• 제목/요약/키워드: Piezo1

검색결과 208건 처리시간 0.016초

Mechanosensitive ion channels in apoptosis and ferroptosis: focusing on the role of Piezo1

  • Yong-Jae Kim;Jeongeun Hyun
    • BMB Reports
    • /
    • 제56권3호
    • /
    • pp.145-152
    • /
    • 2023
  • Mechanosensitive ion channels sense mechanical stimuli applied directly to the cellular membranes or indirectly through their tethered components, provoking cellular mechanoresponses. Among others, Piezo1 mechanosensitive ion channel is a relatively novel Ca2+-permeable channel that is primarily present in non-sensory tissues. Recent studies have demonstrated that Piezo1 plays an important role in Ca2+-dependent cell death, including apoptosis and ferroptosis, in the presence of mechanical stimuli. It has also been proven that cancer cells are sensitive to mechanical stresses due to higher expression levels of Piezo1 compared to normal cells. In this review, we discuss Piezo1-mediated cell death mechanisms and therapeutic strategies to inhibit or induce cell death by modulating the activity of Piezo1 with pharmacological drugs or mechanical perturbations induced by stretch and ultrasound.

바이패스 방식 피에조 인젝터의 피에조 적층 및 인가전압에 따른 연료분사 특성 연구 (A Study on Injection Characteristics of Piezo Injector with Bypass by Various Piezo Stack and Applied Voltage)

  • 조인수;김우택;이진욱
    • 한국분무공학회지
    • /
    • 제25권1호
    • /
    • pp.1-7
    • /
    • 2020
  • In the common rail fuel injection system, which is the core of diesel high efficiency and NOX reduction, injection strategies such as high pressure injection of fuel, accurate injection rate control, and multistage injection are important to increase fuel atomization. In this study, the bypass type piezo injector for the electronic control based common rail injection system applied to diesel fuel vehicle was studied. In particular, the injection rate and internal fuel flow characteristics of the high-pressure injector according to the piezo stacking number and applied voltage were analyzed by theoretical numerical method. When the applied voltage changes, it is determined that additional fuel flow through the bypass compensates for the reduced valve driving force due to the change in the driving voltage.

3개 구동방식(SI, PI, DPI)별 디젤HEV용 인젝터의 분무 특성 비교 (Comparison on Spray Characteristics of Diesel HEV Injectors for 3-different Driving Type (SI, PI, DPI))

  • 정명철;성기수;김상명;이진욱
    • 한국분무공학회지
    • /
    • 제19권1호
    • /
    • pp.9-14
    • /
    • 2014
  • Performance of DI diesel engine with high-pressure fuel injection equipment is directly related to its emission characteristics and fuel consumption. So, the electro-hydraulic injector for the common-rail injection system should be designed to meet the precise high fuel delivery control capability. Currently, most high pressure injector in use has a needle driven by the solenoid coil energy or the piezo actuator controlled by charge-discharge of output pulse current. In this study, macroscopic spray approaching method was applied under constant volume chamber to research the performance of three different injectors : solenoid, indirect-acting piezo and direct-acting piezo type for CR direct-injection. LED back illumination for Mie scattering was applied on the liquid spray visible of direct-acting piezo injector, including hydraulic-servo type solenoid and piezo-driven injectors. As main results, we found that a direct-acting piezo injector had better a spray tip penetration than hydraulic-servo injectors in spray visualization.

피에죠 엑츄에이터를 이용한 나노 구동 제어기 설계 (Design of Controller Using the Piezo Actuator)

  • 유상훈;이충우;서상민;정정주;김대용
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2003년도 하계종합학술대회 논문집 V
    • /
    • pp.2811-2814
    • /
    • 2003
  • 본 논문에서는 Sub-nano 수준의 위치정밀도와 분해능을 갖는 Piezo actuator 의 제어기 설계를 목적으로 하였다. 이산 시간 상태 공간에서의 Piezo actuator를 이용한 1 축 스테이지 드라이브 시스템 SISO 제어기를 설계하였다. Piezo actuator 의 소재 자체의 특성으로는 Hysteresis 가 있으며, 이는 정상상태에서 Piezo actuator 의 위치 오차를 발생하는 주요 원인이 된다. 제어기의 설계는 극점 배치 방법을 기본으로 하여 Hysteresis 에 대한 보상을 목적으로 적분제어방식과 외란 추정기를 각각 적용하였다. 모의실험을 통하여 제어기의 설계 및 시뮬레이션 하였으며, Hysteresis 에 대한 보상이 이루어짐을 보았고, 실험을 통하여 이를 증명하였다.

  • PDF

LIPUS Promotes Endothelial Differentiation and Angiogenesis of Periodontal Ligament Stem Cells by Activating Piezo1

  • Rui Hu;Zheng-yan Yang;Yue-heng Li;Zhi Zhou
    • International Journal of Stem Cells
    • /
    • 제15권4호
    • /
    • pp.372-383
    • /
    • 2022
  • Background and Objectives: Low-intensity pulsed ultrasound (LIPUS) promotes differentiation and regulates biological functions of various stem cells, but its effect on the endothelial differentiation of periodontal ligament stem cells (PDLSCs) is unclear. This study investigated the effect of LIPUS on endothelial differentiation and angiogenesis in PDLSCs and the role of the mechanically sensitive ion channel Piezo1 in this process. Methods and Results: PDLSCs obtained from healthy people were used for endothelial induction, and 10 ㎍/ml lipopolysaccharide (LPS) was used to simulate the inflammatory state. The induced cells were treated with LIPUS (50 mW/cm2, 1.5 MHz) to study its effect on the endothelial differentiation of PDLSCs and the tube formation of differentiated cells. PCR, flow cytometry, immunofluorescence, and Matrigel tube formation assays were used to detect the differentiation and tube formation of PDLSCs. GsMTx4 was used to inhibit the expression of Piezo1, and the role of the Piezo1 pathway in the endothelial differentiation and microvascular formation of PDLSCs after LIPUS treatment was studied. The data showed that LIPUS increased endothelial differentiation and angiogenesis in PDLSCs under inflammatory or noninflammatory conditions. The use of an inhibitor weakened the effect of LIPUS. Conclusions: This study demonstrated that LIPUS can activate the expression of Piezo1 and promote the endothelial differentiation and microvascular formation of PDLSCs.

CRDI 디젤엔진의 피에조 인젝터 불량에 따른 파형 분석에 관한 실험적 연구 (An Experimental Study on the Waveform Analysis According to Troubles of Piezo Injector of CRDI Diesel Engine)

  • 유종식;김철수
    • 한국기계기술학회지
    • /
    • 제20권6호
    • /
    • pp.783-789
    • /
    • 2018
  • This paper investigates the relationship of voltage and current waveform between normal piezo injector and deterioration abnormal piezo injector. The experimental methods using Pico oscilloscope and GDS scan tool are employed to measure current and voltage waveform and fuel pressure of piezo injector. The experiment is carried out during no-load condition. A summary of the important results are as follows. 1) In case of normal injector, the fluctuation of duration time of piezo injector was linearly and regularly decreased with increasing engine speed, but the that of deterioration piezo injector was irregularly decreased with increasing engine speed. 2) In main injection, the peak value of the current waveform of abnormal injector was larger than that of normal injector, the duration time of deteriorated abnormal injector was less than that of normal injector at 800rpm and 1500rpm, but the duration time of deteriorated abnormal injector was larger than that of normal injector at 2000rpm and 3000rpm. This irregularity appears to be caused by the deterioration of the injector.

Piezo 압전 결정체에서의 표면탄성파 증폭에 관한 연구 (A Study on Surface Acoustic-Wave Amplfication in Piezo-electric Crystals)

  • 이윤현
    • 한국통신학회논문지
    • /
    • 제6권1호
    • /
    • pp.51-57
    • /
    • 1981
  • 半導'||'&'||'#20307;內에서 運動하는 carrier는 Piezo 壓電物質을 進行하는 彈性波에 利得이나 損失을 줄 수 있게 된다. 本 論文에서는 半導 film에서의 drifting carrier와 Piezo 壓電 基板上을 進行하는 Rayleigh Wave間의 相互作用의 表面彈性波 增幅을 論하였다. Piezo 壓電媒質에서 表面波 의 電磁的 境界條件이 表面波 速度에 미치는 影響에 대한 式을 求하였다. 增幅에 필요한 bunching 電子 電子 散에 의해 抑制되므로 높은 周波數에서 利得의 低下를 招來하나 적당한 壓電 物質일 경우 超高周波 領域에서도 상당한 增幅이 기대됨을 알 수 있다.

  • PDF

AMESim기반 피에조 인젝터용 해석모델의 민감도 특성 해석 (Analysis of Sensitivity Characteristics with AMESim Model for Piezo Injector)

  • 조인수;권지원;이진욱
    • 한국자동차공학회논문집
    • /
    • 제21권2호
    • /
    • pp.17-25
    • /
    • 2013
  • Performance of DI diesel engine with high fuel injection method is directly related to the emission characteristics and fuel consumption. At present, diesel injection system with piezo element is replacing conventional solenoid type due to their faster electro-mechanical properties. In this study, it was investigated the sensitivity characteristics regarding internal hydraulic modeling based on the AMESim environment of piezo-driven injector The analytic parameter for this study defined such as In/Out orifice, injection hole's diameter and driven voltage on piezo stack. As the results, it was shown that these parameter influence on a fast response characteristics of piezo-driven injector. Also we found fuel pressure recovery time is faster about 0.1 ms due to larger IN orifice diameter. And larger OUT orifice diameter occurs maximum pressure drop with faster its timing of about 0.2 ms.

Low-Voltage Current-Sensing CMOS Interface Circuit for Piezo-Resistive Pressure Sensor

  • Thanachayanont, Apinunt;Sangtong, Suttisak
    • ETRI Journal
    • /
    • 제29권1호
    • /
    • pp.70-78
    • /
    • 2007
  • A new low-voltage CMOS interface circuit with digital output for piezo-resistive transducer is proposed. An input current sensing configuration is used to detect change in piezo-resistance due to applied pressure and to allow low-voltage circuit operation. A simple 1-bit first-order delta-sigma modulator is used to produce an output digital bitstream. The proposed interface circuit is realized in a 0.35 ${\mu}m$ CMOS technology and draws less than 200 ${\mu}A$ from a single 1.5 V power supply voltage. Simulation results show that the circuit can achieve an equivalent output resolution of 9.67 bits with less than 0.23% non-linearity error.

  • PDF

Investigations on state estimation of smart structure systems

  • Arunshankar, J.
    • Smart Structures and Systems
    • /
    • 제25권1호
    • /
    • pp.37-45
    • /
    • 2020
  • This paper aims at enlightening the properties, computational and implementation issues related to Kalman filter based state estimation algorithms and sliding mode observers, by applying them for estimating the states of a smart structure system. The Kalman based estimators considered in this work are Kalman filter and information filter and, the sliding mode observers considered are Utkin observer and higher order sliding mode observer. A fourth order linear time invariant model of a piezo actuated beam is used in this work. This structure is embedded with four number of piezo patches, of which two act as sensors, one as disturbance actuator and the other as control actuator. The performance of the state estimation algorithms is evaluated through simulation, for the first two vibrating modes of the piezo actuated structure, when the structure is maintained at first mode and second mode resonance.