Pilot Plant Scale Extraction and Concentration of Purple-Fleshed Sweet Potato Anthocyanin Pigment (자색고구마 anthocynin 색소의 대량추출 및 농축)

  • Rhim, Jong-Whan;Lee, Jang-Wook;Jo, Jae-Sun;Yeo, Kyeong-Mok
    • Korean Journal of Food Science and Technology
    • /
    • v.33 no.6
    • /
    • pp.808-811
    • /
    • 2001
  • Performance of pilot plant scale extraction and concentration of purple-fleshed sweet potato anthocyanin pigment was tested and the characteristics of pigment extracts and concentrates were investigated. Fifty kilograms of purple-fleshed sweet potato was extracted with 500 L of 1% citric acid in 20% ethanol. As a whole, extraction pattern of the large scale extraction was similar to that of the laboratory scale extraction. The extracted pigment solution was filtered twice with a bag filter and a winding type microfilter and the filtrate was concentrated by a large scale vacuum evaporator at $40^{\circ}C$ and 600 mmHg vac. The mean values of total optical density (TOD) of the extract and the concentrate were 6.53 and 120.45, respectively. Browning index (BI) and Degradation index (DI) of extract were 5.86 and 1.55 and those of concentrate were 5.89 and 1.56, respectively, which indicated that the pigments were not changed or degraded through the extraction and concentration process.

  • PDF

Comparison of anterior maxillary and mandibular alveolar parameters in African American and Caucasian women: A retrospective pilot study

  • Renaud, Lauren;Gandhi, Vaibhav;West, Cailynn;Gudhimella, Sudha;Janakiraman, Nandakumar
    • Imaging Science in Dentistry
    • /
    • v.51 no.2
    • /
    • pp.175-185
    • /
    • 2021
  • Purpose: The primary objective of this study was to analyze the thickness and height of alveolar bone around the maxillary and mandibular incisors. Additionally, this study aimed to compare bone parameters between Caucasian (CC) and African American (AA) female patients. Materials and Methods: In this retrospective pilot study, 50 female subjects(25 CC and 25 AA) were included. The inclusion criteria were AA or CC women between the ages of 18 and 50 with a normo-divergent facial pattern and Angle's class I, end-on class II, or mild class III malocclusion. The distance from the cementoenamel junction (CEJ) to the buccal and lingual alveolar crest; the alveolar ridge thickness at the mid-root and apex; and the buccal and lingual bone thickness at 3, 6, and 9mm from the CEJ were measured. Results: No significant difference was found (P>0.05) in the cortical bone thickness at 3mm, 6mm, or 9mm from the alveolar crest between CC and AA populations for most measurements. A significant difference in bone thickness was found (P<0.05) for the lingual surface of the central incisor, with maxillary bone thickness found to be higher than mandibular bone thickness. The measurements of lingual thickness were larger than those of buccal thickness for both races. Conclusion: There were no differences in maxillomandibular anterior alveolar bone measurements between normo-divergent adult AA and CC women, except for a few parameters at varying locations. However, future studies can be planned based the current pilot study data, which may provide valuable information.

A Pilot Study to Evaluate the Reliability of a Pattern Identification Tool for Benign Prostatic Hyperplasia and to Analyze Correlations between Pattern Identification Tools and International Prostate Symptom Score (IPSS) and Uroflowmetry (전립선비대증 변증도구의 신뢰도 평가 및 IPSS, 요속과의 상관관계에 대한 탐색적 연구)

  • Jeon, Cheon-hoo;Gu, Ji-hyang;Kang, Wee-chang;Jang, Eun-su;Lee, Eun-jung;Jung, In-chul;Cho, Chung-sik
    • The Journal of Internal Korean Medicine
    • /
    • v.41 no.6
    • /
    • pp.1052-1065
    • /
    • 2020
  • Objectives: To evaluate the reliability of a pattern identification tool for benign prostatic hyperplasia and to examine the relationship between pattern identification tool readings and IPSS and uroflowmetry. Methods: We analyzed 56 patients diagnosed with benign prostatic hyperplasia from December 27th, 2017 to December 26th, 2018 by two different Korean medical doctors and followed with a pattern identification tool and by IPSS and uroflowmetry. One week later, the patients were retested to analyze the reliability of the pattern identification tool, determined with the intraclass correlation coefficient (ICC) using the test-retest method. The correlation between IPSS and uroflowmetry was analyzed with the Pearson coefficient. Result: The reliability of the pattern identification tool for benign prostatic hyperplasia was evaluated as "poor agreement beyond chance" (ICC=0.349). The reliability of each pattern identification score was evaluated as "good" for Yang Deficiency of Kidney, Yin Deficiency of Kidney, Deficiency of Middle Qi, and Dampness-heat of Lower Energizer. The internal consistency was evaluated as "good" for Yang Deficiency of Kidney, Yin Deficiency of Kidney, and Dampness-heat of Lower Energizer, and as "excellent" for Deficiency of Middle Qi. The correlation between pattern identification and IPSS was evaluated as a "moderate positive correlation" for all pattern identifications. The average flow rate and maximum flow rate using uroflowmetry was evaluated with "moderate negative correlation" for Yang Deficiency of Kidney and Dampness-heat of Lower Energizer. Conclusion: The reliability of a pattern identification tool for benign prostatic hyperplasia was evaluated as "poor agreement beyond chance." Further research is needed.

Development and Evaluation of Model-based Predictive Control Algorithm for Effluent $NH_4-N$ in $A^2/O$ Process ($A^2/O$ 공정의 유출수 $NH_4-N$에 대한 모델기반 예측 제어 알고리즘 개발 및 평가)

  • Woo, Dae-Joon;Kim, Hyo-Soo;Kim, Ye-Jin;Cha, Jae-Hwan;Choi, Soo-Jung;Kim, Min-Soo;Kim, Chang-Won
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.1
    • /
    • pp.25-31
    • /
    • 2011
  • In this study, model-based $NH_4-N$ predictive control algorithm by using influent pattern was developed and evaluated for effective control application in $A^2/O$ process. A pilot-scale $A^2/O$process at S wastewater treatment plant in B city was selected. The behaviors of organic, nitrogen and phosphorous in the biological reactors were described by using the modified ASM3+Bio-P model. A one-dimensional double exponential function model was selected for modeling of the secondary settlers. The effluent $NH_4-N$ concentration on the next day was predicted according to model-based simulation by using influent pattern. After the objective effluent quality and simulation result were compared, the optimal operational condition which able to meet the objective effluent quality was deduced through repetitive simulation. Next the effluent $NH_4-N$ control schedule was generated by using the optimal operational condition and this control schedule on the next day was applied in pilot-scale $A^2/O$ process. DO concentration in aerobic reactor in predictive control algorithm was selected as the manipulated variable. Without control case and with control case were compared to confirm the control applicability and the study of the applied $NH_4-N$control schedule in summer and winter was performed to confirm the seasonal effect. In this result, the effluent $NH_4-N$concentration without control case was exceeded the objective effluent quality. However the effluent $NH_4-N$ concentration with control case was not exceeded the objective effluent quality both summer and winter season. As compared in case of without predictive control algorithm, in case of application of predictive control algorithm, the RPM of air blower was increased about 9.1%, however the effluent $NH_4-N$ concentration was decreased about 45.2%. Therefore it was concluded that the developed predictive control algorithm to the effluent $NH_4-N$ in this study was properly applied in a full-scale wastewater treatment process and was more efficient in aspect to stable effluent.

A Study on the Sleep pattern of normal neonates in Seoul and Kyungki area (서울.경기지역 신샌아의 수면/활동 양상에 관한 연구)

  • Kim, Il-Ok;Yang, Eun-Young;Lee, Ja-Hyung
    • Korean Parent-Child Health Journal
    • /
    • v.3 no.2
    • /
    • pp.41-48
    • /
    • 2000
  • The sleep is the most important problem for new parents. However, there were very rare the study about sleep of normal neonates and early infants in Korea. So we attempted pilot survey study of neonates' sleep pattern. The purpose of this study was to investigate the sleep pattern of normal neonates in Seoul and Kyungki area and to provide for basis for nursing intervention for parents of them. The subjects of this study were 37 normal full-term neonates of 2~3weeks of age who were visited by researcher or assistant at postpartum care unit, health care clinic, outpatient clinic located in Seoul and Kyungki area from April 20, 1999 to March 15, 2000. This study was descriptive survey study under the convenient sampling method. The instrument of this study was the NCASA translated by Korean Parent Child Health Academic Association. The collected data were coded as 1/4hour unit, and analyzed by MS Office Excel program. The result of this study were as followed: 1. The mean amount of total sleep was 15.1hours. The mean amount of daytime sleep was 9.5hours. The mean amount of nighttime sleep was 5.7 hours. The mean amount of longest sleep was 2.9hours. The mean amount of shortest sleep was 0.6hour. 2. The mean amount of total activity was 8.9hours. The mean amount of daytime activity was 6.5 hours. The mean amount of nighttime activity was 2.3hours. The frequency of feeding was 10.4 times a day. The frequency of daytime feeding was 7.3 times. The frequency of nighttime feeding was 3.1 times. It is suggested that various subjects and more data according to age, and comparative study among different cultures are needed for further study in the future.

  • PDF

Comparison of Particle Loading Characteristics onto Ceramic Candle Filters in Filtration System at Different Gas Inflow Pattern (가스 유입 방식에 따른 집진장치 내에서의 세라믹 캔들 필터로의 입자 부하 특성 비교)

  • Park, Seok-Joo;Lim, Jeong-Hwan;Lim, Kyeong-Soo
    • Korean Chemical Engineering Research
    • /
    • v.46 no.5
    • /
    • pp.983-987
    • /
    • 2008
  • Computational simulation has been performed to design optimally the filtration system for IGCC pilot plant. It was analyzed how the different inflow pattern influences the flow field and the particle behavior in a filter vessel. The particle loading onto the filter surface lowers significantly and decreases dramatically with particle size when the dusty gas flows into the filter vessel with a shroud tube through a tangential inlet setup tangentially on the vessel outer wall. However, the particle loading is considerably high when the dusty gas enters the filter vessel through a normal inlet setup vertically on the vessel top wall, and the decrease of the particle loading with particle size is not steeper compared with the tangential inflow pattern.

A Pilot Study for the Practical Usage of Traditional Korean Medicine Diagnostic Methods in Women Infertility (여성 불임환자에 대한 한의 진단도구 활용을 위한 기초연구)

  • Yoo, Jeong-Eun;Yoo, Dong-Youl
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.28 no.1
    • /
    • pp.102-112
    • /
    • 2015
  • Objectives: This study was performed to obtain reference data of traditional Korean medicine diagnostic methods for the practical usage in women infertility. Methods: The study involved 38 female patients of age 20-38 years that had diagnosed of infertility. All the subjects answered to pattern identification questionnaire and Questionnaire for the Sasang Constitution Classification (QSCC II). Pattern identification scores and constitution types have been analyzed with variables of infertility factors and age. Statistical analysis was performed by adopting descriptive and inferential tests. Results: In pattern identification questionnaire analysis, the patterns were observed in order of frequency: liver stasis; blood deficiency; kidney-yang deficiency; kidney-yin deficiency; damp-heat; blood stasis; and phlegm. The group, less than 35 years old, had the higher average score of liver stasis (p<0.05). Also, the group with tubal and peritoneal factors, had the higher average score of blood deficiency (p<0.05). In QSCC II analysis, So-yang type had the higher average score of liver stasis, kidney-yang deficiency, and kidney-yin deficiency. So-eum type had the higher average score of liver stasis, kidney-yang deficiency, kidney-yin deficiency, and blood deficiency. While, Tae-um type had the higher average score of liver stasis and phlegm. Conclusions: We would accumulate the clinical data for the practical usage of traditional Korean medicine diagnostic methods in women infertility.

Change of gait pattern of a patient with ataxic gait by cerebellar infarction (소뇌 경색 환자의 임상양상에 따른 보행의 변화)

  • Hong, Haejin;Choi, Sanho;Lee, Ilsuk;Oh, Jaegun;Sung, Kang-keyng;Lee, Sangkwan
    • The Journal of the Society of Stroke on Korean Medicine
    • /
    • v.14 no.1
    • /
    • pp.31-39
    • /
    • 2013
  • ■ Objectives The goal of this pilot study is to observe the change of gait pattern according to the clinical status in a patient with ataxic gait by cerebellar infarction. ■ Methods We measured the spatiotemporal gait parameters of a patient with ataxic gait four times, in which, first, the patient was not able to walk independently, second, able to walk independently, third, unable to walk independently by general tremor, and, last, able to walk independently after disappearing of general tremor. ■ Results When a patient with cerebellar ataxic gait was able to walk independently and the cerebellar tremor was disappeared, the change of gait pattern was that step and stride length decreased and total double support and stance phase increased. ■ Conclusion When different clinical characteristics were improved, the change of gait showed same pattern.

  • PDF

Effect of Optic pathway on the Proprioceptive Neuromuscular Facilitation (시각회로가 고유수용성신경근촉진법 치료에 미치는 효과)

  • Song, Myung-Soo;Yoon, Hee-Jong;Kim, Tae-Youl;Lee, Kyung-Ok
    • Journal of Korean Physical Therapy Science
    • /
    • v.5 no.4
    • /
    • pp.837-843
    • /
    • 1998
  • The purpose of this study was to examine the effect of optic pathway on human body during Proprioceptive Neuromuscular Facilitation(PNF) treatment. Specifically, it's intened to find out through electromyography(EMG), what kind on change occurred in a patient's muscle when the patient saw the motor direction or when the patient didn't. A pilot experiment Was made over the sophomores of Mokpo Science College the following findings were given; As an EMG was taken over three of muscles that worked during Flexion-Adduction-Ext. Rot., one of the PNF pattern, a patient showed relatively stronger muscle power while watching the movement with his eyes open than the same patient did with his eyes closed, and the disparity between the two cases Was statistically significant(P<0.05). In the pattern of Extension-Abduction-Int.Rot., a patient also showed relatively stronger muscle power while watching the movement than the same patient did without watching it, and the disparity between the two cases also were significant(P<0.05). As seen above, the effect of motor treatment, among physiotherapy methods seemed to be greater if a patient watched the motor direction during treatment, because it gave a stimulus to proprioception.

  • PDF

Influence of coal and air flow rate distribution on gasification characteristics in 200 t/d scale MHI coal gasifier (200 t/d급 MHI 석탄 가스화기의 석탄 및 공기 배분에 따른 가스화 특성 평가)

  • Doh, Yunyoung;Ye, Insoo;Kim, Bongkeun;Ryu, Changkook
    • 한국연소학회:학술대회논문집
    • /
    • 2015.12a
    • /
    • pp.93-96
    • /
    • 2015
  • Commercial coal gasifiers typically use entrained flow type reactors, but have unique features in terms of reactor shape, gasifying agent, coal feeding type, ash/slag discharge, and reaction stages. The MHI gasifier is characterized as air-blow dry-feed entrained reactor, which incorporates a short combustion stage at the bottom and a tall gasification stage above. This study investigates the flow and reaction characteristics inside a MHI gasifier by using computational fluid dynamics (CFD) in order to understand its design and operation features. For its pilot-scale system at 200 ton/day capacity, the distribution of coal and air supply between the two reaction stages was varied. It was found that the syngas composition and carbon conversion rate were not significantly influenced by the changes in the distribution of coal and air supply. However, the temperature, velocity and flow pattern changed sensitively to the changes in the distribution of coal and air supply. The results suggest that one key factor to determine the operational ranges of coal and air supply would be the temperature and flow pattern along the narrower wall between the two reaction stages.

  • PDF