• Title/Summary/Keyword: Pipe Flow

Search Result 1,655, Processing Time 0.023 seconds

Retrospective analysis of the urban inundation and the impact assessment of the flood barrier using H12 model (H12 모형을 이용한 도시침수원인 및 침수방어벽의 효과 분석)

  • Kim, Bomi;Noh, Seong Jin;Lee, Seungsoo
    • Journal of Korea Water Resources Association
    • /
    • v.55 no.5
    • /
    • pp.345-356
    • /
    • 2022
  • A severe flooding occured at a small urban catchment in Daejeon-si South Korea on July 30, 2020 causing significant loss of property (inundated 78 vehicles and two apartments) and life (one casualty and 56 victims). In this study, a retrospective analysis of the inundation event was implemented using a physically-based urban flood model, H12 with high-resolution data. H12 is an integrated 1-dimensional sewer network and 2-dimensional surface flow model supported by hybrid parallel techniques to efficiently deal with high-resolution data. In addition, we evaluated the impact of the flooding barriers which were installed after the flood disaster. As a result, it was found that the inundation was affected by a combination of multiple components including the shape of the basin, the low terrain of the inundation area located in the downstream part of the basin, and lack of pipe capacity to drain discharge from the upstream during heavy rain. The impact of the flooding barriers was analyzed by modeling with and without barriers on the high-resolution terrain input data. It was evaluated that the flood barriers effectively lower the water depth in the apartment complex. This study demonstrates capability of high-resolution physically-based urban modeling to quantitatively assess the past inundation event and the impact of the reduction measures.

A Study on the Comparison between an Optical Fiber and a Thermal Sensor Cable for Temperature Monitoring (온도 모니터링을 위한 광섬유 센서와 온도센서 배열 케이블의 비교 연구)

  • Kim, Jung-Yul;Song, Yoon-Ho;Kim, Yoo-Sung
    • Journal of the Korean Geotechnical Society
    • /
    • v.23 no.4
    • /
    • pp.15-24
    • /
    • 2007
  • Two kinds of temperature monitoring technology have been introduced in this study, which can measure coincidently temperatures at many points along a single length of cable. One is to use a thermal sensor cable comprizing of addressable thermal sensors. The other is to use an optic fiber sensor with Distributed Temperature Sensing (DTS) system. The differences between two technologies can be summarized as follows: A thermal sensor cable has a concept of "point sensing" that can measure temperature only at a predefined position. The accuracy and resolution of temperature measurement are up to the capability of the individual thermal sensor. On the other hand, an optic fiber sensor has a concept of "distributed sensing" because temperature is measured practically at all points along the fiber optic cable by analysing the intensity of Raman back-scattering when a laser pulse travels along the fiber. Thus, the temperature resolution depends on the measuring distance, measuring time and spatial resolution. The purpose of this study is to investigate the applicability of two different temperature monitoring techniques in technical and economical sense. To this end, diverse experiments with two techniques were performed and two techniques are applied under the same condition. Considering the results, the thermal sensor cable will be well applicable to the assessment of groundwater flow, geothermal distribution and grouting efficiency within about loom distance, and the optic fiber sensor will be suitable for long distance such as pipe line inspection, tunnel fire detection and power line monitoring etc.

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2012 (설비공학 분야의 최근 연구 동향 : 2012년 학회지 논문에 대한 종합적 고찰)

  • Han, Hwataik;Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Choi, Jong Min;Park, Jun-Seok;Kim, Sumin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.6
    • /
    • pp.346-361
    • /
    • 2013
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2012. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. The conclusions are as follows : (1) The research works on thermal and fluid engineering have been reviewed as groups of fluid machinery, pipes and valves, fuel cells and power plants, ground-coupled heat pumps, and general heat and mass transfer systems. Research issues are mainly focused on new and renewable energy systems, such as fuel cells, ocean thermal energy conversion power plants, and ground-coupled heat pump systems. (2) Research works on the heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer, and industrial heat exchangers. Researches on heat transfer characteristics included the results for natural convection in a square enclosure with two hot circular cylinders, non-uniform grooved tube considering tube expansion, single-tube annular baffle system, broadcasting LED light with ion wind generator, mechanical property and microstructure of SA213 P92 boiler pipe steel, and flat plate using multiple tripping wires. In the area of pool boiling and condensing heat transfer, researches on the design of a micro-channel heat exchanger for a heat pump, numerical simulation of a heat pump evaporator considering the pressure drop in the distributor and capillary tubes, critical heat flux on a thermoexcel-E enhanced surface, and the performance of a fin-and-tube condenser with non-uniform air distribution and different tube types were actively carried out. In the area of industrial heat exchangers, researches on a plate heat exchanger type dehumidifier, fin-tube heat exchanger, an electric circuit transient analogy model in a vertical closed loop ground heat exchanger, heat transfer characteristics of a double skin window for plant factory, a regenerative heat exchanger depending on its porous structure, and various types of plate heat exchangers were performed. (3) In the field of refrigeration, various studies were executed to improve refrigeration system performance, and to evaluate the applicability of alternative refrigerants and new components. Various topics were presented in the area of refrigeration cycle. Research issues mainly focused on the enhancement of the system performance. In the alternative refrigerant area, studies on CO2, R32/R152a mixture, and R1234yf were performed. Studies on the design and performance analysis of various compressors and evaporator were executed. (4) In building mechanical system research fields, twenty-nine studies were conducted to achieve effective design of mechanical systems, and also to maximize the energy efficiency of buildings. The topics of the studies included heating and cooling, HVAC system, ventilation, renewable energy systems, and lighting systems in buildings. New designs and performance tests using numerical methods and experiments provide useful information and key data, which can improve the energy efficiency of buildings. (5) In the fields of the architectural environment, studies for various purposes, such as indoor environment, building energy, and renewable energy were performed. In particular, building energy-related researches and renewable energy systems have been mainly studied, reflecting interests in global climate change, and efforts to reduce building energy consumption by government and architectural specialists. In addition, many researches have been conducted regarding indoor environments.

Effects of Tile Drain on Physicochemical Properties and Crop Productivity of Soils under Newly Constructed Plastic Film House (신설 하우스 시설재배지의 파이프 암거배수 효과)

  • Kim, Lee-Yul;Cho, Hyun-Jun;Han, Kyung-Hwa
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.36 no.3
    • /
    • pp.154-162
    • /
    • 2003
  • This study was conducted to investigate the effects of tile drain on Physicochemical properties and crop productivity of soils under plastic film house for three years (1999 - 2001). Tiles (${\Phi}100mm$ PVC pipe) were established at 50-60 cm depth with 1 m, 2 m, and 3 m intervals in Gangseo silt loam soil under 2W-type plastic film house. Cropping system was a pumpkin-pumpkin in the first year, a cucumber-spinach-crown daisy-spinach-young radish in the second year, and a green red pepper-tomato-spinach in last year, with conventional fertilization and drip or furrow irrigation by groundwater pumping. Bulk density and soil hardness of plot with tile drain were lower than those of control (plot without tile drain). Soil water content was also lower in tile drain plot than in control regardless of soil depth, and decreased at narrower interval and longer distance from tile in the same plot, thus suggesting that water flow and density of tile drain plot was higher than those of control. Rhizosphere of spinach, a final crop of third year, was expanded more than 2 cm due probably to improvement of soil physical properties caused by tiles establishment. Electrical conductivity (EC) of topsoil decreased from $1.22dS\;m^{-1}$ to $0.82dS\;m^{-1}$ by tile drain system, and the extent of EC decrease was different with season: higher in spring and lower in summer and autumn. The $NO_{3^-}-N$ concentration in topsoil decreased, from $200mg\;kg^{-1}$ to $39mg\;kg^{-1}$. The effect of tile drain on crop yield varied with crops. Average crop productivity obtained in tile drain plot than that of control crop: 18.2% in 2 m interval, 14.2% in 3 m interval, but lower 0.2% in 1 m interval.

A Study on the Cause and Improvement of the Red-Water Occurrence in Urban Stream (도심하천 내 적수발생 지점에 대한 원인검토 및 개선방안 연구)

  • Beomjin Eun;Jong Hwan Kim;Zi Yu Lin;Jeong Sook Heo;I Song Choi;Jong-Min Oh
    • Journal of Environmental Impact Assessment
    • /
    • v.32 no.3
    • /
    • pp.166-175
    • /
    • 2023
  • This study aims to identify the cause of the red-water occurrence (the phenomenon of water being red) that occurs at some points and sections of rivers in Yongin City. As a result of conducting a preliminary investigation, total three sites were selected as the investigation point as it was found that the red-water occurrence continued. As a result of the investigation, it is judged that the cause of the red-water in Yongin-city river is due to the soil color and iron content of the region. JPS, SBS, and JJS sites all showed that the color of soil is mainly consist of reddish brown and red-yellow. The average Fe concentration was 13.75 mg/L, 10.85 mg/L, and 1.31 mg/L, for each sites, and considering that the Fe concentration in general river water was less than 0.5 mg/L, it was confirmed that the concentration was quite high. At the JPS and JJS points, the red-water occurrence occurred mainly in stagnant places, which is believed to be strengthened by the reaction of organic and microorganisms. In the case of SBS, the wateris red, but as a result of observing the actual color, it is judged that the iron component deposited in the pipe causes an optical illusion with a deep red color. In addition, it is believed that the iron concentration can be reduced to the general river water concentration range by removing the particulate iron component through a decrease of more than 95% as a result of filtering with glass fiber filter with particulate iron. As a result of this study, it is necessary to manage the river to maintain the flow, and it is believed that the occurrence of red-water at the survey point can be alleviated through uptake action through planting and agglomeration precipitation and agglomeration filtration methods for particulate iron treatment.