• Title/Summary/Keyword: Pin Method

Search Result 682, Processing Time 0.031 seconds

Comparative evaluation of photobiomodulation therapy at 660 and 810 nm wavelengths on the soft tissue local anesthesia reversal in pediatric dentistry: an in-vivo study

  • Ankita Annu;Sujatha Paranna;Anil T. Patil;Sandhyarani B.;Adhithi Prakash;Renuka Rajesh Bhurke
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.23 no.4
    • /
    • pp.229-236
    • /
    • 2023
  • Background: Local anesthesia has been reliably used to control pain during dental procedures and is important in pediatric dentistry. However, children occasionally complain of prolonged numbness after dental treatment, leading to several problems. Studies conducted to reverse the effect of local anesthesia using phentolamine mesylate and photobiomodulation therapy (PBM) are encouraging but limited. PBM is a type of light therapy that utilizes visible and near-infrared non-ionizing electromagnetic spectral light sources. Hence, this study used this modality to compare the reversal of local anesthesia at two different wavelengths. This study compared the effect of PBM at 660 and 810 nm wavelengths on the reversal of soft tissue local anesthesia using a diode LASER in pediatric dentistry. Method: Informed consent and assent were obtained, and the participants were then divided randomly into three groups of 20 children each: control group-without LASER irradiation, LASER irradiation at 660 nm, and LASER irradiation at 810 nm. Sixty children aged 4-8 years with deciduous mandibular molars indicated for pulp therapy were administered an inferior alveolar nerve block. After 45 min of injection, a duration that was similar to the approximate duration of treatment, they were exposed to 660- and 810-nm LASER irradiation according to their groups until reversal of local anesthesia was achieved. The control group did not undergo LASER irradiation. The reversal of the soft tissue local anesthetic effect was evaluated using palpation and pin prick tests every 15 min, and the LASER irradiation cycle continued until reversal of the soft tissue local anesthesia was achieved. Results: A significant reduction of 55.5 min (27.6%) in the mean soft tissue local anesthesia reversal time was observed after the application of 810 nm wavelength PBM and 69 min (34.7%) after 660 nm wavelength LASER irradiation. Conclusion: PBM with a 660 nm wavelength was more effective in reducing the mean soft tissue local anesthesia reversal duration, and thus can be used as a reversal agent for soft tissue local anesthesia in pediatric dentistry.

The Clinical Examination of Netspeg Lens for Good Visual Acuity (시력 개선을 위한 Netspeg 렌즈의 임상적 검증)

  • Kim, Douk-Hoon;Bae, Han-Young;Kim, Sun-Tae
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.11 no.3
    • /
    • pp.281-291
    • /
    • 2006
  • The aim of this study was performed the clinical test using Netspeg lens for good visual acuity on subjects with abnormal refraction status. The subjects of one hundreds adults (fifty males, fifty females, mean=21 years, range=19 to 24) were recorded. The subjects were researched the history including the systemic health, medication, genetics, allergy, systemic disease and ocular disease. The refraction test was recorded the monocular and binocular using objective method. Visual acuity was performed the binocular status using the Netspeg lens and CR-39. Stereopsis test was performed the titmus fly and TNO at near distance using Netspeg lens and CR-39. The P-VEP test was used the 16 pattern size(Bausch Lomb, production in USA) with three channels. Also Subjects viewed the p-vep stimulus with binocular vision through the corrected visual acuity using the Netspeg lens and CR-39. The contrast sensitivity test was performed the contrast sensitivity chart(pelli-Robertson, USA) at 1m distance using the Netspeg lens and CR-39. The ultrastructure of surface on the Netspeg lens and CR-39 was observed the SEM(JMS-5800, made in Japan). The results of this study was as follows: 1. In corrected visual acuity of abnormal refraction using the Netspeg lens and CR-39, the Netspeg lens wearer were acquired the good visual field and clear visual acuity comparative to CR-39 wearer in the subject vision test. however the comfort of visual acuity was similar results in the Netspeg lens and CR-39. Also the subjects of Netspeg lens wearer was good visual acuity more than CR-39 wearer and in the analysis of P-VEP, the amplitude of wave on Netspeg lens used appears to be better through the CR-39(p>0.5). Besides, on the contrast sensitivity, the Netspeg lens wearer was good results than CR-39. The value on stereopsis with TNO by Netspeg lens wearer was better than CR-39 in results. However, in the stereopsis test with Titmus, the Netspeg lens and CR-39 wearer was similar results. 2. The ultrastructure of Netspeg lens surface was the smooth and fine shape more than CR-39. Also, Netspeg lens have a fine line structure in ultrastructure. In conclusion, the results of this study conformed that the surface ultrastructure of Netspeg lens used is more specific pin hole design structure than CR-39. This study indicated that the vision of Netspeg lens used have a better than CR-39 in the corrected visual acuity for abnormal refraction eye. Therefore, In this paper, we suggested that the ultrastructure and line structure of Netspeg lens was related to good visual function. However the visual function of the aspheric Netspeg and ultra waterproof Netspeg lens was similar results.

  • PDF

Temporary Use of External Fixators for Soft Tissue Lengthening in the Treatment of Complications after Limb Salvage Surgery (사지 구제술 합병증 치료에서 연부조직 연장을 위한 한시적 외고정 기기의 유용성)

  • Yoon, Pil-Whan;Kang, Hyun-Guy;Kim, Kap-Jung;Oh, Joo-Han;Lee, Sang-Hoon;Lee, Sang-Ki;Kim, Han-Soo
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.11 no.2
    • /
    • pp.134-140
    • /
    • 2005
  • Purpose: We evaluated the effectiveness of temporary using the extendible external fixator (EF) for lengthening of soft tissue that contracture caused by tumor prosthesis removal in the treatment of complications after limb salvage surgery like deep infection and loosening. Materials and Methods: Five patients six cases were included who underwent extendible EF (Dyna-extor(r)). EF was applied after insertion of half pin to the proximal and distal bone of defect area. EF lengthening started at third day of post-operation, above 2-3 mm per day in the range of no neurological sign. Results: The treatment area was three in femur and two in tibia. Mean age when the time of EF apply was 22.2 years old (range 15-29), but its primary limb salvage operation had done in 13.4 years old (range 9-19), therefore mean times of interval between initial tumor prosthesis reconstruction and temporary EF apply was 8.8 years (range 3-14). One patient had EF for 150 days with 7.2 cm lengthening. Others 5 cases of 4 patients had EF for mean 37 days (range 25-50) and mean soft tissue lengthening was 5.8 cm. Three patients underwent re-insertion of tumor prosthesis and two patients underwent knee fusion as final operation and showed no evidence of infection through mean 22 months follow up period. Conclusion: Temporary using of extendible EF is an effective method for correction of leg shortening which occurred by soft tissue contracture in the complications of limb salvage operation or their treatment process, and it could be provide easily application of tumor prosthesis and knee fusion as final operation.

  • PDF

Removable implant-supported partial denture using milled bar with Locator® attachments in a cleft lip & palate patient: A clinical report (구순구개열 환자에서 Locator® 유지장치가 장착된 milled titanium bar를 이용한 가철성 임플란트 피개 국소의치의 보철수복증례)

  • Yang, Sang-Hyun;Kim, Kyoung-A;Kim, Ja-Yeong;Seo, Jae-Min
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.3
    • /
    • pp.207-214
    • /
    • 2015
  • Due to the limitations of conventional removable partial denture prostheses to treat a cleft lip & palate patient who shows scar tissue on upper lip, excessive absorption of the maxillary residual alveolar ridge, and class III malocclusion with narrow palate and undergrowth of the maxilla, 4 implants were placed on the maxillary edentulous region and a maxillary removable implant-supported partial denture was planned using a CAD/CAM milled titanium bar. Unlike metal or gold casting technique which has shrinkage after the molding, CAD/CAM milled titanium bar is highly-precise, economical and lightweight. In practice, however, it is very hard to obtain accurate friction-fit from the milled bar and reduction in retention can occur due to repetitive insertion and removal of the denture. Various auxiliary retention systems (e.g. $ERA^{(R)}$, $CEKA^{(R)}$, magnetics, $Locator^{(R)}$ attachment), in order to deal with these problems, can be used to obtain additional retention, cost-effectiveness and ease of replacement. Out of diverse auxiliary attachments, $Locator^{(R)}$ has characteristics that are dual retentive, minimal in vertical height and convenient of attachment replacement. Drill and tapping method is simple and the replacement of the metal female part of $Locator^{(R)}$ attachment is convenient. In this case, the $Locator^{(R)}$ attachment is connected to the milled titanium bar fabricated by CAD/CAM, using the drill and tapping technique. Afterward, screw holes were formed and 3 $Locator^{(R)}$ attachments were secured with 20 Ncm holding force for additional retention. Following this procedure, satisfactory results were obtained in terms of aesthetic facial form, masticatory function and denture retention, and I hereby report this case.

Limited Open Reduction and Internal Fixation of the Tibial Pilon Fractures (제한 절개를 통한 관혈적 정복 및 내고정술을 이용한 경골 Pilon 골절의 치료)

  • Kang, Chung-Nam;Kim, Jong-Oh;Kim, Dong-Wook;Koh, Young-Do;Ko, Sang-Hun;Yoo, Jae-Doo;Hwang, Jun-Ho
    • Journal of Korean Foot and Ankle Society
    • /
    • v.1 no.2
    • /
    • pp.102-111
    • /
    • 1997
  • The tibial Pilon fracture, which is defined as a comminuted intraarticular fracture of the distal tibia, is difficult to manage because high axial compression and rotational forces to the ankle joint result in impaction, severe comminution, metaphyseal disruption and soft tissue damage. There are variable methods of treatment such as manipulation and cast, calcaneal traction and cast, external fixation, pin and plaster, limited open reduction and external fixation, and open reduction and rigid internal fixation. Though most of authors reported better result after a surgical treatment. than that of conservative treatment, many complications such as posttraumatic arthritis and soft tissue problem still remain troublesome. We have reviewed 19 cases of the tibial Pilon fractures in 18 patients which were treated with limited open reduction and internal fixation from September 1993 to May 1996. The results were as follows: 1. The fractures were classified into five types according to the system of Ovadia and Beals, and the most frequent type was type 3 (53%). The most common cause of injury was traffic accident (47%). 2. All of the cases of type 1 and 2, in which the injury of the ankle joint was less severe, revealed good or excellent clinical results. But in type 4 and 5, because the injury is much severe and accurate reduction is difficult, the clinical results were unsatisfaetory. 3. The most frequent complication was posttraumatic osteoarthritis, and which developed in second frequent complication, was developed m the three cases of type 3 in which the radiographic results were less than fair, but there were no correlation with the clinical results. 4. We could markedly reduce the complications related to the soft tissue problem of Pilon fracture by treatment with limited open reduction and internal fixation, and consider that this is a good method of treatment of Pilon fracture when the injury is less severe and accurate reduction is possible.

  • PDF

Observation of Response to PPD Skin Test and Local Side Reactions at Multiple Inoculation Sites after Percutanous Inoculation with BCG Tokyo 172 Strain (경피용 건조 B.C.G. 백신(Tokyo 172주) 접종 후 국소 반응과 투베르쿨린 양전율에 관한 연구)

  • Lee, Jin Soo;Sohn, Young Mo
    • Pediatric Infection and Vaccine
    • /
    • v.7 no.2
    • /
    • pp.201-210
    • /
    • 2000
  • Purpose : We observed response to PPD skin test and local side reactions among subjects who received inoculation with Tokyo 172 BCG strain by percutaneous method using multiple puncture device. Methods : 138 infants and young children were enrolled at Yongdong Severance Hospital and 7 private clinics. 5TU PPD skin test were performed at 4 months after inoculation. The local reactions at multiple puncture site were observed in 3 days, 4~6 weeks, 36 weeks, and 48 weeks after inoculations and physical check up was done for evaluation of lymphadenopathy. Results : During 48 weeks of observation period, 96 subjects among 138 who were enrolled were followed up completely with records of PPD skin test and observation of local side reactions, presenting with the photos. The size of the induration after 48 hours of PPD skin test, was less than 5mm in six subjects(6.3%), greater than 10mm in sixty seven subjects(70.0%) and greater than 12mm in forty six subjects(47.9%). All subjects showed inflammatory reaction and pustules at multiple puncture sites and only just small papules, ulcer and pustules remained 4-6 weeks later. Eight to twelve weeks later, all local inflammatory skin reactions disappeared with remaining crust. After 48 weeks, 4(4.2%) subjects showed no scar with only faint stain on the puncture site. More than 70% of subjects showed more than 10 faint pin-point scars on the sites. However, the size of scar was clearly smaller compared to that of intradermal inoculation. There were no cases of lymphadenopathy. Conclusion : We observed good immune response to 5TU PPD skin test among the infant and young children who were immunized with percutanous inoculation of Tokyo 172 BCG strain. We could not find any severe local scar at inoculation sites. A degree of satisfaction of the parents whose children received the percutaneous injection was very high.

  • PDF

The Anti-Sticking Effect of Mixture of Trisodium Phosphate and Citric Acid on Oral Streptococcus species (구강 내 사슬알균 종들에 대한 제3인산나트륨과 구연산의 탈부착 효과)

  • Jung, Choong-Hyun;Cho, Hyung-Hun;Choi, Gwang-Ju;Kang, Seung-Yong;Yang, Nam-Woong
    • Korean Journal of Microbiology
    • /
    • v.44 no.4
    • /
    • pp.289-292
    • /
    • 2008
  • Trisodium phosphate 12 hydrate and citric acid monohydrate mixture showed the strong anti-sticking effect on Streptococcus mutans, Streptococcus mitis, and Streptococcus salivarius, which are adhered to glass beads. Each Streptococcus species was shaking-cultured in brain heart infusion broth containing three glass beads. After 18 hr, glass beads were slightly washed into normal saline by three-pin-pointed pincette. Each three glass-beads set was put into reagent -containing tubes, which have 40 mg of bits of weighing paper for gaining brushing effect as similar as brushing one's teeth. The tubes were shaken by vortex mixer for 10 min except non-oral microbe, Streptococcus agalactiae (5 min). The samples were colony-counted by serial agar dilution method. Experiment was repeated three times for each Streptococcus species. The relative ratios of bacterial de-adherence by reagents were calculated in comparison with normal saline control. The de-adherence degree of citric acid-trisodium phosphate-saline mixture (CTS, pH 6.0) against Streptococcus mutans came to an average of 12.5 times compared with normal saline control. Trisodium-saline (TS, pH 8.4) showed the average of 7.5 times, and citric acid-saline (CS, pH 4.6) showed 6.0 times compared to the control group. The bacterial de-adherence degree against Streptococcus salivarius was each 7.2,2.6 and 2.8 times in above reagent sequence in comparison with saline control. CTS and TS showed 2.4 and 3.4 times of anti-sticking effect on Streptococcus mitis respectively, but CS had no anti-sticking effect on this bacterium. CTS, TS and CS showed 0.7, 0.6, and 0.6 times on non-oral microbe, Streptococcus agalactiae, separately compared with saline control. These results show that oral Streptococcus mutans, Streptococcus salivarius, and Streptococcus mitis, which are causative of dental caries or subacute endocarditis, may be easily removed from oral cavity by CTS mixture. It is conceivable that our experimental results will enable the development of a new conceptive toothpaste to prevent dental caries or subacute endocarditis after drawing teeth.

Foreign Body in the Gastrointestinal Tract in Children (소아의 위장관 이물질에 대한 임상적 고찰)

  • Lee, Bo-Hyeong;Lee, Hyun-Kyung;Kim, Mi-Jung;Choi, Kwang-Hae
    • Journal of Yeungnam Medical Science
    • /
    • v.18 no.1
    • /
    • pp.75-84
    • /
    • 2001
  • Background: The accidental swallowing of foreign body is a common problem in the children. Ingested foreign bodies may be managed by endoscopy, observation, or surgery. So we analyzed the methods of removal, type, location and complications of foreign bodies. Materials and Methods: This report reviewed 37 cases of ingested foreign body in the gastrointestinal tract at the Department of Pediatrics, Yeungnam University Hospital between January 1997 and April 2001. Results: The age ranged from 8 months to 8 years. The most prevalent age group was between 1 year and 2 years of age(19%). The male to female ratio was 2.1:1 with 25 male and 12 female patients. The type of foreign bodies were coins in 20 cases(54%), nail in 4 cases(11%), key in 4 cases(11%), pin in 2 cases(5.5%), necklace in 2 cases(5.5%) and others. The locations of foreign bodies were upper esophagus in 12 cases(32.5%), lower esophagus in 4 cases(10.8%), stomach in 16 cases(43.2%), small bowel in 5 cases(13.5%). 4. Presenting symptoms were variable with asymptomatic(59.4%), vomiting(19.0%), epigastric pain(8.1%), dysphagia(5.4%) and others. The methods for removal of foreign bodies included 20 cases of endoscopic removal(54.0%). 3 cases of spontaneous removal(8.1%) and there was no surgical removal. 14 cases(37.9%) did not confirmed removal of foreign body because of no revisit of our hospital. Endoscopic finding of patients were normal(15 cases), ulceration(2 cases), erosion(1 case), inflammation(1 case), mucosal scratch(1 case). Conclusion: It appears that the endoscopic approach is the preferable method for the removal of upper gastrointestinal foreign bodies in the children.

  • PDF

Comparative Analysis of Fracture Angulation between Parallel Pinning and Plate Fixation Techniques in the Management of 5th Metacarpal Fractures (제 5 수지 중수골 골절에서 평행 핀 또는 플레이트 고정술 이후 골절각 변화에 대한 비교 연구)

  • Lee, Myungchul;Shin, Hyojung;Choi, Hyungon;Kim, Jeenam;Shin, Donghyeok
    • Archives of Hand and Microsurgery
    • /
    • v.23 no.4
    • /
    • pp.230-238
    • /
    • 2018
  • Purpose: Metacarpal fractures are common injuries of the hand. They are treated using closed reduction (CR) or open reduction (OR) techniques. The management strategy depends on fracture site characteristic and fixation methods. In this study, we evaluated pre- and postoperative fracture angulation, when metacarpal fractures bad been treated using two different techniques: CR with parallel transverse pinning and OR with plate fixation. Methods: Forty-six patients undergoing anatomic reduction to treat extra-articular metacarpal fractures were recruited. They were included in one of two therapeutic groups: Group 1, CR with parallel transverse pinning (n=21); Group 2, OR with plate fixation (n=25). Fracture angulation values have been measured on pre- and postoperative radiologic images. Values were compared between pre- and postoperative states, and between corresponding measurements of each group. Results: All extra-articular metacarpal fractures were successfully treated without wound related complications or the limit of joint motion. Both groups demonstrated adequate reduction at immediate postoperative period (postoperative angulation of group 1, $20^{\circ}{\pm}7^{\circ}$; group 2, $19^{\circ}{\pm}5^{\circ}$). During the observation at follow-up period, Group 1 exhibited slight recurrence (follow-up angulation of group 1, $24^{\circ}{\pm}10^{\circ}$). Nonetheless, Group 2 showed adequate reduction state in both immediate postoperative and long-term follow-up periods (follow-up angulation of group 2, $18^{\circ}{\pm}6^{\circ}$). Conclusion: Extra-articular metacarpal fractures were successfully restored without functional complications. CR with parallel transverse pinning method exhibited recurrence after pin removal, which necessitates cautious postoperative exercise and monitoring.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • Journal of Biomedical Engineering Research
    • /
    • v.6 no.2
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF