• Title/Summary/Keyword: Piezocone test

Search Result 88, Processing Time 0.021 seconds

Comparative Study of Dutch Cone and Piezocone Penetration Test on Soft Ground (연약지반에 대한 더치콘과 피에조콘 관입시험 비교 연구)

  • 원정윤;장병욱;우철웅;윤상묵
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.45 no.2
    • /
    • pp.96-106
    • /
    • 2003
  • 134 Dutch cone (mechanical cone) and 9 piezocone (electronic cone) penetration tests have been performed in the southwestern part of Korea. In general, Dutch cone results may be different from that of piezocone due to the difference in structure of the cones. 6 Dutch cone and piezocone test data which were obtained at the same point respectively, were analyzed and plotted in soil classification chart proposed by Robertson et. al.(1986, 1990). Cone factors of Dutch cone and piezocone test empirically have been determined using laboratory and field vane test results. Using this cone factors, it was shown that there was good correlation between shear strength estimated using cone resistance and that of laboratory test and field vane tests. It was found that there was a good correlation between cone resistance from Dutch cone and that from piezocone. Relationship formula was also suggested. Dutch cone test provides a useful means for stratigraphic profiling in large project and has some advantage over piezocone in particular situations, such as very soft clay ground and dredged area.

Comparative study of Dutchcone and piezocone test on soft ground (연약지반에 대한 기계식 및 전자식 콘관입시험 비교 연구)

  • 장병욱;김재현;김동범;윤상묵;원정윤
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.10a
    • /
    • pp.237-244
    • /
    • 2002
  • A comparative study of 134 mechanical (Dutch cone) and 9. electronic cone (Piezocone) penetration data from the southern part of Korea has been performed. In general, Dutch cone results may be different from piezocone results due to the difference in structure of the cones. Cone penetrometer test data were analyzed and plotted in soil classification chart proposed by Robertson et. al.(1986,1990) Cone factors of Dutch cone and piezocone test have empirically been determined using laboratory and field vane test results. Using this cone factors, it was shown that there was good correlation between shear strength estimated using cone resistance and that of laboratory test and field vane tests. It was found that there was a good correlation between cone resistance from Dutch cone and that from piezocone. Dutch cone test provides a useful means for stratigraphic profiling in large project and has some advantage over piezocone in particular situations, such as very soft clay ground and dredged area.

  • PDF

Determination of Consolidation Characteristics in Fine Soils Evaluated by Piezocone Tests (콘 관입시험을 이용한 연약지반 압밀특성 평가)

  • Lim, Beyong-Seock
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.02a
    • /
    • pp.42-58
    • /
    • 2000
  • 본 연구의 목적은 연약지반의 압밀계수 측정에 있어 Piezocone 관입시험을 이용할 때 관입시험자체의 정확성과 시험결과들에 미치는 여러 가지 지반공학적 영향요소들을 고려하려는데 있다. 본 연구의 연구실험방법으로는, Piezocone 관입을 위한 연약모형지반 조성을 위하여 초대형 Slurry Consolidometer에 Free Stress 상태의 Slurry를 45일간 압밀시킨 후 Automatic Computer Control Calibration Chamber (LSU/CALCHAS; Louisiana State University Calibration Chamber System)에 옮긴후 다시한번 압밀시키는 Two-Stage Consolidation Method를 사용하였다 동시에 연약모형지반내에 8개의 Piezometer를 설치하여 Piezocone 관입시 유발되는 지반 내에서의 과잉간극수압의 변환을 측정하였다. 총 25개의 Piezocone 시험중 4개는 Standard 10$\textrm{cm}^2$ Piezocone이고, 나머지 21개는 Miniature Piezocone이 사용되었다. 모형지반은 여러 가지 Boundary Condition들과 Stress Condition 그리고 Stress History등을 고려하여 조성되었다. 또한 Dissipation Test직후의 압밀특성을 확인하기 위하여 0.01초당 한 개이상의 실측점을 측정할 수 있는 Digital-Oscilloscope를 이용하였다. 특히 Dissipation Test, 즉시 Piezocone의 Filter Element에 잡히지 않는 과잉간극수압의 Initial Drop 존재에 관한 기존의 추측을 실제 실험치로 확인할 수 있었다.

  • PDF

Estimation of Compression Index in Soft Soils using Dissipation Test Results (소산실험 결과를 이용한 연약지반의 압축지수 추정)

  • Park, Young-Hwan;Kang, Beong-Joon;Lee, Jun-Hwan
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.03a
    • /
    • pp.1024-1029
    • /
    • 2008
  • In this study, new parameter related with compression index was derivated from piezocone test results. It is assumed that the consolidation coefficient obtained by piezocone test is concerned with the volume change during piezocone dissipation. Based on that assumption, new parameter in terms of consolidation coefficient from piezocone test was introduced. The new parameter from piezocone test and the compression index from laboratory consolidation test shows linear relationship.

  • PDF

Piezocone Factors of Korean Clayey Soils (국내 점성토 지반의 피에조콘 계수)

  • 장인성;이선재;정충기;김명모
    • Journal of the Korean Geotechnical Society
    • /
    • v.17 no.6
    • /
    • pp.15-24
    • /
    • 2001
  • In order to evaluate undrained shear strength of clayey soils using Piezocone Penetration Test (CPTu), piezoncone factor is utilized. Commonly, piezoncone factors determined by empirical basis were preferred, which were established by correlation between measurements of piezocone test and undrained strengths obtained from other shearing tests. However, previous studies on the empirical piezocone factors were site-specific and there have been no systematic investigations on the effect of both engineering characteristics of clayey soils and soil non-homogeneity on the piezocone factor. Accordingly, the direct application of the previous results to Korean clayey soils without verification may be inappropriate. In this study, empirical piezocone factors are evaluated by comparing 46 CPTu results of 10 test sites with undrained shear strength obtained from Field Vane Test (FVT) and laboratory triaxial tests. Their reliabilities are investigated by the comparison with the previous piezocone factors and the deviation of data distribution from the mean values. And the effects of referencing test methods and typical engineering characteristics of clayey soils such as overconsolidation ratio (OCR) and plastic Index (I$_{p}$) are examined. Because piezocone factors obtained for various soil conditions are widely distributed, it is not appropriate to use the mean value as a representative. Instead, it is recommended to apply the piezocone factors with OCR, which is found to be a major factor in deriving piezocone factor. The necessitated piezocone factors are presented.d.

  • PDF

Evaluation of Piezocone Factors Applicable to Soft Ground Around Siwha Lake by Statistical Analysis (시화호 주변 연약지반 피에조콘계수 산정에 관한 통계적 분석)

  • Chung, Jin-Hyuck;Park, Soo-Beom;Lee, Song
    • Journal of the Korean Geotechnical Society
    • /
    • v.24 no.4
    • /
    • pp.89-100
    • /
    • 2008
  • Applying graph and correlation developed in other countries to the domestic field has limits. Therefore, it is necessary that Piezocone factor should be determined by including ground characteristics obtained from various test results in the domestic site for better application. In this study, laboratory tests and field tests were performed to find the characteristics of soft ground which was widely distributed around Siwha lake. A comparative analysis of these tests with Piezocone penetration test was performed and the Piezocone factor was estimated by correlationship analysis of undrained shear strength and cone resistance. Also, an appropriate Piezocone factor in the study site was reestimated by utilizing statistical analysis method for deriving reliable result.

Undrained Shear Strength of Marine Clays of Shihwa Region Obtained from CPTu (CPTu로부터 구한 시화지구 해성점토의 비배수 전단강도)

  • Jang, In-Sung;Kim, Bum-Sang
    • Ocean and Polar Research
    • /
    • v.25 no.spc3
    • /
    • pp.353-360
    • /
    • 2003
  • Estimation of undrained shear strength $(S_u)$ of clayey soils from piezocone penetration test (CPTu), which has widely been known as one of very promising in situ test methods, requires piezocone factors. Empirical correlations are generally utilized to derive piezocone factors, but previous studies on the empirical piezocone factors are site-specific and in some cases need engineering characteristics, which should be obtained from additional laboratory tests. In this study, empirical cone factors were evaluated by comparing 6 CPTu results at Shihwa region in Korea with reference $S_u$ values obtained from field vane test (FVT). From previous CPTu results of other regions in Korea as well as the results herein, the correlations between piezocone factor, $N_{kT}$ and CPTu results were investigated and three simplified evaluation methods of $S_u$ using only CPTu results were presented. The $S_u$ values estimated by $(q_T-{\sigma}_v)/{\sigma}'_v$ method shows better matches with those obtained from laboratory tests for marine clays at Shihwa region.

Identification of ambient pore pressure and rigidity index from piezocone dissipation test (피에조콘 소산시험을 이용한 평형간극수압과 강성지수의 역해석)

  • 김영상
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.03a
    • /
    • pp.49-54
    • /
    • 2002
  • This paper describes a systematic way of simultaneously identifying the ambient pore pressure and the rigidity index (=G/s$\_$u/) of soil by applying an optimization technique to the piezocone dissipation test result. An ambient pore pressure and optimal rigidity index were determined by minimizing the differences between theoretical excess pore pressures developed by Randolph & Wroth(1979) and measured excess pore pressures from piezocone using optimization technique. The effectiveness of the proposed back-analysis method was examined against the well-documented performance of piezocone dissipation tests (Tanaka & Sakagami, 1989), from the viewpoints of proper determination of selected target parameters and saving of test duration. It is shown that the proposed back-analysis method can evaluate properly the ambient pore pressure and the rigidity index by using only the early phase of the dissipation test data. Also, it is shown that with the optimized rigidity index and ambient pore pressure the proposed back-analysis method permits the horizontal coefficient of consolidation to be identified rationally.

  • PDF

A Study on the Determination of Depth of Soft Ground by Cone Resistance (피조콘 관입저항치($q_c$)를 이용한 연약지반 심도결정에 관한 연구)

  • 신윤섭;김민철;김연정;김영웅
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2003.03a
    • /
    • pp.701-708
    • /
    • 2003
  • Recently, piezocone penetration test is frequently conformed in order to estimate the characteristics of soft ground with standard penetration test, generally used in the past. The soil characteristics, such as cone penetration resistance, friction resistence and excessive pore water pressure, can be evaluated continuously through the piezocone penetration test. In Incheon International Airport 2nd phase site preparation, standard penetration test and piezocone penetration test were used in order to increase the confidence for determination of soft ground depth. And the compressible layer was determined by the comparison between the preconsolidation pressure and the designed increase pressure. As the results, the relation between standard penetration test and piezocone penetration test shows q$_{c}$=(1.09~l.63)N at the soft ground, determined by 5/30 N value. And q$_{c}$=(1.21~l.98)N was shown at the point of compressible layer, evaluated by the preconsolidation pressure. These results were applied to determination for the depth of soft ground and to design the improvement for the soft clay.lay.

  • PDF