Proceedings of the Korean Society for Noise and Vibration Engineering Conference (한국소음진동공학회:학술대회논문집)
- 2001.05a
- /
- Pages.393-398
- /
- 2001
- /
- 1598-2548(pISSN)
Excess Vibration Phenomena and Soundness of Drain Piping in Moisture Separator Reheat Exchanger
습분 분리 재열기 배수배관의 과도진동과 배관 건전성
- Published : 2001.05.01
Abstract
Pulsations, vibration and stress are the basic dynamic phenomena in power plant piping systems which directly affect system reliability. These phenomena are both acoustical and mechanical in nature and are closely interrelated. It was noticed that thermodynamic parameters were changed after replacing with new type tube bundles of reheat exchanger. It was reported later that the drain piping connecting the new bundle header with the associated drain tank is regularly pulsating at about every 3 second with 13.4㎐ and 7.5mm, p-p in amplitude. This amplitude is about 6 times higher than reference level of sound piping. The results of finite element analysis of the pipeline showed that its dominant natural frequency is 13.4㎐. The soundness is predicted whether the bending dynamic stress evaluated excesses the maximum allowable high cycle fatigue stress or not by the measured amplitude of vibration.
Keywords