• Title/Summary/Keyword: Pin to pin

Search Result 2,304, Processing Time 0.028 seconds

An Experimental Study on Flexural Behavior of RC Beams Strengthened with Hi-Strength Bars(2) (고장력 인장봉으로 보강된 RC보의 휨거동에 관한 실험적 연구(2))

  • Shin, Kyung-Jae;Kwak, Myong-Keun;Bae, Kyu-Woong;Oh, Young-Suk;Moon, Jung-Ho
    • Journal of the Korea Concrete Institute
    • /
    • v.18 no.5 s.95
    • /
    • pp.603-610
    • /
    • 2006
  • The external unbonded strengthening offers advantages in speed and simplicity of installation over other strengthening techniques. Unlike externally bonded steel plate or carbon fiber sheet, surface preparation of the concrete for installation of high-tension bar is not required and installation is not affected by environmental conditions. Anchoring pin or anchoring plate are installed at the end of beam to connect the high-tension bar to concrete beam. The deviator are used in order that supplementary external bars would follow the curvature of the tested beam. A set often laboratory tests on reinforced concrete beam strengthened using the technique are reported. The main test parameters are the section area of strengthening bar, the depth of deviator and the number of deviators. The paper provides a general description of structural behavior of beams strengthened using the technique. The test result of strengthened beam are compared with those from a reference specimen. It is shown that the reinforcing technique can provide greater strength enhancements to unstrengthened beam and that the provision of deviator enhances efficiency. The ultimate moment of specimen with two deviators was higher than that of specimens with one deviator. It is also shown that the external bars enhance strength of beams in shear.

Improvement of Phase Noise for Oscillator Using Frequency Locked Loop (주파수 잠금회로를 이용한 발진기의 위상잡음 개선)

  • Kim, Wook-Lae;Lee, Chang-Dae;Kim, Yong-Nam;Im, Pyung-Soon;Lee, Dong-Hyun;Yeom, Kyung-Whan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.7
    • /
    • pp.635-645
    • /
    • 2016
  • In this paper, we showed the phase noise of voltage controlled oscillator(VCO) can be radically improved using FLL(Frequency Locked Loop). At first, a 5 GHz VCO is fabricated using a hair-pin resonator. The fabricated VCO shows a phase noise of -53.1 dBc/Hz at 1 kHz frequency offset. In order to improve the phase noise of the fabricated VCO, a FLL is constructed using the feedback loop that consists of the VCO, a frequency detector composed of 5 GHz resonator, loop-filter, and level shifter. The fabricated FLL is designed to oscillate at a frequency of 5 GHz, and its measured phase noise is about -120.6 dBc/Hz at 1 kHz offset frequency. As a result, the phase noise of VCO can be radically improved by about 67.5 dB applying FLL. In addition, the measured phase noise performance is close to that of crystal oscillator.

A Study on Fracture Behavior of Center Crack at Unidirectional CFRP due to Stacking Angle (적층각도에 따른 단방향 CFRP에서의 중앙 크랙의 파괴 거동에 관한 연구)

  • Park, Jae-Woong;Cheon, Seong-Sik;Cho, Jae-Ung
    • Composites Research
    • /
    • v.29 no.6
    • /
    • pp.342-346
    • /
    • 2016
  • Carbon fiber reinforced plastic (CFRP), one of lightweight materials, is the fiber structure using carbon fiber. It is the composite material that has the characteristics of carbon and plastic. As for the fiber structure, it has the great strength due to fiber direction. CFRP for woven type is used mostly as such a CFRP with lightweight. Woven type is more stable when compared with unidirectional type. On the other hand, woven type is highly priced. Therefore, this study aims to analyze the fiber structure of unidirectional CFRP. In this study, as the stacking angle [0/X/-X/0], X is the variable. This is unidirectional CFRP in which the angle phase of X has been reversed and stacked. By using such a unidirectional CFRP, the analysis model which had a crack at the center as the form of panel with the thickness of 2 mm was used. On analysis, the load is applied on the upper and lower parts being connected with a pin. The damage in the area near center crack was investigated. As for the analysis model, 3D surface model was designed by using CATIA. For CFRP stacking, the stacking direction was determined by using ACP in ANSYS program and the analysis model with two stacks was made. Afterwards, the structural analysis was carried out.

A Study of Failure Mechanism through abnormal AlXOY Layer after pressure Cooker Test for DRAM device (DRAM 소자의 PCT 신뢰성 측정 후 비정상 AlXOY 층 형성에 의해 발생된 불량 연구)

  • Choi, Deuk-Sung;Jeong, Seung-Hyun;Choi, Chae-Hyoung
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.25 no.3
    • /
    • pp.31-36
    • /
    • 2018
  • This research scrutinizes the reason of failure after pressure cooker test (PCT) for DRAM device. We use the physical inspecting tools, such as microscope, SEM and TEM, and finally find the discolor phenomenon, corrosion of Al and delamination of inter-metal dielectric (IMD) in the failed devices after PCT. Furthermore, we discover the abnormal $Al_XO_Y$ layer on Al through the careful additional measurements. To find the reason, we evaluate the effect of package ball size and pinhole in passivation layer. Unfortunately, those aren't related to the problems. We also estimate halide effect of Al. The halogens such like Cl are contained within EMC material. Those result in the slight improving of PCT characteristics but do not perfectly solve the problems. We make a hypothesis of Galvanic corrosion. We can find the residue of Ti at the edge of pad open area. We can see the improving the PCT characteristics by the time split of repair etch. The possible mechanism of the PCT failure can be deduced as such following sequence of reactions. The remained Ti reacts on the pad Al by Galvanic corrosion. The ionized Al is easily react with the $H_2O$ supplied under PCT environment, and finally transfers to the abnormal $Al_XO_Y$ layer.

Treatment of Open Proximal Humerus Fracture by Gunshot (총격에 의한 개방성 근위 상완골 골절의 치료 - 증례 보고 -)

  • Kim, Sung-Jae;Lee, Jae-Hoo;Chun, Yong-Min
    • Clinics in Shoulder and Elbow
    • /
    • v.15 no.1
    • /
    • pp.37-42
    • /
    • 2012
  • Purpose: To consider the proper management of proximal humerus fracture on gunshot wounds. Materials and Methods: A 28-year-old male patient, who sustained a gunshot injury on the left arm 5 days ago, was admitted through the emergency department. Although he underwent an emergency surgery (bullet fragment removal and debridement), there remained bullet fragments around the proximal humerus fracture site. The wound seemed to be infected and a partial dehiscence occurred. No neurologic deficit was noted. Immediate exploration and debridement were performed, and an external fixator was applied to restore the anatomical alignment and manage the wounds. Intravenous antibiotics were administered. On the 9th postoperative day, wound debridement was done again, and cement beads mixed with antibiotics were inserted. After two weeks, the external fixator was removed, and the pin sites were closed after debridement. One week later, the open reduction and internal fixation with locking compression plate and screws were done. Result: At 3 months after the internal fixation, the bone union was obtained with satisfactory alignment of the humerus. Conclusion: The severity of the soft tissue injury influences the fracture management plan. Further, the risk on lead toxicity should be considered.

Implementation of the Digital Current Control System for an Induction Motor Using FPGA (FPGA를 이용한 유도 전동기의 디지털 전류 제어 시스템 구현)

  • Yang, Oh
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.35C no.11
    • /
    • pp.21-30
    • /
    • 1998
  • In this paper, a digital current control system using a FPGA(Field Programmable Gate Array) was implemented, and the system was applied to an induction motor widely used as an industrial driving machine. The FPGA designed by VHDL(VHSIC Hardware Description Language) consists of a PWM(Pulse Width Modulation) generation block, a PWM protection block, a speed measuring block, a watch dog timer block, an interrupt control block, a decoder logic block, a wait control block and digital input and output blocks respectively. Dedicated clock inputs on the FPGA were used for high-speed execution, and an up-down counter and a latch block were designed in parallel, in order that the triangle wave could be operated at 40 MHz clock. When triangle wave is compared with many registers respectively, gate delay occurs from excessive fan-outs. To reduce the delay, two triangle wave registers were implemented in parallel. Amplitude and frequency of the triangle wave, and dead time of PWM could be changed by software. This FPGA was synthesized by pASIC 2SpDE and Synplify-Lite synthesis tool of Quick Logic company. The final simulation for worst cases was successfully performed under a Verilog HDL simulation environment. And the FPGA programmed for an 84 pin PLCC package was applied to digital current control system for 3-phase induction motor. The digital current control system of the 3 phase induction motor was configured using the DSP(TMS320C31-40 MHz), FPGA, A/D converter and Hall CT etc., and experimental results showed the effectiveness of the digital current control system.

  • PDF

Evaluation of Anastomotic Strength and in-vitro Degradability with Microvascular Anastomosis Coupler Based on Injection Molding Condition made by Biodegradable Polycaprolactone(PCL) (생체분해성 폴리카프로락톤(PCL) 미세혈관 문합커플러의 사출성형조건에 따른 문합강도 및 in-vitro 분해능 평가)

  • Ahn, Geun-Seon;Han, Gig-Bong;Oh, Seung-Hyun;Park, Jong-Woong;Kim, Cheol-Woong
    • Transactions of the KSME C: Technology and Education
    • /
    • v.1 no.2
    • /
    • pp.167-177
    • /
    • 2013
  • The use of mechanical anastomosis coupler instead of sutures has been increasing in microvascular anastomosis surgery. However, non-biodegradable anastomosis coupler has problems such as not only inflammatory reaction but also remaining permanently in operation wound. Therefore, we fabricated biodegradable anastomosis coupler using injection molding process to overcome the limitation of non-biodegradable anastomosis coupler. In various injection molding process conditions, the shrinkage was calculated with different cylinder temperatures and injection molding pressures and anastomotic strength was measured. As a result, changes in shrinkage hole part larger than the pin part. In addition, the shrinkage in the cylinder at higher temperatures increase. However, the higher the injection pressure, shrinkage tends to decrease, respectively. In-vitro degradation behavior of PCL anastomotic coupler evaluated for 12 weeks, water uptake was increased and molecular weight was accompanied by a reduction in mass of the biological degradation and reduction of anastomotic strength was confirmed. However, decreased levels of anastomotic strength enough to exceed the requirements of preclinical surgery, PCL microvascular anastomosis coupler suitable candidate materials that could identify.

Digestibility, ruminal fermentation, and nitrogen balance with various feeding levels of oil palm fronds treated with Lentinus sajor-caju in goats

  • Hamchara, Puwadon;Chanjula, Pin;Cherdthong, Anusorn;Wanapat, Metha
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.31 no.10
    • /
    • pp.1619-1626
    • /
    • 2018
  • Objective: This study was an attempt to investigate the effect of levels of fungal (Lentinus sajor-caju) treated oil palm fronds (FTOPF) on digestibility, rumen fermentation, and nitrogen balance in goats. Methods: Four 16 month old male crossbred (Thai Native${\times}$Anglo Nubian) goats with initial body weights of $33.5{\pm}1.7kg$ were randomly assigned according to a $4{\times}4$ Latin square design. Four levels of FTOPF were assigned for feed intake. The experimental treatments consisted of 0%, 33%, 67%, and 100% of oil palm fronds (OPF) being replaced by FTOPF. Results: The results revealed that total dry matter intake and nutrient intake were not influenced (p>0.05) by the inclusion of FTOPF. However, the efficiency values of the digestibility of the dry matter, organic matter, crude protein, neutral detergent fiber, acid detergent fiber, and acid detergent lignin on FTOPF were higher (p<0.05) in treatments with 33%, 67%, and 100% of FTOPF compared with 0% of FTOPF. FTOPF feeding did not change the rumen pH, temperature, and $NH_3-N$. However, the FTOPF levels did affect the total volatile fatty acid (VFA), molar proportion of acetate, propionate, butyrate, ratio of acetic (propionic acid and acetic) plus butyric (propionic acid), and production of $CH_4$. The totals of VFA and propionate was lower in goat fed with 0% of FTOPF than in those of the other groups (p<0.05). The amount of nitrogen retention based on g/d/animal or the percentage of nitrogen retained was the lowest the goat fed with 0% of FTOPF (p<0.05), whereas nitrogen intake, excretion, and absorption were not changed among treatments. Conclusion: Based on this study, FTOPF could be effectively used as an alternative roughage source in total mixed ration diets, constituting at least up to 100% of OPF.

Association of PINX1 but not TEP1 Polymorphisms with Progression to Hepatocellular Carcinoma in Thai Patients with Chronic Hepatitis B Virus Infection

  • Sriprapun, Methee;Chuaypen, Natthaya;Khlaiphuengsin, Apichaya;Pinjaroen, Nutcha;Payungporn, Sunchai;Tangkijvanich, Pisit
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.4
    • /
    • pp.2019-2025
    • /
    • 2016
  • Hepatocellular carcinoma (HCC) is major health problem with high mortality rates, especially in patients with hepatitis B virus (HBV) infection. Telomerase function is one of common mechanisms affecting genome stability and cancer development. Recent studies demonstrated that genetic polymorphisms of telomerase associated genes such as telomerase associated protein 1 (TEP1) rs1713449 and PIN2/TERF1-interacting telomerase inhibitor 1 (PINX1) rs1469557 may be associated with risk of HCC and other cancers. In this study, 325 patients with HCC and 539 non-HCC groups [193 healthy controls, 80 patients with HBV-related liver cirrhosis (LC) and 266 patients with HBV-related chronic hepatitis (CH)] were enrolled to explore genetic polymorphisms of both SNPs using the allelic discrimination method based on MGB probe TaqMan real time PCR. We demonstrated that all genotypes of both genes were in Hardy-Wienberg equilibrium (P>0.05). Moreover, there was no significant association between rs1713449 genotypes and HCC risk, HCC progression and overall survival (P>0.05). Interestingly, we observed positive association of rs1469557 with risk of HCC when compared with the LC group under dominant (CC versus CT+TT, OR=1.89, 95% CI= 1.06-3.40, P=0.031) and allelic (C versus T alleles, OR=1.75, 95% CI=1.04-2.94, P=0.033) models, respectively. Moreover, overall survival of HCC patients with CC genotype of rs1469557 was significantly higher than non-CC genotype (Log-rank P=0.015). These findings suggest that PINX1 rs1469557 but not TEP1 rs1469557 might play a role in HCC progression in Thai patients with LC and be used as the prognosis marker to predict overall survival in HCC patients.

Tibiotalocalcaneal Arthrodesis Using Ipsilateral Distal Fibula Buttress (동측 원위 비골 지주를 이용한 경-거-종골 관절 유합술)

  • Cho, Se-Hyun;Lee, Jung-Su;Jeong, Seon-Taek;Park, Hyung-Bin;Hwang, Sun-Chul;Jeong, Jae-Hyon;Cha, Min-Suok
    • Journal of Korean Foot and Ankle Society
    • /
    • v.10 no.2
    • /
    • pp.213-217
    • /
    • 2006
  • Purpose: To evaluate the clinical and radiological results of tibio-talo-calcaneal arthrodesis using ipsilateral distal fibula buttress which had advantages of extended operative field and release of contracted soft tissue. Materials and Methods: We retrospectively reviewed 4 postraumatic compartment syndrome, 2 residual poliomyelitis, 1 posttraumatic osteoarthritis with subtalar joint infection and 1 posttarumatic sciatic nerve palsy patients who underwent a tibio-talo-calcaneal arthrodesis from April, 1996 to March, 2002. Each of the cases was notable for a severe rigid equinovarus, persistent pus drainage of calcaneal area and paralytic foot. The mean duration of follow up was 18 months (range, $13{\sim}42$ months). The pain, function and alignment were evaluated by the modified ankle hindfoot scale of the American Orthopaedic Foot and Ankle Society (AOFAS) and patients satisfaction clinically. The radiological union were evaluated by plain AP and lateral radiographs. Results: The AOFAS score improved from 58 points (range, $47{\sim}78$) preoperatively to 82 (range, $60{\sim}89$) postoperatively. Patents satisfaction checked at 12 months after operation had favorable results (excellent and good 80%). Union rate was 100% radiographically and the mean duration of union was 12.5 weeks (range $8{\sim}22$ weeks). There was 2 cases of superficial pin tract infection and one protrusion of screw. Conclusion: Tibio-talo-calcaneal arthrodesis using ipsilateral distal fibula buttress was good modality of arthrodesis which provides wide operative field and release of contracted soft tissue in some cases of contracted foot.

  • PDF