• Title/Summary/Keyword: Piezo Vibrator

Search Result 12, Processing Time 0.029 seconds

Enhancement of Oxygen Transfer Efficiency Using Vibrating lung Assist Device in In-Vitro Fluid Flow (In-vitro 유동장에서 진동형 폐 보조장치를 이용한 산소전달 효율의 향상)

  • 권대규;김기범;이삼철;정경락;이성철
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1332-1335
    • /
    • 2003
  • This paper presents the enhancement of oxygen transfer efficiency using the vibrating intravascular lung assist device (VIVLAD) in in-vitro experiments for patients having chronic respiratory problems. The test section was a cylinder duct with the inner diameter of 30 mm. The flow rate was controlled by the pump and monitored by a built-in flow meter. The vibration apparatus was composed of a piezo-vibrator, a function generator. and a power amplifier. The direction of vibration was radial to the fluid flow. Gas flow rates of up to 6 l/min through the 120-cm-Jong hollow fibers have been achieved by exciting a piezo-vibrator. The output of PVDF sensor were investigated by various frequencies in VIVLAD. The experimental results showed that VIVLAD would be enhance oxygen transfer efficiency.

  • PDF

Narrative Review on the Mechanism of Whidam's Vibrator Sugi Therapy (휘담식 진동기 수기요법의 기전에 대한 서술적 고찰)

  • Hun Mo Ahn;Dae Sung Jung;Han Joo Kang
    • Journal of Korean Medical Ki-Gong Academy
    • /
    • v.22 no.1
    • /
    • pp.1-27
    • /
    • 2023
  • Objective : This paper provides a narrative review of the research literature on the neurophysiological and neurochemical mechanisms of local vibration while studying the treatment principles and mechanisms of Whidam's vibrator Sugi therapy. Methods : Searches related to vibration therapy research were conducted in PUBMED using "Vibration", "Whole Body Vibration", "Localized Vibration", and "Focal Vibration". The Conditions were limited to review and systematic review. Results : Roberto Casale's paper was selected as an inquiry task and reviewed critically and narratively by referring to other papers. The stimulation process of local vibration (LV) was broadly classified into receptor transmission (pain reception phase), ascending sensory pathway to the spinal cord (segmental phase), and action of the cortex and subcortical structures (systemic control phase) according to the pain pathway. In addition, the role of C-tactile mechanoreceptors, changes in neurotransmitters and neurohormones, LV stimulation below perception threshold (lower threshold), pain control and kinesiologic illusions were specially addressed. In addition, the expression and function of Piezo Channels were added to supplement the human pain and tactile sensing mechanism. Conclusions : LV exerts pain control mechanisms through different interactions that can interfere with pain transmission and pain perception. Since LV provides sufficient neurophysiological reasons for clinical application, it is necessary to expand the use of Whidam's vibrator Sugi therapy to a wider range of clinical applications.

A Study on the Energy Harvesting Using Piezoelectric Material (압전 소자를 이용한 에너지 회수에 관한 연구)

  • Park, Jong-Soo;Lee, Young-Il;Nam, Yoon-Su
    • Journal of Industrial Technology
    • /
    • v.25 no.B
    • /
    • pp.141-147
    • /
    • 2005
  • A target of this paper is to get some elementary experimental data on the energy harvesting using a piezoelectric material. A THUNDER series piezo material (TH7-R), which has been developed by NASA engineer is selected for this study. In order to provide a mechanical energy to the piezoelectric material, a mechanical motion vibrator and its driving electronics are designed. Using a simple PWM control, the excitation frequency of vibrating mechanical motion is varied. The generated electric power as a function of the excitation frequency is monitored and analyzed. This initial experiment shows a possible energy source using a piezoelectric material for the application to low-power consumed small electronic devices such as RFID, MEMS, and etc.

  • PDF

Design Method for Ultrasonic Transducer to Bonding with Dissimilar Materials (이종재료 접합을 위한 초음파 진동자 설계)

  • Jeong, An-Mok;Kim, Cheol-Ho
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.22 no.1
    • /
    • pp.3-8
    • /
    • 2012
  • In an attempt to improve adhesion strength between glass and metal due to use of Pb-free solder as a sealant between glass and metal in the manufacturing process of vacuum insulation window glass to maintain the vacuum volume, ultrasonic energy is often applied during the process of Pb-free sealing. In this study, we propose an ultrasonic vibrator with a 4 mm end tip radius which performs resonance frequency of 60 kHz and 14 um or higher vibration displacement. A frequency variation due to applied pressure on piezo disks, which was excluded in the computer simulation, was verified experimentally, and we have demonstrated a 17 um vibration displacement at 50 V input through the performance test of a vibrator constructed with our specification.

Lambda shape multiway moving ultrasonic linear motor (람다형 다방향 초음파 선형 모터)

  • Do, Young-Soo;Nam, Hyo-Duk;Kim, Young-Duk
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.263-265
    • /
    • 2007
  • An ultrasonic linear motor using lambda shape vibrators has been designed and fabricated. The multiway ultrasonic motors mainly consist of an lambda shape ultrasonic vibrator which generates elliptical motions in beat. The lambda shape ultrasonic linear motor use longitudinal and bending vibration mode. In order to high precision motion control and multiway moving, piezoceramics were adhered to lambda shape brass elastic material. The finite element method was used to optimize dimension of ultrasonic vibrator and direction of vibratory displacement. As a result of estimating the characteristics of the ultrasonic linear motor, The results have shown that the lambda shape ultrasonic linear motor can be moved multiwav by using the phase control. Close agreement between the FEM results and experimental results obtained for the lambda shape ultrasonic linear motor.

  • PDF

Characteristics of Micro-Machining Using Two-Dimensional Tool Vibration

  • Ahn, Jung-Hwan;Lim, Han-Seok;Son, Seong-Min
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.2 no.3
    • /
    • pp.41-46
    • /
    • 2001
  • This paper discusses the feasibility of improving micro-machining accuracy by using two-dimensional(2-D) vibration cutting. Vibration cutting is generated by two piezo actuators arranged orthogonally : one is actuated by a sine curve voltage input, and the other is actuated by a phase-shifted sine curve voltage. A tool attached to the vibrator oscillates in a 2-D elliptical motion, depending on the frequencies, amplitudes, and the phase shifts of two input signals and the workpiece feedrate. Along the elliptical tool locus, cutting is done in the lower part, and non-cutting is done in the upper part. By this way a unique feature of 2-D vibration cutting, that is, air lubrication between a tool and chips, is caused. Another unique feature of 2-D vibration cutting was experimentally verified, that is, some negative thrust force occurs as the direction of chip movement on a tool rake face is reversed. Those features not only help chips flow smoothly and continuously but also reduce cutting force, which results in a higher quality machined surface. Through tool path simulations and experiments under several micro-machining conditions, the 2-D vibration cutting, compared to conventional cutting, was found to result in a great decrease in the cutting force, a much smoother surface, and much less burr.

  • PDF

Pin-Type Vibrotactile Display (핀형 진동촉각 출력장치)

  • Back, Jong-Won;Choi, Dai-Sung;Jang, Tae-Jeong
    • 한국HCI학회:학술대회논문집
    • /
    • 2006.02a
    • /
    • pp.463-466
    • /
    • 2006
  • 최근 전자기기에서 시각 및 청각과 함께 촉각 디스플레이가 정보를 출력하는 중요한 수단으로 부각되고 있다. 본 논문에서는 촉각 정보 출력을 위한 소형진동촉각(vibrotactile) 디스플레이 모듈을 개발하였다. 개발한 모듈은 주파수와 진폭을 독립적으로 조절할 수 있으며 핀이 직접 피부에 자극을 주기 때문에 몸체 전체가 떨리는 기존의 진동모터보다 정밀하고 다양한 촉각 표현을 할 수 있다. 또한 고전압을 이용하는 Piezo 방식과 달리 낮은 전력으로 동작이 가능하여 휴대장치에 직접 장착할 수 있는 장점을 가지고 있다.

  • PDF

Analysis of Linear-type Ultrasonic Motor Using A Finite Element Method (유한요소해석 프로그램에 의한 리니어 초음파 모터의 변위량 해석)

  • 이동준;임태빈;강성택;김영욱;임기조
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.06a
    • /
    • pp.33-36
    • /
    • 1998
  • This paper is a study on a linear ultrasonic motor with a first longitudinal$(L_1)$ and fourth bending $(B_4)$ double-mode rectangular plate. The stator vibrator is composed of an elastic material plate and of a piezo-ceramic element having a motion by electrical excitation. Each strain vector differs by $90^{\circ}$ generate travelling wave with the elliptical displacement motion of a point on the surface. To magnify displacement of longitudinal direction in elliptical displacement motion, the motor has a mechanism of the.displacement enlargement. In this paper, the vibration shape of the stator is simulated using the finite element method. A detailed model considered of the piezoelectric effect and of the exact geometry of the stator is used to calculate the displacement. The position of displacement mechanism is decided by the maximum displacement.

  • PDF

구동회로에 따른 박형 초음파모터의 동작특성

  • Jeong, Seong-Su;Jeong, Hyeon-Ho;Park, Min-Ho;Park, Tae-Gon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.109-109
    • /
    • 2009
  • This paper represented driving characteristic of a thin-type ultrasonic motor by fabricating and utilizing two kinds of drivers which could generate sinusoidal wave, square wave, respectively. A thin brass plate was used as a cross shaped vibrator and sixteen ceramic plates were attached on upper and bottom side of the brass plate. From the thin stator, elliptical displacements of the four contact tips were obtained. Speed, torque, and current were measured by applying sinusoidal waves through driving equipment such as function generator, power amplifier: to measure characteristic of the motor. As a result, the speed and the torque changed linearly at either driving frequency of 88.6 ~ 87.6[kHz] or voltage of 24~36[V]. Two-drivers which generate sinusoidal waves and square waves were designed respectively, and then were compared through some experiments in order to be put to practical use. In conclusion, the drivers had similar characteristic of speed-torque at similar frequency and voltage. It was able to control the motor linearly by using the driver generating square wave among two-drivers. Besides, it also was possible to make the drivers smaller.

  • PDF

Optimal Design of Thin Type Ultrasonic Motor (박형 초음파모터의 최적 설계)

  • Jeong, Seong-Su;Jun, Ho-Ik;Park, Tae-Gone
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.4
    • /
    • pp.335-340
    • /
    • 2008
  • In this study, novel structured thin ultrasonic rotary motor has been proposed. Ultrasonic motors are based on an elliptical motion on the surface of elastic body. Thin brass plate was used as a cross shaped vibrator and eight ceramic plates were attached on upper side and bottom side of the brass plate. From the thin stator, elliptical displacements of the four contact tips were obtained. To find the optimal size of the stator, motions of the motors were simulated using ATILA by changing length, width and thickness of the ceramics. The stators had commonly three resonance peaks and contact tips of the stator moved on tangential or normal trajectories at these resonance peaks. The maximum displacements at the resonance peaks were compared. As results, maximum displacements of the contact tips were obtained at the length of 16 mm, width of 6 mm and thickness of 0.4 mm. Changes of the resonance frequencies were inversely proportional to the length of ceramic and proportional to the width of ceramic. The motor was fabricated by using the designed stator. And, the characteristics of the motor were compared with the simulated results. When the motor was fabricated with these results, speed fo 935 rpm was obtained by input voltage of 25 Vrms at 93.5 kHz.