• Title/Summary/Keyword: Physiological measurement

검색결과 490건 처리시간 0.029초

단련한 흰쥐의 속근 및 지근에 Glycogen 과저장이 운동 지구력에 미치는 영향 (Effects of Glycogen Supercompensation in Fast and Slow Muscles on Maximal Running Time of Endurance-trained Rats)

  • 연동수;황수관;김인숙;고성경;남택상;강두희
    • The Korean Journal of Physiology
    • /
    • 제22권1호
    • /
    • pp.63-77
    • /
    • 1988
  • This study was carried out to investigate relationships between maximal running time (MRT) and glycogen supercompensation in fast twitch white fibers (white vastus, WV), fast twitch red fibers (red vastus, RV) and slow twitch red fibers (soleus muscle, SM) of endurance-trained rats. Male rats of a Sprague-Dawley strain were divided into the trained groups and untrained groups. Untrained groups were acquired to run on the treadmill 10 minutes for 3 days and remained rest and maintained with mixed diet for 4 weeks. For last 10 days of resting period, the untrained rats were divided into 3 groups i.e. mixed diet (untrained control), high and low carbohydrate (CHO) diet groups. And each group was subdivided into 2 groups, one group was tested for the MRT and the other was sacrificed to measure the blood glucose, blood lactate, glycogen contents of liver and muscles. The experimental groups were trained on treadmill by a modified method of Constable et al. (1984) maintained with mixed diet for 4 weeks. After measurement of MRT of this group, they were also divided into high and low CHO groups and fed with these diet for 2 days and MRT of each group was measured again to see the effect of high or low CHO feeding on the MRT. Each group was maintained with the same diet for next 2 days during which some of the rats were sacrificed at given time intervals for the measurements of blood glucose and lactate, liver and the muscles glycogen. The results were summarized as follows; 1) In the untrained group, there were no significant differences between subgroups in MRT, glycogen conent of SM, RV and WV. But blood glucose concentration and glycogen content of liver of low CHO group were significantly lower than those of mixed diet group. 2) The MRT and glycogen content of SM, RV and WV of trained mixed diet group were significantly increased compared to those of untrained mixed diet group, but there was no significant difference in glycogen content of liver. 3) MRT of trained mixed, high CHO and low CHO groups were $137{\pm}9.8,\;176{\pm}9.8\;and\;129{\pm}7.3\;min$ respectively with the significant difference between them. 4) There were no differences in blood lactate concentrations between the trained high and low CHO groups immediately after maximal running and during recovery period. 5) Glycogen contents in RV and SM of trained high CHO group were significantly increased, and glycogen contents in RV, WV and liver of trained low CHO group were significantly decreased compared to those of trained mixed diet group. 6) Immediately after maximal running, the blood glucose concentrations of trained high CHO and low CHO groups were $73{\pm}4.0\;and\;67{\pm}6.9mg%$ respecitively. The blood glucose of the trained high CHO group was fully recovered within one hour by feeding. But blood glucose concentration of low CHO group was slowly recovered up to $114{\pm}4.1mg%$ after two hours of feeding and maintained. Those values were still significantly lower than that of trained mixed diet group. The synthetic rates of glycogen in liver and muscles during the recovery period followed the similar time course of the blood glucose recoveries in each group. These results suggest that an increase in MRT of trained high CHO group was attributed to the glycogen supercompensation in slow twitch muscle fibers. And a decrease in MRT of trained low CHO may be due to decreased glycogen contents of liver and muscles. The results also suggest that glycogen supercompensation was more evident in slow twitch red fibers of endurance-trained rats and blood glucose is one of the limiting factors of glycogen synthesis.

  • PDF

Reduced Glutathione의 In Vitro 첨가(添加)가 마우스간조직(肝組織)의 내재(內在) NP-SH 및 NP-SS에 미치는 영향(影響) (Effect of Reduced Glutathione on Non-Protein Sulfhydryl and Non-Protein Disulfide of the Mouse Liver in Vitro)

  • 오상유
    • The Korean Journal of Physiology
    • /
    • 제7권2호
    • /
    • pp.9-16
    • /
    • 1973
  • 마우스 간조직(肝組織)을 수종(數種) 농도(濃度)의 GSH 용액중(溶液中)에서 각각(各各) 4 C, 25 C 및 37 C의 온도(溫度)속에서 incubate하고, 5분(分), 30분(分) 및 60분(分)에서 각각(各各) NP-SH 및 NP-SS의 양(量)을 정량(定量)하여 정상(正常) 및 대조군(對照群)의 그것들과 비교(比較)한 결과(結果) 다음의 결과(結果)를 얻었다. 1) 4 C에서 incubate한 군(群)에서는 대조군(對照群) 및 GSH 10 gm/100 ml KRP의 농도(濃度)에서 대체(大體)로 정상치(正常値)에 비(比)하여 대차(大差)없는 NP-SH 및 NP-SS를 나타내고 GSH의 농도(濃度)가 높아져도 SH 기(基)의 증가(增加)는 현저(顯著)치 않았다. 2) 25 C에서 incubate한 군(群)에서의 NP-SH및 NP-SS는 GSH 20 mg/100 mg KRP 및 GSH 30 mg/100 mg KRP 의 양군(兩群)에서 GSH의 농도(濃度)와 시간경과(時間經過)에 비례(比例)해서 증가(增加)하였고, GSH 10 mg/100 ml KRP 군(群)에서는 incubation 30분(分)에서 최고치(最高値)를 나타내고 60분(分)에서는 오히려 약간(若干) 저하(低下)되는 경향(傾向)을 나타내었다. 3) 37 C에서 incubate 한 군(群)에서는 GSH 농도(濃度)와 incubation의 시간(時間)에 비례(比例)해서 NP-SH 및 NP-SS가 대체(大體)로 증가(增加)하고 증가(增加)의 율(率)도 가장 현저(顯著)하였다.

  • PDF

가토(家兎) 외경동맥(外經動脈)의 신장도(伸張度)에 대(對)하여 (On the Distensibility of the External Carotid Artery of the Rabbit)

  • 이동일;주영은
    • The Korean Journal of Physiology
    • /
    • 제7권2호
    • /
    • pp.49-58
    • /
    • 1973
  • 가토(家兎)의 외경동맥(外頸動脈)의 신장도(伸張度)를 알기 위(爲)하여 좌측(左側) 외경동맥(外經動脈)을 절단(切斷)하여 적출(摘出)하고 전혈질(全血質)과 횡절편(橫切片) 및 종절편(縱切片)을 작성(作成)한 후(後) 생리적식염수(生理的食鹽水) 중(中)에 둔 군(群)과 동일(同一)한 방법(方法)으로서 얻은 각(各) 혈질표본(血質標本)을 0.15 mM 및 0.30 mM의 ATP 용액중(溶液中)에 둔 군(群)에서 각각(各各) 15분(分), 45분(分) 및 75분(分)에서 길이 일장력곡선중(一張力曲線中) 탄성(彈性)의 한계(限界) 내(內)에서 Hooke의 법칙(法則)에 따르는 부위(部位)에서 Young 율(率)을 구(求)하여 서로 비교(比較)하였던 바 다음의 결과(結果)를 얻었다. 1) 가토(家兎) 외경동맥(外經動脈)의 전혈질(全血質)을 생리적식염수(生理的食鹽水)에 둔 군(群)에서는 그 Young 율(率)이 실험시간(實驗時間) 15분(分)에서는 $4.74{\times}10^7 dyne/cm^2$이었으나 45분(分) 및 75분(分)에서는 각각(各各) 4.62 및 $4.13{\times}10^7 dyne/cm^2$이었다. 한편 ATP 0.30mM의 농도(濃度)에서는 0.15mM의 농도(濃度)에 비(比)하여 낮은 Young 율(率)을 나타내었다. 2) 외경동맥(外經動脈)의 횡절편(橫切片)의 Young 율(率)은 생리적식염수중(生理的食鹽水中)에서는 15분(分), 45분(分) 및 75분(分)에서 각각(各各) 4.11, 3.75 및 $3.90{\times}10^7 dyne/cm^2$으로서 15분(分)이 가장 높고 그 후(後)는 큰 변화(變化)가 없는 경향(傾向)이었으나, ATP 첨가(添加)로서는 실험시간(實驗時間)에 따른 변화(變化)는 볼 수 없었다. ATP 첨가(添加)로서는 0.30mM의 농도(濃度)에서 0.15 mM의 농도(濃度)에 비(比)하여 Young 율(率)이 낮았다. 3) 외경동맥(外經動脈)의 종절편(縱切片)의 Young 율(率)은 생리적식염수(生理的食鹽水)에 둔 군(群)에서는 15분(分), 45분(分) 및 75분(分)에서 각각(各各) 2.12, 2.48 및 $2.46{\times}10^7 dyne/cm^2$으로서 실험초기(實驗初期)에 비(比)하여 후기(後期)에서 Young 율(率)이 약간(若干) 높은 경향(傾向)을 나타내었고, 이러한 경향(傾向)은 ATP의 첨가(添加)로서도 비슷하였다.

  • PDF

건조스트레스에 따른 옥상녹화 식물의 생리적 반응 (Physiological Responses of Green Roof Plants to Drought Stress)

  • 박성식;최재혁;박봉주
    • 한국조경학회지
    • /
    • 제45권2호
    • /
    • pp.51-59
    • /
    • 2017
  • 본 연구는 저관리 경량형 옥상녹화를 위해 맥문동, 울릉국화, 비비추, 돌나물, 잔디의 내건성을 평가하였다. 옥상녹화 식물의 내건성 평가를 위해 용적수분함량, 엽과 토양의 수분포텐셜, 엽록소 a와 b함량, 엽록소형광, 광합성율, 기공전도도, 증산속도, 항산화물질을 측정하였다. 옥상녹화 식물의 내건성 측정결과, 무관수 일수가 경과하면서 용적수분함량 부족에 따라 식물은 점차 고사하는 경향을 보였다. 울릉국화가 가장 먼저 고사하였으며, 그 다음으로 잔디, 비비추, 맥문동 순이었으며, 돌나물은 고사하지 않았다. 비비추, 맥문동, 돌나물은 3주 이상 생존하여 내건성이 높은 식물로 판단되었다. 엽록소 a와 b는 두 가지 유형이 나타났는데, 초기부터 중기까지 일정한 함량을 유지 후, 급격히 감소하는 I유형에는 비비추, 잔디와 초기에는 낮은 함량을 보이다가 중기 때 급격히 증가 후, 감소하는 II유형에는 울릉국화, 맥문동, 돌나물로 구분되었다. 용적수분함량과 증발산량은 모든 식물 종에서 지속적으로 감소하였으며, 엽록소형광 측정결과, 내건성이 상대적으로 높은 돌나물이 가장 늦게 감소하였고, 잔디와 돌나물은 급격한 감소가 나타난 후 고사하였다. 광합성, 기공전도도, 증산속도는 초기에 높은 활성도가 나타났으나, 용적수분함량의 감소로 인하여 식물체가 기공을 닫아 낮아지는 경향을 보였다. 항산화물질 측정결과, 건조스트레스가 증가하면 항산화물질의 양 또한 증가하나, 높은 스트레스가 유지되면 이러한 화합물이 지속적으로 소비되므로, 항산화물질의 증감은 내건성 평가 지표로 사용할 수 있을 것으로 판단된다.

작물육종 효율 극대화를 위한 피노믹스(phenomics) 연구동향: 화상기술을 이용한 식물 표현형 분석을 중심으로 (Current Statues of Phenomics and its Application for Crop Improvement: Imaging Systems for High-throughput Screening)

  • 이성곤;권택윤;서은정;배신철
    • 한국육종학회지
    • /
    • 제43권4호
    • /
    • pp.233-240
    • /
    • 2011
  • 식물 피노믹스 분야에서 초고속 대량선발이 가능하도록 만든 화상기술(imaging technology)을 온실자동화 기술, 이미지 촬영 및 분석기술 등으로 분류하여 개념을 정리하고, 화상기술을 개발 및 응용하고 있는 주요 연구기관의 현황을 소개하였다. 연구동향 파악을 위해 작물의 내재해성 검정, 병해충진단, 종자활력 검정, 수확후 관리, 생체리듬 연구 등 다양한 분야에서 응용되고 있는 사례들을 살펴보았다. 향후 열 화상, 형광 화상 기술을 UV-induced blue green fluorescence, hyperspectral imaging 등과 상호 보완해서 multi-sensor 개념으로 발전시켜 나간다면, 식물의 생산량 증대를 위한 스트레스 내성자원 선발의 효율성을 극대화할 수 있을 뿐만 아니라 다양한 파장대의 영상정보로부터 각 스트레스의 특징을 catalogue화하는 것이 가능하여 다양한 스트레스를 정확히 진단하고 정량화할 수 있을 것으로 보이며, 나아가 각종 스트레스에 대한 조기 경보시스템으로도 활용할 수 있을 것이다. 호주 Plant Phenomics Centre에서는 온실과 포장을 포함한 Phenomics 기술의 종합적 개념도를 그림 4와 같이 제시하고 각 부문별 필요기술을 개발 중에 있는데, 종합기술로 완성된다면 현재의 작물 품종개량 속도를 획기적으로 향상시킬 수 있을 것으로 기대된다. 호주는 그 동안 분자생물학, 식물생리학 분야에서는 기술력을 확보해 왔지만 BT, IT 등 융복합농업기술분야에서는 다른 나라에 비해 역량을 결집하지 못하고 뒤쳐져 있었다고 볼 수 있는데, 연구개발의 궁극적인 목표인 실용화 단계에서의 기술우위를 선점함으로써 그간의 약세를 만회하고자 Phenomics 연구시설을 설치하였다고 한다. 이점은 BT 후발주자이면서 국제적 경쟁력을 확보하려는 우리에게 시사하는 바가 크다. Phenomics 연구는 생명공학기술을 통해 창출된 GM 식물체, 전통육종을 통해 육성된 육종재료 등 모든 유용 유전자원을 평가, 검정할 수 있는 신품종 육성의 기본 기술로 부상하고 있다. 지난 수년간 정체되어 있는 국내 종자시장을 고부가 수출산업으로 육성하기 위해서는 유용 유전자원, 농업생명공학산물의 실용화를 가속화하여야 하며, 이를 위해 피노믹스 기술 확보 및 시설 인프라 구축을 전략적으로 신중히 검토해봐야 할 시점이다.

운동훈련(運動訓練)에 대(對)한 심폐기능(心肺機能)의 적응(適應)에 관(關)한 연구(硏究) (Cardio-pulmonary Adaptation to Physical Training)

  • 조강하
    • The Korean Journal of Physiology
    • /
    • 제1권1호
    • /
    • pp.103-120
    • /
    • 1967
  • As pointed out by many previous investigators, the cardio-pulmonary system of well trained athletes is so adapted that they can perform a given physical exercise more efficiently as compared to non-trained persons. However, the time course of the development of these cardio-pulmonary adaptations has not been extensively studied in the past. Although the development of these training effects is undoubtedly related to the magnitude of an exercise load which is repeatedly given, it would be practical if one could maintain a good physical fitness with a minimal daily exercise. Hence, the present investigation was undertaken to study the time course of the development of cardio-pulmonary adaptations while a group of non-athletes was subjected to a daily 6 to 10 minutes running exercise for a period of 4 weeks. Six healthy male medical students (22 to 24 years old) were randomly selected as experimental subjects, and were equally divided into two groups (A and B). Both groups were subjected to the same daily running exercise (approximately 1,000 kg-m). 6 days a week for 4 weeks, but the rate of exercise was such that the group A ran on treadmill with 8.6% grade for 10 min daily at a speed of 127 m/min while the group B ran for 6 min at a speed of 200 m/min. In order to assess the effects of these physical trainings on the cardio-pulmonary system, the minute volume, the $O_2$ consumption, the $CO_2$ output and the heart rate were determined weekly while the subject was engaged in a given running exercise on treadmill (8.6% grade and 127 m/min) for a period of 5 min. In addition, the arterial blood pressure, the cardiac output, the acid-base state of arterial blood and the gas composition of arterial blood were also determined every other week in 4 subjects (2 from each group) while they were engaged in exercise on a bicycle ergometer at a rate of approximately 900 kg m/min until exhaustion. The maximal work capacity was also determined by asking the subject to engage in exercise on treadmill and ergometer until exhaustion. For the measurement of minute volume, the expired gas was collected in a Douglas bag. The $O_2$ consumption and the $CO_2$ output were subsequently computed by analysing the expired gas with a Scholander micro gas analyzer. The heart rate was calculated from the R-R interval of ECG tracings recorded by an Offner RS Dynograph. A 19 gauge Cournand needle was inserted into a brachial artery, through which arterial blood samples were taken. A Statham $P_{23}AA$ pressure transducer and a PR-7 Research Recorder were used for recording instantaneous arterial pressure. The cardiac output was measured by indicator (Cardiogreen) dilution method. The results may be summarized as follows: (1) The maximal running time on treadmill increased linearly during the 4 week training period at the end of which it increased by 2.8 to 4.6 times. In general, an increase in the maximal running time was greater when the speed was fixed at a level at which the subject was trained. The mammal exercise time on bicycle ergometer also increased linearly during the training period. (2) In carrying out a given running exercise on treadmill (8.6%grade, 127 m/min), the following changes in cardio·pulmonary functions were observed during the training period: (a) The minute volume as well as the $O_2$ consumption during steady state exercise tended to decrease progressively and showed significant reductions after 3 weeks of training. (b) The $CO_2$ production during steady state exercise showed a significant reduction within 1 week of training. (c) The heart rate during steady state exercise tended to decrease progressively and showed a significant reduction after 2 weeks of training. The reduction of heart rate following a given exercise tended to become faster by training and showed a significant change after 3 weeks. Although the resting heart rate also tended to decrease by training, no significant change was observed. (3) In rallying out a given exercise (900 kg-m/min) on a bicycle ergometer, the following change in cardio-vascular functions were observed during the training period: (3) The systolic blood pressure during steady state exercise was not affected while the diastolic blood Pressure was significantly lowered after 4 weeks of training. The resting diastolic pressure was also significantly lowered by the end of 4 weeks. (b) The cardiac output and the stroke volume during steady state exercise increased maximally within 2 weeks of training. However, the resting cardiac output was not altered while the resting stroke volume tended to increase somewhat by training. (c) The total peripheral resistance during steady state exercise was greatly lowered within 2 weeks of training. The mean circulation time during exorcise was also considerably shortened while the left heart work output during exercise increased significantly within 2 weeks. However, these functions_at rest were not altered by training. (d) Although both pH, $P_{co2}\;and\;(HCO_3-)$ of arterial plasma decreased during exercise, the magnitude of reductions became less by training. On the other hand, the $O_2$ content of arterial blood decreased during exercise before training while it tended to increase slightly after training. There was no significant alteration in these values at rest. These results indicate that cardio-pulmonary adaptations to physical training can be acquired by subjecting non-athletes to brief daily exercise routine for certain period of time. Although the time of appearance of various adaptive phenomena is not identical, it may be stated that one has to engage in daily exercise routine for at least 2 weeks for the development of significant adaptive changes.

  • PDF

방사성의약품 투여 시 피폭선량 저감에 대한 연구 (The Study of Radiation Reducing Method during Injection Radiopharmaceuticals)

  • 조석원;정석;박준영;오신현;남궁혁;오기백;김재삼;이창호
    • 핵의학기술
    • /
    • 제16권1호
    • /
    • pp.80-85
    • /
    • 2012
  • 전신 골 스캔은 골친화성 방사성의약품으로 뼈의 생리적 변화를 영상화하는 검사방법으로, 140 keV의 감마선을 방출하는 방사성핵종이 표지된 방사성의약품을 주사 후 촬영하는 영상기법이다. 외부피폭으로부터 방사선방호의 3원칙은 시간, 거리, 차폐이다. 방사성의약품은 투여 시 개봉선원이 되기 때문에 방사선방호 원칙에 따라 피폭을 줄이기 위하여 빠른 시간 내에 주사하는 것이 좋다. 하지만 방사성의약품은 환자에게 직접 투여하기 때문에 선원으로부터 거리를 멀리할 수 없는 제한점이 있다. 본 연구는 방사성의약품으로부터 거리에 따른 피폭선량 변화를 확인하고, 차폐체를 사용 후 피폭량의 변화를 관찰하여 방사선 종사자의 피폭 관리에 도움이 되고자 한다. 방사성의약품 투여 시 소요되는 주사시간의 평균을 구하기 위하여 훈련된 주사 담당자가 환자에게 주사하는 시간을 총 50회 측정하였고, 그 평균값(약 2분)을 구하였다. 1 mL주사기에 옥시드로산테크네슘 925 MBq를 0.2 mL 로 맞춘 다음 50 cm, 100 cm, 150 cm, 200 cm에서 방사선 측정기(FH-40, Thermo Scientific, USA)로 선량을 측정하였다. 그리고 방사선차폐체(납 6 mm)를 선원으로부터 25 cm에 설치 한 후 50 cm 거리에서 선량을 측정하였다. 모든 선량측정은 각각 20회에 걸쳐 재현성을 검증하였다. 차폐 전과 차폐 후의 선량의 상관관계는 SPSS (ver. 18)을 사용하여 paired t-test로 검증하였다. 차폐체를 설치하지 않은 선원으로부터 거리에 따른 2분간 받는 피폭량은 50 cm에서 $1.986{\pm}0.052{\mu}Sv$, 100 cm에서 $0.515{\pm}0.022{\mu}Sv$, 150 cm에서 $0.251{\pm}0.012{\mu}Sv$, 200 cm에서 $0.148{\pm}0.006{\mu}Sv$로 나타났다. 차폐를 설치 후 측정 시 피폭량은 $0.035{\pm}0.003{\mu}Sv$로 차폐체 사용 전과 후의 피폭선량은 통계적으로 유의한 차이가 있는 것으로 나타났다($p$<0.001).전신 골스캔은 핵의학 검사에서 많은 비중을 차지하고 있기 때문에 방사성의약품 투여 시 피폭을 줄이기 위해서 외부피폭의 방어원칙을 적절히 병행하여 피폭 저감을 위해 노력해야 한다. 하지만 방사성의약품은 환자에게 직접 투여하기 때문에 선원으로부터 거리를 멀리할 수 없고, 환자의 혈관 확보가 어려운 경우 주사시간이 길어질 수 있다. 본 연구를 통해 거리가 멀어짐에 따라 피폭선량이 감소하는 것을 확인하였고, 선원으로부터25 cm 거리에 차폐체 설치 시 피폭선량이 감소하는 것을 확인할 수 있었다. 본 연구를 통해 방사성의약품 투여 시 차폐체를 사용함으로써 방사선 피폭 저감에 도움이 될 것으로 사료된다.

  • PDF

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

농가부업(農家副業)의 소득향상(所得向上)을 위한 양육생산(羊肉生産) 및 모피가공(毛皮加工)에 관(關)한 연구(硏究) (Studies on the Meat Production and Woolskin Processing of Sheep and Korean Native Goats for Increasing Farm Income as a Family Subsidiary Work)

  • 권순기;김종우;한성욱;이규승
    • 농업과학연구
    • /
    • 제5권2호
    • /
    • pp.93-114
    • /
    • 1978
  • 본(本) 시험(試驗)은 농가(農家)에서 부업(副業)으로 면양(緬羊)과 산양(山羊)을 사육(飼育)하여 농가수입(農家收入)을 향상(向上)시킬 수 있는 방안(方案)으로 모색(摸索)하고 아울러 면(緬) 산양(山羊)의 산육성(産育性), 산모성(産毛性), 모피이용성(毛皮利用性), 생리적(生理的) 특성(特性) 및 각(各) 경제형질간(經濟形質間)의 상호관계(相互關係)를 구명(究明)하기 위하여 1977년(年) 5월(月) 5일(日)부터 1977년(年) 11월(月) 26일(日)까지 충남대학교(忠南大學校) 농과대학(農科大學) 부속동물사육장(附屬動物飼育場)과 대전근교(大田近郊)의 농가(農家)를 선정(選定)하여 양(羊)의 발육성적(發育成績), 도체성적(屠體成績), 내장중량(內臟重量), 혈액(血液) 및 혈장성분(血漿成分), 채식성(採食性), 경제성(經濟性)을 분석(分析)하고 아울러 각(各) 경제형질간(經濟形質間)의 상관(相關)을 산출(算出)하여 비교검토(比較檢討)하였다. 본(本) 시험(試驗)에서 얻어진 결과(結果)를 요약(要約)하면 다음과 같다. 1. 산육성(産肉性) 및 육질(肉質) 1) 면양(緬羊)고 산양(山羊)의 발육성적(發育成績)은 196일간(日間)을 사육(飼育)한 결과(結果), 시험개시시(試驗開始時) 평균(平均) 체중(體重) 20kg와 8kg의 2배(倍)로 각각(各各) 증가(增加)되었다. 2) 면양(緬羊)은 사사구(舍飼區)와 방목구간(放牧區間)의 증체량(增體量)에 유의적(有意的) 차이(差異)가 없었다. 3) 산양(山羊)의 사육(飼育)은 전염성(傳染性) 질병(疾病)의 오염(汚染)이 없는 공주군(公州郡) 야산지대(野山地帶)에서 발육성적(發育成績)이 양호(良好)하였다. 4) 면양(緬羊)의 18개월령(個月齡) 체척측정치(體尺測定値)에서 체고(體高)에 대(對)한 비율(比率)은 십자부고(十字部高) 103%, 체장(體長) 104%, 흉심(胸心) 44%, 흉폭(胸幅) 31%, 요각폭(腰角幅) 23%, 흉위(胸圍) 135%, 전관위(前管圍) 15%였다. 재래산양(在來山羊)은 8개월령(個月齡)에서 십자부고(十字部高) 106%, 체장(體長) 109%, 흉심(胸深) 46%, 흉위(胸圍) 122%로서 면양(緬羊)보다 십자부고(十字部高), 체장(體長)과 흉심(胸心)의 비율(比率)이 높았으나 흉위(胸圍)의 비율(比率)은 낮았다. 5) 도체성적(屠體成績)에서 면양(緬羊)은 도체율(屠體率)은 $47.52{\pm}2.27%$, 골격비율(骨格比率) $9.75{\pm}1.49%$, 두골비율(頭骨比率) $2.68{\pm}0.42%$, 피모비율(皮毛比率) $20.95{\pm}2.14%$였으며, 재래산양(在來山羊)에서는 도체율(屠體率) $45.58{\pm}5.63%$, 정육율(精肉率) $27.62{\pm}3.81%$, 내장비율(內臟比率) $34.86{\pm}4.16%$, 골격(骨格), 두골(頭骨), 피모비율(皮毛比率)이 각각(各各) $11.66{\pm}1.86%$, $3.63{\pm}1.61%$, $9.26{\pm}2.41%$이었다. 6) 한국재래산양(韓國在來山羊)을 방목사사(放牧舍飼)할 경우 생산(生産)되는 도육(屠肉)의 수분(水分), 조단백(粗蛋白), 조지방(粗脂肪), 조회분(粗灰分) 함량(含量)은 근사(近似)한 차이(差異)를 나타내었다. 또한 방목(放牧) 및 사사(舍飼)한 면양도육(緬羊屠肉)을 분석(分析)한 결과(結果) 방목구(放牧區)는 사사구(舍飼區)에 비하여 수분(水分) 및 단백질함량(蛋白質含量)이 높고 지방함량(脂肪含量)은 감소(減少)하였다. 7) 각(各) 내장(內臟)의 중량(重量)은 면양(緬羊)과 재래산양(在來山羊)이 비교적(比較的) 유사(類似)한 변화(變化) 경향(傾向)을 보였는데 간장(肝臟), 심장(心臟), 신장(腎臟), 비장(脾臟)은 비교군간(比較群間)에 유의성(有意性)이 인정(認定)되지 않았으며, 제(第)1 제(第) 2위(胃) 및 대(大), 소장(小腸)은 방목구(放牧區)가 사사구(舍飼區)에 비(比)하여 유의(有意)하게 높은 값을 나타냈고 복강내(腹腔內)의 지방량(脂肪量)은 사사구(舍飼區)가 방목구(放牧區)보다 유의성(有意性)이 인정(認定)되는 높은 값을 나타냈다. 2. 산모성(産毛性) 및 모피(毛皮) 1) 7개월간(個月間) 사육(飼育)한 면양(緬羊)의 산모량(産毛量)은 $3.88{\pm}1.02kg$였으며 산모량(産毛量)은 $9.27{\pm}1.48%$, 모속량(毛束量)) $8.47{\pm}1.00cm$ 직선모장(直線毛長) $10.63{\pm}0.99cm$, 1일(日) 모성장(毛成長)은 $0.40{\pm}0.44cm$ Crimp수(數)는 $2.78{\pm}0.40$이였다. 2) 면양모피(緬羊毛皮)를 명(明)유제하여 부위별(部位別)로 항장력(抗長力) 및 인열강도(引裂强度)를 조사(調査)한 결과(結果) 둔부(臀部)가 항장력(抗張力) $1.35kg/mm^2$ 인열력(引裂力) $2.252kg/mm^2$로서 가장 강(强)하였으며 배부(背夫), 견부(肩部)의 순위(順位)로로 항장력(抗張力) 및 인열력(引裂力)을 나타내었다. 3. 초지(草地)의 이용(利用) 및 개량(改良) 1) 재래산양(在來山羊)의 방목(放牧) 및 계목시(繫牧時)의 채식량(採食量)은 오전(午前)에 비하여 오후(午後)가 많았으며 방목(放牧) 및 계목간(繫牧間)에는 큰 차이(差異)를 나타내지 않았다. 면양(緬羊)의 방목(放牧)과 계목시(繫牧時)의 채식량(採食量)은 방목(放牧)이 계목(繫牧)보다 우수하였으며 오전9午前)에 비(比)하여 오후(午後)가 다량(多量) 채식(採食)하였다. 2) 재래산양(在來山羊)과 면양(緬羊)을 이용(利用)하여 제경조성(蹄耕造成)한 목초지(牧草地)의 정착상태(定着狀態)를 조사(調査)한 결과 재래산양구(在來山羊區)는 6025% 면양구(緬羊區)는 77.35%로서 면양(緬羊)의 이용(利用)이 우수(優秀)하였고 재래산양(在來山羊)은 방목력(放牧力)의 부족(不足)으로 제경효과(蹄耕效果)가 적었다. 4. 각(各) 경제형질(經濟形質)의 상관(相關) 1) 면양(緬羊)의 산육성(産肉性)과 여러 형질(形質)사이의 상관(相關)은 생체중(生體重)과 일당증체량간(日當增體量間)에 높은 상관(相關)을 보여 주었고 기타(其他) 형질(形質)사이에서는 별로 상관(相關)이 없었으나 흉추(胸椎)길이와 생체중(生體重), 일단증체량(日當增體量), 정육율간(精肉率間)에서는 비교적(比較的) 높은 상관(相關)이 나타나고 있다. 재래산양(在來山羊)에 잇어서는 생체중(生體重)과 일당(日當) 증체량(增體量) 사이에 높은 상관(相關)이 있었으며 도체중(屠體重)과 정육량(精肉量) 사이에도 비교적(比較的) 높은 상관(相關)이 있었으나 내장중(內臟重)과 생체중(生體重), 일당(日當) 증체량(增體量) 사이에는 부(負)의 상관(相關)을 보여주고 있다. 2) 면양(緬羊)의 산모성(産毛性) 형질(形質) 상호간(相互間)의 상관(相關)에서는 산모량(産毛量)과 생체중(生體重), 일당(日當) 증체량(增體量), 산모율간(産毛率間)에 1% 수준(水準)에서 높은 상관(相關)을 나타내고 있어 성장(成長)이 빠른 개체에 산모량(産毛量)도 많다는 것을 추정할 수 있었다. 3) 산육성(産肉性) 형질(形質)과 체척측정치(體尺測定値) 사이의 상관(相關)은 면양(緬羊)에서는 생체중(生體重), 정육중(精肉重), 내장중(內臟重)과 흉위(胸圍), 체장(體長)사이에서 제일 높았고, 도체중(屠體重), 정육중(精肉重)과 비교적(比較的) 높은 부위(部位)는 흉폭(胸幅), 흉심(胸深)이었다. 따라서 면양(緬羊)의 체척측정(體尺測定)에 중점(重點)을 두는 것이 유효(有效)할 것으로 생각된다. 재래산양(在來山羊)의 산육성(産肉性) 형질(形質)과 체척측정치(體尺測定値) 사이에는 체척부위(體尺部位)의 대부분이 산육성형질(産肉性形質)과 높은 상관(相關)을 나타내고 있으며 특히 흉위(胸圍)와 생체중(生體重), 도체중(屠體重), 정육중(精肉重), 골격비율(骨格比率)사이에서는 0.922~0.974의 높은 상관(相關)을 보여주고 있다. 한편 산육성(産肉性) 형질(形質)과 흉심(胸深), 전관위(前管威), 체장(體長)사이에도 각각(各各) 0.759~0.911, 0.759~0.909, 0.708~0.872의 비교적(比較的) 높은 상관(相關)을 나타내고 있다. 따라서 재래산양(在來山羊)에 대한 산육성(産肉性) 추정(推定)은 흉부(胸部)에 대한 c체척치(體尺値)가 상당히 큰 의의(意義)가 있을 것으로 본다. 5. 혈액상(血液像) 및 혈장성분(血漿成分) 1) 적혈구수(赤血球數)와 평균(平均) 혈색소농도(血色素濃度)는 재래산양(在來山羊)이 각각(各各) $12.93{\times}10^6/mm^3$와 36.26%에 대하여 유의성(有意性)이 인정(認定)되는 높은 값을 나타냈다. 2) 혈색소량(血色素量), 적혈구용적(赤血球容積), 평균(平均) 적혈구용적(赤血球容積) 및 평균혈색소량(平均血色素量)은 재래산양(在來山羊)이 각각(各各) 10.92g/100ml, 3.02ml/100ml, $23.40{\mu}^3$ 및 10.94pg로서 면양(緬羊)의 11.73g/100ml, 36.25ml/ml, $33.97{\mu}^3$ 및 8.43pg에 비하여 낮은 값을 나타냈는데 모두 유의성(有意性)이 인정(認定)되었다. 3) 백혈구(白血球)의 수(數)는 재래산양(在來山羊)이 $11.64{\times}10^3/mm^3$을 나타내어 면양(緬羊) $9.32{\times}10^3/mm^3$보다 유의(有意)하게 높은 값을 나타냈다. 4) 백혈구(白血球)의 감별(鑑別) 수(數)에 있어서 호염구(好鹽球)는 재래산양(在來山羊)이 임파구(淋巴球)는 면양(緬羊)이 유의(有意)학 높은 값을 나타냈으며 호염구(好鹽區), 호산구(好酸球) 및 단핵구(單核球)는 차이(差異)가 없었다. 5) 혈장중(血漿中)에 함유(含有)되어 있는 총단백질(總蛋白質)과 포도당(葡萄糖)의 양(量)은 재래산양(在來山羊)이 각각(各各) 62g/100ml와 53.6mg/100ml로서 면양(緬羊)의 5.6g/100ml와 45.7mg/100ml보다 유의(有意)하게 높은 값을 나타냈으며, 총지질(總脂質)의 양(量)은 재래산양(在來山羊)이 127.6mg/100ml로서 면양(緬羊)의 149.6mg/100ml보다 유의성(有意性)이 인정(認定)되는 낮은 값을 나타냈다. 6) 비단백질태질소화합물(非蛋白質態窒素化合物), Cholesterol, Ca, P, K, Na 및 Cl의 함량(含量)은 면양(緬羊)과 산양간(山羊間)에 차이(差異)가 없었다. 6. 경제성분석(經濟性分析) 1) 면양(緬羊)과 산양(山羊)을 196일간(日間) 사육(飼育)하였을 때 농가수익(農家收益)은 1두당(頭當) 4,000원 정도(程度)였으며 농가(農家)에서 부업(副業)으로 사육(飼育)할 수 있는 적정규모(適正規模)는 5~10두(頭)이다.

  • PDF