• 제목/요약/키워드: Pin to pin

검색결과 2,304건 처리시간 0.028초

Removable implant-supported partial denture using milled bar with Locator® attachments in a cleft lip & palate patient: A clinical report (구순구개열 환자에서 Locator® 유지장치가 장착된 milled titanium bar를 이용한 가철성 임플란트 피개 국소의치의 보철수복증례)

  • Yang, Sang-Hyun;Kim, Kyoung-A;Kim, Ja-Yeong;Seo, Jae-Min
    • The Journal of Korean Academy of Prosthodontics
    • /
    • 제53권3호
    • /
    • pp.207-214
    • /
    • 2015
  • Due to the limitations of conventional removable partial denture prostheses to treat a cleft lip & palate patient who shows scar tissue on upper lip, excessive absorption of the maxillary residual alveolar ridge, and class III malocclusion with narrow palate and undergrowth of the maxilla, 4 implants were placed on the maxillary edentulous region and a maxillary removable implant-supported partial denture was planned using a CAD/CAM milled titanium bar. Unlike metal or gold casting technique which has shrinkage after the molding, CAD/CAM milled titanium bar is highly-precise, economical and lightweight. In practice, however, it is very hard to obtain accurate friction-fit from the milled bar and reduction in retention can occur due to repetitive insertion and removal of the denture. Various auxiliary retention systems (e.g. $ERA^{(R)}$, $CEKA^{(R)}$, magnetics, $Locator^{(R)}$ attachment), in order to deal with these problems, can be used to obtain additional retention, cost-effectiveness and ease of replacement. Out of diverse auxiliary attachments, $Locator^{(R)}$ has characteristics that are dual retentive, minimal in vertical height and convenient of attachment replacement. Drill and tapping method is simple and the replacement of the metal female part of $Locator^{(R)}$ attachment is convenient. In this case, the $Locator^{(R)}$ attachment is connected to the milled titanium bar fabricated by CAD/CAM, using the drill and tapping technique. Afterward, screw holes were formed and 3 $Locator^{(R)}$ attachments were secured with 20 Ncm holding force for additional retention. Following this procedure, satisfactory results were obtained in terms of aesthetic facial form, masticatory function and denture retention, and I hereby report this case.

Compressive Behavior of Precast Concrete Column with Hollow Corresponding to Hollow Ratio (중공비율에 따른 중공 프리캐스트 철근콘크리트 기둥의 압축거동)

  • Lee, Seung-Jun;Seo, Soo-Yeon;Pei, Wenlong;Kim, Kang-Su
    • Journal of the Korea Concrete Institute
    • /
    • 제26권4호
    • /
    • pp.441-448
    • /
    • 2014
  • From several researches, recently, it was found that using hollowed precast concrete (HPC) column made more compact concrete casting in joint region possible than using normal solid PC (Precast concrete) column. Therefore, the rigidity of joints can be improved like those of monolithic reinforced concrete (RC). After filling the hollow with grout concrete, however, it is expected that the HPC column behaviors like composite structure since PC element and grout concrete have different materials as well as there is a contact surface between two elements. These may affect the structural behavior and strength of the composite column. A compressive strength test was performed for the HPC column with parameter of hollow ratio for the case with and without grout in the hollow and the result is presented in this paper. The hollow ratios in the test are 35, 50 and 59% of whole section of column. Concentrated axial force was applied to top of the specimens supported as pin connection for both ends. In addition, finite element (FE) analysis was performed to simulate the failure behavior of HPC column for axial compression. As a result, it was found that the hollow ratio did not affect the initial stiffness of HPC filled with grout regardless of the strength difference of HPC and grout. However the strength was increased inversely corresponding to the hollow ratio. The structural capacity of HPC without grout closely related to the hollow size. Especially, the local collapse governs the overall failure when the thickness of HPC is too thin. Based on these effect, a suitable equation was suggested for calculation of the compressive strength of HPC column with or without grout. FE analysis considering the contact surface between HPC and grout produced a good result matched to the test result.

The Growth Characteristics of Pleurotus eryngii (큰느타리버섯의 자실체 생육특성)

  • Ryu, Jae-San;Kim, Min-Keun;Kwon, Jin-Hyeuk;Cho, Sook-Hyun;Kim, Nak-Ku;Rho, Chi-Wong;Lee, Chun-Hee;Ro, Hyeon-Su;Lee, Hyun-Sook
    • The Korean Journal of Mycology
    • /
    • 제35권1호
    • /
    • pp.47-53
    • /
    • 2007
  • In this study, we investigated the properties of incubation and growing of Pleurotus eryngii in addition to the mycological properties to use them as basic data for breeding. The speed of mycelial growth on the MCM was faster than on the PDA. The biomass in the PDB broth culture was higher than in the MCM and YMG broth culture. KNR2515 and KNR2516 required 19 days for growth of mycelia on commercial sawdust media. KNR2503 required 6.5 days and 15.3 days for pin-heading and harvesting, respectively. In morphological properties by the mushroom, the heights of KNR2312 and KNR2322 were 122.7 and 121.0 mm, respectively. The thickness of KNR2322 and KNR2513 were 39.8 mm and 31.3 mm, respectively. The weight of KNR2524's fruiting body was 36.3 g, which is good as wild strain. The quality of fruiting body of KNR2503 was 4.0 in comparison to the score 7 of commercially cultivated strains. KNR2512 had the darkest color of pileus with L value 43.6. The slow growing strains, KNR2511, KNR2513, and KNR2512 had the bright pileus with L value 80. In morphological characteristics, KNR2511, KNR2513, and KNR2515 had white lamellar and plane pileus. The three strains are supposed to be the same group and KNR2516 and KNR2518 appeared to be related to the group. The commercially cultivated strains had convex pileus, KNR2502, KNR2503, KNR2504, KNR2521, and KNR2525 had infundibuliform, and the other strains had plane pileus. Several strains were valuable for breeding, JNR2503 for growth rate, KNR2512 for pileus color, and KNR2312, KNR2322, KNR2503, and KNR2513 for the quality.

The Effect of a Tibial Remnant Preservation Technique on the Synovialization of the Graft Tendon in Anterior Cruciate Ligament Reconstruction - Based on the Second Look Arthroscopic Findings - (전방십자인대 재건술시 잔류 조직 보존술이 이식 인대의 활막화(synovialization)에 미치는 영향 - 2차 관절경 소견을 중심으로 -)

  • Ahn, Gil Yeong;Nam, Il Hyun;Moon, Gi Hyuk;Lee, Yeong Hyun;Choi, Seong Pil;Yoo, Jong Yeon
    • Journal of the Korean Arthroscopy Society
    • /
    • 제17권1호
    • /
    • pp.11-17
    • /
    • 2013
  • Purpose: The purpose of this study is to evaluate the effect of preservation of the tibial remnant on the synovialization of graft tendon after the reconstruction of anterior cruciate ligament (ACL) based on the second look arthroscopic findings. Materials and Methods: From May 2005 to May 2012, among sixty three patients having ACL reconstruction with the four-strand hamstring using a bioabsorbable cross pin (RigidFix$^{(R)}$) for the femoral tunnel, nineteen patients who had second look arthroscopy were analyzed. We classified them into three groups according to the tibial remnant of the torn ACL for arthroscopic findings. Group 1 had less than 5 mm of a remnant tissue, Group 2 had from 6 mm to 10 mm of it, and Group 3 had more than 11 mm. We estimated the percentage of synovial coverage on the graft tendon during second look arthroscopy. We evaluated Lysholm score and Tegner activity score preoperatively and in the last follow-up. Results: At the time of ACL reconstruction, the mean length of preserved tibial remnant of torn ACL was 2.3 mm in Group 1, 7.4 mm in Group 2, and 13.7 mm in Group 3. In the second look arthroscopy, the average percentage of synovial coverage was 55.4% in Group 1, and 77.9% in Group 2, and 89.7% in Group 3. Lysholm score and Tegner activity score improved from 74.2 and 7.3 preoperatively to 94.1 and 8.5 in the last follow-up. Conclusion: The preservation of tibial remnant of torn ACL influenced the synovial coverage of the graft tendon and the volume of preserved remnant in accordance with the surface of synovial coverage. It would have a good effect on graft healing and preservation of proprioceptive function.

  • PDF

Limited Open Reduction and Internal Fixation of the Tibial Pilon Fractures (제한 절개를 통한 관혈적 정복 및 내고정술을 이용한 경골 Pilon 골절의 치료)

  • Kang, Chung-Nam;Kim, Jong-Oh;Kim, Dong-Wook;Koh, Young-Do;Ko, Sang-Hun;Yoo, Jae-Doo;Hwang, Jun-Ho
    • Journal of Korean Foot and Ankle Society
    • /
    • 제1권2호
    • /
    • pp.102-111
    • /
    • 1997
  • The tibial Pilon fracture, which is defined as a comminuted intraarticular fracture of the distal tibia, is difficult to manage because high axial compression and rotational forces to the ankle joint result in impaction, severe comminution, metaphyseal disruption and soft tissue damage. There are variable methods of treatment such as manipulation and cast, calcaneal traction and cast, external fixation, pin and plaster, limited open reduction and external fixation, and open reduction and rigid internal fixation. Though most of authors reported better result after a surgical treatment. than that of conservative treatment, many complications such as posttraumatic arthritis and soft tissue problem still remain troublesome. We have reviewed 19 cases of the tibial Pilon fractures in 18 patients which were treated with limited open reduction and internal fixation from September 1993 to May 1996. The results were as follows: 1. The fractures were classified into five types according to the system of Ovadia and Beals, and the most frequent type was type 3 (53%). The most common cause of injury was traffic accident (47%). 2. All of the cases of type 1 and 2, in which the injury of the ankle joint was less severe, revealed good or excellent clinical results. But in type 4 and 5, because the injury is much severe and accurate reduction is difficult, the clinical results were unsatisfaetory. 3. The most frequent complication was posttraumatic osteoarthritis, and which developed in second frequent complication, was developed m the three cases of type 3 in which the radiographic results were less than fair, but there were no correlation with the clinical results. 4. We could markedly reduce the complications related to the soft tissue problem of Pilon fracture by treatment with limited open reduction and internal fixation, and consider that this is a good method of treatment of Pilon fracture when the injury is less severe and accurate reduction is possible.

  • PDF

Observation of Response to PPD Skin Test and Local Side Reactions at Multiple Inoculation Sites after Percutanous Inoculation with BCG Tokyo 172 Strain (경피용 건조 B.C.G. 백신(Tokyo 172주) 접종 후 국소 반응과 투베르쿨린 양전율에 관한 연구)

  • Lee, Jin Soo;Sohn, Young Mo
    • Pediatric Infection and Vaccine
    • /
    • 제7권2호
    • /
    • pp.201-210
    • /
    • 2000
  • Purpose : We observed response to PPD skin test and local side reactions among subjects who received inoculation with Tokyo 172 BCG strain by percutaneous method using multiple puncture device. Methods : 138 infants and young children were enrolled at Yongdong Severance Hospital and 7 private clinics. 5TU PPD skin test were performed at 4 months after inoculation. The local reactions at multiple puncture site were observed in 3 days, 4~6 weeks, 36 weeks, and 48 weeks after inoculations and physical check up was done for evaluation of lymphadenopathy. Results : During 48 weeks of observation period, 96 subjects among 138 who were enrolled were followed up completely with records of PPD skin test and observation of local side reactions, presenting with the photos. The size of the induration after 48 hours of PPD skin test, was less than 5mm in six subjects(6.3%), greater than 10mm in sixty seven subjects(70.0%) and greater than 12mm in forty six subjects(47.9%). All subjects showed inflammatory reaction and pustules at multiple puncture sites and only just small papules, ulcer and pustules remained 4-6 weeks later. Eight to twelve weeks later, all local inflammatory skin reactions disappeared with remaining crust. After 48 weeks, 4(4.2%) subjects showed no scar with only faint stain on the puncture site. More than 70% of subjects showed more than 10 faint pin-point scars on the sites. However, the size of scar was clearly smaller compared to that of intradermal inoculation. There were no cases of lymphadenopathy. Conclusion : We observed good immune response to 5TU PPD skin test among the infant and young children who were immunized with percutanous inoculation of Tokyo 172 BCG strain. We could not find any severe local scar at inoculation sites. A degree of satisfaction of the parents whose children received the percutaneous injection was very high.

  • PDF

Performance Estimation of Large-scale High-sensitive Compton Camera for Pyroprocessing Facility Monitoring (파이로 공정 모니터링용 대면적 고효율 콤프턴 카메라 성능 예측)

  • Kim, Young-Su;Park, Jin Hyung;Cho, Hwa Youn;Kim, Jae Hyeon;Kwon, Heungrok;Seo, Hee;Park, Se-Hwan;Kim, Chan Hyeong
    • Journal of Radiation Protection and Research
    • /
    • 제40권1호
    • /
    • pp.1-9
    • /
    • 2015
  • Compton cameras overcome several limitations of conventional mechanical collimation based gamma imaging devices, such as pin-hole imaging devices, due to its electronic collimation based on coincidence logic. Especially large-scale Compton camera has wide field of view and high imaging sensitivity. Those merits suggest that a large-scale Compton camera might be applicable to monitoring nuclear materials in large facilities without necessity of portability. To that end, our research group have made an effort to design a large-scale Compton camera for safeguard application. Energy resolution or position resolution of large-area detectors vary with configuration style of the detectors. Those performances directly affect the image quality of the large-scale Compton camera. In the present study, a series of Geant4 Monte Carlo simulations were performed in order to examine the effect of those detector parameters. Performance of the designed large-scale Compton camera was also estimated for various monitoring condition with realistic modeling. The conclusion of the present study indicates that the energy resolution of the component detector is the limiting factor of imaging resolution rather than the position resolution. Also, the designed large-scale Compton camera provides the 16.3 cm image resolution in full width at half maximum (angular resolution: $9.26^{\circ}$) for the depleted uranium source considered in this study located at the 1 m from the system when the component detectors have 10% energy resolution and 7 mm position resolution.

Feasibility Study of the microDiamond Detector for Measurement of Small Field Photon Beam (광자선 소조사면 선량측정을 위한 microDiamond 검출기의 유용성 고찰)

  • Lee, Chang Yeol;Kim, Woo Chul;Kim, Hun Jeong;Ji, Young Hoon;Kim, Kum Bae;Lee, Sang Hoon;Min, Chul Kee;Jo, Gwang Hwan;Shin, Dong Oh;Kim, Seong Hoon;Huh, Hyun Do
    • Progress in Medical Physics
    • /
    • 제25권4호
    • /
    • pp.255-263
    • /
    • 2014
  • The dosimetry of very small fields is challenging for several reasons including a lack of lateral electronic equilibrium, large dose gradients, and the size of detector in respect to the field size. The objective of this work was to evaluate the suitability of a new commercial synthetic diamond detector, namely, the PTW 60019 microDiamond, for the small field dosimetry in cyberknife photon beams of 6 different collimator size (from 5 mm to 30 mm). Measurements included dose linearity, dose rate dependence, output factors (OF), percentage depth doses (PDD) and off center ratio (OCR). The results were compared to those of pinpoint ionization chamber, diamond detector, microLion liquid Ionization chamber and diode detector. The dose linearity results for the microDiamond detector showed good linearly proportional to dose. The microDiamond detector showed little dose rate dependency throughout the range of 100~600 MU/min, while microLion liquid Ionization chamber showed a significant discrepancy of approximately 5.8%. The OF measured with microDiamond detector agreed within 3.8% with those measured with diode. PDD curves measured with silicon diode and diamond detector agreed well for all the field sizes. In particular, slightly sharper penumbras are obtained by the microDiamond detector, indicating a good spatial resolution. The results obtained confirm that the new PTW 60019 microDiamond detector is suitable candidate for application in small radiation fields dosimetry.

Slipped Capital Femoral Epiphysis(SCFE) (대퇴골두 골단분리증의 치험례)

  • Dan, Jin-Myoung;Kim, Se-Dong
    • Journal of Yeungnam Medical Science
    • /
    • 제14권1호
    • /
    • pp.245-261
    • /
    • 1997
  • Slipped capital femoral epiphysis(SCFE) is a disorder in which there is a gradual or acute disruption through the capital physeal plate. The physiolysis is through a widened zone of hypertrophy, which is weakened due to altered chondrocytic maturation and endochondral ossification. The cause or causes of SCFE remain uncertain. The association of obesity and adolescent age with growth rate are predisposing factors. The possibility that most patients with subclinical hormonal abnormality were proved. The goal of treatment of slipped capital femoral epiphysis is to restore the function of the hip and delay the development of degenerative osteoarthrosis by prevention of additional displacement of the epiphysis. We report 10 patients(12hips) with SCFE who were treated by surgical means and followed along for more than one year, at Yeungnam University Hospital, from 1989 to 1996. There were six boys and four girls. The average age at operation was 11.8 years. Seven cases occurred in the left hip, one case in the right and 2 cases had bilateral involvement, five cases had a history of minor trauma on affected hip. Among hormonally studied six patients, panhypopituitarism patient was one case; decreased testosterone, two; decreased growth hormone, two; and decreased thyroid hormone, one. According to clinical stage, two cases were the acute type; five cases, acute on chronic type; and three cases, chronic type. On the radiological grades of slipping, mild slippage were nine hips; moderate, one; and severe, two. The eleven hips were treated by pin fixation in situ, and one, by cuneiform osteotomy. On the average follow-up of 2.6 years, ten hips were excellent or good functional results, two hips were failure.

  • PDF

The Clinical Examination of Netspeg Lens for Good Visual Acuity (시력 개선을 위한 Netspeg 렌즈의 임상적 검증)

  • Kim, Douk-Hoon;Bae, Han-Young;Kim, Sun-Tae
    • Journal of Korean Ophthalmic Optics Society
    • /
    • 제11권3호
    • /
    • pp.281-291
    • /
    • 2006
  • The aim of this study was performed the clinical test using Netspeg lens for good visual acuity on subjects with abnormal refraction status. The subjects of one hundreds adults (fifty males, fifty females, mean=21 years, range=19 to 24) were recorded. The subjects were researched the history including the systemic health, medication, genetics, allergy, systemic disease and ocular disease. The refraction test was recorded the monocular and binocular using objective method. Visual acuity was performed the binocular status using the Netspeg lens and CR-39. Stereopsis test was performed the titmus fly and TNO at near distance using Netspeg lens and CR-39. The P-VEP test was used the 16 pattern size(Bausch Lomb, production in USA) with three channels. Also Subjects viewed the p-vep stimulus with binocular vision through the corrected visual acuity using the Netspeg lens and CR-39. The contrast sensitivity test was performed the contrast sensitivity chart(pelli-Robertson, USA) at 1m distance using the Netspeg lens and CR-39. The ultrastructure of surface on the Netspeg lens and CR-39 was observed the SEM(JMS-5800, made in Japan). The results of this study was as follows: 1. In corrected visual acuity of abnormal refraction using the Netspeg lens and CR-39, the Netspeg lens wearer were acquired the good visual field and clear visual acuity comparative to CR-39 wearer in the subject vision test. however the comfort of visual acuity was similar results in the Netspeg lens and CR-39. Also the subjects of Netspeg lens wearer was good visual acuity more than CR-39 wearer and in the analysis of P-VEP, the amplitude of wave on Netspeg lens used appears to be better through the CR-39(p>0.5). Besides, on the contrast sensitivity, the Netspeg lens wearer was good results than CR-39. The value on stereopsis with TNO by Netspeg lens wearer was better than CR-39 in results. However, in the stereopsis test with Titmus, the Netspeg lens and CR-39 wearer was similar results. 2. The ultrastructure of Netspeg lens surface was the smooth and fine shape more than CR-39. Also, Netspeg lens have a fine line structure in ultrastructure. In conclusion, the results of this study conformed that the surface ultrastructure of Netspeg lens used is more specific pin hole design structure than CR-39. This study indicated that the vision of Netspeg lens used have a better than CR-39 in the corrected visual acuity for abnormal refraction eye. Therefore, In this paper, we suggested that the ultrastructure and line structure of Netspeg lens was related to good visual function. However the visual function of the aspheric Netspeg and ultra waterproof Netspeg lens was similar results.

  • PDF