• Title/Summary/Keyword: Pin

Search Result 2,848, Processing Time 0.041 seconds

Compressive Behavior of Precast Concrete Column with Hollow Corresponding to Hollow Ratio (중공비율에 따른 중공 프리캐스트 철근콘크리트 기둥의 압축거동)

  • Lee, Seung-Jun;Seo, Soo-Yeon;Pei, Wenlong;Kim, Kang-Su
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.4
    • /
    • pp.441-448
    • /
    • 2014
  • From several researches, recently, it was found that using hollowed precast concrete (HPC) column made more compact concrete casting in joint region possible than using normal solid PC (Precast concrete) column. Therefore, the rigidity of joints can be improved like those of monolithic reinforced concrete (RC). After filling the hollow with grout concrete, however, it is expected that the HPC column behaviors like composite structure since PC element and grout concrete have different materials as well as there is a contact surface between two elements. These may affect the structural behavior and strength of the composite column. A compressive strength test was performed for the HPC column with parameter of hollow ratio for the case with and without grout in the hollow and the result is presented in this paper. The hollow ratios in the test are 35, 50 and 59% of whole section of column. Concentrated axial force was applied to top of the specimens supported as pin connection for both ends. In addition, finite element (FE) analysis was performed to simulate the failure behavior of HPC column for axial compression. As a result, it was found that the hollow ratio did not affect the initial stiffness of HPC filled with grout regardless of the strength difference of HPC and grout. However the strength was increased inversely corresponding to the hollow ratio. The structural capacity of HPC without grout closely related to the hollow size. Especially, the local collapse governs the overall failure when the thickness of HPC is too thin. Based on these effect, a suitable equation was suggested for calculation of the compressive strength of HPC column with or without grout. FE analysis considering the contact surface between HPC and grout produced a good result matched to the test result.

Antioxidant and α-Glucosidase Inhibitory Effect of Tartary Buckwheat Extract Obtained by the Treatment of Different Solvents and Enzymes (용매 종류와 효소 처리에 따른 쓴 메밀 추출물의 항산화 활성 및 α-Glucosidase 저해 활성의 변화)

  • Kim, Ji-Eun;Joo, Sung-Il;Seo, Ji-Hyun;Lee, Sam-Pin
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.38 no.8
    • /
    • pp.989-995
    • /
    • 2009
  • Extract yield of tartary buckwheat treated with water, 70% ethanol or methanol were about 13.6%, 7.0% and 6.6%, respectively. Extract yield was greatly increased by the treatment of $\alpha$-amylase indicating 95.1% yield. $RC_{50}$ value of DPPH radical scavenging activity with methanol and 70% ethanol extracts were 34.0 $\mu g$/mL, 40.5 $\mu g$/mL, respectively. The DPPH radical scavenging activity increased when it was treated with $\beta$-glucosidase and cellulase, showing $RC_{50}$ value of 24.7 $\mu g$/mL and 25.0 $\mu g$/mL, respectively. In ABTS radical scavenging activity, methanol extract (100 $\mu g$/mL) showed 30% inhibition. In DPPH or ABTS radical scavenging activities, the treatment of $\beta$-glucanase and $\alpha$-amylase shows the highest and the lowest activities, respectively. In $\alpha$-glucosidase inhibitory effect, 70% ethanol extract showed $RC_{50}$ value of 59.9 $\mu g$/mL, but water extract was not inhibitory effective. The $\alpha$-glucosidase inhibitory effect was the highest in multi enzyme treatment. Content of rutin and quercetin in methanol extract showed higher value with 4400.3 mg% and 71.9 mg%, respectively. The 70% ethanol extract of buckwheat contained rutin of 3459.8 mg% and quercetin of 56.9 mg%. In the treatment of $\beta$-glucanase, the rutin content of ethanol extract increased with 5057.4 mg% and multi-enzyme treatment resulted in the modification of rutin glycoside.

Clinical Results of Arthroscopic Anterior Cruciate Ligament Reconstruction using Hamstring Tendon (슬괵건을 이용한 관절경적 전방십자인대 재건술)

  • Song, Eun-Kyoo;Seo, Hyoung-Yeon;Lee, Geun-Bae;Yoon, Taek-Rim;Shim, Sang-Don
    • Journal of the Korean Arthroscopy Society
    • /
    • v.3 no.1
    • /
    • pp.17-23
    • /
    • 1999
  • Purpose : We intend to review clinical results after Anterior cruciate ligament(ACL) reconstruction using hamstring tendon arthroscopically. Materials & Methods : Sixty two patients who had underwent arthroscopic ACL reconstruction using hamstring tendon from Mar. 1996 to Mar. 1997 were reviewed. The average follow-up was 16 months and average age at operation was 27 years old. Clinical results were evaluated with physical examination, Lysholm Knee score and instrumented anterior laxity test with Telos Results : The average preoperative Lysholm knee score was 57.0 and postoperative average of that was 91.8. All cases of 62 patients had normal range of motion of knee and were able to walk with no problems at follow-up. On the Lachmann test, there were mild(+) instability in 24 cases, moderate(++) in 24 cases, severe(+++) in 14 cases preoperatively and 48 cases were converted to negative, 14 cases mild postoperatively. On instrumented anterior laxity test with Telos, difference between normal and affected knee on 20 lb which was 13.4mm preoperatively was decreased to 4.7mm at follow-up and anterior stability was regained(P<0.05). Parapatellar complications such as crepitus in 18 cases(29.5%), atrophy of quadriceps in 23 cases(36.5%) were observed. There were 2 cases of inaccuracy of guide pin of semifix screw intraoperatively and 3 cases of malposition of semifix screw postoperatively. Conclusion : ACL reconstruction using hamstring tendon seems to be a effective procedure to establish the stability of knee joint but is technically demanding procedure and leaves some parapatellar complications.

  • PDF

The Effect of a Tibial Remnant Preservation Technique on the Synovialization of the Graft Tendon in Anterior Cruciate Ligament Reconstruction - Based on the Second Look Arthroscopic Findings - (전방십자인대 재건술시 잔류 조직 보존술이 이식 인대의 활막화(synovialization)에 미치는 영향 - 2차 관절경 소견을 중심으로 -)

  • Ahn, Gil Yeong;Nam, Il Hyun;Moon, Gi Hyuk;Lee, Yeong Hyun;Choi, Seong Pil;Yoo, Jong Yeon
    • Journal of the Korean Arthroscopy Society
    • /
    • v.17 no.1
    • /
    • pp.11-17
    • /
    • 2013
  • Purpose: The purpose of this study is to evaluate the effect of preservation of the tibial remnant on the synovialization of graft tendon after the reconstruction of anterior cruciate ligament (ACL) based on the second look arthroscopic findings. Materials and Methods: From May 2005 to May 2012, among sixty three patients having ACL reconstruction with the four-strand hamstring using a bioabsorbable cross pin (RigidFix$^{(R)}$) for the femoral tunnel, nineteen patients who had second look arthroscopy were analyzed. We classified them into three groups according to the tibial remnant of the torn ACL for arthroscopic findings. Group 1 had less than 5 mm of a remnant tissue, Group 2 had from 6 mm to 10 mm of it, and Group 3 had more than 11 mm. We estimated the percentage of synovial coverage on the graft tendon during second look arthroscopy. We evaluated Lysholm score and Tegner activity score preoperatively and in the last follow-up. Results: At the time of ACL reconstruction, the mean length of preserved tibial remnant of torn ACL was 2.3 mm in Group 1, 7.4 mm in Group 2, and 13.7 mm in Group 3. In the second look arthroscopy, the average percentage of synovial coverage was 55.4% in Group 1, and 77.9% in Group 2, and 89.7% in Group 3. Lysholm score and Tegner activity score improved from 74.2 and 7.3 preoperatively to 94.1 and 8.5 in the last follow-up. Conclusion: The preservation of tibial remnant of torn ACL influenced the synovial coverage of the graft tendon and the volume of preserved remnant in accordance with the surface of synovial coverage. It would have a good effect on graft healing and preservation of proprioceptive function.

  • PDF

Removable implant-supported partial denture using milled bar with Locator® attachments in a cleft lip & palate patient: A clinical report (구순구개열 환자에서 Locator® 유지장치가 장착된 milled titanium bar를 이용한 가철성 임플란트 피개 국소의치의 보철수복증례)

  • Yang, Sang-Hyun;Kim, Kyoung-A;Kim, Ja-Yeong;Seo, Jae-Min
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.3
    • /
    • pp.207-214
    • /
    • 2015
  • Due to the limitations of conventional removable partial denture prostheses to treat a cleft lip & palate patient who shows scar tissue on upper lip, excessive absorption of the maxillary residual alveolar ridge, and class III malocclusion with narrow palate and undergrowth of the maxilla, 4 implants were placed on the maxillary edentulous region and a maxillary removable implant-supported partial denture was planned using a CAD/CAM milled titanium bar. Unlike metal or gold casting technique which has shrinkage after the molding, CAD/CAM milled titanium bar is highly-precise, economical and lightweight. In practice, however, it is very hard to obtain accurate friction-fit from the milled bar and reduction in retention can occur due to repetitive insertion and removal of the denture. Various auxiliary retention systems (e.g. $ERA^{(R)}$, $CEKA^{(R)}$, magnetics, $Locator^{(R)}$ attachment), in order to deal with these problems, can be used to obtain additional retention, cost-effectiveness and ease of replacement. Out of diverse auxiliary attachments, $Locator^{(R)}$ has characteristics that are dual retentive, minimal in vertical height and convenient of attachment replacement. Drill and tapping method is simple and the replacement of the metal female part of $Locator^{(R)}$ attachment is convenient. In this case, the $Locator^{(R)}$ attachment is connected to the milled titanium bar fabricated by CAD/CAM, using the drill and tapping technique. Afterward, screw holes were formed and 3 $Locator^{(R)}$ attachments were secured with 20 Ncm holding force for additional retention. Following this procedure, satisfactory results were obtained in terms of aesthetic facial form, masticatory function and denture retention, and I hereby report this case.

Detection for Residual Thyroid Tissue and Metastatic Lesion after Total Thyroidectomy in Patients with Differentiated Thyroid Cancer: Comparison between Tc-99m Pertechnetate Sean and High Dose I-131 Therapy Sean (분화 갑상선암 환자의 수술후 잔여갑상선조직 및 전이병소의 진단: Tc-99m Pertechnetate 스캔과 고용량 옥소 치료 후 I-131 스캔의 비교)

  • Lee, Joo-Ryung;Ahn, Byeong-Cheol;Jeong, Shin-Young;Lee, Jae-Tae;Lee, Kyu-Bo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.2
    • /
    • pp.120-127
    • /
    • 2003
  • Purpose: To evaluate diagnostic sensitivity of nuclear imaging in the detection of residual thyroid tissue and metastatic lesion, we have compared neck scintigrams with Tc-99m pertechnetate (Tc-99m scan) and high dose I-131 iodide (I-131 scan) in patients with differentiated thyroid cancer. Subjects and Methods: One hundred thirty-five thyroidectomized patients for differentiated thyroid cancer were enrolled in this study. Twenty-three had a previous history of radioiodine therapy. Planar and pin-hole images of anterior neck with Tc-99m were acquired at 20 minutes after injection, followed by I-131 scan three days after high-dose radioiodine therapy within 7 days interval. Patients were asked to discontinue thyroid hormone replacement more than 4 weeks. Results: All subjects were in hypothyroid state. Seventy out of 135 patients (51.9%) showed concordant findings between Tc-99m and I-131 scans. I-131 scan showed higher number of uptake foci in all of 65 patients showing discordant finding. Tc-99m scan showed no thyroid bed uptake in 34 patients, whereas 23 of them (67.6%) showed bed uptake in I-131 scan. Tc-99m scan did not show any uptake in thyroid bed in 11 of 112 patients without previous history of radioiodine therapy, but 9 of them showed bed uptake in I-131 scan. Tc-99m scan showed no bed uptake in all of the 23 patients with previous history of radioiodine therapy, in contrast 14 of them (60.9%) showed bed uptake in I-131 scan. Conclusion: These results suggest that Tc-99m scan has poor detectability for residual thyroid tissue or metastatic lesion in thyroidectomized differentiated thyroid cancer patients, compared to high dose I-131 therapy scan. Tc-99m scan could not detect any remnant tissue or metastatic lesion in patients with previous history of radioiodine treatment, especially.

Quality Characteristics of Soup with Whole Milk Powder and Pleurotus eryngii Powder (전지분유와 새송이버섯 분말을 함유한 스프의 품질특성)

  • Back, Su-Yeon;Kim, Sung Soo;Lim, Sang-Dong;Do, Jeong-Ryong
    • Journal of Dairy Science and Biotechnology
    • /
    • v.35 no.2
    • /
    • pp.113-119
    • /
    • 2017
  • This study investigated the quality characteristics of cream soup added with Pleurotus eryngii powder. Pleurotus eryngii was dried in a hot air dryer at $40^{\circ}C$ for 8 hours and at $60^{\circ}C$ for 8 hours. The dried Pleurotus eryngii was pulverized using a pin mill, and the powder was sieved through a 60~100 mesh. Sensory evaluations of cream soup added with different-sized particles of Pleurotus eryngii powder were performed. Cream soup added with Pleurotus eryngii powder of particles below $150{\mu}m$ showed good appearance, taste, and mouth-feel. Quality characterization of cream soup added with 5~20% Pleurotus eryngii powder showed that L value decreased with increasing Pleurotus eryngii, whereas a and b values increased. Sensory evaluations revealed that cream soup with 15% Pleurotus eryngii powder had significantly better taste, mouth-feel, and overall acceptability (p<0.05) than other samples. Thus, cream soup with 15% Pleurotus eryngii powder of particle size below $150{\mu}m$ was the most desirable and could be successfully used as convenience food in the food processing industry.

Genetic Expression of Color Approved by Color Qualities of Munsell System on the Cocoon of Silkworm, Bombyx mori (누에 고치색 유전자 발현의 다양성 검정 및 색채과학적 해석)

  • Han, Myung-Sae;Park, Hyun-Ro;Han, Sang-Mi;Nam, Ki-Soo;Kwon, Soon-Ha;Lim, Jong-Sung;Nguyen, Mau Tuan
    • Journal of Sericultural and Entomological Science
    • /
    • v.41 no.1
    • /
    • pp.20-28
    • /
    • 1999
  • Color qualities investigated on the basis of Munsell code and Korean standard color code for the cocoons from various strain of mulberry silkworm, Bombyx mori. 16 of different color qualities were identified from 21 of original silworm strains, and determinated international name with the revision of Korean color name for cocoon. The various cocoon color confirmed on the sphere from 567 to 593 nm wavelength, 78% of those located at the region about 580 nm (575~584) of sensitive "color difference limen". Y gene engaged broad ranges of wavelength (575~593 nm) in the color expression, by contrast with other genes of Pk (593 nm), F (584~593), Grc and relative G group (567~570 nm), on the transmission of carotenoid or flavonoid color substance. YC gene expression by original silk worm strain was also distinguished by those variation of specific yellow than other colors from Grc, GaGb, Gc, and YPkF. Appearance of chrome yellow cocoon was dominant than other yellow in the cross among vivid yellow group. F1 of pin${\times}$green produced the cocoon of yellow such as "additive mixture" as color light, however, most of the hybrid between yellow cocoon showed the color similar to "subtractive mixture" as a mixture of dyestuff. Hybrid cocoons among yellow or green colors were decreased their hue, value, and chroma, than those of parent. Diallel cross among the strain of various green cocoon suggest the existence of Grc, Ga, Gb, Gc genes. Cream colored cocoon of B. mandarina was differed from other yellow cocoon of Bobyx mori B. mori. Y$^A$ with Ymc showed the similar role of Y with C, therefore, segregated yellow cocoon from the B. mori${\times}$B. mandarina (+$^YC/Y^AYmc$). YC expression of $Y^AY$mc genes might be suppressed by deficiency of outer layer sericin on the middle division of silk giand in the B. mandarina.

  • PDF

Investigation of the Distance from One Tooth Center to Adjacent Tooth Center and Dental Arch Size to Develope New Removable Die System for Fabrication of Dental Prosthetic Appliance (치과보철물 제조용 모형 조립체(가철식 치형 시스템) 개발을 위한 인접 치아 중심 간격 및 악궁 크기 조사)

  • Kim, Bu-Sob;Ma, Seung-Ho;Jeong, Kyung-Mok;Byun, Tae-Hee
    • Journal of Technologic Dentistry
    • /
    • v.29 no.2
    • /
    • pp.151-161
    • /
    • 2007
  • To obtain the information of dental arch size and the distance from one tooth center to adjacent tooth center of occlusal surface of each tooth which is perforated by Pindex system on working cast for removable die system, 600 dental casts in Busan were examined. The distance of center of occlusal surface of each tooth and dental arch size were digitized. The results were as follows; 1. Mean values of the distance from center of maxillary central incisor to maxillary lateral incisor(tooth number 11$\sim$12, 21$\sim$22) is 5,7 mm, 12$\sim$13(22$\sim$23) is 5.9 mm, 13$\sim$14(23$\sim$24) is 6.9 mm, 14$\sim$15(24$\sim$25) is 7.1 mm, 15$\sim$16(25$\sim$26) is 8.4 mm, 16$\sim$17(26$\sim$27) is 10.2 mm, 11$\sim$21 is 7.30 mm. Mean values of the distance from center of mandibular central incisor to mandibular lateral incisor(tooth number 31$\sim$32, 41$\sim$42) is 4.5 mm, 32$\sim$33(42$\sim$43) is 4.8 mm, 33$\sim$34(43$\sim$44) is 6.3 mm, 34$\sim$35(44$\sim$45) is 7.2 mm, 35$\sim$36(45$\sim$46) is 9.2 mm, 36$\sim$37(46$\sim$47) is 10.7 mm, 31$\sim$41 is 4.7 mm. 2. Mean values of the distance from the center of maxillary right central incisor to the center of maxillary left central incisor(11$\sim$21) is 7.3 mm, 12$\sim$22 is 18.2 mm, 13$\sim$23 is 26.9 mm, 14$\sim$24 is 37.2 mm, 15$\sim$25 is 43.2 mm, 16$\sim$26 is 48.5 mm, 17$\sim$27 is 53.5 mm. Mean values of the distance from the center of mandibular right central incisor to the center of mandibular left central incisor(31$\sim$41) is 4.7 mm, 32$\sim$42 is 13.3 mm, 33$\sim$43 is 21.7 mm, 34$\sim$44 is 31.9 mm, 35$\sim$45 is 38.2 mm, 36$\sim$46 is 44.8 mm, 37$\sim$47 is 50.7 mm. 3. Mean values of the distance from the line of between 11$\sim$21 to 12$\sim$22 is 10.9 mm, 12$\sim$22 to 13$\sim$23 is 8.7 mm, 13$\sim$23 to 14$\sim$24 is 10.3 mm, 14$\sim$24 to 15$\sim$25 is 6.0 mm, 15$\sim$25 to 16$\sim$26 is 5.3 mm, 16$\sim$26 to 17$\sim$27 is 5.0 mm. 31$\sim$41 to 32$\sim$42 is 8.6 mm, 32$\sim$42 to 33$\sim$43 is 8.4 mm, 33$\sim$43 to 34$\sim$44 is 10.2 mm, 34$\sim$44 to 35$\sim$45 is 6.3 mm, 35$\sim$45 to 36$\sim$46 is 6.6 mm, 36$\sim$46 to 37$\sim$47 is 5.9 mm. 4. We checked the bottom side of cast to verify the position of dowel pin. There is no difference upper side and lower side.

  • PDF

ACL Reconstruction using Transtibial Femoral Tunnel at 10 or 2 O'clock Position - Technical Note - (10시 혹은 2시 방향의 경경골 대퇴 터널을 이용한 전방 십자 인대 재건술 - 수술 수기 -)

  • Cho, Sung-Do;Ko, Sang-Hun;Park, Mun-Soo;Jung, Kwang-Hwan;Cha, Jae-Ryong;Gwak, Chang-Youl;Kim, Sang-Woo
    • Journal of the Korean Arthroscopy Society
    • /
    • v.10 no.2
    • /
    • pp.209-213
    • /
    • 2006
  • Purpose: Conventional transtibial approach for the anterior cruciate ligament (ACL) reconstruction tended to place the femoral tunnel in too vertical position (11 or 1 o'clock), which could provide the postoperative anteroposterior (AP) stability but not provided the rotational stability. Therefore we present a surgical technique to make the transtibial femoral tunnel at 10 or 2 o'clock position. Surgical approach: To make a transtibial femoral tunnel at the 10 or 2 o'clock position, the direction and position of the tibial drill guide was important. We set the tibial drill guide at $40{\sim}45$ degrees and the intraarticular guide tip was 1 mm anterior and medial to the conventional site. The starting point for the guide pin on the proximal tibia was proximal to the pes anserinus and anterior to the medial collateral ligament. The tibial tunnel was initially drilled 1mm less than the diameter of the graft. Then femoral offset guide could be easily placed at 10 or 2 o'clock position through the tibial tunnel. The tibial tunnel and the femoral tunnel of 30 mm in length were made with the reamer that was same size with the graft. Conclusion: We report a surgical technique to create a transtibial femoral tunnel at 10 or 2 o'clock position in ACL reconstruction to provide the rotational stability as well as the AP stability.

  • PDF