도시가스배관 위험평가기술 개발 II - 부식 평가 (Development of Risk Assessment Techniques for City Gas Pipeline II - Corrosion Analysis)

  • 박교식;이진한;조영도;박진희
    • 한국가스학회지
    • /
    • 제7권2호
    • /
    • pp.1-6
    • /
    • 2003
  • 본 연구에서는 이미 개발되어 있는 부식결함의 잔존강도를 평가식을 이용하여 파단, 대누출, 소누출의 손상모드 예측하는 절차를 제시하였다. 또한 이 손상모드에 따라 손상확률을 예측할 수 있는 방법을 제시하고 여기에 부식속도 정보를 결합하면 일정기간 경과 후 손상확률도 예측할 수 있음을 보였다. 이 결과는 노후배관의 수명 또는 교체주기의 예측에 매우 유용하게 활용될 수 있을 것이라 판단된다.

  • PDF

Modeling of Liquid Entrainment and Vapor Pull-Through in Header-Feeder Pipes of CANDU

  • Cho Yong Jin;Jeun Gyoo Dong
    • Nuclear Engineering and Technology
    • /
    • 제36권2호
    • /
    • pp.142-152
    • /
    • 2004
  • The liquid entrainment and vapor pull-through offtake model of RELAP5/MOD3 had been developed for SBLOCA (Small Break Loss of Coolant Accident). The RELAP5/MOD3 model for horizontal volumes accounts for the phase separation phenomena and computes the flux of mass and energy through a branch when stratified conditions occur in the horizontal pipe. In the case of CANDU reactor, this model should be used in the coolant flow of 95 feeders connected to the reactor header component under the horizontal stratification in header. The current RELAP5 model can treat the only 3 directions junctions; vertical upward, downward, and side oriented junctions, and thus improvements for the liquid entrainment and vapor pull-through model were needed for considering the exact angles. The RELAP5 off-take model was modified and generalized by considering the geometric effect of branching angles. Based on the previous experimental results, the critical height correlation was reconstructed by use of the branch line connection angle and validation analyses were also performed using SET. The new model can be applied to vertical upward, downward and angled branch, and the accuracy of the new correlations is more improved than that of RELAP5.

사고사례 정밀분석을 통한 상압저장탱크의 안전에 관한 연구 (A Study on Safety of Atmospheric Storage Tank through Detailed Analysis of Accident Case)

  • 임지표;박수율
    • 한국안전학회지
    • /
    • 제34권4호
    • /
    • pp.41-48
    • /
    • 2019
  • In October 2018, a large fire occurred after an explosion in an internal floating roof tank (IFRT) that stores gasoline by wind lantern in Goyang city, Gyeonggi-do. Although there was no casualty damage, the fire inside the tank lasted for 17 hours, and caused a great wave socially, and it was a chance to review the safety of the atmospheric storage tank. In this study, the necessity of installing a flame arrester at peripheral vents was examined through the calculation of the size of ventilation pipe and ventilation rate of internal floating roof tanks in terms of the function of the peripheral vent. Next, the necessity of the emergency shut-off valve linked with the high-level alarm to prevent the overflow of the atmospheric storage tank was confirmed by LOPA. Finally, safety measures to prevent overpressure, flame propagation and overflow which cause major accidents in atmospheric storage tank are suggested.

Modelling of the fire impact on CONSTOR RBMK-1500 cask thermal behavior in the open interim storage site

  • Robertas Poskas;Kestutis Rackaitis;Povilas Poskas;Hussam Jouhara
    • Nuclear Engineering and Technology
    • /
    • 제55권7호
    • /
    • pp.2604-2612
    • /
    • 2023
  • Spent nuclear fuel and long-lived radioactive waste must be carefully handled before disposing them off to a geological repository. After the pre-storage period in water pools, spent nuclear fuel is stored in casks, which are widely used for interim storage. Interim storage in casks is very important part in the whole cycle of nuclear energy generation. This paper presents the results of the numerical study that was performed to evaluate the thermal behavior of a metal-concrete CONSTOR RBMK-1500 cask loaded with spent nuclear fuel and placed in an open type interim storage facility which is under fire conditions (steady-state, fire, post-fire). The modelling was performed using the ANSYS Fluent code. Also, a local sensitivity analysis of thermal parameters on temperature variation was performed. The analysis demonstrated that the maximum increase in the fuel load temperatures is about 10 ℃ and 8 ℃ for 30 min 800 ℃ and 60 min 600 ℃ fires respectively. Therefore, during the fire and the post-fire periods, the fuel load temperatures did not exceed the 300 ℃ limiting temperature set for an RBMK SNF cladding for long-term storage. This ensures that fire accident does not cause overheating of fuel rods in a cask.

Thermal-hydraulic behaviors of a wet scrubber filtered containment venting system in 1000 MWe PWR with two venting strategies for long-term operation

  • Dong, Shichang;Zhou, Xiafeng;Yang, Jun
    • Nuclear Engineering and Technology
    • /
    • 제52권7호
    • /
    • pp.1396-1408
    • /
    • 2020
  • Filtered containment venting system (FCVS) is one of the severe accident mitigation systems designed to release containment pressurization to maintain its integrity. The thermal-hydraulic behaviors in FCVSs are important since they affect the operation characteristics of the FCVS. In this study, a representative FCVS was modeled by RELAP5/Mod3.3 code, and the Station BlackOut (SBO) was chosen as an accident scenario. The thermal-hydraulic behaviors of an FCVS during long-term operation with two venting strategies (open-and-close strategy, open-and-non-close strategy) and the sensitivity analysis of important parameters were investigated. The results show that the FCVS can operate up to 250 h with a periodic open-and-close strategy during an SBO. Under the combined effects of steam condensation and water evaporation, the solution inventory in the FCVS increases during the venting phase and decreases during the intermission phase, showing a periodic pattern. Under this condition, the appropriate initial water level is 3-4 m; however, it should be adjusted according to the environment temperature. The FCVS can accommodate a decay heat power of 150-260 kW and may need to feed water for a higher decay heat power or drain water for a lower decay heat power during the late phase. The FCVS can function within an opening pressure range from 450 kPa to 500 kPa and a closing pressure range between 250 kPa and 350 kPa. When the open-and-non-close strategy is adopted, the solution inventory increases quickly in the early venting phase due to steam condensation and then decreases gradually due to the evaporation of water; drying-up may occur in the late venting phase. Decreasing the venting pipe diameter and increasing the initial water level can mitigate the evaporation of the scrubbing solution. These results are expected to provide useful references for the design and engineering application of FCVSs.

전압인가식 제전기의 방폭화에 관한 연구 (A study on the explosion proof by the electric discharge on voltage application type)

  • 이춘하;김점호;박민영
    • 한국가스학회지
    • /
    • 제8권4호
    • /
    • pp.62-69
    • /
    • 2004
  • 정전기 방전으로 인한 재해방지, 생산효율의 향상, 정전기 방전에 민감한 전자소자의 보호를 위하여 각종 생산 공정에서는 정전기의 제전이 필요하다. 그래서 필름생산공장, 도장공장, 반도체 공장 등에서 이러한 정전기를 제거하기 위하여 제전기를 사용하고 있다. 본 연구에서는 전압인가식 제전기 bar의 길이, 동관의 길이 및 전극 간격을 변화시켜가면서 최적의 제전효율을 가지는 조건을 고찰하고, 이러한 조건에서 발생되는 방전에 의한 가연성 가스의 폭발 유무를 연구하였다. 그 결과 제전효율은 각각의 제전 bar에서 접지전극과 침상전극 사이의 간격이 8-11(mm)사이 일 때 최적의 제전효율을 나타내는 것을 알 수 있으며, 최적의 제전효율을 나타내는 bar에 대하여 가연성 가스의 폭발실험을 한 결과 폭발은 일어나지 않는 것을 알 수 있었다. 이상과 같이 본 연구를 통하여 나타난 결과를 이용하여 최적의 제전효율과 안전성을 가지는 방폭형 전압인가식 제전기 개발에 필요한 자료를 제시함으로써 산업현장에서 발생하는 가연성 가스에 의한 폭발사고를 미연에 방지할 수 있을 것으로 사료된다.

  • PDF

BPA 공장의 메탄올 분리공정에서 위험성 평가 및 안전대책 (Risk Assessment and Safety Measures for Methanol Separation Process in BPA Plant)

  • 우인성;이중희;이인복;천영우;박희철;황성민;김태옥
    • 한국가스학회지
    • /
    • 제16권3호
    • /
    • pp.22-28
    • /
    • 2012
  • BPA 공장의 메탄올 분리공정에서 HAZOP 평가를 실시하고, 사고 시나리오로부터 화재 및 폭발 사고의 피해범위를 예측하였다. 그 결과, 화재사고의 피해범위는 50 mm 직경의 안전밸브 토출배관 파열에 의한 제트화재에서는 20 m이었고, 설비가 전파되어 플래쉬화재가 발생되는 경우에는 267 m이었다. 또한 개방공간 증기운 폭발사고의 피해범위는 토출배관 파열에서는 22 m이었고, 설비 전파인 경우에는 542 m이었다. 그리고 최악의 누출 시나리오에 대한 안전대책으로는 메탄올 분리컬럼 내부의 이상압력 상승을 감지할 수 있는 압력계를 2 out of 3 voting으로 설비 상부에 설치하여 주공급라인 상에 설치된 컨트롤밸브와 긴급차단밸브를 동시에 차단할 수 있도록 하여야 한다.

적외선 이미지를 이용한 지하공동 평가 (Evaluation of Cavity Characterization Using Infrared Thermal Images)

  • 장병수;김영석;김세원;최현준;윤형구
    • 한국지반공학회논문집
    • /
    • 제39권7호
    • /
    • pp.69-76
    • /
    • 2023
  • 지반의 공동은 지반 침하를 야기하고 사고 발생 후에는 이를 보수하기 위해서도 많은 시간적및 경제적 손실이 발생한다. 본 연구에서는 적외선 카메라를 새로운 계측 수단으로 활용하여 지하 공동의 탐지 가능성을 실험적으로 평가하고자 하였다. 적외선 카메라로 정확한 온도를 평가하기 위해서는 물체에서 방출하는 에너지를 탐지해야 하며 이때 방사율 값이 필수적으로 이용된다. 현장 실험 시 적외선 카메라와 물체의 합리적인 거리를 평가하기 위하여 방사율을 고정하고 거리 변화에 따른 온도 값을 평가하였다. 이를 통해 현장 실험 조건을 구성하였다. 현장 실험의 동공은 5cm 직경의 PVC pipe 관으로 모사하였으며, 지표를 기준으로 5cm와 25cm에 인위적으로 매설하였다. 적외선 카메라는 오후 4시부터 다음날 오후 3시까지(총 23시간) 측정하였으며, 온도의 시계열 분포뿐만 아니라 단위 시간당 변화량인 cooling rate index 방법을 통해서도 분석하였다. 분석결과는 공동 위치에 따라 온도 변화 추세가 상이하게 나타났으며, 이를 통해 적외선 카메라로 지반 내부의 상태를 평가할 수 있는 가능성을 보여준다.

아크릴산 제조공정 사고사례를 통한 소각 시스템의 안전성 향상 방안 (A Study on the Safety Improvement in Incineration System from the Case Study of Acrylic acid manufacturing process Accident)

  • 마병철;이근원;임지표;김영철
    • 한국가스학회지
    • /
    • 제16권4호
    • /
    • pp.52-58
    • /
    • 2012
  • 최근 대기환경규제의 강화로 화학공장에서 발생하는 폐가스를 소각 처리하는 경우가 증대되고 있다. 이러한 소각설비는 저장탱크 상부와 배관을 통해 연결되어 화염을 통하여 폐가스를 연소 소각시키기 때문에, 배관을 따라 화염이 역화될 경우에는 치명적인 사고로 연결될 수 있다. 본 연구는 아크릴산 제조공정의 소각시스템에서 발생한 중대산업사고에 대해 폭발의 3요소와 화염의 전파 원인을 분석하여 사고 예방대책 및 안전성 향상 방안을 다음과 같이 제시하였다. 첫째, 소각시스템의 송풍기를 재 가동하기 전에는 공기 또는 불활성 가스로 충분히 희석하여 폭발을 예방하여야 한다. 둘째, 폭굉으로 전이된 화염이 저장탱크로 전파되지 않도록 소각설비의 전단 및 저장탱크 상부에 폭굉용 화염방지기를 설치하는 것이 필요하다. 섯째, 폭연용 화염방지기를 그대로 사용할 경우에는 그 전단에 파열판을 설치하거나 저장탱크 상부와 소각설비의 배관을 후드식으로 연결하여 폭굉으로 전이된 화염을 저장탱크 밖으로 분출시켜야 한다. 마지막으로, 소각설비에 연결된 송풍기의 제어반(MCC)에 순간정전 보상장치인 시간지연계전기(TDR: time delay relay)등을 설치하여 순간정전 후에도 자동으로 재가동될 수 있도록 조치해야 한다.

증기발생기 전열관의 비파괴 탐상용 차등형 와전류 탐촉자 개발 (Development of Differential Type Eddy Current Probe for NDT Evaluation of the Steam Generator Tube)

  • 정선영;손대락;유권상;박덕근
    • 한국자기학회지
    • /
    • 제15권5호
    • /
    • pp.292-297
    • /
    • 2005
  • 원자력 발전소 증기발생기의 전열관은 전열면으로서의 역할과 방사능 차단벽의 역할로서 중요하며, 증기발생기 튜브의 폭발은 원자력 발전소 사고에 관계된다. 증기발생기 전열관 재료로는 Incone1600이 사용되고 있으며, 이 재료가 금속이면서 비자성이기 때문에 와전류 탐상법으로 전열관의 결함을 탐지하고 있다. 본 연구에서는 탐상 감도를 향상시키기 위하여 차등형 와전류 탐촉자를 개발하였으며, 개발된 차등형 와전류 탐촉자의 성능검사를 위해 Inconel600과 자기적 성질이 비슷하고 구하기 쉬운 SUS304로 가로 100mm, 세로 100mm, 그리고 두께 10mm인 평판에 선형결함과 원형결함을 가공하여 기준시편으로 제작하였다. 제작된 차등형 와전류 탐촉자를 사용하여, 자화주파수 50kHz, lift-off 0.4mm에서 직경이 0.25mm이고, 깊이가 0.2mm 크기의 결함까지 측정이 가능하였다.