Management of Water Distribution Systems Using Optimization Model (관망관리를 위한 최적화 모형의 구성)

  • Lee, Beum-Hee
    • The Journal of Engineering Research
    • /
    • v.4 no.1
    • /
    • pp.137-149
    • /
    • 2002
  • Time passages could deteriorate the flow ability and hold the flow in the water distribution facilities because of their erosion and breakdown. It is necessary that the study to determine the optimal change time and the improvement plan for the continuous management using optimization methods or decision support systems. But, the present study tendency only aware the changes of hydraulic characteristics without industrial management plans. This study shows the pipe replacement program in these two concepts and the elementary process to apply it to Daejeon city.

  • PDF

Development of Optimal Decision-Making System for Rehabilitation of Water Distribution Systems Divided by small Division (상수관망의 구역별 최적개량 의사결정 시스템의 개발)

  • Baek Chun-Woo;Kim Seok-Woo;Kim Eung-Seok;Kim Joong-Hoon;Park Moo-Jong
    • Journal of Korea Water Resources Association
    • /
    • v.39 no.6 s.167
    • /
    • pp.545-552
    • /
    • 2006
  • The purpose of this study is to develop an optimal, long-term planning model for improvement of water distribution networks. The water distribution system is divided into sub-zones and the decision of improvement plan is made for each sub-zone. Costs for replacement, rehabilitation and repair, benefits including reduced pumping and leakage costs, and hydraulic reliability are considered to make optimal decision for improvement planning of water network. Harmony search algorithm is applied to optimize the system and hydraulic analysis model EPANET is interfaced with the optimal decision model to check the hydraulic reliability, The developed model is applied to actual water distribution system in Daegu-city, South Korea. The new model which use durability, conveyance and cost as a decision variable is different from existing methods which use only burying period and pipe type and can be used as optimal decision making system for water distribution network.

Proposal of Concrete Pull Off Bond Strength Measurement Method for Bridge Deck Overlay (교면 덧씌우기 콘크리트의 인발부착강도(引拔附着强度) 시험법(試驗法) 제안(提案))

  • Kim, Seong-Hwan;Kim, Dong-Ho;Kim, Hyun-Oh;Lee, Bong-Hak
    • Journal of Industrial Technology
    • /
    • v.23 no.A
    • /
    • pp.149-156
    • /
    • 2003
  • The development and maintenance of a sound bond are essential requirements of concrete repair and replacement. The bond property of a overlay to its substrate concrete during the lifetime is one of the most important performance requirements which should be quantified. A standard or a verified bond strength measurement method is required at field for screening, selecting materials and quality control for overlay or repair materials, but no test method has been adopted as a standard. In this study, a concrete pull off bond strength measurement method for field application is proposed and evaluated. This study compares the splitting tensile test, slant shear test, nipple pipe direct tensile test, flexural adhesion test, briquette tensile test, jumbo nail pull-out test and core pull-off test with their test procedures. From these comparison and investigation, core pull-off test is selected as a main topic of this study because of it's suitability for in situ testing, simplicities in field application and clearness at interface boundary condition. Thus, the proposed core pull off test is evaluated to be the most appropriate method for field application in a simple manner. The fracture surface and fracture mode could be easily determined by visual observation of failure surface of the field specimen. The core pull off test was found to be sensitive to surface condition and latex contents at latex modified concrete.

  • PDF

Mineralogy and Genesis of Fe-Cu and Au-Bi-Cu Deposits in the Geodo Mine, Korea (거도광산(巨道鑛山) Fe-Cu 및 Au-Bi-Cu 광상(鑛床)에 대(對)한 광물학적(鑛物學的) 및 성인적(成因的) 연구(硏究))

  • Ko, Jai Dong;Kim, Soo Jin
    • Economic and Environmental Geology
    • /
    • v.15 no.4
    • /
    • pp.189-204
    • /
    • 1982
  • The Geodo mine is located in the southern limb of the Hambaeg syncline. Geology of the area consists of Paleozoic-Mesozoic sedimentary Rocks and Cretaceous igneous rocks. The important igneous rocks presumably related to skarnization and ore mineralization in the area, are the early granodiorite and the late porphyritic granodiorite. Two mineralogical types of ore deposits are recognized in the area. They are the Fe-Cu deposits in the Myobong formation and the Au-Bi-Cu deposits in the Hwajeol formation. Contact metamorphism due to granodiorite intrusion includes hornfelsization, exoskarnization and endoskarnization. Wall-rock alterations related to the Fe mineralization are grouped into the hydrothermal replacement skarnization and the hydrothermal filling skarnization. Another hydrothermal alteration is associated with the Cu mineralization. Various mineralogical analyses have been applied for the identification of minerals. They include optical microscopy, chemical analysis, etching test, X-ray diffraction, and infrared absorption spectroscopic analyses. The ore minerals in these ore deposits are classified into two groups;hypogene and supergene minerals. Hypogene minerals consist of magnetite, pyrite, chalcopyrite, and chalcocite. Supergene minerals consist of chalcocite, bornite, and geothite. Ore minerals show various kinds of ore texture: open-space filling, exsolution, replacement, and cementation texture. The gangue minerals consist of quartz, diopside, epidote, garnet and plagioclase in the hornfelsic zone, garnet, diopside, scapolite, actinolite, sericite, chlorite, quartz, and calcite in the skarn zone, and, epidote, chlorite, sericite, quartz, and calcite in the late hydrothermal alteration zone. This study shows that the Fe-Cu deposits are of metasomatic pipe type with the later hydrothermal fillings, and the Au-Bi-Cu deposits are of hydrothermal fissure-filling type. The mineralization is probably related to the intrusion of porphyritic granite.

  • PDF

Efficiency evaluation of water leakage management methods in local small and medium cities (지방중소도시의 누수관리방법에 대한 효율성 평가)

  • Hwang, Jinsoo;Choi, Taeho;Kim, Kibum;Koo, Jayong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.35 no.2
    • /
    • pp.121-133
    • /
    • 2021
  • This study set up the estimates of leakage management efficiency evaluation and leakage management goal that could be used in local water distribution networks efficiency business and modernization business. The data were analyzed using data envelopment analysis and multiple regression analysis. To this end, with leakage management input indices concerning leakage reduction activities (e.g., aged pipe replacement, water meter replacement, leakage restoration, and leakage detection) and leakage management calculation indices (e.g., the increase of revenue water ratio and the reduction of leakage ratio), the data on 22 K-water consignment local water supply systems were analyzed for the years from 2004 through 2018. Using the results of efficiency analysis by data envelopment analysis, the other DMUs (Decision Making Unit) benchmarked the DMU with the highest efficiency to maximize the leakage management efficiency for all DMUs. Through this, leakage management goal estimates were drawn with the input indices of four leakage reduction activities and calculation indices of the increase of revenue water ratio and the reduction of leakage ratio by multiple regression analysis for each group based on the revenue water ratio and leakage ratio. The correlation coefficients of the leakage management goal estimate for the criteria for the revenue water ratio amounted to 0.553 and 0.771. The correlation coefficients of the leakage management goal estimate for the criteria for leakage ratio were 0.397 and 0.865. Accordingly, we estimated the quantity and priority of four leakage reduction activities for the target leakage ratio and revenue water ratio.

Development of Residual Tensile Strength Prediction Model for Metallic Water Pipes (상수도 금속관의 잔존 인장강도 추정모델 개발)

  • Bae, Chulho;Kim, Jeonghyun;Woo, Hyungmin;Hong, Seongho
    • Journal of the Korean GEO-environmental Society
    • /
    • v.9 no.3
    • /
    • pp.17-28
    • /
    • 2008
  • In this study, the residual strength prediction models were proposed by measuring various residual strength according to pit characteristics for metallic water pipes such as cast iron pipe (CIP), ductile iron pipe (DIP), and steel pipe (SP). The exponential prediction model was better fitted to measured residual tensile strength for CIP. In case of DIP and SP, the prediction model using loss of strength was more exactly predicted compared with other model types. The fracture toughness were averagely $40.46kgf/mm^2{\sqrt{mm}}$ for CIP, $85.27kgf/mm^2{\sqrt{mm}}$ for DIP, and $92.27kgf/mm^2{\sqrt{mm}}$ for SP, the determination coefficient ($R^2$) of between measured residual tensile strength and predicted values for residual strength prediction models using fracture toughness was estimated from 0.44 to 0.86. Especially, the proposed residual tensile strength prediction models were applied for the verification and reliability to CIPs and DIPs at 14 sites. The determination coefficient ($R^2$) between measured residual tensile strength and predicted values was estimated from 0.76 to 0.78. Therefore it was thought that the proposed residual tensile strength models could help to support resonable and economical decision of rehabilitation/replacement.

  • PDF

Introduction and Feasibility on a New Technology for the Pipe Wall Thinning Evaluation of Nuclear Power Plants (원전 배관감육 평가를 위한 새로운 기법의 도입 및 타당성)

  • Hwang, Kyeong Mo;Yun, Hun;Park, Hyun Cheol
    • Corrosion Science and Technology
    • /
    • v.13 no.2
    • /
    • pp.62-69
    • /
    • 2014
  • A huge number of carbon steel piping components installed in the secondary system of nuclear power plants are exposed to aging mechanisms such as FAC (Flow-Accelerated Corrosion), Cavitation, Flashing, and LDIE (Liquid Droplet Impingement Erosion). Those aging mechanisms can lead to thinning of the piping components. To manage the wall thinning degradation, most of utilities in the world predict the wall thinning rate based on the computational program such as CHECWORKS, COMSY, and BRT-CICERO, evaluate the UT (Ultrasonic Test) data, and determine next inspection timing, repair or replacement, if needed. There are several evaluation methods, such as band, blanket, and strip methods, commonly used for determining the wear of piping components from single UT inspection data. It has been identified that those single UT evaluation methods not only do not consider the manufacturing features of pipes, but also may exclude the data of the most thinned point when determining the representative wear rate of piping components. This paper describes a newly developed single UT evaluation method, E-Cross method, for solving above problems and introduces application examples for several pipes and elbows. It was identified that the E-Cross method using the length and width of UT data excluded the most thinned points appropriate as the single UT evaluation method for thinned piping components.

A Study on Risk Evaluation Method of Ground Subsidence around Sewer (하수관로 주변 도로함몰 위험도 평가 방법에 관한 연구)

  • Kim, Jinyoung;Choi, Changho
    • Journal of the Korean GEO-environmental Society
    • /
    • v.19 no.7
    • /
    • pp.13-18
    • /
    • 2018
  • Recently, road subsidence has been increasing in urban areas, threatening the safety of citizens. In the lower part of the road, various road facilities such as water supply and drainage pipelines and telecommunication facilities are buried, and the deterioration of the facilities causes the road subsidence. In particular, in the case of old sewer pipes which are attracting attention as a main cause of road subsidence, the management of sewer pipe replacement, repair and reinforcement is being performed depending on the burial year. Therefore, in this study, we tried to suggest a reliable road subsidence risk assessment method considering various sewer specifications and surrounding environment information and CCTV exploration result and GPR exploration result.

Leveraging the Smart device for waterworks manhole management (상수도맨홀 관리를 위한 스마트 관리장치의 활용)

  • Chun, Haebok;Kim, Yeongkwan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.2
    • /
    • pp.141-148
    • /
    • 2017
  • The waterworks company is in charge of managing water facilities buried underground, and the management has been centered on manholes. However, since there is no standard management manual, it has been impossible to introduce and operate a systemized managing tool by water service providers and managers, and manhole management has been carried out by individual data recording personnel for each water service provider. When the management is carried out individually, the data to be shared by other waterworks managers tend to be privatized, and consequently, it may become a big obstacle to proceed with many civil works such as emergency leak repair, road excavation, replacement of old buildings. This report introduces RFID (Radio Frequency Identification) system which is based on the magnetic field capable of IOT. It also describes the necessity of leveraging the system for smart managing of pipe management record that has been done by hand writing. The RFID system includes RFID marker, data reader, portable computer operating program, and data base server operating program. In this system, the data is managed with a single communication device, and it would be possible to share the information on the underground facilities and water treatment facilities. This RFID technology is expected to provide water service providers with opportunities to develop more scientific and modernized underground facilities information systems.

Acid Resistance of Unsaturated Polyester Mortar Using Crushed Wate Glass (폐유리를 골재로 사용한 불포화폴리에스테르 모르타르의 내산성에 관한 연구)

  • 한창호;최길섭;김완기;조영국;소양섭
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.04a
    • /
    • pp.339-342
    • /
    • 2000
  • Recently, the importance of the conutermeasures for waste materials has pointed out. Waste glass is also one to waste materials used for the recycling in construction sites. The crushed waste glass has been used to make a glass polymer composite that can be applied for sewer, storm drain pipe and interlocking block, etc. In this study, the crushed waste glass is explored with the possibility of recycling it, as a substitute for fine aggregates. The prepose of this investigation is to improve the strengths and acid resistance of the UP mortars using crushed waste glass. The UP mortars are prepare with blast furnace slag fly ash filler. the UP-fine aggregate ratios the crushed waste glass replacements for fine aggregate are tested strengths before and after immersion(H (아래첨자2)SO(아래첨자4) 10%), weight change and acid resistance are also tested. From the test results, the relative strength or UP mortars using fly ash as filler are found to be somewhat superior to that of the UP mortars using blast furnace as filler, And a UP mortar with fly ash as a filler, a UP-fine aggregate ratio of 15% and a waste glass replacement if 50% for fine aggregate is recommended as optimal mix proportion of UP mortar using crushed waste glass. Accordingly, it is enough to assure the use of the crushed waare glass as an aggregate for the production of UP mortar.

  • PDF