• Title/Summary/Keyword: Pilot flame

Search Result 59, Processing Time 0.027 seconds

Performance Test of A Reverse-Annular Type Combustor (TS2) for APU (보조동력장치용 환형 역류형 연소기 (TS2) 성능 시험)

  • Ko, Young-Sung;Han, Yeoung-Min;Yang, Soo-Seok;Lee, Dae-Sung;Yun, Sang-Sig;Choi, Sung-Man
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.840-845
    • /
    • 2001
  • Development of a small gas-turbine combustor for 100kW class APU(Auxiliary Power Unit) has been performed. This combustor is a reverse-annular type and has a tangential swirler in the liner head to improve the fuel/air mixing and flame stability. Three main and three pilot fuel injectors of the simplex pressure-swirl type are used. The performance target at the design condition includes a turbine inlet temperature of 1170K, a combustion efficiency of 99%, a pattern factor of 30%, and an engine durability of 3000 hours. Under developing the combustor, we conducted performance test of our first prototype(TS1) with some variants. As a result of the test, the performance targets of the combustor are satisfied except that the pattern factor is about 4% higher than target value. So, we redesigned the second prototype(TS2) and conduct performance test with the critical focus on pattern factor and exit mean temperature. We adopted TS2 four variant to check the improvement of pattern factor. As the result, the pattern factors of several variants were satisfied with the performance target. Finally, We chose the TS2A variant as a final combustor for our APU model.

  • PDF

An Experimental Study on Slagging/Fouling Characteristics for Various Coals in a 50kWth Pulverized Coal Combustion System (50kWth미분탄 연소 시스템에서 탄종별 슬래깅 및 파울링 특성 연구)

  • Kang, Kieseop;Lee, Jaewook;Chae, Taeyoung;Ryu, Changkook;Yang, Won
    • 한국연소학회:학술대회논문집
    • /
    • 2012.11a
    • /
    • pp.107-109
    • /
    • 2012
  • In Korean coal power plants, rising coal prices have recently led to the rapid utilization of low lank coals such as sub-bituminous coal with low calorific values and low ash fusion temperatures. Using these coals beyond the design range has resulted in important issues including slagging and fouling, which cause negative effects in boiler performances and unstable operations. The purpose of this study is to observe slagging and fouling characteristics resulted from burning various ranks of pulverized coals. We have tested 3 different coals: FLAME(bituminous), KCH(sub-bituminous) and MOOLARBEN(bituminous)coals in the pilot system $50kW_{th}$ scale. A stainless steel tube with preheated air inside was installed in the downstream in order to simulate water wall. Collected ash on the probe and the slag inside the furnace near burner were analyzed by SEM (scanning electron microscopy) to verify the formation degree, surface features and color changes of the pasty ash particles. Induced coupled plasma and energy dispersive X-ray spectroscopy were also performed to figure out the chemical characteristics of collected samples. As a result, KCH was observed that more slag was developed inside the walls of the furnace and on the probe than the other two kinds of coals, as shown in the calculate slagging and fouling indices as well.

  • PDF

An Experimental and Numerical Study on the Oxy-MILD Combustion at Pilot Scale Heating Capacity (Pilot급 산소 MILD 연소에 관한 실험 및 수치해석적 연구)

  • Cha, Chun-Loon;Lee, Ho-Yeon;Hwang, Sang-Soon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.7
    • /
    • pp.275-282
    • /
    • 2016
  • MILD (Moderate and Intense Low-oxygen Dilution) combustion using oxygen as an oxidizer is considered as one of the most promising combustion technologies for high energy efficiency and for reducing nitrogen oxide and carbon dioxide emissions. In order to investigate the effects of nozzle angle and oxygen velocity conditions on the formation of oxygen-MILD combustion, numerical and experimental approaches were performed in this study. The numerical results showed that the recirculation ratio ($K_V$), which is an important parameter for performing MILD combustion, was increased in the main reaction zone when the nozzle angle was changed from 0 degrees to 15 degrees. Also, it was observed that a low and uniform temperature distribution was achieved at an oxygen velocity of 400 m/s. The perfectly invisible oxy-MILD flame was observed experimentally under the condition of a nozzle angle of $10^{\circ}$ and an oxygen velocity of 400 m/s. Moreover, the NOx emission limit was satisfied with NOx regulation of less than 80 ppm.

Experimental study on the melting characteristics of pellet fuel for a waste plastic firing boiler (열가소성 폐플라스틱 연소 보일러용 펠렛 연료의 용융특성 실험)

  • Lee, Sung-Soo;Kim, Hyouck-Ju;Choi, Gyu-Sung
    • 한국연소학회:학술대회논문집
    • /
    • 2006.04a
    • /
    • pp.189-193
    • /
    • 2006
  • Experiments were performed to investigate the melting characteristics of pellet fuel made of LDPE and PP for a waste plastic firing boiler. Pellet fuel in a burner goes through conduction, convection and radiation transferred from flame in a furnace, and complex thermo/chemical processes. To figure out effects of ambient temperature and size of pellet on melting time pellets with a diameter from 5 mm to 40 mm were made to contact high temperature flue gas generated by a LNG firing pilot burner. Though melting processes of plastics include complicated heat transfer in a burner, parameters are limited to flue gas temperature and size for the simplicity in this study. From the results, melting times of LDPE and PP with a diameter of 5mm are 63 and 62 secs respectively at 600 $^{\circ}C$ while 677 and 583 sees respectively for a diameter of 40 mm. At $900^{\circ}C$, melting times of LDPE and PP with a diameter of 5mm are 21 and 24 sees respectively while 408 and 337 secs respectively for a diameter of 40 mm. It is found that melting time of LDPE is longer than that of PP, and melting times of both in general increase with diameter of pellets. It is thought melting is dependent mostly on melting temperature of plastic. It is expected melting times obtained from the study might be taken into account in designing a pellet firing burner for a boiler

  • PDF

Combustion Characteristics of Imported Bituminous & Subbituminous Coal in a Pilot Scale Test Facility (발전용 역청탄 및 아역청탄의 파일롯 연소특성 평가)

  • Kim, Hyunhee;Park, Hoyoung;Lim, Hyunsoo;Baek, Sehyun;Kim, Taehyung;Kim, Youngju;Gong, Jiseon;Lee, Jeongeun
    • Journal of Energy Engineering
    • /
    • v.23 no.4
    • /
    • pp.207-214
    • /
    • 2014
  • With the depletion of high grade coal, it is indispensable to be used co-combustion of low rank coal with bituminous coal in pulverized coal-fired power plants. This study describes the detailed measurements of combustion characteristics of bituminous and subbituminous coal in a 0.7MWth pilot-scale test facility. This experimental works include the measurement of gas temperature, gas concentrations along with the reactor axial and radial distance at the condition of excess air ratio of 1.2. The solid sampling was carried out and analyzed with the combustion of bituminous coal. The main reaction zone of coal flame in a reactor was formed about 1 m from the swirl burner, and at downstream, the fully developed temperature and species distribution was observed. The sampled particles of bituminous coal in a reactor revealed the complete carbon burn-out was achieved just after an main combustion zone.

A Pilot Study on Emission Analysis of Air Pollutants Produced from Portable Recycling of Asphalt Concrete (간이이동법에 의한 폐아스콘 재생시 대기오염물의 배출분석에 대한 실험적 연구)

  • Lee, Byeong-Kyu;Kim, Haeng-Ah;Jeong, Ui-Ryang;Duong, Trang;Chae, Po-Gi;Park, Kyung-Won
    • Journal of Environmental Science International
    • /
    • v.16 no.3
    • /
    • pp.385-392
    • /
    • 2007
  • Currently, portable equipment for recycling of waste asphalt concrete (ASCON) has been used. However, any air pollution control devices are not attached in the simple portable one. Thus, a lot of air pollutants have been produced from recycling processes of waste ASCON which resulted from aging of paved roads or repavement of roads. This study deals with a preliminary result of concentration analysis of air pollutants obtained from a pilot and a real recycling processes of waste ASCON using simple portable recycling equipment. Air pollutants were taken from 4 steps of the pilot recycling process including an initial heating by liquid petroleum gas (LPG), intermediate heating and melting (H&M) process, final H&M process, and pavement processes using recycled ASCON at the recycling site. Also, air pollutants were taken front 4 steps of the real recycling processes including an initial H&M, final H&M and mixing, loading of recycled ASCON to dump trucks, and at the recycling site after leaving the loaded dump trucks for real pavement sites. The air pollutants measured in this study include volatile organic compounds (VOCs), aldehydes, particulate matter (PM: PM1, PM2.5, PM7, PM10, TSP (total suspended particulate)). The identified concentrations of VOCs increased with increasing time or degree for H&M of waste ASCON. In particular, very high concentrations of the VOCs at the status of complete melting, which is exposed to the air, of the waste ASCON just before paving tv the recycled ASCON at the recycling site. Also, considerable amount of VOCs were identified from the recycling equipment after the dump trucks leaded by recycled ASCON leaved the recycling site for the pavement sites. The relative level of formaldehyde exceeded 80% of the aldehydes Identified in the recycling processes. This is because the waste ASCON is exposed to direct flame of LPG during H&M processes. The PM concentrations measured in the winter recycling processes, such as the loading and rotation processes of waste ASCON into/in the recycling equipment for H&M, were much higher than those in the summer ones. In particular, the concentrations of coarse particles such as PM7 and PM10 during the winter recycling were very high as compared those during the summer one.

Performance Test of A Reverse-Annular Type Combustor (TS2) for APU (보조동력장치용 환형 역류형 연소기 (TS2) 성능 시험)

  • Ko, Young-Sung;Han, Yeoung-Min;Lee, Kang-Yeop;Yang, Soo-Seok;Lee, Dae-Sung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.6
    • /
    • pp.805-810
    • /
    • 2002
  • Development of a small gas-turbine combustor for 100㎾ class APU(Auxiliary Power Unit) has been performed. This combustor is a reverse-annular type and has a tangential swiller in the liner head to improve the fuel/air mixing and flame stability. Three main and three pilot fuel injectors of the simplex pressure-swirl type are used. The performance target at the design condition includes a turbine inlet temperature of l170k, a combustion efficiency of 99%, a pattern factor of 30%, and an engine durability of 3000 hours. Under developing the combustor, we conducted the performance test of our first prototype(TS1) with some variants. As a result of the test, the performance targets of the combustor are satisfied except that the pattern factor is about 4% higher than the target value. Therefore, the second prototype(TS2) was redesigned and the performance test was conducted with the critical focus on the pattern factor and the exit mean temperature. We adopted TS2 four variants to check the improvement of the pattern factor. As a result, the pattern factors of several variants were satisfied with the performance target. Finally, the TS2A variant was chosen as a final combustor fur our APU model.

Measurements of Indoor and Outdoor Volatile Organic Compounds(VOCs) Concentrations in Ambient Air (실내외 공기중 휘발성 유기화학물질(VOCs)의 농도조사에 관한 연구)

  • 신혜수;김윤신;허귀석
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.9 no.4
    • /
    • pp.310-319
    • /
    • 1993
  • A pilot study was conducted in order to investigate the concentrations of indoor and outdoor VOCs (Volatile Organic Compounds) at ten homes and four building offices in Seoul during March-April, 1993. The five components of VOCs(Benzene, Toluene, Ethylbenzene, o-Xylene, m/p-Xylene) were collected using charcoal tube and were analysed using Gas Chromatography(GC) with a Flame Ionization Detector(FID). The mean concentations of indoor VOCs were shown as Benzene of 38.9 .mu.g/m$^{3}$. Toluene of 165.0 .mu.g/m$^{3}$, Ethylbenzene of 21.7 .mu.g/m$^{3}$, o-Xylene of 11.6 .mu.g/m$^{3}$ and m/p-Xylene of 29.3 .mu.g/m$^{3}$, but those corresponding that indoor levels of VOCs were higher than corresponding outdoor levels. The ratio of indoor and outdoor VOCs were higher than corresponding outdoor levels. The ratio of indoor and outdoor VOCs concentrations was 0.99 for Benzene, 1.23 for Toluene, 5.86 for Ethylbenzene, 5.23 for o-Xylene, 2.41 for m/p-Xylene in homes, while 2.02 for Benzene, 1.15 for Toulene, 0.96 for Ethylbenzene, 1.41 for o-Xylene, 1.38 for m/p-Xylene in offices, respectively. The mean concentrations of VOCs in homes were higher than those levels in offices, while the mean concentration of VOCs during active hour of occupants in a day were higher 1-3 times than the levels during non-active hour. Comparing VOCs levels by building's age, the mean concentrations of Benzene, o-Xylene and m/p-Xylene were higher in new building than old building, but the mean concentrations of Toluene and Etylbenzene in new building were lower than old building. The mean concentrations in all components of VOCs in smoking area were higher than non-smoking area. These results suggested that the VOC levels were affected by various indoor characteristics and behavioral activity of occupants.

  • PDF

Study on the Ignition of Fallen Leaves by a Cigarette Butt (담뱃불에 의한 낙엽 착화에 대한 연구)

  • Kim, Dong-Hyun;Lee, Myung-Bo
    • Fire Science and Engineering
    • /
    • v.24 no.5
    • /
    • pp.39-49
    • /
    • 2010
  • In order to find out the environment vulnerable to cigarette fire in which smoldering fire grows into flame fire, a cigarette combustion test and numerical analysis were performed using fallen leaves of P. densiflora and Q. variabilis. Tests were repeated five times on 2,304 conditions with four cases of fuel moisture content, six cases of velocity, two cases of cigaret location against direction of the wind, three cases of cigaret location against fallen leaves, two species of thickness of cigaret, two cases of slope conditions and two cases of fragileness of fallen leaves. Cigaret fire's flammability to the fallen leaves was monitored by analyzing heat transfer process using CFD (Computational Fluid Dynamic) under the most optimal condition through an ignition test on 2,304 conditions. The result of a cigaret fire ignition test for fallen leaves, found ignition in 197 conditions out of 2,304 conditions representing 8.6% while 13 conditions representing approximately 0.6% saw ignition across five repeated tests. The result of CFD analysis, the temperature of the bottom of fallen leaves was reached on self-ignition and pilot-ignition temperature.