• Title/Summary/Keyword: Pilot scale system

Search Result 357, Processing Time 0.023 seconds

Operating Characteristics of Pilot Scale Multi-Staged Waste Pyrolysis & Gasification System (파일럿 규모의 폐기물 다단열분해 가스화시스템의 운전특성)

  • Lee, Jeong-Woo;Yu, Tae-U;Bang, Byeong-Ryeol;Moon, Ji-Hong;Lee, Jae-Uk;Park, Sang-Shin;Kim, Nack-Joo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.331-335
    • /
    • 2009
  • A novel multi-staged waste pyrolysis & gasification system of pilot scale (~1 ton/day) is designed and constructed in Korea Institute of Industrial Technology. The pyrolysis & gasification system is composed of pyrolysis & gasification system, syngas reformer, syngas cleaning system, gas engine power generation system and co-combustion system. For each unit process, experimental approaches have been conducted to find optimal design and operating conditions. As a result, We can produce syngas with a calorific value of ~4000 kcal/$Nm^3$ and cold gas efficiency of the system is more than 55 % in case of waste plastic and oxygen as a gasifying agent.

  • PDF

Pilot Hopping Scheme for Massive Antenna Systems in Cellular Networks (극다중 안테나 셀룰러 시스템을 위한 파일럿 도약 기법)

  • Kim, Seong Hwan;Ban, Tae-Won;Lee, Wongsup;Ryu, Jong Yeol
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.4
    • /
    • pp.718-723
    • /
    • 2017
  • We propose a pilot hopping scheme that improves the limited system capacity due to pilot contamination in multi-cell environment with large-scale antenna arrays at a base station, assuming the infinite number of antennas. In the conventional fixed pilot scheme, each user obtains the same signal-to-interference ratio (SIR) over a long period of time. Therefore, a user with strong interference has continuously low SIR which degrades its service quality. In the proposed pilot hopping scheme, different pilot signals are used for each time slot, and different amounts of interference are received every time. When such a pilot hopping technique is applied, the SIR fluctuates at every time slot. When the Hybrid Automatic Repeat & reQuest (HARQ) technique is applied in such a channel, the outage probability and transmission rate are improved. We show that there is the performance gain of the proposed scheme over the conventional scheme through computer simulations.

Mixture treatment of food waste and sewage sludge using pilot scale anaerobic digester (Pilot scale 2단 혐기성 소화조를 이용한 음식물쓰레기와 하수슬러지의 혼합처리)

  • Park, Nam-bae;Lee, Heon-Mo;Lee, Byung-Heon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.7 no.2
    • /
    • pp.47-55
    • /
    • 1999
  • Recently, the treatment of that wastes according to increase of food waste has been a great problem of modern society for long time. This study was aimed to evaluate possibility for food waste and sewage sludge mixture treatment using pilot scale two-phase anaerobic digester. Pilot scale two-phase anaerobic digestion system was performanced at 1 : 9 mixture ratio of food waste and sewage sludge infield. The detention time of digester was 20days. The average COD and VS removal efficiencies in organic loading rate $3.03kg\;TCOD/m^3-day$ were 57.7 and 47.7%, and the gas production rate and methane content were $0.4m^3/kg$ VS-day and 65.3%, respectively. TS, VS and VS/TS(%) of mixing tank were 4.44%, 2.59% and 58.34%, respectively and TS. VS and VS/TS(%) of digester in steady state were 3.32%, 1.39% and 41.90%, respectively, Through this study. it was possible to accomplish effective mixture treatment of the sewage sludge and food waste.

  • PDF

Pilot 규모 biopile에 의한 유류오염토양의 정화

  • 김태승;박종겸;윤정기;노회정;정일록;김종하
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.04a
    • /
    • pp.205-208
    • /
    • 2004
  • Tile pilot scale biopile system was designed and constructed for evaluation of biopile efficiency. For the biopile system construction, two soil samples that were contaminated by mainly diesel were selected. The pilot scale biopile were consisted of the biopile dome, aeration system and monitoring system and two biopiles(pile A and pile B) were operated with nutrients and inoculum for more 100 days. The initial TPH concentrations for pile A and pile B were about 10,000 mg/kg and 2,300 mg/kg, respectively. After 70 days, the microbial densities in the pile A was increased and in the pile B it was no changed. The TPH contents decreased about 70% in the pile A and 30% in the pile B. Also, various kinds of PAHs were detected by analyzing the GC/MSD, and the reducing ratio in the piles A and pile B were similarly declined. The average biodegradation rates were calculated about 66.8mg/kg-day in the pile A and 10.9mg/kg-day in the pile B. During the operation period, pile temperature was the major limiting condition for the efficiency of all biopiles.

  • PDF

Influence of Control Variables on the Aerobic Biodegradation Performance in Bin Composting System (회분식 퇴비화 시스템에서 제어변수가 호기성 분해성능에 미치는 영향)

  • 박금주;홍지형
    • Journal of Biosystems Engineering
    • /
    • v.24 no.4
    • /
    • pp.359-364
    • /
    • 1999
  • A theoretical model was developed to evaluate the influence of control variables on the composting performance in a bin composting system. The model was verified using pilot scale composting system. Simulation of the composting temperature according to air flow rate and composting bin size was conducted using the mathematical model. High composting temperature above 55$^{\circ}C$ needed to kill a pathogen was maintained for longer periods as the air flow rate was lower and the bin size was larger. Optimum air flow rate was 0.77L/min/kg.DM for the experimental pilot scale bin system. The size of composting bin should be large enough to maintain the higher composting temperature for required periods.

  • PDF

Bioremediation of Petroleum Contaminated Soils by Pilot Scale Biopile (Pilot 규모 biopile에 의한 유류오염토양의 정화)

  • Yoon, Jeong Ki;Noh, Hoe-Jung;Kim, Hyuk;Kim, Jong Ha;Kim, Tae Seung;Ko, Sung Hwan
    • Journal of Soil and Groundwater Environment
    • /
    • v.18 no.2
    • /
    • pp.10-18
    • /
    • 2013
  • The pilot scale biopile system was designed and operated for evaluation of bioremediation efficiency for petroleum contaminated soil. The pilot scale biopile consisted of biopile dome, aeration system and monitoring system and two biopiles were operated with nutrients and inoculum for more 100 days. The test pile A and B were analyzed with regard to pH, total carbon contents, water contents, nutrients (N, P) and TPH. The initial TPH concentrations for pile A and pile B were about 10,000 mg/kg and 2,300 mg/kg, respectively. After 100 days, the TPH contents decreased about 70% in the pile A and 30% in the pile B. Also, n-$C_{17}$/pristane and n-$C_{18}$/phytane ratios in all pile were significantly changed. The microbial densities in the pile A was increased by approximately $10^7$ CFU/g-soil~$10^8$ CFU/g-soil, but there was almost no changed in the pile B. The average biodegradation rates were calculated about 66.8 mg/kg-day in the pile A and 10.9 mg/kg-day in the pile B. Over the course of operation period, pile temperature was considered the major limiting factor for the efficiency of all biopiles.

Experimental study on the capacity of pilot scale FBC for paper sludge (Pilot plant 규모 유동충 소각로의 제지 슬러지 소각 용량에 관한 실험적 연구)

  • La, Seung-Hyuck;Moon, Dong-Jin;Kang, Kyung-Tae;Shin, Dong-Hoon;Hwang, Jung-Ho
    • 한국연소학회:학술대회논문집
    • /
    • 2002.06a
    • /
    • pp.199-203
    • /
    • 2002
  • In this paper, the effects of water contents on combustion characteristics of paper sludge and capacity of fluidized bed combustor(FBC) were investigated using 0.26m diameter, 1.75m height pilot-plant scale combustor. Combustion tests of paper sludge containing water contents between 40wt% and 50wt% were performed. The temperature and emission variation, the pressure inside combustor were measured to monitor the fluidization quality. The experimental results showed that 30kg/hr feeding rate of sludge containing water up to 45wt% was preferable for this system. Sludge loading rate, heat release rate were calculated from experimental data as major parameters showing FBC capacity. Comparsion with sludge loading rate from other source was also performed

  • PDF

Operational Characteristics of Pilot Scale Plasma DeSOx-DeNOx System for Treatment of Coal-Fired Flue Gas (석탄연소 배가스 처리용 플라즈마 탈황탈질 시스템의 운전 특성)

  • Jang, Gil-Hong;Paek, Min-Su;Kim, Tae-Hee;Jeong, Jong-Han
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1806-1808
    • /
    • 1998
  • Tests of pilot-scale plasma DeSOx-DeNOx system using pulsed streamer corona were carried out. The system consists of the reactor with wire-plate electrodes the $30kW_{max}$. MPC type pulse generator, and $1MW_{th}$ pulverized coal combustor as a flue gas source. $NH_3$ and $C_2H_4$ were used to enhance the removal rate. The experimental result on the removal efficiency of SOx/NOx and on the effect of the additives was presented in this paper.

  • PDF

Prediction of Chlorine Concentration in a Pilot-Scaled Plant Distribution System (Pilot 규모의 모의 관망에서의 염소 농도 예측)

  • Kim, Hyun Jun;Kim, Sang Hyun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.6
    • /
    • pp.861-869
    • /
    • 2012
  • The chlorine's residual concentration prevents the regrowth of microorganism in water transport along the pipeline system. Precise prediction of chlorine concentration is important in determining disinfectant injection for the water distribution system. In this study, a pilot scale water distribution system was designed and fabricated to measure the temporal variation of chlorine concentration for three flow conditions (V = 0.88, 1.33, 1.95 m/s). Various kinetic models were applied to identify the relationship between hydraulic condition and chlorine decay. Genetic Algorithm (GA) was integrated into five kinetic models and time series of chlorine were used to calibrate parameters. Model fitness was compared by Root Mean Square Error (RMSE) between measurement and prediction. Limited first order model and Parallel first order showed good fitness for prediction of chlorine concentration.

복합오염물질 처리를 위한 Hybrid PRB System

  • 김상태;강완협;문희선;민지은;조종수;박주양;김재영;박재우
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.09a
    • /
    • pp.129-132
    • /
    • 2004
  • A hybrid permeable reactive barriers(hybrid PRBs) composed of Fe(II) PRB, biological PRB and sorptive PRB was investigated to treat groundwater with multiple contaminations. We performed batch, column and pilot tests to determine removal rates and design parameters of each PRB media, and operated two hybrid PRB systems with pilot-scale barriers in series. The pilot test of the hybrid PRB system with the combination of Fe(II), biological media and black shale showed multiple contaminations could be removed in ground water. Nitrate could be treated below 20 mg/L and Cr(VI) was treated down to 0.05 mg/L. TCE was degraded below 0.001 mg/L in system. The hybrid PRB system with a proper combination of PRBs could remediate ground water with multiple contaminations.

  • PDF