with the placement of a cervical plate, immediate stability can be achieved and graft related complication can be prevented.

Survival analysis of implants placed in the sinus floor elevated maxilla (상악동저 거상술 후 상악 구치부에 식립된 임플란트의 생존율에 대한 연구)

  • Park, Jong-Yeon;Kim, Ok-Su;Ryoo, Gyeong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.37 no.2
    • /
    • pp.151-164
    • /
    • 2007
  • Objective: The sinus floor elevation procedures have been used to facilitate implant placement in the severely atrophic posterior maxilla. Many variables may have an influence on the outcomes of the sinus floor elevation in combination with implant treatment. The aim of this study was to analyze survival rate of implants placed in the edentulous maxillae of patients in whom sinus floor elevation was undertaken according to variables. Materials and Methods: It consisted of 96 patients(50 male and 46 female), ranging in age from 31 to 70 years(mean 49 years), who underwent sinus floor elevation procedure(94 implants in left side and 106 implants in right side) from 2001 to 2002. A total of 200 implants were placed in the grafted sinus(73 implants in lateral approach and 127 implants in crestal approach). All implants were restored by fixed prosthesis. All patients were healthy. Follow-up periods for implants were between 48 to 60 months. Results: The cumulative survival rate of implants was 91.5%. Gender, age and operation site did not have an influence on the survival rate. There was statistically significant differences for the implants which placed in less than 4 or 5 rom residual bone height, the survival rate was 60%, 81.4% respectively (p<0.05). There was no statistically significant difference of implants survival rate ac- cording to approach technique. The survival rate for 100% autogenous bone grafts was lower with respect to composite grafts containing autogenous bone and 100% substitutes. The survival rate for hydroxyapatite-coated implants was statistically significant lower than other textured group (p<0.05). Conclusion: Residual bone height, surface texture and graft materials have an influence on the survival rate. To use autogenous bone as a part of a composite bone replacement, implant texture which leads to more favorable implant-bone interface were necessary. To determine residual bone height for initial implant stability was important.

Computed tomographic analysis of maxillary sinus anatomy relevant to sinus lift procedures in edentulous ridges in Taiwanese patients

  • Yu, Shun-Jen;Lee, Yi-Hao;Lin, Ching-Ping;Wu, Aaron Yu-Jen
    • Journal of Periodontal and Implant Science
    • /
    • v.49 no.4
    • /
    • pp.237-247
    • /
    • 2019
  • Purpose: To analyze the maxillary sinus anatomy over edentulous ridges in the bilateral posterior maxillary area in Taiwanese patients using cone-beam computed tomography (CBCT). Methods: In total, 101 anatomical sites from 61 patients, including 32 premolar and 69 molar regions, were analyzed using CBCT. Measurements were made of the width and height of edentulous ridges, the thickness of the lateral wall of the maxillary sinus, and the presence of a sinus septum and the posterior superior alveolar artery (PSAA). A statistical analysis of the measurements was performed, and correlations among the measurements were assessed. Results: The average ridge width was $10.26{\pm}3.16mm$, with a significantly greater ridge width in the second molar region than in the premolar region. The mean residual ridge height was $8.55{\pm}4.09mm$, and ridge height showed an opposite trend from ridge width for the premolar and molar regions. A sinus septum was present at 5.9% of the sites, and the PSAA was observed in 24.5%. The average thickness of the lateral wall of the maxillary sinus was $2.08{\pm}0.94mm$, with no significant difference between the tooth position and lateral wall thickness. Conclusions: This study presents the anatomical features of the maxillary sinus, which should be considered in sinus lift procedures for implant placement, in the Taiwanese population. The use of CBCT is recommended to avoid intraoperative complications.

Maxillary sinus augmentation using biphasic calcium phosphate: dimensional stability results after 3-6 years

  • Cha, Jae-Kook;Kim, Chingu;Pae, Hyung-Chul;Lee, Jung-Seok;Jung, Ui-Won;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.49 no.1
    • /
    • pp.47-57
    • /
    • 2019
  • Purpose: This study was designed to observe the resorption pattern of biphasic calcium phosphate (BCP) used for maxillary sinus augmentation over a 3- to 6-year healing period, and to investigate factors affecting the resorption of BCP. Methods: A total of 47 implants placed in 27 sinuses of 22 patients were investigated. All patients had residual bone height less than 5 mm at baseline. The modified Caldwell-Luc approach was used to elevate the maxillary sinus membrane, and the sinus cavity was filled with BCP (70% hydroxyapatite and 30% ${\beta}$-tricalcium phosphate). Implant placement was done simultaneously or in a staged manner. Serial radiographic analysis was performed up to 6 years postoperatively. Results: During the follow-up period, no implant loss was reported. The mean reduced height of the augmented sinus (RHO) was $0.27{\pm}1.08mm$ at 36 months, and $0.89{\pm}1.39mm$ at 72 months postoperatively. Large amounts of graft material (P=0.021) and a long healing period (P=0.035) significantly influenced the amount of RHO. In particular, there was a significant relationship between a healing period longer than 40 months and RHO. Conclusions: BCP can achieve proper dimensional stability with minimal reduction of the graft height in a 3- to 6-year healing period after maxillary sinus augmentation. The healing period and the amount of graft material influenced the resorption of BCP.