• 제목/요약/키워드: Pin-ended column

검색결과 6건 처리시간 0.02초

Simplified Design Procedure for Reinforced Concrete Columns Based on Equivalent Column Concept

  • Afefy, Hamdy M.;El-Tony, El-Tony M.
    • International Journal of Concrete Structures and Materials
    • /
    • 제10권3호
    • /
    • pp.393-406
    • /
    • 2016
  • Axially loaded reinforced concrete columns are hardly exist in practice due to the development of some bending moments. These moments could be produced by gravity loads or the lateral loads. First, the current paper presents a detailed analysis on the overall structural behavior of 15 eccentrically loaded columns as well as one concentrically loaded control one. Columns bent in either single curvature or double curvature modes are tested experimentally up to failure under the effect of different end eccentricities combinations. Three end eccentricities ratio were studied, namely, 0.1b, 0.3b and 0.5b, where b is the column width. Second, an expression correlated the decay in the normalized axial capacity of the column and the acting end eccentricities was developed based on the experimental results and then verified against the available formula. Third, based on the equivalent column concept, the equivalent pin-ended columns were obtained for columns bent in either single or double curvature modes. And then, the effect of end eccentricity ratio was correlated to the equivalent column length. Finally, a simplified design procedure was proposed for eccentrically loaded braced column by transferring it to an equivalent axially loaded pin-ended slender column. The results of the proposed design procedure showed comparable results against the results of the ACI 318-14 code.

트러스로 보강된 단일기둥시스템의 탄성좌굴강도에 대한 연구 (A Study on Elastic Buckling Strength of Truss-Stayed Single Column System)

  • 김경식
    • 한국산학기술학회논문지
    • /
    • 제12권12호
    • /
    • pp.5984-5989
    • /
    • 2011
  • 양단 핀지지 기둥부재의 중간 위치에 수평재를 연결하고 설치된 수평재의 양끝단과 기둥의 상하끝단을 트러스로 연결된 트러스보강 단일기둥시스템은 보강되지 않은 경우에 비해 그 좌굴강도가 상당수준 향상될 수 있다. 수평재가 설치된 기둥중간지점에서의 수평 및 회전 자유도에 대한 제한하여 기둥의 유효좌굴길이를 줄이는 효과를 통해 강도향상이 구현된다. 본 연구에서는 해석적 해와 탄성 및 비탄성 유한요소해석을 통해 보강된 평면내 단일기둥 시스템의 좌굴강도를 정량적으로 산정하였고 그 결과를 비교하였다. 예제해석을 통해 보강된 단일기둥시스템은 보강되지 않은 단순기둥에 비해 최대 8배까지 좌굴강도가 향상될 수 있음이 확인되었다.

Behavior of lightweight aggregate concrete-encased composite columns

  • Al-Shahari, Abbas M.;Hunaiti, Yasser M.;Ghazaleh, Bassam Abu
    • Steel and Composite Structures
    • /
    • 제3권2호
    • /
    • pp.97-110
    • /
    • 2003
  • An experimental study was conducted to investigate the behavior of eccentric lightweight aggregate concrete-encased composite columns. This study aims at verifying the validity of such type of concrete in composite construction and checking the adequacy of the AISC-LRFD and the British Bridge Code BS 5400 specifications in predicting the column strength. Sixteen full-scale pin ended columns subjected to uniaxial bending about the major axis in symmetrical single curvature were tested.

Member capacity of columns with semi-rigid end conditions in Oktalok space frames

  • Zhao, Xiao-Ling;Lim, Peter;Joseph, Paul;Pi, Yong-Lin
    • Structural Engineering and Mechanics
    • /
    • 제10권1호
    • /
    • pp.27-36
    • /
    • 2000
  • The Oktalok nodal connection system is an aesthetic and efficient system. It has been widely used throughout Australia. The paper will briefly introduce the concept and application of the Oktalok nodal system. The existing design method is based on the assumption that the joints are pin-ended, i.e., the rotational stiffness of the joints is zero. However the ultimate capacity of the frame may increase significantly depending on the rotational stiffness of the joints. Stiffness tests and finite element simulations were carried out to determine the rotational stiffness of the Oktalok joints. Column buckling tests and non-linear finite element analyses were performed to determine the member capacity of columns with semi-rigid end conditions. A simple formulae for the effective length factor of column buckling is derived based on the above experimental and theoretical investigations.

Boundary Conditions and Fire Behavior of Concrete Filled Tubular Composite Columns

  • Rodrigues, Joao Paulo C.;Correia, Antonio J.M.;Kodur, Venkatesh
    • 국제초고층학회논문집
    • /
    • 제7권4호
    • /
    • pp.313-325
    • /
    • 2018
  • Concrete-filled steel tubular (CFST) members are commonly used as composite columns in modern construction. However, the current guidelines for members' fire design (EN1994-1-2) have been proved to be unsafe in case the relative slenderness is higher than 0.5. In addition, the simplified design methods of Eurocode 4 are limited to circular and square CFST columns, while in practice columns with rectangular and elliptical hollow sections are being increasingly used because of their architectural aesthetics. In the last years a large experimental research has been carried out at Coimbra University on the topic. They have been tested concrete filled circular, square, rectangular and elliptical hollow columns with restrained thermal elongation. Some parameters such as the slenderness, the type of cross-section geometry as well as the axial and rotational restraint of the surrounding structure to the column have been tested in order to evaluate their influence on the fire resistance of such columns. In this paper it is evaluated the influence of the boundary conditions (pin-ended and semi-rigid end-support conditions) on the behavior of the columns in case of fire. In these tests it could not be seen a marked effect of the tested boundary conditions but it is believed that the increasing of rotational stiffness increases the fire resistance of the columns.

A comprehensive FE model for slender HSC columns under biaxial eccentric loads

  • Lou, Tiejiong;Lopes, Sergio M.R.;Lopes, Adelino V.;Sun, Wei
    • Structural Engineering and Mechanics
    • /
    • 제73권1호
    • /
    • pp.17-25
    • /
    • 2020
  • A finite element (FE) model for analyzing slender reinforced high-strength concrete (HSC) columns under biaxial eccentric loading is formulated in terms of the Euler-Bernoulli theory. The cross section of columns is divided into discrete concrete and reinforcing steel fibers so as to account for varied material properties over the section. The interaction between axial and bending fields is introduced in the FE formulation so as to take the large-displacement or P-delta effects into consideration. The proposed model aims to be simple, user-friendly, and capable of simulating the full-range inelastic behavior of reinforced HSC slender columns. The nonlinear model is calibrated against the experimental data for slender column specimens available in the technical literature. By using the proposed model, a numerical study is carried out on pin-ended slender HSC square columns under axial compression and biaxial bending, with investigation variables including the load eccentricity and eccentricity angle. The calibrated model is expected to provide a valuable tool for more efficiently designing HSC columns.