• 제목/요약/키워드: Pitch Measurement

검색결과 266건 처리시간 0.032초

Application of PIV in a Transonic Centrifugal Impeller

  • Hayami Hiroshi;Hojo Masahiro;Aramaki Shinichiro
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2001년도 Proceedings of 2001 Korea-Japan Joint Seminar on Particle Image Velocimetry
    • /
    • pp.1-5
    • /
    • 2001
  • A particle image velocimetry (PIV) was applied to a flow measurement in a transonic centrifugal impeller. A phase locked measurement technique every $20\%$ blade pitch enabled a reconstruction of a velocity field over one blade pitch. The measured velocity field at the inducer of impeller clearly showed a shock wave generated on the suction surface of a blade.

  • PDF

Measurements of Two-dimensional Gratings Using a Metrological Atomic Force Microscope with Uncertainty Evaluation

  • Kim, Jong-Ahn;Kim, Jae-Wan;Kang, Chu-Shik;Eom, Tae-Bong
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제9권2호
    • /
    • pp.18-22
    • /
    • 2008
  • The pitch and orthogonality of two-dimensional (2-D) gratings were measured using a metrological atomic force microscope (MAFM), and the measurement uncertainty was analyzed. Gratings are typical standard devices for the calibration of precision microscopes, Since the magnification and orthogonality in two perpendicular axes of microscopes can be calibrated simultaneously using 2-D gratings, it is important to certify the pitch and orthogonality of such gratings accurately for nanometrology. In the measurement of 2-D gratings, the MAFM can be used effectively for its nanometric resolution and uncertainty, but a new measurement scheme is required to overcome limitations such as thermal drift and slow scan speed. Two types of 2-D gratings with nominal pitches of 300 and 1000 nm were measured using line scans to determine the pitch measurement in each direction. The expanded uncertainties (k = 2) of the measured pitch values were less than 0.2 and 0.4 nm for each specimen, and the measured orthogonality values were less than $0.09^{\circ}$ and $0.05^{\circ}$, respectively. The experimental results measured using the MAFM and optical diffractometer agreed closely within the expanded uncertainty of the MAFM. We also propose an additional scheme for measuring 2-D gratings to increase the accuracy of calculated peak positions, which will be the subject of future study.

발화방식에 따른 미국인 남성 영어모음의 피치와 포먼트 궤적 (Pitch and Formant Trajectories of English Vowels by American Males with Different Speaking Styles)

  • 양병곤
    • 말소리와 음성과학
    • /
    • 제4권1호
    • /
    • pp.21-28
    • /
    • 2012
  • Many previous studies reported acoustic parameters of English vowels produced by a clear speaking style. In everyday usage, we actually produce speech sounds with various speaking styles. Different styles may yield different acoustic measurements. This study attempts to examine pitch and formant trajectories of eleven English vowels produced by nine American males in order to understand acoustic variations depending on clear and conversational speaking styles. The author used Praat to obtain trajectories systematically at seven equidistant time points over the vowel segment while checking measurement validity. Results showed that pitch trajectories indicated distinct patterns depending on four speaking styles. Generally, higher pitch values were observed in the higher vowels and the pitch was higher in the clear speaking styles than that in the conversational styles. The same trend was observed in the three formant trajectories of front vowels and the first formant trajectories of back vowels. The second and third trajectories of back vowels revealed an opposite or inconsistent trend, which might be attributable to the coarticulation of the following consonant or lip rounding gestures. The author made a tentative conclusion that people tend to produce vowels to enhance pitch and formant differences to transmit their information clearly. Further perceptual studies on synthesized vowels with varying pitch and formant values are desirable to address the conclusion.

현미경의 길이표준 소급성 확립을 위한 배율 교정 시편 인증 (Certification of magnification standards for the establishment of meter-traceability in microscopy)

  • 김종안;김재완;박병천;엄태봉;강주식
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.645-648
    • /
    • 2005
  • Microscopy has enabled the development of many advanced technologies, and higher level microscopic techniques are required according to the increase of research in nano-technology and bio-technology fields. Therefore, in many applications, we need to measure the dimension of micro-scale parts accurately, not just to observe their shapes. To establish the meter-traceability in microscopy, gratings have been widely used as a magnification standard. KRISS provides the certification service of magnification standards using an optical diffractometer and a metrological AFM (MAFM). They are based on different measurement principles, and so can give complementary information for each other. In this paper, we describe the configuration of each system and measurement procedures to certificate grating pitch values of magnification standards. Several measurement results are presented, and the discussion about them are also given. Using the optical diffractometer, we can calibrate a grating specimen with uncertainty of less than 50 pm. The MAFM can measure a grating specimen of down to 100 nm pitch value, and the calibrated values usually have uncertainty less than 500 pm.

  • PDF

XY 스캐너의 아베 오차 최소화를 위한 최적 설계 및 나노 정밀도의 원자 현미경 피치 측정 불확도 평가 (Optimal design of a flexure hinge-based XY AFM scanner for minimizing Abbe errors and the evaluation of pitch measuring uncertainty of a nano-accuracy AFM system)

  • 김동민;이동연;권대갑
    • 한국정밀공학회지
    • /
    • 제23권6호
    • /
    • pp.96-103
    • /
    • 2006
  • To establish of standard technique of nano-length measurement in 2D plane, new AFM system has been designed. In the long range (about several tens of ${\mu}m$), measurement uncertainty is dominantly affected by the Abbe error of XY scanning stage. No linear stage is perfectly straight; in other words, every scanning stage is subject to tilting, pitch and yaw motion. In this paper, an AFM system with minimum offset of XY sensing is designed. And XY scanning stage is designed to minimize rotation angle because Abbe errors occur through the multiply of offset and rotation angle. To minimize the rotation angle optimal design has performed by maximizing the stiffness ratio of motion direction to the parasitic motion direction of each stage. This paper describes the design scheme of full AFM system, especially about XY stage. Full range of fabricated XY scanner is $100{\mu}m\times100{\mu}m$. And tilting, pitch and yaw motion are measured by autocollimator to evaluate the performance of XY stage. As a result, XY scanner can have good performance. Using this AFM system, 3um pitch specimen was measured. The uncertainty of total system has been evaluated. X and Y direction performance is different. X-direction measuring performance is better. So to evaluate only ID pitch length, X-direction scanning is preferable. Its expanded uncertainty(k=2) is $\sqrt{(3.96)^2+(4.10\times10^{-5}{\times}p)^2}$ measured length in nm.

음성신호의 Jitter 성분의 장시간 변화에 관한 통계적 분석 (Statistical analysis on long-term change of jitter component on continuous speech signal)

  • 조철우
    • 말소리와 음성과학
    • /
    • 제12권4호
    • /
    • pp.73-80
    • /
    • 2020
  • 본 연구에서는 연속음성에서의 장시간 jitter 성분 측정 방법에 대해 고찰하였다. 기존의 jitter측정방법으로는 지속 발성한 모음을 대상으로 변동성을 측정하는 방법을 주로 사용하여왔다. 문장음성 등 연속음성의 경우는 문장에 따른 운율정보의 영향으로 기존의 측정법으로는 왜곡이 발생하게 된다. 이에 연속 발성에 대해 운율정보의 피치 변동을 상쇄시키는 방법을 제안하고자 한다. 피치 변동을 제거하는 방법으로는 분석구간내에서의 피치 변동을 다항식 보간법에 의해 변동 경향을 대표하는 곡선을 구하고 그 곡선을 기준으로 변이를 제거하였다. 이후 변이가 제거된 피치의 궤적으로부터 jitter를 측정하는 방법을 적용하여 피치 주파수의 변동성을 측정하고 기존의 지속모음에 의한 측정 방법과 비교하였다. 제안한 방법의 효용성 측정을 위해 Kay Pentax MEEI DB의 음성 표본을 사용하였다. 통계분석 결과 제안된 방법에 의해 연속음성으로부터 측정한 jitter 값은 동일 화자의 지속모음으로부터 측정한 파라미터 값과 유사한 변동성을 보여 주었다.

ROLL AND PITCH ESTIMATION VIA AN ACCELEROMETER ARRAY AND SENSOR NETWORKS

  • Baek, W.;Song, B.;Kim, Y.;Hong, S.K.
    • International Journal of Automotive Technology
    • /
    • 제8권6호
    • /
    • pp.753-760
    • /
    • 2007
  • In this paper, a roll and pitch estimation algorithm using a set of accelerometers and wireless sensor networks(S/N) is presented for use in a passenger vehicle. While an inertial measurement unit(IMU) is generally used for roll/pitch estimation, performance may be degraded in the presence of longitudinal acceleration and yaw motion. To compensate for this performance degradation, a new roll and pitch estimation algorithm is proposed that uses an accelerometer array, global positioning system(GPS) and in-vehicle networks to get information from yaw rate and roll rate sensors. Angular acceleration and roll and pitch approximation are first calculated based on vehicle kinematics. A discrete Kalman filter is then applied to estimate both roll and pitch more precisely by reducing noise from the running engine and from road disturbance. Finally, the feasibility of the proposed algorithm is shown by comparing its performance experimentally with that of an IMU in the framework of an indoor test platform as well as a test vehicle.

한국인을 위한 음도진단용 표준문장개발연구: 예비측정 및 분석결과 (Developing Sample Sentences for Voice Assessment of Koreans: A Preliminary Study)

  • 김수진;문승재;신지영
    • 대한음성학회:학술대회논문집
    • /
    • 대한음성학회 2003년도 5월 학술대회지
    • /
    • pp.109-112
    • /
    • 2003
  • This paper aims at developing sample paragraphs for voice pitch assessment which is specifically designed for Koreans. Recently the demand for such a battery of sample sentences has been steadily increased among Korean speech therapists. In this paper, different sample paragraphs (two conventionally used paragraphs and three newly developed ones which consist mainly of sonorant sounds and different types of sentences), different softwares (Dr. Speech, Wavesurfer, Praat) and different techniques (automatic measurement and detailed measurement in which the researcher controls many aspects which might influence the measurement of pitch) will be compared for measuring fundamental frequency.

  • PDF

항공기 피치 조종력 비행시험 (Flight Test of Pitch Control Force for an Airplane)

  • 이정훈
    • 항공우주시스템공학회지
    • /
    • 제8권3호
    • /
    • pp.20-26
    • /
    • 2014
  • This paper presents the procedures and the results of the pitch control force via flight test for a light airplane in order to make out the stability of the aircraft and the compliance with concerned regulation. The flight test procedures were determined in order to obtain the aircraft type certification. The instrumentation equipments including airspeed indicator, accelerometer, and pitch control force measurement tools are used to perform the flight test. For the flight test, the airspeed and the pitch control force with related normal acceleration are measured sustaining turn flight with bank angle derived from trim speed. The flight test results showed that the handling qualities of the airplane are complied with the KAS-23, the regulation of the Korean government for the light airplane type certification.

원자현미경용 XY 스캐너의 아베 오차 최소화를 위한 최적 설계 및 원자 현미경의 측정 불확도 평가 (Optimal design of a flexure hinge-based XY AFM scanner for minimizing Abbe errors and the evaluation of measuring uncertainty of AFM system)

  • 김동민;이동연;권대갑
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.1438-1441
    • /
    • 2005
  • To establish of standard technique of nano-length measurement in 2D plane, new AFM system has been designed. In this system, measurement uncertainty is dominantly affected by the Abbe error of XY scanning stage. No linear stage is perfectly straight; in other words, every scanning stage is subject to tilting, pitch and yaw motion. In this paper, an AFM system with minimum offset of XY sensing is designed. And XY scanning stage is designed to minimize rotation angle because Abbe errors occur through the multiply of offset and rotation angle. To minimize the rotation angle optimal design has performed by maximizing the stiffness ratio of motion direction to the parasitic motion direction of each stage. This paper describes the design scheme of full AFM system, especially about XY stage. Full range of fabricated XY scanner is $100um\times{100um}$. And tilting, pitch and yaw motion are measured by autocollimator to evaluate the performance of XY stage. Using this AFM system, 3um pitch specimen was measured. As a result, the uncertainty of total system has been evaluated.

  • PDF