• Title/Summary/Keyword: Pipe networks Analysis

Search Result 60, Processing Time 0.027 seconds

A Study on Setting Methods of Economic Level of Leakage in Water Pipe Networks (상수도 관망에서의 경제적인 누수관리목표 산정 방안 연구)

  • Hwang, Jinsoo;Choi, Taeho;Lee, Doojin;Koo, Jayong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.3
    • /
    • pp.237-248
    • /
    • 2017
  • The estimation method of economical leakage management target utilized upon planning business for improvement of revenue water ratio in South Korea is presented and applicability of methods developed in this study is assessed through application on site. With a consideration of revenue water ratio in application target area, estimation method of long-term economical leakage management target is applied. Three leakage reduction methods such as replacement of residual aged pipe, leakage investigation and restoration and water pressure management are applied with a consideration of characteristics of site. Due to difficulty of obtaining data, analysis of cost/benefit by leakage reduction methods is performed by applying method of leakages estimation equation among statistical methods. As a result of application, revenue water ratio corresponding to long-term economical leakage management target is 91.6 %.

Capacity Expansion Modeling of Water-distribution Network using GIS, VE, and LCC (GIS와 VE, LCC 개념에 의한 동적 상수도관망 대안 결정)

  • Kim, Hyeng-Bok
    • Proceedings of the Korean Association of Geographic Inforamtion Studies Conference
    • /
    • 1999.12a
    • /
    • pp.21-25
    • /
    • 1999
  • Planning support systems(PSS) add more advanced spatial analysis functions than Geographic information systems(GIS) and intertemporal functions to the functions of spatial decision support systems(SDSS). This paper reports the continuing development of a PSS providing a framework that facilitates urban planners and civil engineers in conducting coherent deliberations about planning, design and operation & maintenance(O&M) of water-distribution networks for urban growth management. The PSS using dynamic optimization model, modeling-to-generate-alternatives, value engineering(VE) and life-cycle cost(LCC) can generate network alternatives in consideration of initial cost and O&H cost. Users can define alternatives by the direct manipulation of networks or by the manipulation of parameters in the models. The water-distribution network analysis model evaluates the performance of the user-defined alternatives. The PSS can be extended to include the functions of generating sewer network alternatives, combining water-distribution and sewer networks, eventually the function of planning, design and O&H of housing sites. Capacity expansion by the dynamic water-distribution network optimization model using MINLP includes three advantages over capacity expansion using optimal control theory(Kim and Hopkins 1996): 1) finds expansion alternatives including future capacity expansion times, sizes, locations, and pipe types of a water-distribution network provided, 2) has the capabilities to do the capacity expansion of each link spatially and intertemporally, and 3) requires less interaction between models. The modeling using MINLP is limited in addressing the relationship between cost, price, and demand, which the optimal control approach can consider. Strictly speaking, the construction and O&M costs of water-distribution networks influence the price charged for the served water, which in turn influence the. This limitation can be justified in rather small area because price per unit water in the area must be same as that of neighboring area, i.e., the price is determined administratively. Planners and engineers can put emphasis on capacity expansion without consideration of the relationship between cost, price, and demand.

  • PDF

A Study on the Development of the Computer Aided Analysis and Design System of the riping Networks of Industrial Plants (산업플랜트 배관계통의 해석 및 설계시스템 개발에 관한 연구)

  • Yoo Chong Yul;Choi Chang Koon;Lee Chong Won;Oh Jae Wha
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.6 no.4
    • /
    • pp.262-266
    • /
    • 1977
  • A new computer system for the stress analysis and design of piping network has been devlo-ped in this study. For the stress analysis, the system utilizes the finite element technique in which the frontal technique is used as the equation solver. The element library of the system has (1) Pipe Element (2) Beam Element, (3) Hanger Element and (4) Spring Element which should be sufficient to model the entire piping system including flexible supports, joints, piping rack and hangers. Based on the element stresses, code check has been performed and the safety factor for each element is calculated.

  • PDF

Assessing the Spatial Distribution of Perfluorooctanoic Acid Exposure via Public Drinking Water Pipes Using Geographic Information Systems

  • Vieira, Veronica;Hoffman, Kate;Fletcher, Tony
    • Environmental Analysis Health and Toxicology
    • /
    • v.28
    • /
    • pp.9.1-9.5
    • /
    • 2013
  • Objectives Geographic Information Systems (GIS) is a powerful tool for assessing exposure in epidemiologic studies. We used GIS to determine the geographic extent of contamination by perfluorooctanoic acid, C8 (PFOA) that was released into the environment from the DuPont Washington Works Facility located in Parkersburg, West Virginia. Methods Paper maps of pipe distribution networks were provided by six local public water districts participating in the community cross-sectional survey, the C8 Health Project. Residential histories were also collected in the survey and geocoded. We integrated the pipe networks and geocoded addresses to determine which addresses were serviced by one of the participating water districts. The GIS-based water district assignment was then compared to the participants' self-reported source of public drinking water. Results There were a total of 151,871 addresses provided by the 48,800 participants of the C8 Health Project that consented to geocoding. We were able to successfully geocode 139,067 (91.6%) addresses, and of these, 118,209 (85.0%) self-reported water sources were confirmed using the GIS-based method of water district assignment. Furthermore, the GIS-based method corrected 20,858 (15.0%) self-reported public drinking water sources. Over half (54%) the participants in the lowest GIS-based exposure group self-reported being in a higher exposed water district. Conclusions Not only were we able to correct erroneous self-reported water sources, we were also able to assign water districts to participants with unknown sources. Without the GIS-based method, the reliance on only self-reported data would have resulted in exposure misclassification.

Efficient Calculation of External Flow for Transient Simulation in Pipe Networks (상수관망의 수격현상 모의를 위한 외부 유출입 유량의 효율적해석)

  • Park, Jae-Hong;Han, Geon-Yeon
    • Journal of Korea Water Resources Association
    • /
    • v.34 no.5
    • /
    • pp.427-438
    • /
    • 2001
  • A numerical model to analyze the unsteady flow in water distribution system was developed by using wave adjustment method. When analyzing the unsteady flow in the real water distribution system, the computational procedures are very complex due to the various boundary condition. Wave adjustment method, which can solve the boundary condition more simply and accurately, was introduced to overcome this difficulty and related equations to solve external flow directly were presented. Using these equations, the numerical model was developed to analyze water hammer. The suggested model was applied to a hypothetical distribution system and a real system with 26 pipes with various external flow boundary condition to evaluate the applicability of the developed model. The simulation results by this model agree with those by Karney's analysis in terms of discharge and pressure.

  • PDF

Study of Rehabilitation Priority Order of Pipes for Water Distribution Systems using Utopian Approach (Utopian Approach를 이용한 상수관망 개별관로 개량우선순위 산정에 관한 연구)

  • Yoo, Do-Guen;Jun, Hwan-Don;Kim, Joong-Hoon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.2
    • /
    • pp.183-193
    • /
    • 2010
  • Well planned rehabilitation order of pipes is essential for efficient maintenance and management of Water Distribution Systems. In this study, not only deterioration rate of pipes but also structural and nonstructural failure which causes abnormal condition of WDS is considered to determine rehabilitation order. Probabilistic Neural Network is used for calculating deterioration rate at present and the importance of pipes is computed under structural and nonstructural failure by using Pipe by Pipe Failure Analysis and Effect Index. Utopian Approach, one of the Multi-Criteria Decision Making methods, is used for assessment of final rehabilitation order based on distance measure between utopian point and alternative one. Developed model in this study shows that it gives more reliable results than existing methods considering hydraulic relative importance does in application to real networks. In this point, the newly developed model, which gives advantages over existing models, can make a credible decision and simple application.

Simulation and Analysis of a Pipeline Network System for Gas Transportations in Kyungin Area (경인지역 가스 수송을 위한 배관망시스템의 모사 및 분석)

  • Lee Eun-Lyong;Chang Seung-Yong;Kim In-Won
    • 한국가스학회:학술대회논문집
    • /
    • 1997.09a
    • /
    • pp.284-291
    • /
    • 1997
  • 배관망의 해석은 유체역학을 필요로 하며 관내의 유체의 거동과 운전 상태에 따른 유동해석을 위해 여러 식들이 사용되어왔다. 본 연구에서는 정상상태의 유량방정식을 사용해 경인지역가스 배관망에 대한 수학적 모델을 만들고 모사 및 분석을 수행하였다. 개발된 수학적 모델에서 얻어진 데이터에 통계학적인 방법을 도입해 통계학적 모델을 만듦으로써 통계학적 모델을 이용한 배관망 해석의 가능성에 대해 검토하였다.

  • PDF

A Study on the Performance of Automatic Thermostatic Valves for Hot Water Heating System in Residential Buildings (공동주택 난방용 자동온도조절기의 성능해석 연구)

  • Ahn, Byung-Cheon;Lee, Tae-Won;Kim, Yong-Ki;Song, Jae-Yeob
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.457-462
    • /
    • 2005
  • In this study, the performance of automatic thermostatic valves according to each heating method of a large scale residential building were researched by simulation. The flow characteristics of the entire pipe networks of the hot water radiant heating system is analized by using linear analysis method. For the analysis of unsteady heat transfer phenomena in each household, the method of using electric equivalent R-C circuit is applied.

  • PDF

Experimental Analysis of Nodal Head-outflow Relationship Using a Model Water Supply Network for Pressure Driven Analysis of Water Distribution System (상수관망 압력기반 수리해석을 위한 모의 실험시설 기반 절점의 압력-유량 관계 분석)

  • Chang, Dongeil;Kang, Kihoon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.6
    • /
    • pp.421-428
    • /
    • 2014
  • For the analysis of water supply network, demand-driven and pressure-driven analysis methods have been proposed. Of the two methods, demand-driven analysis (DDA) can only be used in a normal operation condition to evaluate hydraulic status of a pipe network. Under abnormal conditions, i.e., unexpected pipe destruction, or abnormal low pressure conditions, pressure-driven analysis (PDA) method should be used to estimate the suppliable flowrate at each node in a network. In order to carry out the pressure-driven analysis, head-outflow relationship (HOR), which estimates flowrate at a certain pressure at each node, should be first determined. Most previous studies empirically suggested that each node possesses its own characteristic head-outflow relationship, which, therefore, requires verification by using actual field data for proper application in PDA modeling. In this study, a model pipe network was constructed, and various operation scenarios of normal and abnormal conditions, which cannot be realized in real pipe networks, were established. Using the model network, data on pressure and flowrate at each node were obtained at each operation condition. Using the data obtained, previously proposed HOR equations were evaluated. In addition, head-outflow relationship at each node was analyzed especially under multiple pipe destruction events. By analyzing the experimental data obtained from the model network, it was found that flowrate reduction corresponding to a certain pressure drop (by pipe destruction at one or multiple points on the network) followed intrinsic head-outflow relationship of each node. By comparing the experimentally obtained head-outflow relationship with various HOR equations proposed by previous studies, the one proposed by Wagner et al. showed the best agreement with the exponential parameter, m of 3.0.

Development of a Dynamic Model for Water Quality Simulation during Unsteady Flow in Water Distribution Networks (부정류 흐름에서 상수관망 수질해석을 위한 동역학적 모형의 개발)

  • Choi, Doo-Yong;Cho, Won-cheol;Kim, Do-Hwan;Bae, Cheol-Ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.5
    • /
    • pp.609-617
    • /
    • 2012
  • A dynamic water quality model is presented in order to simulate water quality under slowly varying flow conditions over time. To improve numerical accuracy, the proposed model uses a lumped system approach instead of extended period simulation, unlike the other available models. This approach can achieve computational efficiency by assuming liquid and pipe walls to be rigid, unlike the method of characteristics, which has been successfully implemented in rapidly varying flows. The discrete volume method is applied to resolve the advection and reaction terms of the transport equation for water quality constituents in pipes. Numerical applications are implemented to the pipe network examples under steady and unsteady conditions as well as hydraulic and water quality simulations. The numerical results are compared with EPANET2, which is a widely used simulation model for a water distribution system. The model results are in good agreement with EPANET2 for steady-state simulation. However, the hydraulic simulation results under unsteady flows differ from those of EPANET2, which causes a deviation in water quality prediction. The proposed model is expected to be a component of an integrated operation model for a water distribution system if it is combined with a computational model for rapidly varying flows to estimate leakage, pipe roughness, and intensive water quality.