• Title/Summary/Keyword: Pipeline structures

Search Result 149, Processing Time 0.024 seconds

A case study of remote wireless monitoring system for stray current due to subway system (지하철 누설전류 무선 원격 감시시스템 적용 사례)

  • Bae, Jeong-Hyo;Ha, Yoon-Cheol
    • Proceedings of the KIEE Conference
    • /
    • 2006.07d
    • /
    • pp.1817-1818
    • /
    • 2006
  • In present, most of metallic structures (gas pipeline, oil pipeline, water pipeline, etc) are running parallel with subway in Seoul and Pusan.In this case, subway system make a stray current due to electrical corrosion on metallic structures. The owner of metallic structures has a burden of responsibility for the protection of corrosion and the prevention against big accident such as gas explosion or soil pollution and so on. So, they have to measure and analyze the data about P/S(Pipe to Soil) potential, amplitude of stray current, point of source of stray current and so on. In this paper, results of development about Wireless Remote Monitoring and Control System on Underground Pipeline in Stray Current Conditions are presented. And also field test data should be reporting.

  • PDF

A Comparative Study of Subsea Pipeline Global Buckling Control Method (해저 파이프라인의 전체 좌굴 제어 방법 비교)

  • Kim, Koo;Kim, Do-Kyun;Choi, Han-Suk;Park, Kyu-Sik
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.6 no.1
    • /
    • pp.51-58
    • /
    • 2015
  • Global buckling is a bending of pipeline and it occurs when the stability of pipeline is distributed by excessive axial force. Subesea pipeline is subjected to axial force induced by temperature and pressure from well and resulting phenomena should be controlled in appropriate manner. Global buckling of subsea pipeline is still ongoing research subject and is studied various organization. In this study, various control methods such as buoyancy module, sleeper, and snake lay for global buckling of subsea pipeline were numerically investigated with various design parameters. From the numerical simulation results, the global buckling control method using sleepers shows better results than buoyancy module and snake lay control methods in the sense of combined stress after buckling. Furthermore, the global buckling of full scale pipeline of 80km with uneven seabed profile were successfully managed when the sleeper was installed.

The Study on the AC Interference of High Power Cable on Underground Gas Pipeline (전력케이블과 가스배관의 병행구간에 대한 교류부식 영향 검토 연구)

  • Bae, J.H.;Kim, D.K.;Ha, T.H.;Lee, H.G.;Kwak, B.M.;Lim, C.J.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.470-473
    • /
    • 2000
  • Because of the continuous growth of energy consumption, and also the tendency to site power lines and pipelines along the same routes, the close proximity of high voltage structures and metallic pipelines has become more and more frequent. Moreover, normal steady state and fault currents become higher as electric networks increase in size and power. Therefore, there has been and still is a growing concern (safety of people marking contact with pipeline, risk of damage to the pipeline coating, the metal and equipment connected to pipeline. especially cathodic protection system) about possible hazards resulting from the influence of high voltage power system on metallic structures(gas pipeline, oil pipeline and water pipeline etc.). Therefore, we analyze the interference problems when the gas pipeline is buried with power cable in the same submarine tunnel. This paper present the results of the study about interference mechanism, AC corrosion, limitation of safety voltage and analysis of indiction voltage.

  • PDF

Synthesis of Pipeline Structures with Variable Data Initiation Intervals (가변 데이터 입력 간격을 지원하는 파이프라인 구조의 합성)

  • 전홍신;황선영
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.31A no.6
    • /
    • pp.149-158
    • /
    • 1994
  • Through high level synthesis, designers can obtain the precious information on the area and speed trade-offs as well as synthesized datapaths from behavioral design descriptions. While previous researches were concentrated on the synthesis of pipelined, datapaths with fixed DII (Data Initiation Interval) by inserting delay elements where needed, we propose a novel methodology of synthesizing pipeline structures with variable DIIs. Determining the time-overlapping of pipeline stages with variable DIIs, the proosed algorithm performs scheduling and module allocation using the time-overlapping information. Experimental results show that significant improvement can be achieved both in speed and in area.

  • PDF

Research on the Analysis Method of Thermal Buckling of Subsea Pipeline Structures (해저 파이프라인 열좌굴 해석방법에 관한 연구)

  • Yang, Seung-Ho;Jung, Jong-Jin;Lee, Woo-Sub;Do, Chang-Ho
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.47 no.2
    • /
    • pp.225-232
    • /
    • 2010
  • The requirement of design of High-Pressure/High-Temperature(HP/HT) pipelines on an seabed increases in recent years. The need of research on the analysis method to improve the design capacity is increasing. The purpose of this study is the development of the analysis method of thermal buckling of subsea pipeline structures. The analysis method of thermal buckling was established by using the commercial FEM code(ABAQUS) which shows the outstanding performance in non-linear static FE analysis. The developed method has been applied to the installation of subsea pipeline on the offshore project. For a validation, the comparative study has been carried out. This application to offshore project demonstrates the superiority of the analysis method of thermal buckling of subsea pipeline structures and testifies the application to detail design.

DATA LOGGER APPARATUS FOR MEASUREMENT STRAY CURRENT OF SUBWAY AND POWER LINE (지하철과 전력선의 누설전류 측정을 위한 저장형 데이터 계측장치)

  • Bae, Jeong-Hyo;Ha, Yun-Cheol;Ha, Tae-Hyeon;Lee, Hyeon-Gu;Kim, Dae-Gyeong
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.731-734
    • /
    • 2003
  • In present, most of metallic structures(gas pipeline, oil pipeline, water pipeline, etc) are running parallel with subway and power line in seoul. Moreover subway system and power line make a stray current due to electrical corrosion on metallic structures. The owner of metallic structures has a burden of responsibility for the protection of corrosion and the prevention against big accident such as gas explosion or soil pollution and so on. So, they have to measure and analyze the data about P/S(Pipe to Soil) potential, amplitude of stray current, point of source of stray current and so. In this paper, results of development about data logger apparatus for measurement stray current of subway and power line are presented.

  • PDF

Study on Transient Flow in Pipeline with Flexible Tube (탄성관을 삽입한 관로에서의 비정상류에 관한 연구)

  • Kim, Young-Joon;Tsukamoto, Hiroshi
    • 유체기계공업학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.825-828
    • /
    • 2005
  • Experimental and numerical study was done to confirm the effect of the flexible tube in pipeline on transient flow oscillation. Experiment was made for a pipeline with and without deformable flexible tube using a single pumping system of main stainless pipe. The wave speeds of main pipe and flexible tube were calculated from the pipe material properties, structures, and boundary conditions. Time dependent pressure fluctuations were calculated for the pipeline using the simple and the Kelvin-Voigt viscoelastic models for the deformation of main pipe and flexible tube. Pressure calculated by the Kelvin-Voigt viscoelastic model showed better agreement with measured one than pressure by the simple model. Experimental and numerical results show that the maximum pressure as well as amplitude of pressure oscillation was decreased by inserting short flexible tube in pipeline. Hence, inserted short flexible tube to pipeline was found to be effective for the suppression of strong pressure oscillation. Moreover, the wave speed in pipe was discussed based on numerical and experimental results.

  • PDF

Analysis of Induced Voltage on the Gas Pipeline at the Fault in a Underground Power Cables (지중전력케이블에서 고장발생시 인근 가스배관에 유도되는 전압 해석)

  • Bae J. H.;Kim D. K.;Kim K. J.
    • Journal of the Korean Institute of Gas
    • /
    • v.4 no.3 s.11
    • /
    • pp.26-32
    • /
    • 2000
  • Because of the continuous growth of energy consumption, and also the tendency to site power lines and pipelines along the same routes, the close proximity of high voltage structures and metallic pipelines has become more and more frequent. Moreover, normal steady state and fault currents become higher as electric networks increase in size and power Therefore, there has been and still is a growing concern(safety of people marking contact with pipeline, risk of damage to the pipeline coating, the metal and equipment connected to pipeline, especially cathodic protection system) about possible hazards resulting from the influence of high voltage power system on metallic structures(gas pipeline, oil pipeline and water pipeline etc.). Therefore, we analyze the interference problems when the gas pipeline is buried with power cable in the same submarine tunnel. This paper present the results of the study about interference mechanism, AC corrosion limitation of safety voltage and analysis of induction voltage.

  • PDF

Three-dimensional numerical parametric study of tunneling effects on existing pipelines

  • Shi, Jiangwei;Wang, Jinpu;Ji, Xiaojia;Liu, Huaqiang;Lu, Hu
    • Geomechanics and Engineering
    • /
    • v.30 no.4
    • /
    • pp.383-392
    • /
    • 2022
  • Although pipelines are composed of segmental tubes commonly connected by rubber gasket or push-in joints, current studies mainly simplified pipelines as continuous structures. Effects of joints on three-dimensional deformation mechanisms of existing pipelines due to tunnel excavation are not fully understood. By conducting three-dimensional numerical analyses, effects of pipeline burial depth, tunnel burial depth, volume loss, pipeline stiffness and joint stiffness on bending strain and joint rotation of existing pipelines are explored. By increasing pipeline burial depth or decreasing tunnel cover depth, tunneling-induced pipeline deformations are substantially increased. As tunnel volume loss varies from 0.5% to 3%, the maximum bending strains and joint rotation angles of discontinuous pipelines increase by 1.08 and 9.20 times, respectively. By increasing flexural stiffness of pipe segment, a dramatic increase in the maximum joint rotation angles is observed in discontinuous pipelines. Thus, the safety of existing discontinuous pipelines due to tunnel excavation is controlled by joint rotation rather than bending strain. By increasing joint stiffness ratio from 0.0 (i.e., completely flexible joints) to 1.0 (i.e., continuous pipelines), tunneling-induced maximum pipeline settlements decrease by 22.8%-34.7%. If a jointed pipeline is simplified as a continuous structure, tunneling-induced settlement is thus underestimated, but bending strain is grossly overestimated. Thus, joints should be directly simulated in the analysis of tunnel-soil-pipeline interaction.

The Field Test of a Mitigation Method from DC Subwaysystem for Underground Pipeline

  • Bae, Jeong-Hyo;Ha, Tae-Hyun;Ha, Yoon-Cheol;Lee, Hyun-Goo;Kim, Dae-Kyeong
    • Corrosion Science and Technology
    • /
    • v.6 no.6
    • /
    • pp.308-310
    • /
    • 2007
  • The owner of underground metallic structures (gas pipeline, oil pipeline, water pipeline, etc) has a burden of responsibility for the corrosion protection in order to prevent big accidents like gas explosion, soil pollution, leakage and so on. So far, Cathodic Protection(CP) technology have been implemented for protection of underground systems. The stray current from DC subway system in Korea has affected the cathodic protection (CP) design of the buried pipelines adjacent to the railroads. In this aspect, KERI has developed a various mitigation method, drainage system through steel bar under the rail, a stray current gathering mesh system, insulation method between yard and main line, distributed ICCP(Impressed Current Cathodic System), High speed response rectifier, restrictive drainage system, Boding ICCP system. We installed the mitigation system at the real field and test of its efficiency in Busan and Seoul, Korea. In this paper, the results of field test, especially, distributed ICCP are described.