• Title/Summary/Keyword: Piezoelectric characteristic

Search Result 175, Processing Time 0.025 seconds

Forced Vibration Analysis of 4 DOF system for Design of Slip-Stick Actuator (슬립-스틱 구동기 설계를 위한 4자유도 시스템 강제진동 해석)

  • Song, Myeong-Gyu;Hur, Young-Jun;Park, No-Cheol;Park, Young-Pil;Park, Kyoung-Su;Lim, Soo-Cheol;Park, Jae-Hyuk
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.214-215
    • /
    • 2009
  • The friction is inevitable and unpredictable phenomena, so most mechanical systems are designed to low friction effect by using bearings and lubricants. However, the slip-stick actuator applies the friction force to its movement. The slip-stick mechanism is applied the piezoelectric actuator to overcome short displacement. Fast response of piezoelectric actuator is also good characteristic for the slip-stick mechanism. However, the piezoelectric actuator with slip-stick mechanism isn't common, because its cost and driving voltage are too high. In this paper, a voice-coil actuator with slip-stick mechanism is introduced. The cost and the driving voltage of a voice-coil actuator are much less than the piezoelectric actuator. And a dynamic vibration amplifier is proposed to adjust the dynamic performance of the actuator. By the results of numerical analysis, the feasibility of a dynamic vibration amplifier is verified.

  • PDF

A Study on the Aluminum Wire Bondingby Using Ultrasonic Vibrator (초음파 진동자를 이용한 알루미늄 와이어 용접에 관한 연구)

  • 김희수;이건복
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1994.10a
    • /
    • pp.571-576
    • /
    • 1994
  • In recent years, ultrasonic has been widely applied in measurement and industrial fields and its application range has been expanded as a result of continuous research and development. Wire Bonding Machine, an instrument fabricating semi-conductor, makes use of ultrasonic bonding method. In order to improve the currently used wire bonding machine using ultrasonic energy, technical accumulation is needed steadily through development of exciting device of ultrasonic composed of piezoelectic vibrator and horn. This study investigates the design conditions affecting the dynamic characteristics through the theoretical and experimental analysis of piezoelectric vibrator and horn, The study conducts separately the system identification of piezoelectric vibrator in time domain and the modal analysis of horn in frequency domain. In theoretical model, the integrated modeling is conducted via a combination of dynamic identification of piezoelectric vibrator and theoretical analysis of horn. Hence comparison is made for theoretical and experimental results of the dynamic characteristics of the ultrasonic transducer composed of piezoelectric vibrator and horn. Form the results of this study we develop the design technique of ultrasonic transducer using dynamic characteristic analysis and propose the possibility of ultrasonic welding considering the optimal condition of the natural frequency and vibration mode of horn.

  • PDF

Exact solution of a thick walled functionally graded piezoelectric cylinder under mechanical, thermal and electrical loads in the magnetic field

  • Arefi, M.;Rahimi, G.H.;Khoshgoftar, M.J.
    • Smart Structures and Systems
    • /
    • v.9 no.5
    • /
    • pp.427-439
    • /
    • 2012
  • The present paper deals with the analytical solution of a functionally graded piezoelectric (FGP) cylinder in the magnetic field under mechanical, thermal and electrical loads. All mechanical, thermal and electrical properties except Poisson ratio can be varied continuously and gradually along the thickness direction of the cylinder based on a power function. The cylinder is assumed to be axisymmetric. Steady state heat transfer equation is solved by considering the appropriate boundary conditions. Using Maxwell electro dynamic equation and assumed magnetic field along the axis of the cylinder, Lorentz's force due to magnetic field is evaluated for non homogenous state. This force can be employed as a body force in the equilibrium equation. Equilibrium and Maxwell equations are two fundamental equations for analysis of the problem. Comprehensive solution of Maxwell equation is considered in the present paper for general states of non homogeneity. Solution of governing equations may be obtained using solution of the characteristic equation of the system. Achieved results indicate that with increasing the non homogenous index, different mechanical and electrical components present different behaviors along the thickness direction. FGP can control the distribution of the mechanical and electrical components in various structures with good precision. For intelligent properties of functionally graded piezoelectric materials, these materials can be used as an actuator, sensor or a component of piezo motor in electromechanical systems.

The Effect on Acoustic Band Characteristics of ZnO Piezoelectric Transducer according to Thickness of Counter Electrode Layers (하부전극층의 두께가 ZnO 압전변환기의 음향대역특성에 미치는 영향)

  • Park, Gi-Yub;Lee, Jong-Deok;Park, Soon-Tae
    • Journal of the Institute of Electronics Engineers of Korea TE
    • /
    • v.37 no.1
    • /
    • pp.18-26
    • /
    • 2000
  • In this paper, piezoelectric transducer was theoretically analyzed to fabricate high frequency piezoelectric transducer with broadband characteristics. Piezoelectric transducer have been fabricated with 3.825${\mu}m$ ZnO film on Pt/Sapphire(0001), and its appilicability of transducer was confirmed with analyzing theoretical and experimental frequency characteristic. The resonance frequency was detected at the frequency of 827.47MHz corresponding to the half-wavelength frequency of ZnO thin film. Insertion loss was almost -50dB. The minimum insertion loss agrees with simulation analysis.

  • PDF

A Study on High Performance Operation of Hybrid Energy Recovery Drive System for Piezoelectric Pump (피에조 펌프 구동용 에너지 회수형 하이브리드 구동장치 고성능 운전에 관한 연구)

  • Hong, Sun-Ki;Lee, Jung-Seop;Cho, Yong-Ho;Kim, Ki-Seok;Kang, Tae-Sam
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.10
    • /
    • pp.1426-1431
    • /
    • 2015
  • Piezoelectric pump can be considered as R-C load and it needs something special driver because the output voltage does not become 0 even though the applied voltage is 0 with common converter. This operating system consists of fly-back converter to increase the input voltage and energy recovery inverter to apply square voltage to the piezoelectric pump. The energy recovery inverter can charge and discharge the energy of capacitive load. In this paper, to enhance performance of the driver, a few elements or circuits are added and modified. To drive the inverter safely, current limit resister is added and adjusted the value to valance the charging and discharging current. In addition, a current limit inductor is added to the input side to limit the input current and enhance the efficiency. Inductor only may make oscillation and another resister is added parallel to the inductor to solve this problem. The converter and inveter are assembled to one board for compactness. The appropriateness is proved with simulation and experiments.

Flexible tactile sensor array for foot pressure mapping system in a biped robot

  • Chuang, Cheng-Hsin;Liou, Yi-Rong;Shieh, Ming-Yuan
    • Smart Structures and Systems
    • /
    • v.9 no.6
    • /
    • pp.535-547
    • /
    • 2012
  • Controlling the balance of motion in a context involving a biped robot navigating a rugged surface or a step is a difficult task. In the present study, a $3{\times}5$ flexible piezoelectric tactile sensor array is developed to provide a foot pressure map and zero moment point for a biped robot. We introduce an innovative concept involving structural electrodes on a piezoelectric film in order to improve the sensitivity. The tactile sensor consists of a polymer piezoelectric film, PVDF, between two patterned flexible print circuit substrates (FPC). Additionally, a silicon rubber bump-like structure is attached to the FPC and covered by a polydimethylsiloxane (PDMS) layer. Experimental results show that the output signal of the sensor exhibits a linear behavior within 0.2 N ~ 9 N, while its sensitivity is approximately 42 mV/N. According to the characteristic of the tactile sensor, the readout module is designed for an in-situ display of the pressure magnitudes and distribution within $3{\times}5$ taxels. Furthermore, the trajectory of the zero moment point (ZMP) can also be calculated by this program. Consequently, our tactile sensor module can provide the pressure map and ZMP information to the in-situ feedback to control the balance of moment for a biped robot.

Piezoelectric Transducer for Ultrasonic Flaw Detector with High Performance (고성능 초음파 결함탐상기를 위한 압전변환기)

  • Jung, Jun Hwan;Jun, Ho Ik;Kim, Hyun-Sik;Kang, Seog Geun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.7
    • /
    • pp.1645-1652
    • /
    • 2013
  • In this paper, a new piezoelectric transducer for high performance ultrasonic flaw detector used in non-destructive test (NDT) is implemented. Here, the goals for some major characteristics such as piezoelectric strain constant and electro-mechanical coupling factor are fixed in advanced. Then, the parameters obtained by finite element analysis (FEA) are exploited to design and implement the piezoelectric transducer. As a result of experiments using manufactured samples, it is proved that the new PZT ceramics satisfy the goals very well. It has much improved impedance characteristic at the resonant frequency and generation of ultrasonic signals. In addition, ultrasonic flaw detector with the new transducer provides increased flaw detecting gain than the conventional one. Thus, it is considered that the new flaw detector contributes significantly to improve reliability of the NDT.

Numerical Analysis of Ultrasonic Beam Profile Due to the Change of the Number of Piezoelectric Elements for Phased Array Transducer (Phased Array트랜스듀서에 있어서 구성 압전소자수의 변화에 따른 초음파 빔 전파 특성의 수치 해석)

  • Choi, Sang-Woo;Lee, Joon-Hyun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.19 no.3
    • /
    • pp.207-216
    • /
    • 1999
  • A phased array is a multi-element piezoelectric device whose elements are individually excited by electric pulses at programmed delay time. One of the advantages of using phased array in nondestructive evaluation (NDE) application over conventional ultrasonic transducers is their great maneuverability of ultrasonic beam. There are some parameters such as the number and the size of the piezoelectric elements and the inter-element spacing of the elements to design phased array transducer. In this study, the characteristic of ultrasonic beam for phased array transducer due to the variation of the number of elements has been simulated for ultrasonic SH-wave on the basis of Huygen's principle. Ultrasonic beam directivity and focusing due to the change of time delay of each element were discussed due to the change of the number of piezoelectric elements. It was found that ultrasonic beam was much more spreaded and hence its sound pressure was decreased as steering angle of ultrasonic beam was increased. In addition, the ability of ultrasonic bean focusing decreased gradually with the increase of focal length at the same piezoelectric elements. However, the ability of beam focusing was improved as the number of consisting elements was increased.

  • PDF

Finite Element Analysis for the Development of Bone Surgery Piezoelectric Ultrasonic Medical Device and its Experimental Verification (골수술용 압전형 초음파 의료기기 개발을 위한 유한요소해석 및 이의 실험적 검증)

  • Song, Tae-Ha;Lee, Jung-Ho;Choi, Jong Kyun;Lee, Hee Won
    • Journal of Biomedical Engineering Research
    • /
    • v.43 no.5
    • /
    • pp.319-330
    • /
    • 2022
  • In this study, the optimal driving frequency was derived through finite element analysis (FEA) to optimize the developed piezoelectric ultrasonic medical devices(PUMD) for bone surgery. The core of the PUMD is the piezoelectric ceramic (PZT), which is a vibrator that generates vibration energy. The piezoelectric ceramic shows the maximum current value with respect to the input voltage at the resonance frequency, which generates the maximum mechanical vibration. In the past, various studies have been conducted related to the analysis of PUMD, but most of the research so far has been limited to free vibration analysis. However, in order to derive the accurate resonant frequency, the initial stress generated by bolt tightening in the bolt-clamped Langevin type transducer (BLT) must be considered. In this study, after designing a PUMD, the driving performance according to the bolt tightening value was analyzed through FEA, and this was experimentally verified. First, the resonance mode and frequency response were confirmed through modal and harmonic analysis at 20-40 kHz, which is known as the optimal driving frequency band of PUMD for bone surgery. In addition, the design of the PUMD was confirmed by checking the mechanical behavior of the tip and the piezoelectric ceramic at the resonant frequency. Consequentially, the characteristic evaluation was performed, and it was confirmed that the resonant frequency result derived through the FEA was reasonable. Through this study, we presented a more rational FEA method than before for BLT transducers. We expect that this will shorten the time and cost of developing a PUMD, and will enable the development of more stable and high-quality products.