• 제목/요약/키워드: Pin Joint

검색결과 172건 처리시간 0.029초

304 스테인레스 스틸의 마찰교반접합 (Friciton stir welding of type 304 stainless steel)

  • 이창용;최돈현;표성은;이원배;이종봉;연윤모;정승부
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2007년 추계학술발표대회 개요집
    • /
    • pp.158-160
    • /
    • 2007
  • The butt and lap configurational friction stir welding of type 304 stainless steel was conducted in this study. The sound joints were obtained by WC tool. As the welding distance increased, tool deformation gradually increased at the pin edge. The discoloration by oxidation was observed at the top surface of the joint, a sufficient heat-input was required to avoid the welding defect owing to the lack of stirring at the welding start point. Very fine grains were observed in the stir zone, and the grain coarsening was not observed in the heat affected zone.

  • PDF

Virtual Qualification을 통한 자동차용 전장부품의 수명 평가 (Life Assessment of Automotive Electronic Part using Virtual Qualification)

  • 이해진;이정윤;오재응
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.143-146
    • /
    • 2005
  • In modern automotive control modules, mechanical failures of surface mounted electronic components such as microprocessors, crystals, capacitors, transformers, inductors, and ball grid array packages, etc., are mai or roadblocks to design cycle time and product reliability. This paper presents a general methodology of failure analysis and fatigue prediction of these electronic components under automotive vibration environments. Mechanical performance of these packages is studied through finite element modeling approach fur given vibration environments in automotive application. Using the results of vibration simulation, fatigue lift is predicted based on cumulative damage analysis and material durability information. Detailed model of solder/lead joints is built to correlate the system level model and obtain solder strains/stresses. The primary focus in this paper is on surface-mount interconnect fatigue failures and the critical component selected for this analysis is 80 pin plastic leaded microprocessor.

  • PDF

Stairs Adaptable Wheeled Mobile Robotusing Passive Linkage Mechanism

  • Woo, Chun-Kyu;Kim, Soo-Hyun;Kwak, Yoon-Keun;Kim, Mun-Sang
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.30.3-30
    • /
    • 2001
  • In this paper, we designed the 6-wheeled mobile robot (6-WMR) with the passive linkage mechanism which enables 6-WMR to passively adapt to the given stairs. To overcome the limit of adaptability to the terrain of conventional WMR and improve the energy efficiency, we proposed the new WMR using the passive linkage mechanism. The passive linkage mechanism consists of the simple four-bar linkage mechanism which allows 6-WMR to climb stairs with adaptability and an additional link which is connected to the four-bar linkage mechanism by a pin-slot joint to enable 6-WMR to passively go up the stairs. We made a miniature model of the proposed 6-WMR ...

  • PDF

컨테이너 임시교사의 품질개선방안 (Measures for Improving the Quality of Temporary Container Classrooms)

  • 유병재;방홍순;이종성;김옥규
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 봄 학술논문 발표대회
    • /
    • pp.38-39
    • /
    • 2021
  • The use of temporary container classrooms has increased in recent years due to the development of the construction industry and renovation or rehabilitation of schools. Therefore, various problems, such as errors during assembling, design and insulation issues, and noise problems, have surfaced during the construction of temporary container classrooms. This study analyzes the causes of assembly errors during the manufacturing and installation processes to improve the quality of temporary container classrooms. Assembly errors are caused by non-level planes and inaccurate cutting during the manufacturing process. In the installation process, poor leveling is a major factor that causes errors during the assembly of temporary container classrooms. These causes result in uneven horizontal or vertical planes and uneven height. To solve these problems, quality improvement measures, such as pin connection, jig, joint coupling, and surface plates are proposed in this study.

  • PDF

가골 신연술로 치료한 제 1 중족골 단축증 (Brachymetatarsia of the First Metatarsal treated by Callotasis)

  • 이근배;김병수;박유복;문은선;최진
    • 대한족부족관절학회지
    • /
    • 제9권2호
    • /
    • pp.140-145
    • /
    • 2005
  • Purpose: To analyze the outcome of metatarsal lengthening of first brachymetatarsia by callotasis using an external fixator. Materials and Methods: Between January 1998 and February 2004, 10 patients (17 cases) were reviewed. The mean age at operation was 17.3 years. Seven patients had bilateral first brachymetatarsia and eight patients had combined 4th brachymetatarsia. The operations were performed with a monoexternal fixator, and distraction was started at a rate of 0.75 mm/day after 7 days. The radiographic results were evaluated by lengthening amount and percentage, fixation time, and healing index. Complications and AOFAS score were evaluated. Results: The average lengthening amount was 17.7 mm and the average lengthening percentage was 43.4%. The external fixation time was 107 days and average healing index was 69.8 days/cm. The evaluation according to AOFAS score was excellent in 12 cases and good in 5 cases. Complications were 4 cases of hallux valgus, 4 of metatarsophalangeal joint stiffness, 3 of medial angular deformity, 3 of pes cavus, 2 of pin breakage, 2 of pin site infection, and 1 of skin hyperpigmentation. Conclusion: Callotasis for 1st brachymetatarsia is a very useful treatment method with high patient satisfaction, excellent healing rate and early ambulation without bone graft. Nevertheless, great care must be taken to minimize the various possible complications.

  • PDF

좌굴 및 비선형성을 고려한 중형 수평축 풍력터빈용 샌드위치 복합재 회전날개의 설계 개선에 관한 연구 (Stress Analysis of Composite Rotor Blade with Sandwich Structure for Medium Class HAWT)

  • 공창덕;오동우;방조혁
    • 한국추진공학회지
    • /
    • 제2권3호
    • /
    • pp.1-9
    • /
    • 1998
  • 풍력에너지는 자연의 에너지를 이용하므로써 환경문제와 경제적 측면에서 다른 대체 에너지보다 훨씬 유리하여 세계 여러 나라에서 각광을 받고 있다. 경제적인 이유로 풍력발전을 위한 회전날개가 대형화 되고 있으며, 경량화를 위해 복합재 구조등의 첨단 항공기술이 적용되고 있는 추세이다. 본 연구에서는 500㎾급 중형 풍력 발전시스템을 개발함에 있어, 적합한 공력 성능을 갖는 경량화 복합재 회전날개의 개선 설계를 수행하였다. 회전날개의 경량화를 위해 기 설계된 쉘-스파 구조물을 쉘-스파-샌드위치 구조물로 설계를 수정하였고, 배선형 해석을 통해서 경량화에 따른 대변형 문제를 검토하였으며, 파괴응력보다 낮은 상태에서 발생되는 국부좌굴에 의한 구조물의 안전성을 검토하였다. 또한, 허브의 금속재 삽입부분의 전단핀에 의한 핀 홀 주위의 응력해석을 수행하여 충분히 안전함을 확인하였고, 수정 설계된 구조물이 운용구간내에서 공진이 발생하지 않음을 확인하였다.

  • PDF

전위성 치골 골절의 경피적 고정술: 술기보고 (Percutaneous Screw Fixation in a Displaced Pubic Fracture: Technical Note)

  • 공규민;김승철
    • 대한정형외과학회지
    • /
    • 제56권4호
    • /
    • pp.361-365
    • /
    • 2021
  • 골반골 골절은 고에너지 손상이며 주변 조직 및 장기의 손상이 동반되는 경우가 흔하다. 골반 외상 환자에서 적절한 치료가 제공되지 않으면 사망률이 높아지므로 수상 초기에 적극적인 치료를 요하게 된다. 하지만 광범위한 수술을 시행하기에는 환자의 상태가 허락되지 않는 경우가 많아서 최소 침습적인 수술을 고려하게 된다. 치골의 경피적 고정은 피부 절개를 크게 하지 않고도 골반의 전방부 안정성을 획득할 수 있는 방법으로 비교적 쉽게 적용할 수 있어 여러 문헌에서 소개되고 있다. 그러나 대부분의 문헌에서는 비전위성 골절에 대한 나사 고정을 기술하고 있으며 전위성 골절을 경피적 나사 고정으로 치료할 때 비구의 관절면을 침범하지 않는 위치로 나사를 삽입하는 것이 어려운 점은 간과되고 있다. 저자는 치골의 전위성 골절의 경피적 나사 고정 시 구부러진 유도핀을 이용하여 관절면의 침범을 피하면서 유관나사를 쉽게 삽입할 수 있었기에 본 술식을 소개하고자 한다.

SMART 프레임의 공기단축 효과 분석 - 대형 물류창고 사례 - (Time Reduction Effect Analysis of SMART Frame for Long Span and Heavy Loaded Logistics Buildings)

  • 김도영;지우민;임지영
    • 한국건축시공학회지
    • /
    • 제22권5호
    • /
    • pp.519-530
    • /
    • 2022
  • 인터넷 상거래가 증가함에 따라 전세계적으로 대형 물류 건물의 건설이 증가하고 있다. 이들 건축물은 대부분 장경간중재하의 특성을 가지고 있으며 빠른 시공을 위해 핀조인트 구조인 PC 공법을 적용한다. 그러나 핀조인트 구조는 시공 안전성 및 구조적 안정성으로 인해 PC 부재의 설치에 많은 제약이 있어 시간과 비용이 많이 소요된다. 이러한 제약과 문제점을 해결하기 위해 PC 부재 사이의 철골 조인트로 연결된 구조 프레임인 SMART frame이 개발되었다. SMART frame에 대한 많은 연구가 진행되었으나 공기 측면에 대한 영향은 분석되지 않았다. 본 연구의 목적은 장경간 중재하 물류창고시설에 대한 SMART frame의 공기단축 효과를 분석하는 것이다. 본 연구를 위해 기존 PC 공법에 의해 건설된 사례현장을 선정하여 SMART frame 설치 시뮬레이션과 시간 단축을 비교하였다. 그 결과, 기존 PC설치공기의 약48%의 수준으로 약 4개월이 단축 되었다. 추후 대형물류센터 프로젝트 진행 시 SMART frame을 적용한다면 기존 PC공법 대비 획기적인 공기단축의 효과를 가질 것으로 기대된다.

GFRP 보강적층판 및 GFRP rod를 이용한 낙엽송 집성재 접합부의 모멘트저항 성능평가 (Moment Resistance Performance Evaluation of Larch Glulam Joints using GFRP-reinforced Laminated Plate and GFRP Rod)

  • 정홍주;송요진;이인환;홍순일
    • Journal of the Korean Wood Science and Technology
    • /
    • 제44권1호
    • /
    • pp.40-47
    • /
    • 2016
  • 구조용 집성재 라멘 접합부에 일반적으로 사용되는 접합철물을 대신하여 단판과 GFRP (Glass Fiber Reinforced Plastic)를 복합시킨 GFRP 보강적층판과 삽입 접착형 GFRP rod를 접합물로 사용하였다. 이들을 적용시킨 접합부에 대한 모멘트저항 성능평가 결과, 접합철물을 이용한 실험체(Type-1)와 비교하여 GFRP 보강적층판과 GFRP rod 핀을 사용한 실험체의 항복모멘트는 4% 낮게 측정되었으나 회전강성은 29% 높게 측정되었다. 또한 GFRP 보강적층판과 목재(Eucalyptus marginata)핀을 사용한 실험체는 Type-1 실험체와 비교하여 항복모멘트 11%, 회전강성 56% 높게 측정되며 가장 양호한 성능을 나타냈었다. 파괴형상과 완전탄소성 분석을 통해서도 핀에 의한 전단내력으로부터의 취성파괴가 아닌 연성거동을 나타내며, 접합내력이 상승하고 부재의 일체화가 이루어짐을 확인하였다. 반면, GFRP rod를 삽입 접착한 실험체는 접착 불량으로 측정이 불가하거나 접합성능이 매우 낮게 측정되었다.

Characterization of Tribocorrosion Behaviour of CoCr Alloy by Electrochemical Techniques in Several Corrosive Media

  • Escudero, M.L.;Diaz, I.;Martinez Lerma, J.F.;Montoya, R.;Garcia-Alonso, M.C.
    • Corrosion Science and Technology
    • /
    • 제17권2호
    • /
    • pp.68-73
    • /
    • 2018
  • Substitution of hip and knee joints by CoCr alloys is in great demand due to their high wear resistance and good biocompatibility. Understanding of tribocorrosion in joint replacements requires study of variables such as coefficient of friction and the choice of a proper corrosive medium in wear-corrosion tests carried out in the lab. The objective of this study was to characterize tribocorrosion behaviour of CoCr alloy with low (LCCoCr) and high carbon (HCCoCr) contents in several corrosive media: NaCl, Phosphate Buffer Solution (PBS), and PBS with hyaluronic acid (PBS-HA). Tribocorrosion tests were carried out on a pin-on-disk tribometer with an integrated electrochemical cell. A normal load of 5N was applied on the alumina ball counterpart at a rotation rate of 120 rpm. Coefficient of friction (COF) was measured and tribocorrosion behaviour was characterized by in situ application of electrochemical techniques. HCCoCr alloy immersed in PBS-HA showed the best tribocorrosion behaviour with the lowest COF. In this case, in situ measurement of corrosion potential and the impedance data under wear corrosion process showed an active state while passive film was continuously destroyed without possibility of regeneration.