• 제목/요약/키워드: Piping vibration

검색결과 171건 처리시간 0.022초

원자력 발전소 배관계 글로브 밸브의 고주파 진동 원인 분석 및 해결 사례 (A Case Study of Root Cause Analyses and Remedies for High frequency Vibration of Globe Valve in Nuclear Power Plant Piping System)

  • 최병화;박수일;전창빈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.394-399
    • /
    • 2005
  • A case history is presented pertaining to high frequency piping vibration and noise caused by globe valve in the spent fuel pool cooling system of nuclear power plant. Frequency analyses were performed on the system to diagnose the problem and develop a solution to reduce the piping vibration and noise. The source of the high frequency and noise energy was traced to the globe valve located immediately downstream of the centrifugal pump by performing valve throttling test. Measurements of vibration and noise are presented to show that the high frequency vibration and noise amplitude was dependent upon the valve disc position and flow rate. Strouhal vortex shedding frequencies were generated at the exit of the globe valve which exited structural resonance of valve disc and amplified the high frequency vibration and noise. The problem was identified as an interaction between the flow inside globe valve and the valve disc structure. Attempts to reduce the vibration and noise amplitudes of the piping system were successfully achieved by the modification of guide-disc diameter and disc-edge figure The valve disc was replaced by an alternative to eliminate the source of the harmful high frequency vibration and noise.

  • PDF

초임계 보일러 재열기 급수 공급배관의 과도 음향진동 진단 및 회피설계 (Mechanism Diagnosis and Avoidance Design on Transient Acoustic Vibration of Reheater Water Supply Piping in Supercritical Boiler)

  • 김연환;배용채;김재원;이두영;허해용
    • 한국소음진동공학회논문집
    • /
    • 제23권5호
    • /
    • pp.385-393
    • /
    • 2013
  • In this paper, the mechanism identification and the avoidance measures on the phenomena of transient acoustic vibration amplified at the water-supply piping system to regulate the steam temperature of the boiler reheater in 500MW class supercritical power plant are presented. The pressure pulsation waves induced by the impeller passing of two feed-water pumps with five blades are coincident with the local acoustic modes of boiler reheater water-supply piping system. There are the phenomena amplified at the peaks of 5X, 10X, 15X and 20X in spectrums of piping vibration, sound pressure, and the feed-water's pressure pulsation waves. The shut-off device is installed in the piping system for the interception of pressure pulsation waves transmitted from two feed-water pumps and the modified design change of the piping layout is applied for the acoustic resonance avoidance. The acoustic natural frequencies are separated from the harmonics of pressure pulsation waves induced by the pump impellers passing through the design change of the span length. The acoustic vibration is gone by resonance avoidance measures. As a result, more than 20 dBA reduction is achieved from 100 dBA to 80 dBA.

습분 분리 재열기 배수배관의 과도진동과 배관 건전성 (Excess Vibration Phenomena and Soundness of Drain Piping in Moisture Separator Reheat Exchanger)

  • 김연환;김희수;배용채;이현;이영신
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 춘계학술대회논문집
    • /
    • pp.393-398
    • /
    • 2001
  • Pulsations, vibration and stress are the basic dynamic phenomena in power plant piping systems which directly affect system reliability. These phenomena are both acoustical and mechanical in nature and are closely interrelated. It was noticed that thermodynamic parameters were changed after replacing with new type tube bundles of reheat exchanger. It was reported later that the drain piping connecting the new bundle header with the associated drain tank is regularly pulsating at about every 3 second with 13.4㎐ and 7.5mm, p-p in amplitude. This amplitude is about 6 times higher than reference level of sound piping. The results of finite element analysis of the pipeline showed that its dominant natural frequency is 13.4㎐. The soundness is predicted whether the bending dynamic stress evaluated excesses the maximum allowable high cycle fatigue stress or not by the measured amplitude of vibration.

  • PDF

급수 배관계의 음향진동 현상 고찰 및 대책 (Mechanism Investigation and Measures on Acoustic Vibration Phenomena of Water Supply Piping)

  • 김연환;배용채;이두영
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2012년도 추계학술대회 논문집
    • /
    • pp.470-475
    • /
    • 2012
  • The downstream piping system of the water supply system in a supercritical power plant is affected by the fluctuation pressure waves induced by accessing to the acoustic modes of the piping systems with the rotation and impeller passing pulsations of the feed water pump. There are the phenomena amplified at the same time in the range of 415 ~ 455Hz, 830 ~ 910Hz, 1245 ~ 1365Hz and 1660 ~ 1820Hz on the spectrums of the vibration, the sound pressure, and the pressure fluctuation waves.

  • PDF

국내 안전등급 배관에 대한 손상사례 분석 (Piping Failure Analysis In Domestic Nuclear Safety Piping System)

  • 최선영;최영환
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.617-621
    • /
    • 2003
  • The purpose of this paper is to analyze piping failure trend of safety pipings In domestic nuclear power plants. First, database for the piping failure was constructed with 105 data fields. The database includes plant population data, event data, and service history data. 7 kinds of piping failures in domestic NPPs were investigated. Among the 7 cases, detailed root causes were investigated for 3 cases. The first one is pipe wall thinning in main feedwater pipings of Westinghouse 3 loop type plants. The root cause of the wall thinning was flow accelerated corrosion near welding area. The next one is leak event in chemical and volume control system(CVCS) due to vibration. Some cracks occurred in socket welding area. The events showed that the integrity or socket weld is very vulnerable to vibration. The last one is also a leak event in primary sampling line in Korean standard reactor due to thermal fatigue. Although the structural integrity was not maintained by the events, there was no effect on nuclear safety in the above 3 piping failure eases.

  • PDF

원자로 주 배관계의 진동 건전성 시험 (Verification Test for Primary Reactor Piping in Nuclear Power Plant)

  • 김연환;김희수;구재량;배용채;이현
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문집
    • /
    • pp.74-79
    • /
    • 2002
  • The piping verification tests were performed in order to verify the structural integrity during initial operation of the reactor coolant systems and the primary heat transportation systems of nuclear power plants by KEPRI in Korea. The tests were conducted at full operating temperature and pressure. The objective is to evaluate the possibility of excessive load generating on piping, piping supports, and reactor structures etc. in the steady normal operation and expected pump transient conditions. As a result, the measured vibrations have been shown acceptable level according to ASME/ANSI OMa-Standard, Part 3.

  • PDF

원자로 주 배관계의 진동 건전성 시험 (Verification Test for Primary Reactor Piping in Nuclear Power Plant)

  • Kim, Yeon-Whan;Kim, Hee-Su;Koo, Jae-Raeyang;Bea, Yong-Chae;Lee, Hyun
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문초록집
    • /
    • pp.315.1-315
    • /
    • 2002
  • The piping verification tests were performed in order to verify the structural integrity during initial operation of the reactor coolant systems and the primary heat transportation systems of nuclear power plants by KEPRI in Korea. The tests were conducted at full operating temperature and pressure. The objective is to evaluate the possibility of excessive load generating on piping, piping supports, and reactor structures etc. in the steady normal operation and expected pump transient conditions. (omitted)

  • PDF

전달행렬법을 이용한 3차원 파이프 계의 진동해석 (Vibration Analysis of Three-Dimensional Piping System by Transfer Matrix Method)

  • 이동명
    • 한국생산제조학회지
    • /
    • 제7권6호
    • /
    • pp.110-116
    • /
    • 1998
  • For the vibration analysis of 3-dimensional piping system containing fluid flow, a transfer matrix method is presented. The fluid velocity and pressure were considered, that coupled to longitudinal and flexural vibrations. Transfer matrices and point matrices were derived from direct solutions of the differential equations of motion of pipe conveying fluids, and the variations of natural frequency with flow velocity for 3-dimensional piping system were investigated.

  • PDF

급수배관시스템의 수충격 진동제어를 위한 실험적 연구 (An Experimental Study on Vibration Control of Water Hammering in Water Pipe System)

  • 이장현;이효행;권병하;오진우
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.453-458
    • /
    • 2008
  • Pump of high lift use to development of a technological level according as a building grow big. Water-Hammer to increase by valve of fast to closing agreeably to pipe laying to accept electronic valve, because by a damage of piping-system and the devil knows injury of vibration. Water-Hammer take a low effect to various method for solve. A New type manufacture develop and testing of pipe line to same to axis use to accumulator for water-Hammer to low effect and liner control of pressure. Impact-pressure of absorption ability and confirmation to decrease of vibration level through to preexistence manufactures and comparative test. Water-hammer and pipe vibration make low of piping system.

  • PDF

대형펌프 토출배관계에서 발생하는 진동 저감 (Vibration Reduction of Pump and Piping System)

  • 배춘희;원종범;조철환;김성휘;박영필
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 추계학술대회논문집
    • /
    • pp.145-149
    • /
    • 2000
  • In this paper, Firstly, it is shown that the bending mode vibration of check valve is comparatively large because resonance. Secondly in order to decrese the bending mode vibration of check valve, some practical dynamic vibration absorber have been developed and its effectiveness is investigated as installing it at the check valve of piping system practically.

  • PDF