• 제목/요약/키워드: Pickup coil

검색결과 61건 처리시간 0.023초

신 자기회로가 적용된 광픽업 액추에이터의 동특성 (Dynamic characteristics of optical pickup actuator with a newly designed electromagnetic circuit)

  • 박관우;김재은;정제현;이경택;고의석;민병훈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 추계학술대회논문집
    • /
    • pp.512-514
    • /
    • 2008
  • In this paper, a new electromagnetic circuit is proposed for an optical pickup actuator with high sensitivity. Contrary to those of conventional actuators, the proposed circuit has two focusing coils which are diagonally placed at the front and rear of a moving part. The configuration which makes the effective length of the focusing coil longer and the moving part lighter, is helpful in increasing the sensitivity of the actuator. However, the asymmetry of the moving part by two focusing coils causes flexible node vibrations in quite low frequency range. This paper shows that the design modification of the moving part for the reconfiguration of mass moment of inertia can reduce the mode vibrations.

  • PDF

유연디스크용 가동 코일형 광 픽업 엑추에이터 개발 (Design of Moving Coil Type Optical Pickup Actuator for Flexible Disk)

  • 김윤기;송명규;이동주;박노철;박영필
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 추계학술대회논문집
    • /
    • pp.479-483
    • /
    • 2006
  • As high-definition television(HDTV) broadcasting were generalized, there have been many researches and developments about large storage capacity and fast data transfer rate in optical disk drives(ODD). Pickup actuators must have high flexible mode frequencies and gain margins. Flexible modes are caused by the flexibility of moving parts in the actuator and a servo bandwidth is limited by them. As a result, the system becomes unstable for high-speed operations in high density reading and recording. In this paper, we suggest improved modeling method that considers the bonding layer. And, flexible mode frequency of actuator is improved by Design of Experiment of lens holder. Magnet circuit is designed considering the relation with moving part. Through improving yoke design, the magnetic flux is changed and DC tilt is reduced. Consequently, we designed actuator which has high flexible mode frequency and gain margins.

  • PDF

저잡음 심자도측정시스템 개발을 위한 고온초전도 SQUID 센서의 제작 (Fabrication of HTS SQUID Sensors for the Application to a High S/N Ratio Magnetocardiograph System)

  • 김인선;유권규;박용기
    • Progress in Superconductivity
    • /
    • 제6권1호
    • /
    • pp.19-23
    • /
    • 2004
  • YBCO do superconducting quantum interference device (SQUID) magnetometers based on bicrystal Josephson junctions on 10 mm ${\times}$ 10 mm $SrTiO_3$ substrates have been fabricated. The pickup coil of the device was designed to have 16 parallel loops with 50-fm-wide lines. We could obtain optimised direct coupled YBCO SQUID magnetometer design with field sensitivity $B_{N}$ $\Phi$/ of $4.5 nT/\Phi_{0}$ and magnetic field noise $B_{N}$ of about $22 fT/Hz^{1}$2/ with an I/f corner frequency of 2 Hz measured inside a magnetically shielded room. Preliminary results of magnetocardiograph measurement using the HTS SQUID magnetometers show signal to noise ratio of about 110, which is comparable to the quality of a commercial MCG system based on Nb-SQUIDs.

  • PDF

희토류 영구자석의 자성측정을 위한 고감도 펄스마그네토미터 (A High Precision Pulsed Field Magnetometer for Magnetic Properties Measurements of Rare Earth Magnets)

  • 김윤배
    • 한국자기학회지
    • /
    • 제15권4호
    • /
    • pp.250-255
    • /
    • 2005
  • 8 MA/m급 펄스자석과 픽업코일, 아날로그 전자적분기, 계수기록형 오실로스코우프, 퍼스널컴퓨터 등을 이용하여 펄스고자장하에서 자성을 정밀 측정할 수 있는 펄스마그네토미터를 구성하였다. 픽업코일은 작은 공간에서 정밀측정이 가능하도록 3-축보상원리를 채용하여 제작하였으며 펄스자장에 대한 신호 보상은 $10^{-6}$수준이었고 적분기와 오실로스코우프를 거친 후의 최종 자기모멘트의 측정감도는 $5{\cdot}10^{-7}\;Am^2$이었다. 본 실험을 통하여 구성된 펄스마스네토미터는 지름 $3\;mm{\phi}$, 이하의 소형 및 박막형 희토류 영구자석의 특성평가에 적합하였다.

NiZn 페라이트코어를 이용하여 제작한 직교형 플럭스게이트 센서의 출력에 미치는 바이어스전류의 영향 (DC Bias Current Influence to the Sensitivity of Orthogonal Fluxgate Sensor Fabricated with NiZn Ferrite Core)

  • 신광호
    • 한국자기학회지
    • /
    • 제23권3호
    • /
    • pp.94-97
    • /
    • 2013
  • 본 연구에서는 원통형 페라이트 코어와 페라이트코어를 관통하는 구리선, 그리고 검출 코일을 이용하여서 직교형 플럭스게이트 센서를 제작하고, 직류 바이어스 전류가 출력 감도에 미치는 영향에 대해서 조사하였다. 제작한 직교형 플럭스게이트 센서의 출력 및 감도는 구동주파수에 의존하였으며, 이는 검출코일 임피던스의 주파수특성이 나타내는 경향과 유사하였다. 직류 바이어스 전류가 교류 구동전류의 크기에 비해서 대략 50% 이상일 때 출력감도가 최대가 되었으며, 그 보다 큰 직류 바이어스 전류에 의해서는 출력감도가 포화되는 경향을 나타내었다.

유연디스크용 가동 코일형 광 픽업 엑추에이터 개발 (Design of Moving Coil Type Optical Pickup Actuator for Flexible Disk System)

  • 김윤기;송명규;이동주;유정훈;박노철;박영필
    • 정보저장시스템학회논문집
    • /
    • 제2권4호
    • /
    • pp.240-244
    • /
    • 2006
  • As high-definition television(HDTV) broadcasting becoming more generalized, there have been many researches and developments about a large storage capacity and a fast data transfer rate in optical disk drives (ODD). Pickup actuators must have high flexible mode frequencies and large gain margins. Flexible modes are caused by the flexibility of moving parts in the actuator and a servo bandwidth is limited by them. As a result, the system becomes unstable for high-speed operations in high density reading and recording. In this paper, we suggest improved modeling method in considering of the bonding layer. And, the flexible mode frequency of actuator is improved by Design of Experiments of lens holder. The Magnet circuit is designed considering the relation with the moving part. Through improving the yoke design, the magnetic flux is changed and the DC tilt is reduced. Consequently, we designed an actuator which has a high flexible mode frequency and a large gain margins.

  • PDF

Ultra Low Field Sensor Using GMI Effect in NiFe/Cu Wires

  • Kollu, Pratap;Kim, Doung-Young;Kim, Cheol-Gi
    • Journal of Magnetics
    • /
    • 제12권1호
    • /
    • pp.35-39
    • /
    • 2007
  • A highly sensitive magnetic sensor using the Giant MagnetoImpedance effect has been developed. The sensor performance is studied and estimated. The sensor circuitry consists of a square wave generator (driving source), a sensing element in a form of composite wire of a 25 $\mu$m copper core electrodeposited with a thin layer of soft magnetic material ($Ni_{80}Fe_{20}$), and two amplifier stages for improving the gain, switching mechanism, scaler circuit, an AC power source driving the permeability of the magnetic coating layer of the sensing element into a dynamic state, and a signal pickup LC circuit formed by a pickup coil and an capacitor. Experimental studies on sensor have been carried out to investigate the key parameters in relation to the sensor sensitivity and resolution. The results showed that for high sensitivity and resolution, the frequency and magnitude of the ac driving current through the sensing element each has an optimum value, the resonance frequency of the signal pickup LC circuit should be equal to or twice as the driving frequency on the sensing element, and the anisotropy of the magnetic coating layer of the sensing wire element should be longitudinal.

심자도 측정을 위한 SQUID 센서 기술의 개발 현황 (Review of SQUID Sensors for Measuring Magnetocardiography)

  • 이용호;김진목;유권규;김기웅;권혁찬
    • Progress in Superconductivity
    • /
    • 제13권1호
    • /
    • pp.1-6
    • /
    • 2011
  • Measurement of magnetic signals generated from electric activity of myocardium provides useful information for the functional diagnosis of heart diseases. Key technical component of the magnetocardiography (MCG) technology is SQUID. To measure MCG signals with high signal-to-noise ratio, sensitive SQUID magnetic field sensors are needed. Present magnetic field sensors based on Nb SQUIDs have field sensitivity good enough to measure most of MCG signals. However, for accurate measurement of fine signal pattern or detection of local atrial fibrillation signals, we may need higher field sensitivity. In addition to field sensitivity, economic aspect of the SQUID system is also important. To simplify the SQUID readout electronics, the output voltage or flux-to-voltage transfer of SQUID should be large enough so that direct measurement of SQUID output can be done using room-temperature preamplifiers. Double relaxation oscillation SQUID (DROS), having about 10 times larger flux-to-voltage transfers than those of DC-SQUIDs, was shown to be a good choice to make the electronics compact. For effective cancellation of external noise inside a thin economic shielded room, first-order axial gradiometer with high balance, simple structure and long-baseline is needed. We developed a technology to make the axial gradiometer compact using direct bonding of superconductive wires between pickup coil and input coil. Conventional insert has mechanical support to hold the gradiometer array, and the dewar neck has equal diameter with the dewar bottom. Boiling of the liquid He can generate mechanical vibrations in the gradiometer array due to mechanical connection structure. Elimination of the mechanical support, and direct mounting of the gradiometer array into the dewar bottom can reduce the dewar neck diameter, resulting in the reduction of liquid He consumption.

고감도 3축구동 액츄에이터를 위한 Rolling Mode 저감 연구 (A Study on Reducing Rolling Mode Effect in High-Sensitivity Optical Pickup 3-axis Actuator)

  • 김영중;홍삼열;김진아;최인호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.775-779
    • /
    • 2003
  • Recently, a new type actuator using multi-pole magnet has been developed for high-density and high-speed disk drive, which can be achieved higher sensitivity than a conventional actuator for applying one-pole magnet. However, it is very difficult for the actuator of multi-pole magnet to meet simultaneously the optimal design condition for reducing rolling mode effect and improving driving sensitivity because the force center is different from the mass center In this paper, First We propose the new shape coil for tracking which can reverse moment additionally in tracking motion, Next we achieve the optimal design to reduce phase disturbance and peak gain at the rolling mode frequency. Finally, the validity of the proposed methods is proved from experimental results.

  • PDF