• Title/Summary/Keyword: Pilot Test

Search Result 1,476, Processing Time 0.027 seconds

A Pilot Plant Study of Industrial Wastewater Recycling Technology for Disc-Tube Membrane (DISC-TUBE MEMBRANE을 이용한 산업폐수 재활용 기술의 PILOT PLANT적 연구)

  • 김동일;한성욱;김호식;김인환
    • Journal of environmental and Sanitary engineering
    • /
    • v.12 no.3
    • /
    • pp.81-86
    • /
    • 1997
  • In case of Industrial Wastewater, It was various pollutions, high concentration and different physical, chemical properties each other in accordance with classification of wastewater. Therefore, after inquiring into the influence on the membrane of the dissolved pollutants, we should select the membrane of best efficient quality. As results of experiments on pilot plant test, optimum operating pressure for fouling removal was 34BAR, when continues operating was 34 BAR, recovery rate was 75% and permeate water flux was $32.9{\;}{\ell}/hr{\cdot}m^{2}$.

  • PDF

The Pilot Study of the structural design based on the Building Information Model(BIM) (Building Information Model(BIM) 기반의 건축 구조설계 Pilot Study)

  • Shin, Tae-Song;Cho, Young-Sang;Cheon, Jin-Ho;Eom, Jin-Up;Yang, Jong-Min
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2008.04a
    • /
    • pp.265-268
    • /
    • 2008
  • With application of IT convergence technique in AEC industry, it is currently conducted the research on the virtual construction system. This paper aims at the pilot study on the structural design based on BIM used in collaboration environment. The work scope of structural design includes the structural analysis model, structural detail model and analytic model and we focuse the research on the interoperability among them. It is partly utilized the transfer module supplied by software developer and partly developed here the interface module through API. This paper shows the interoperability process to pilot test and indicates the problems occurred in interface.

  • PDF

Evaluation of Pilot scale Coagulation system Design for CSOs treatment (CSOs 처리를 위한 실증규모 응집침전시스템의 설계평가)

  • Lee, Seung-Chul;Ha, Sung-Ryong
    • Journal of Wetlands Research
    • /
    • v.15 no.1
    • /
    • pp.1-8
    • /
    • 2013
  • A pilot scale coagulation system, which has a function of physicochemical treatment, was developed to treat Combined sewer overflows(CSOs). This coagulation system requires evaluation of optimum design factors whether it has reflected those of lab scale system, moreover, the pilot scale system can be evaluated differently according to the characteristics of influent CSOs even though it has reflected lab scale's design factors. We conducted an experiment using lab scale system that could treat $1m^3$ of CSOs in a day, and also pilot-scale system with $100m^3/day$ CSOs flowed into the Cheongju sewage treatment plant. Therefore the aim of this study is to evaluate a hydraulic similarity between the design factors of pilot scale and those of lab scale coagulation system, and to evaluate feasibility of the coagulation system for the CSOs treatment with optimum operation conditions. From the result of pilot-test, we drew the optimum operation factors of in line mixer and flocculator having similarities with those of lab scale system as well as the optimum coagulant dose. Finally we confirmed that the coagulation system has feasibility to treat the CSOs with high removal efficiency.

An Evaluation on the Result of Pilot Test for Soft Grounnd Improvement in Asan (아산지역에서의 연약지반개량을 위한 시험시공 결과에 대한 평가)

  • 이재원;김성인
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.03b
    • /
    • pp.615-622
    • /
    • 2000
  • This paper is relate to the result of pilot test in Asan. In order to evaluate the characteristics of behavior and deformation in Asan and to analyse the effect of soft ground treatment, preloading, two types of paper drain and pack drain were constructed in the ground. Settlement gauges, pressure meters, pressure cells and ground water gauges were monitored and also borings and piezoncone tests were performed. As a result of analyse, every vertical drained area was consolidated over 90% degree of consolidation but preloaded area was not reached to 90%.

  • PDF

Factor Analysis of Type I Osteoporosis and Evaluation on Tuna Bone Powder Compounds through Small Scale Pilot Study (I형 골다공증의 요인분석과 다랑어골분 복합제제의 pilot study를 통한 평가)

  • Chi Gyoo Yang;Kim Young Man
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.18 no.1
    • /
    • pp.93-100
    • /
    • 2004
  • This study was carried out for analyzing pathological and epidemiological factors of osteoporosis and doing pilot test using trial compounds of tuna bone and oriental herbs based on the factors. Osteoporosis is originated from osteoblast, osteoclast, organic and inorganic factors etc. Therefore the pathology of osteoporosis is not simple because the cytokine, growth factors and hormones of the components are various a lot. Taking a view of epidemiological factors of type I osteoporosis, ageㆍmenarcheㆍcholesterolㆍBMI etc. have definite relation to them. So we can approach to aging or consumptive disease in oriental medicine, specifically differential diagnosis of blood depletion with deficiency of qi, deficiency of kidney, deficiency of yin, bony weakness etc. And it should be considered together with rules for maintaining good health or habit concomitantly. Therefore IL1ㆍ6 or TNF αㆍβ are generally used as molecular biological index for osteoblast and osteoclast because the most important index is bone mineral density and strength, but the factors like collagen and noncollagen protein must be accounted as biomarkers. Trial compounds generally showed favorable effects on accompanying subjective symptoms of osteoporosis in the pilot test for menopausal woman. But if she didn't have specific symptoms of osteoporosis there wasn't any specific change. And osteocalcin was increased in case of being under standard level, but wasn't changed in case of normal level. Therefore these trial compounds can be used as a funcdonal diet for type I osteoporotic patients or preventive measures.

Holding Strength of Screws in Domestic Particleboard and Medium Density Fiberboard (I) - Optimum Pilot Hole Diameter - (국산 파티클보오드와 중밀도 섬유판의 나사못 유지력(I) - 최적 예비구멍 직경 -)

  • Lee, Phil-Woo;Park, Hee-Jun;Han, Yu-Soo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.19 no.3
    • /
    • pp.27-34
    • /
    • 1991
  • Screw withdrawal test was carried out on the face and edge of domestic particleboard and medium density fiberboard in order to evaluate optimum pilot hole diameter. The obtained results were as follows: 1. Maximum withdrawal strengths on the face and edge of particleboard were obtained with pilot hole diameters at about 50% of root diameters of screw. 2. Maximum withdrawal strength on the face and edge of medium density fiberboard were obtained with pilot hole diameters that were about 60% and 50% of root diameters of screw, respectively. 3. Withdrawal strength showed about 91% of maximum withdrawal strength when pilot holes were not pre bored at particleboard. but when pilot holes at 90% of root diameter of screw withdrawal strength showed about as 51.3% of maximum withdrawal strength. 4. Withdrawal strength showed about 88% of maximum strength when pilot holes were not used, but withdrawal strength indicated 55.4% of maximum strength in case of 90% of root diameters of screw. 5. Maximum withdrawal strength on the face of particleboard was about 70.5% higher than that of the edge, and however medium density fiberboard was about 19.6% higher than that of the edge.

  • PDF

A Study on the Evaluation of Human Alertness for Flight Safety (비행안전을 위한 조종사의 생체 활성도 평가에 관한 연구)

  • 최승호;이달호
    • Proceedings of the ESK Conference
    • /
    • 1998.04a
    • /
    • pp.167-172
    • /
    • 1998
  • Methods of evaluating the physiological activity of the living body are EEG, EOG, Heart rate, and Rectal temperature, etc. In the study of Hagiwara and Araki(1993), they found positive correlations among performance test, physiological measurement, and subjective feeling measurement. Human alertness of pilot directly influences on the flight performance that accomplishes a lot of vigilance task and procedure execution in flight. Accordingly, this paper deals with the quantitative and objective performance test based on tracking error and reaction time by means of the new computer test program into which the perception-motion system of human beings is applies. Throughout this experiment using performance thst, the results suggest that performance capability in state of sleep deprivation 2 hours and alcoholic 0.05 .apaprox. 0.06% in blood were more impaired than one in a normal state, and they further showed statistically significant differences between them, which were influenced by impairment factors of body regulation and pilot's grade. We also obtained the prediction value and the 95% confidence interval of tracking error and reaction time at the normal state for the purpose of distinguishing performance capability between the normal state and the abnormal state. And it is ecpected that the evaluation of human alertness using performance test will be applied to the quantitative assessment of an each pilot's realistic consciousness/attention, and will lead a flight commander to the accurate decision of mission approval prior to a flight.

  • PDF

Measurement and Evaluation of Optimum Salt Concentration in Usual Dishes for the Menu Suggestion (적염 섭취 식단 모델을 제시하기 위한 상용 음식의 최적 염미도 측정 및 적염 식단 모델)

  • 이혜상;이경신
    • Korean journal of food and cookery science
    • /
    • v.12 no.3
    • /
    • pp.305-311
    • /
    • 1996
  • This study was to seek menu model in usual dishes to guarantee the optimum salt intake considering the optimum gustation of salt surveyed on Korean adults. First, a pilot test was practiced using rice gruel to determine the criteria and a meaningful interval of salt concentration. Based on the criteria and interval so determined, a test was performed to seek the optimum gustation of salt concentration in usual diets. Subjectgroup for the above tests was university students living in Kyung-Book area. The results were as follows: 1. Mode value of the optimum gustation of salt was 0.5% and the received threshold difference of salt was 0.2% in the pilot test. 2. Mode values of the optimum gustation of salt in a la carte, soups and stews were lower than those of other side dishes. 3. But the portion size of a la carte, soups and stews is much larger than that of other side dishes, so that a la carte, soups and stews are sources of relatively larger amount of salt than other side dishes. 4. Considering the recommended optimum salt intake, it is desirable to reduce the amount of stock in soups and stews and to select fried food or salad more frequently.

  • PDF

A Study on Operating Condition of Test-Bed Plant using Membrane filtration of D Water Treatment Plant in Gwang-Ju (D정수장 정밀여과막 실증플랜트의 최적 운전조건 연구)

  • Yang, Hyung-Jae;Yi, Seung-Hoon;Moon, Kyung-Ran
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.3
    • /
    • pp.155-163
    • /
    • 2017
  • Membrane filtration has become more popular in drinking water treatment recently, since the filtration can control not only particulate matters but also pathogenic microorganisms such as giardia and cryptosporidium very effectively. Pilot-scale ($120m^3/d$ of treatment capacity) and test-bed ($25,000m^3/d$ of treatment capacity) microfiltration experiments were conducted to find optimum operating mode and the critical flux. Optimum operating mode of pilot-test was assessed as inflow 1.0 min, filtration 36.5 min, air backwash 0.9 min, backwash 1.0 min and outflow 1.0 min with 50 LMH ($L/min{\cdot}m3^$) of critical flux. Critical Flux was calculated to be $50L/m^2-h$ (within TMP 0.5 bar) based on the increase formula of the transmembrane pressure difference according to the change of time at Flux 20, 40, 56 and 62 LMH in pilot operation. Chemical cleaning was first acid washed twice, and alkali washing was performed secondarily, and a recovery rate of 95% was obtained in the test-bed plant. The results of operating under these appropriate conditions are as follows. Turbidity of treated water were 0.028, 0.024, 0.026 and 0.028 NTU in spring, summer, autumn and winter time, respectively. Microfiltration has superior treatment capability and performance characteristics in removing suspended solids and colloidal materials, which are the main cause of turbidity and important carrier of metal elements, and it has shown great potential in being an economically substitute to traditional processes (sand filtration).