• Title/Summary/Keyword: Pit and fissure sealants

Search Result 38, Processing Time 0.027 seconds

Antibacterial Properties of Pit and Fissure Sealant Containing S-PRG filler on Streptococcus mutans (S-PRG filler를 포함한 치면열구전색제의 Streptococcus mutans에 대한 항미생물 특성에 관한 연구)

  • An, Jinseon;Park, Howon;Seo, Hyunwoo;Lee, Siyoung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.42 no.4
    • /
    • pp.302-311
    • /
    • 2015
  • The purpose of this study was to evaluate the antibacterial properties of a sealant containing S-PRG filler compared to those of two contemporary commercial sealants to determine the inhibition of bacterial growth in broth culture and biofilm formation using the CDC Biofilm Reactor. The BeautiSealant containing S-PRG filler, the fluoride releasing Clinpro$^{TM}$ sealant, which are known to have higher antibacterial effects, and the non-fluoride releasing Concise$^{TM}$ sealant were selected for this study. A Streptococcus mutans culture in BHI broth without sealant served as a negative control in the planktonic growth inhibition test. As a result, bacterial growth was inhibited in all three sealant groups compared to that in the control. The Clinpro$^{TM}$ sealant showed a significantly reduced number of CFUs compared to those of the BeautiSealant and Concise$^{TM}$ sealants. However, no significant difference was detected between the BeautiSealant and Concise$^{TM}$ sealants. The Clinpro$^{TM}$ sealant significantly decreased biofilm formation compared to that by the BeautiSealant and Concise$^{TM}$ sealants. No significant difference was observed between the BeautiSealant and Concise$^{TM}$ sealants. In conclusion, the sealant containing S-PRG filler had a less potent anti-bacterial property and increased biofilm formation capacity compared to those of the fluoride releasing Clinpro$^{TM}$ sealant.

A STUDY ON THE MICROLEAKAGE OF PIT AND FISSURE SEALANTS WITH DIFFERENT FILLING AMOUNT (치면열구전색재의 충전량에 따른 미세누출의 비교연구)

  • Park, Soo-Jin;Jung, Tae-Sung;Kim, Shin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.2
    • /
    • pp.238-244
    • /
    • 2003
  • With the purpose of evaluating the effect of ailing amount of pit and assure sealants on the microleakage, 6 groups of specimens with different filling amount, filling materials and surface pretreatment were investigated. Sixty permanent third molars were divided into three groups. The occlusal surface of each tooth was divided into two parts; the filing width of one part was below 1mm (group1, 3, 5), and in the other part more than 2mm (group 2, 4, 6) Group 1 and 2: Helioseal F was applied directly to etched enamel; Group 3 and 4: Helioseal F was applied to etched and scotchbond Multi-purpose plus pre-treated enamel; Group 5 and 6: Tetric Flow was applied. After 500 times thermocycling and dye infiltration, we evaulated the microleakage. The results were as follows; 1. The mean microleakage score at each width were increased in the following order;group 5<3<1, and group 6<4<2. 2. In comparing the groups with same material and surface pretreatment but with different filling width (group 1 versus 2, 3 versus 4, 5 versus 6), the microleakage scores were significantly different. 3 The microleage was affected by filling amount of pit and assure sealants than Oiling materials and dentin bonding agent pretreatment.

  • PDF

BUBBLE BEHAVIOR OF PIT AND FISSURE SEALANT (치면열구전색제의 도포 시 전색제에 따른 기포 발생 양태)

  • Kim, Hyun-Jin;Lee, Nan-Young;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.34 no.1
    • /
    • pp.99-105
    • /
    • 2007
  • In clinical practice, air bubbles trapped in the pit and fissure may increase early loss of sealing materials for fracture, wear and microleakage. The purpose of this investigation was to examine the bubble behavior of pit and fissure sealant. The 140 replicas made of epoxy resin were used to this experiment. Following conditioning, light-polymerized sealants were applied and then exposed to the light source. After stereoscopic examination of standarized specimen by grinding, bubble behavior was analysed. The results obtained were as follows; 1. Ultraseal $XT^{(R)}$ plus grops irrespective of using time were higher than groups of $Helioseal^{(R)}$ with clinpro tip and metal tip in the frequency of bubble(p<0.05), 2. Ultraseal $XT^{(R)}$ plus old group was more than $Clinpro^{(R)}$, Teethmate $F-l^{(R)}$ and $Helioseal^{(R)}$ with brush tip in the number of bubble under 200 magnified cross section(p<0.05). 3. The widest mean area of bubble was shown in the Teethmate $F-1^{(R)}$. 4. No statistically significant difference of the frequency and the site of bubble between $Clinpro^{(R)}$ and $Helioseal^{(R)}$ groups(p>0.05).

  • PDF

INFLUENCE OF THE ENAMEL TREATMENT WITH ER:YAG LASER ON THE MICROLEAKAGE OF PIT AND FISSURE SEALANT (Er:YAG 레이저를 이용한 법랑질 표면처리가 치면열구전색제의 미세누출에 미치는 영향)

  • Lee, Ji-Hyun;Kim, Jae-Moon;Kim, Shin;Jeong, Tae-Sung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.2
    • /
    • pp.192-200
    • /
    • 2006
  • The aim of this study was to assess the microleakage underneath a pit and fissure sealant bonded to occlusal surfaces treated by Er:YAG laser To determine the most effective energy density of laser, fourteen specimens were irradiated from 50mJ to 300mJ at 3Hz. After irradiation, the lased specimens were observed under the scanning electron microscope. Thirty six non-carious extracted premolars were randomly assigned to four groups of nine teeth: group 1, no treatment on the occlusal surface; group 2, acid etching for 15 seconds; group 3, Er:YAG laser irradiation; group 4, acid etching followed by Er:YAG laser irradiation. The pits and fissures were sealed with unfilled sealant(Helioseal F) and the specimen teeth were thermo-cycled, immersed in 2% Rhodamine B solution, longitudinally sectioned and analyzed for microleakage with fluorescent microscope. The results were as follows: 1. Er:YAG lased surfaces with 50mJ, 3Hz showed a similar pattern of irregularity with acid etched enamel surfaces 2. The mean microleakage score increased in the order of group 2, 4, 3 and 1. There was no significant difference among group 1, 3 and 4(p>0.05), however group 2 showed significantly less microleakage compared with group 1 and 3. Conclusively, the laser irradiation seemed not enough to replace the acid etching for proper retention of pit and fissure sealants.

  • PDF

A STUDY OF MICROLEAKAGE AND PENETRATION ABILITY OF A PIT AND FISSURE SEALANT APPLIED ON CARIOUS FISSURES (우식성 열구에 적용한 치면열구전색제의 미세누출과 침투도에 관한 연구)

  • Im, El;Lee, Sang-Ho;Lee, Nan-Young
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.37 no.3
    • /
    • pp.345-351
    • /
    • 2010
  • The purpose of this study is to compare microleakage and penetration depths of sealants applied in carious and sound fissures. Extracted premolars(n=80) were divided into 4 groups according to caries status. 1; sound, 2; stained, 3; initial caries, 4; enamel caries. Sealants were applied to the occlusal groove as per manufacturers' instructions, and specimens were thermocycled, stained, sectioned, and examined for microleakage and penetration ability. The results of the present study are as follow: 1. It showed significantly higher microleakage scores in group I than group Two, Three, Four(p<0.05), but no significant difference was found between group Two, Three, and IV(p>0.05). 2. It showed significantly higher penetration scores in group Four (p<0.05), followed by group One, Two, Three, but no significant difference was found between group One, Two, and Three(p>0.05). Based on the results of present study, when the borders of the fissure sealant are on carious enamel, a significantly higher microleakage must be expected. It is considered that depth of enamel caries in the fissure should be taken into account when applying a fissure sealant.

EFFECT OF TIME ELAPSED FROM APPLICATION TO CURING ON THE PENETRATION OF SEALANT (치면열구전색제 도포 후 광중합 할 때까지의 경과시간이 전색제 침투에 미치는 영향)

  • Choi, Sun-Ah;Lee, Chang-Seop;Lee, Sang-Ho;Lee, Nan-Young
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.32 no.3
    • /
    • pp.491-498
    • /
    • 2005
  • Occlusal fissures and pits are ideal places for the development of caries. Pit and fissure sealants are now considered as a very effective means to prevent dental caries. The purpose of this investigation was to examine the effect on the sealant penetration of the elapse of time from the application of sealant until exposure to visible light, and to examine the effect of the filler content and tooth position on the sealant penetration. 192 extracted human premolars were used to this experiment. Following enamel conditioning, a light-polymerized sealant was applied and 4 different periods of time(3, 5, 10, 20 seconds) were allowed until exposure to the light source. The results obtained were as follows; 1. According to time, in both unfilled sealant and filled sealant penetration increases deeply through mindfulness. 2. Sealant that apply to mandiblar premolar penetrated deeply through than to maxillay teeth. 3. Penetration difference according to filler content, unfilled sealant penetrated deeply through than filled sealant. The result from this study indicated that unfilled sealant penetrated most deeply in mandible when at least 20s time elapsed.

  • PDF

Shear Bond Strength and Microleakage of a New Self-etch Sealant Containing S-PRG filler (S-PRG 필러를 포함하는 치면열구전색제의 전단결합강도 및 미세누출)

  • An, Jinseon;Lee, Juhyun;Seo, Hyunwoo;Park, Howon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.43 no.4
    • /
    • pp.347-353
    • /
    • 2016
  • The purpose of this study was to evaluate shear bond strength and microleakage of a new self-etch fissure sealant containing S-PRG filler (BeautiSealant). Fourty-five premolars were randomly divided into three groups: SEPBS group (Self-etching primer + BeautiSealant), AEBS group (Phosphoric acid etching + BeautiSealant), AECP group (Phosphoric acid etching + $Clinpro^{TM}$ sealant). For the shear bond strength test, microcylinders of fissure sealant were bonded to prepared buccal surfaces of teeth and shear bond strengths were measured by a universal testing machine. For the microleakage test, sealants were applicated on each occlusal fissure of teeth. All teeth surface were coated with finger nail varnish, with the exception of a 1.0 mm window around the sealant margins. The teeth were immersed in 2% methylene blue solution for 24 hours and then rinsed in water. The teeth were then embedded in resin and cut buccolingually along the tooth axis and observed with a stereomicroscope to determine the degree of microleakage. SEPBS group demonstrated lower bond strength in comparison with that of AEBS and AECP groups (p < 0.05). However, no significant differences were observed between AEBS and AECP groups. There was no statistically significant difference in degree of microleakage among three groups.

Evaluation of High-power Light Emitting Diode Curing Light on Sealant Polymerization (고출력 발광 다이오드 광중합기의 치면열구전색제 중합능 평가)

  • Park, Youngjun;Lee, Jewoo;Ra, Jiyoung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.46 no.1
    • /
    • pp.57-63
    • /
    • 2019
  • This study aimed to determine whether the curing times of Xtra Power and High Power modes of high-power light emitting diode (LED) curing light are sufficient for polymerization of resin sealants. The specimens were prepared and their microhardness values were measured and compared with those of specimens polymerized under conventional LED curing light. The filled sealant polymerized for 8 seconds in the High Power mode and for 3 seconds in the Xtra Power mode showed significantly lower microhardness than the control specimen (p = 0.000). The unfilled sealant polymerized for 8, 12 seconds in the High Power mode and for 6 seconds in the Xtra Power mode showed significantly lower microhardness than the control specimen (p = 0.000). The results of this study suggest that the short curing time with the Xtra Power and High Power modes of highpower LED curing light are not sufficient for adequate polymerization of sealants under specific conditions, taking into account the curing times and the type of sealant.

A STUDY ON MICROLEAKAGE OF PIT AND FISSURE SEALANT AFTER ENAMEL SURFACE TREATMENT (법랑질 표면처리방법에 따른 치면열구전색재의 미세누출에 관한 비교연구)

  • Hyun, Hong-Keun;Kim, Jung-Wook;Lee, Sang-Hoon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.3
    • /
    • pp.512-521
    • /
    • 2001
  • Recently. the reintroduction of air-abrasion technology in dentistry has added a new potential method of pretreating teeth prior to placing sealants. The purpose of this in vitro study was to investigate microleakages of several pit and fissure sealants following various surface pre-treatment methods to the enamel, because there was a question concerning the validity of claim that this method was better than the conventional acid etching. Permanent molars were divided randomly into nine groups and treated accordingly: acid etching(group 1, 4, 7), air-abrasion(group 2, 5, 8), acid etching after air-abrasion(group 3, 6, 9). Then the authors placed and cured the three kinds of sealants(group $1\sim3$: Teethmate-F, group $4\sim6$: Ultraseal XT plus, group $7\sim9$: Denseal) according to the manufacturer's order. They were observed to determine the degree of microleakage. And these specimens were separated from the corresponding enamels and examined by Scanning Electron Microscope. The following results were obtained: 1. In comparing microleakage among tooth surface treatment methods, air-abrasion group(group 2, 5, 8) showed the greatest microleakage, while combination(air-abrasion + acid etching) group showed the least (p<0.05). However, no significant differences were found between group 7 and 9. 2. The mean microleakages were ranked as follows(p<0.05): In acid etching groups, group 7> group 4> group 1. In air-abrasive groups, group 8>groups 5> group 2. In combination groups, group 9>group 3> group 6. However, no significant differences were found between group 4 and 7 between group 2 and 5 and between group 3 and 6. 3. SEM showed that comparably longer resin tags were distributed regularly in acid etching groups and that shorter ones irregularly in air-abrasion groups. It also showed that these two kinds of tags were distributed simultaneously in combination groups.

  • PDF

Evaluation of Microtensile Bond Strength of Sealant Depending on the Duration of Etching and the Use of Bonding Agent (치면열구전색제의 산부식 시간과 접착제 유무에 따른 미세인장결합강도 평가)

  • Shim, Seoyoun;Song, Hojun;Yang, Sunmi;Kim, Jaehwan;Kim, Seonmi;Choi, Namki
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.45 no.3
    • /
    • pp.299-306
    • /
    • 2018
  • The aim of this study was to evaluate the effect of etching time and bonding agents on bond strength of sealant applied to the occlusal surface of primary molars. Forty non-carious exfoliated human primary molars were included in the study. The teeth were randomly divided into 4 groups for measurement. For group I, no acid etching treatment was used. For group II, III, and IV, acid etching gels were applied on the occlusal surface for 15, 30, and 60 seconds, respectively. Each group was divided into 2 subgroups; one group was treated with bonding agents on the enamel while the other was not. Microtensile bond strength was evaluated using a universal testing machine. There were no statistically significant differences in bond strength with varying duration of etching among groups. The results revealed that the use of bonding agents prior to application of fissure sealant increased the bond strength(p < 0.05). It could be concluded that etching time greater than 15 seconds does not significantly enhance the bond strength, but the use of bonding agents as an intermediate layer between the primary molar and fissure sealant would be beneficial in increasing the bond strength.