• Title/Summary/Keyword: Pitch control

Search Result 799, Processing Time 0.026 seconds

Conductive Properties of Thermoplastic Carbon Fiber Reinforced Plastics Highly Filled with Carbon Fiber Fabrics and Conductive Carbon Fillers (탄소섬유 직물 및 전도성 탄소 필러가 고충진 된 열가소성 탄소섬유강화플라스틱의 전도 특성)

  • Kim, Seong Yun;Noh, Ye Ji;Jang, Ji-un;Choi, Seong Kyu
    • Composites Research
    • /
    • v.34 no.5
    • /
    • pp.290-295
    • /
    • 2021
  • The application of lightweight structural composites to automobiles as a solution in line with global fuel economy regulations to curb global warming is recognized as a megatrend. This study was conducted to provide a technical approach that can respond to the issue of replacing parts that require conductive properties to maximize the application of thermoplastic carbon fiber reinforced plastics (CFRPs), which are advantageous in terms of repair, disposal and recycling. By utilizing the properties of the low-viscosity polymerizable oligomer matrix, it was possible to prepare a thermoplastic CFRP exhibiting excellent impregnation properties while uniformly mixing the conductive filler. Various carbon-based conductive fillers such as carbon black, carbon nanotubes, graphene nanoplatelets, graphite, and pitch-based carbon fibers were filled up to the maximum content, and electrical and thermal conductive properties of the fabricated composites were compared and studied. It was confirmed that the maximum incorporation of filler was the most important factor to control the conductive properties of the composites rather than the type or shape of the conductive carbon filler. Experimental results were observed in which it might be advantageous to apply a one-dimensional conductive carbon filler to improve electrical conductivity, whereas it might be advantageous to apply a two-dimensional conductive carbon filler to improve thermal conductivity. The results of this study can provide potential insight into the optimization of structural design for controlling the conductive properties of thermoplastic CFRPs.

Application of CFD to Design Procedure of Ammonia Injection System in DeNOx Facilities in a Coal-Fired Power Plant (석탄화력 발전소 탈질설비의 암모니아 분사시스템 설계를 위한 CFD 기법 적용에 관한 연구)

  • Kim, Min-Kyu;Kim, Byeong-Seok;Chung, Hee-Taeg
    • Clean Technology
    • /
    • v.27 no.1
    • /
    • pp.61-68
    • /
    • 2021
  • Selective catalytic reduction (SCR) is widely used as a method of removing nitrogen oxide in large-capacity thermal power generation systems. Uniform mixing of the injected ammonia and the inlet flue gas is very important to the performance of the denitrification reduction process in the catalyst bed. In the present study, a computational analysis technique was applied to the ammonia injection system design process of a denitrification facility. The applied model is the denitrification facility of an 800 MW class coal-fired power plant currently in operation. The flow field to be solved ranges from the inlet of the ammonia injection system to the end of the catalyst bed. The flow was analyzed in the two-dimensional domain assuming incompressible. The steady-state turbulent flow was solved with the commercial software named ANSYS-Fluent. The nozzle arrangement gap and injection flow rate in the ammonia injection system were chosen as the design parameters. A total of four (4) cases were simulated and compared. The root mean square of the NH3/NO molar ratio at the inlet of the catalyst layer was chosen as the optimization parameter and the design of the experiment was used as the base of the optimization algorithm. The case where the nozzle pitch and flow rate were adjusted at the same time was the best in terms of flow uniformity.

Change of Voice Parameters After Thyroidectomy Without Apparent Injury to the Recurrent Laryngeal or External Branch of Superior Laryngeal Nerve: A Prospective Cohort Study

  • Lee, Doh Young;Choe, Goun;Park, Hanaro;Han, Sungjun;Park, Sung Joon;Kim, Seong Dong;Kim, Bo Hae;Jin, Young Ju;Lee, Kyu Eun;Park, Young Joo;Kwon, Tack-Kyun
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.33 no.2
    • /
    • pp.89-96
    • /
    • 2022
  • Background and Objectives The quality of life after thyroidectomy, such as voice change, is considered to be as important as control of the disease. In this study, we aimed to evaluate changes in both subjective and objective voice parameters after thyroidectomy resulting in normal morbidity of the vocal cords. Materials and Method In this prospective cohort study, 204 patients who underwent thyroidectomy with or without central neck dissection at a single referral center from Feb 2015 to Aug 2016 were enrolled. All patients underwent prospective voice evaluations including both subjective and objective assessments preoperatively and then at 2 weeks, 3, 6, and 12 months postoperatively. Temporal changes of the voice parameters were analyzed. Results Values of the subjective assessment tool worsened during the early postoperative follow-up period and did not recover to the preoperative values at 12 months postoperatively. The maximal phonation time gradually decreased, whereas most objective parameters, including maximal vocal pitch (MVP), reached preoperative values at 3-6 months postoperatively. The initial decrease in MVP was significantly greater in patients undergoing total thyroidectomy, and their MVP recovery time was faster than that of patients undergoing lobectomy (p=0.001). Patients whose external branch of the superior laryngeal nerve was confirmed intact by electroidentification showed no difference in recovery speed compared with patients without electroindentification (p=0.102), although the initial decrease in MVP was lower with electroidentification. Conclusion Subjective assessment in voice quality and maximal phonation time after thyroidectomy did not show recovery to preoperative values. Aggravation of MVP was associated with surgical extent and electroidentification.

Voice therapy for pitch problems following thyroidectomy without laryngeal nerve injury (신경학적 손상이 없는 갑상선 술 후 음도문제의 음성치료)

  • Ji-sung Kim;Mi-jin Kim
    • Phonetics and Speech Sciences
    • /
    • v.15 no.3
    • /
    • pp.53-58
    • /
    • 2023
  • After thyroidectomy, some patients who show normal vocal cord movement still complain of subjective voice problems, which could lead to a decrease in quality of life related to communication. This study aims to investigate the effectiveness of a newly designed voice therapy applying neck exercise and semi-occluded vocal tract exercise (SOVTE) to improve voice problems after thyroidectomy without neurological injury. For this purpose, voice therapy was randomly assigned to 10 women who received thyroidectomy. Acoustic analysis [fundamental frequency, jitter, shimmer, noise-to-harmonics ratio, min Voice Range Profile (VRP), max VRP, VRP] was performed before and after surgery and immediately after voice therapy to compare voice changes. The study showed a statistically significant increase in max VRP and VRP after voice therapy compared to before surgery. These results suggest that the voice therapy methods in this study effectively improve a major symptom of voice problems after thyroidectomy, specifically the reduction in the high-frequency range. However, this study was limited in the number of s participants and did not control for the type of surgery. Therefore, further research utilizing larger sample sizes and controlled variables is needed to investigate the long-term effects of voice therapy.

Effects of Nitrogen and Phosphorus Fertilization on Soil Nitrogen Mineralization of Pinus rigida and Larix kaempferi Plantations in Yangpyeong area, Gyeonggi Province (질소(窒素)와 인(燐) 시비(施肥)가 경기도(京畿道) 양평지역(楊平地域) 리기다소나무와 낙엽송(落葉松) 조림지(造林地) 토양(土壤) 내(內) 질소무기화(窒素無機化)에 미치는 영향(影響))

  • Lee, Im-Kyun;Son, Yowhan
    • Journal of Korean Society of Forest Science
    • /
    • v.95 no.1
    • /
    • pp.82-90
    • /
    • 2006
  • To examine the effects of nitrogen and phosphorus fertilization on soil nitrogen (N) mineralization, we monitored rates of soil nitrogen mineralization and nitrification in 41-year-old pitch pine (Pinus rigida Mill.) and Japanese larch (Larix kaempferi Gordon) stands growing on similar soil condition in central Korea. For this study, we used the buried-bag incubation method. Fertilizers were applied at three levels [control (C), 200 N kg/ha+25 P kg/ha (LNP), and 400 N kg/ha+50 P kg/ha(HNP)] on 5 June, 1996. Mineral soils (0~20 cm) were incubated 6 times with 45-day-interval from 5 June 1996 to 4 June 1997. Initial soil moisture contents were significantly different among sampling dates and between tree species. Initial soil moisture contents were 32% for C, 28% for LNP, and 26% for HNP at the P. rigida stand, and 31% for C, 31% for LNP, and 33% for HNP at the L. kaempferi stand, respectively. Mean daily N mineralization rates were significantly different among sampling dates and treatments. Annual net N mineralization and nitrification were also significantly different between the two tree species. The annual net N mineralization was 10.6 kg/ha/year for C, 23.3 kg/ha/year for LNP and 6.6 kg/ha/year for HNP at the P. rigida stand, and 2.0 kg/ha/year for C, 12.1 kg/ha/year for LNP and 16.7 kg/ha/year for HNP at the L. kaempferi stand. The annual nitrification was 2.8 kg/ha/year for C, 7.6 kg/ha/year for LNP and 4.3 kg/ha/year for HNP at the P. rigida stand, and 4.3 kg/ha/year for C, 14.8 kg/ha/year for LNP and 6.6 kg/ha/year for HNP at the L. kaempferi stand. The ratios of annual net nitrification to annual net N mineralization were 26% for C, 33% for LNP, 65% for HNP at the P. rigida stand, and 100% for C, 100% for LNP, 40% for HNP at the L. kaempferi stand, respectively. This study indicates that N mineralization in forest may be different by the predominant tree species and fertilization even under similar environments. It is likely that the quality of organic matter might control nitrogen mineralization and nitrification in soils.

Recent Progress in Air-Conditioning and Refrigeration Research: A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2014 (설비공학 분야의 최근 연구 동향: 2014년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.7
    • /
    • pp.380-394
    • /
    • 2015
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2014. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of heat and mass transfer, cooling and heating, and air-conditioning, the flow inside building rooms, and smoke control on fire. Research issues dealing with duct and pipe were reduced, but flows inside building rooms, and smoke controls were newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for thermal contact resistance measurement of metal interface, a fan coil with an oval-type heat exchanger, fouling characteristics of plate heat exchangers, effect of rib pitch in a two wall divergent channel, semi-empirical analysis in vertical mesoscale tubes, an integrated drying machine, microscale surface wrinkles, brazed plate heat exchangers, numerical analysis in printed circuit heat exchanger. In the area of pool boiling and condensing, non-uniform air flow, PCM applied thermal storage wall system, a new wavy cylindrical shape capsule, and HFC32/HFC152a mixtures on enhanced tubes, were actively studied. In the area of industrial heat exchangers, researches on solar water storage tank, effective design on the inserting part of refrigerator door gasket, impact of different boundary conditions in generating g-function, various construction of SCW type ground heat exchanger and a heat pump for closed cooling water heat recovery were performed. (3) In the field of refrigeration, various studies were carried out in the categories of refrigeration cycle, alternative refrigeration and modelling and controls including energy recoveries from industrial boilers and vehicles, improvement of dehumidification systems, novel defrost systems, fault diagnosis and optimum controls for heat pump systems. It is particularly notable that a substantial number of studies were dedicated for the development of air-conditioning and power recovery systems for electric vehicles in this year. (4) In building mechanical system research fields, seventeen studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, and renewable energies, piping in the buildings. Proposed designs, performance performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the evaluation of work noise in tunnel construction and the simulation and development of a light-shelf system. The subjects of building energy were worked on the energy saving of office building applied with window blind and phase change material(PCM), a method of existing building energy simulation using energy audit data, the estimation of thermal consumption unit of apartment building and its case studies, dynamic window performance, a writing method of energy consumption report and energy estimation of apartment building using district heating system. The remained studies were related to the improvement of architectural engineering education system for plant engineering industry, estimating cooling and heating degree days for variable base temperature, a prediction method of underground temperature, the comfort control algorithm of car air conditioner, the smoke control performance evaluation of high-rise building, evaluation of thermal energy systems of bio safety laboratory and a development of measuring device of solar heat gain coefficient of fenestration system.

Selective Separation of $CO_2/CH_4$ by Pore Structure Modification of Activated Carbon Fiber (활성탄소섬유의 기공구조 변형을 이용한 $CO_2/CH_4$의 선택적 분리 기술)

  • Moon, S.H.;Park, S.Y.
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.9
    • /
    • pp.1027-1034
    • /
    • 2007
  • This research was focused on the selective separation of $CO_2$ or $CH_4$ from mixture of these gases, by controlling the size of pore or pore gate. Pitch based activated carbon fibers(ACF) were used as adsorbents. The size of pore gate was controlled by the molecule having similar size to that of pore opening. After the adsorption of adsorbate on pore surface, planar molecules such as benzene and naphthalene covered the pore gate. The slow release of adsorbate from the pores covered by planar molecules makes apertures between planar molecules covering pore gate and this structure can be fixed by rapid pyrolysis. The control of pore gate using benzene as covering molecules could not accomplished due to the simultaneous volatilization of benzene and adsorbate$(CO_2)$ caused by similar temperatures of benzene volatilization and adsorbate desorption. Therefore we replaced benzene with naphthalene looking for the stability at a $CO_2$ desorption temperature. The naphthalene molecule was adsorbed on the ACF up to 15% of ACF weight and showed no desorption until $100^{\circ}C$, indicating that the molecule could be used as a good cover molecule. Naphthalene could cover almost all the pore gate, reducing BET surface area from 753 $m^2/g$ to 0.7 $m^2/g$. A mixed gas$(CO_2:CH_4=50:50)$ was adsorbed on the naphthalene treated OG-7A ACF. The amount of $CO_2$ adsorption increased with total pressure, whileas thai of $CH_4$ was not so much influenced on the pressure, indicating that $CO_2$ made more compounds on the ACF surface along with total pressure increase. The most $CO_2$ and the least $CH_4$ were adsorbed in the condition of 0.4 atm, resulting in the highly pure $CH_4$ left in ACF.

Basic Study to Establish Marine Activity Criteria Based on the Seakeeping Performance of Less Than 10-tons Fishing Vessels(I) (내항성능 기반 10톤 미만 어선의 해양활동 기준 마련 기초 연구(I))

  • Choi, Gwang-Young;Song, Chae-Uk;Park, Young-Soo;Park, Jun-Bum
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.28 no.6
    • /
    • pp.965-972
    • /
    • 2022
  • This is a basic study to establish marine activity criteria based on the seakeeping performance of less than 10-tons fishing vessels. These vessels account for approximately 95% of Korea's currently registered fishing vessels, and accidents and loss of life are also occurring during marine activities such as navigation, and fishing. Accordingly, the Ministry of Oceans and Fisheries has set a regulation of vessel traf ic control to restrict the operation of fishing vessels when the high seas watch takes effect, but it is applied equally without criteria according to the ship ton level and wave height; therefore, many differences may exist in ship fluctuations. Because the fluctuation of the ship owing to the wave height can be a factor in marine accidents by reducing the sense of boarding and performance of equipment, the seakeeping performance must be reviewed during waves to secure safe marine activities such as navigation and fishing. However, the review for the fishing vessel of established marine activity criteria based on the seakeeping performance is insufficient. Accordingly, the seakeeping performance was evaluated for a 10-ton class (G/T 9.77 tons) fishing vessel in Korea, and the level of marine activity according to the significant wave height and ship speed was interpreted by applying the operation and survival of the established seakeeping performance criteria. The analysis results indicated that the roll of the ship exceeded the operation criteria from 0.4m and the survival criteria from 2.2m. The pitch of the ship exceeded the operation criteria from 1.7m and did not exceed the survival criteria until 3.0m. However, the rolling exceeding the survival criteria from 2.2m may not be safe. Therefore, fishing vessels with less than 10-tons can leave before the high seas watch takes effect. However, they did not satisfy the criteria for evaluating the performance of the sea in relation to marine activities. Although this study was limitedly evaluated for 10-ton fishing vessels, it is expected to be of great help in preparing marine activity criteria.

Comparison Radiation Dose of Z-Axis Automatic Tube Current Modulation Technique with Fixed Tube Current Multi-Detector Row CT Scanning of Lower Extremity Venography (하지 정맥조영술 MDCT에서 고정 관전류 기법과 Z-축 자동 관전류 변동 제어에 의한 선량 비교)

  • Yoo, Beong-Gyu;Lee, Jong-Seok;Jang, Keun-Jo;Jeon, Sang-Hwan;Kim, Yong-Soo;Kweon, Dae-Cheol
    • Journal of Radiation Protection and Research
    • /
    • v.32 no.3
    • /
    • pp.123-133
    • /
    • 2007
  • Z-axis automatic tube current modulation technique automatically adjusts tube current based on size of body region scanned. The purpose of the current study was to compare noise, and radiation dose of multi-detector row CT (MDCT) of lower extremity performed with Z-axis modulation technique of automatic tube current modulation with manual selection fixed tube current. Fifty consecutive underwent MDCT venography of lower extremity with use of a MDCT scanner fixed tube current and Z-axis automatic tube current modulation technique (10, 11 and 12 HU noise index, $70{\sim}450\;mA$). Scanning parameters included 120 kVp, 0.5 second gantry rotation time, 1.35:1 beam pitch, and 1 mm reconstructed section thickness. For each subject, images obtained with Z-axis modulation were compared with previous images obtained with fixed tube current (200, 250, 300 mA) and with other parameters identical. Images were compared for noise at five levels: iliac, femoral, popliteal, tibial, and peroneal vein of lower extremity. Tube current and gantry rotation time used for acquisitions at these levels were recorded. All CT examinations of study and control groups were diagnostically acceptable, though objective noise was significantly more with Z-axis automatic tube current modulation. Compared with fixed tube current, 2-axis modulation resulted in reduction of CTDIvol (range, $-6.5%{\sim}-35.6%$) and DLP (range, $-0.2%{\sim}-20.2%$). Compared with manually selected fixed tube current, 2-axis automatic tube current modulation resulted in reduced radiation dose at MDCT of lower extremity venography.