• Title/Summary/Keyword: Physiologic parameter

Search Result 12, Processing Time 0.03 seconds

THE COMPARATIVE STUDY ON THE SEDATIVE EFFECT OF ORAL MIDAZOLAM AND INTRAMUSCULAR MIDAZOLAM IN SEDATING YOUNG PEDIATRIC DENIAL PATIENTS (소아 환자에서 미다졸람의 경구 투여와 근육 투여에 의한 진정 효과의 비교 연구)

  • Min, Yu-Jin;Yu, Seung-Hoon;Kim, Jong-Soo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.1
    • /
    • pp.53-61
    • /
    • 2006
  • When routine behavior control is impossible, midazolam is often used for sedation, because it has wide margin of safety, relatively few side-effects and multiple route of administration. Although intramuscular administration of all administration route is frequently used, it is a major source of anxiety, discomfort, and trauma in children. To the contrary, oral administration of midazolam is easily administered and accepted by children. But, it's therapeutic drug concentration has not been established. The purpose of this study was to compare sedation effect and physiologic parameter of oral midazolam which palliate demerits of intramuscular administration in sedating young pediatric patients with intramuscular midazolam Twelve negative children, mean age 62.5 months, who needed at least two separate restorative visits, requiring local anesthesia participated in this study On every visit, one of the following 2 different sedative regimen was given : (1) 0.30mg/kg midazolam by intramuscular administration (2) 0.75mg/kg by oral administration. Physiologic parameter(oxygen saturation, heart rate) was recorded by ten procedure and behavior was videotaped and rated using Ohio State University Behavior Rating Scale and Automated Counting System by one investigator, blind to administration route The analyzed sedative effect of oral midazolam resulted in good sedative effect, comparing to intramuscular route, And there is no statistically difference between oral and intramuscular administration of midazolam (p>0.05).

  • PDF

THE COMPARATIVE STUDY ON THE EFFICACY OF CHLORAL HYDRATE AND HYDROXYZINE OF DIFFERENT DOSES IN SEDATING YOUNG PEDIATRIC DENTAL PATIENTS (Chloral hydrate와 병용투여 시 Hydroxyzine용량에 따른 진정효과의 비교연구)

  • Lee, In-Cheon;Kim, Jong-Soo;Kwoon, Soon-Won
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.3
    • /
    • pp.430-440
    • /
    • 2001
  • Orally administered chloral hydrate is often used, because of it's wide margin of safety and relatively few sideeffects. Hydroxyzine is an antihistamine with sedative and anti-emetic properties. It has been used in conjunction with chloral hydrate to reduce the incidence of nausea and vomiting. But, it's therapeutic drug concentration has not been established. The purpose of this study was to assess the sedative effect and physiologic parameter of hydroxyzine of different doses in sedating young pediatric dental patients. Fifty uncooperative children, mean age 33.2 months, who needed at least four separate restorative visits, requiring local anesthesia participated in this study. On every visit, one of the following 4 different sedative regimen was given (1) 70mg/kg CH (2) 70mg/kg CH and 1mg/kg HD (3) 70mg/kg CH and 2mg/kg HD (4) 70mg/kg CH and 3mg/kg HD. Physiologic parameter was recorded and behavior was videotaped and rated using Ohio State University Behavior Rating Scale by one investigator, blind to the dose. The analyzed sedative effect of combined oral administration of 70mg/kg chloral hydrate and 2mg/kg hydroxyzine was superior to the other regimens. Evidence of adverse effect was not detected or reported during and/or after the procedures.

  • PDF

A critical review on blood flow in large arteries; relevance to blood rheology, viscosity models, and physiologic conditions

  • Yilmaz, Fuat;Gundogdu, Mehmet Yasar
    • Korea-Australia Rheology Journal
    • /
    • v.20 no.4
    • /
    • pp.197-211
    • /
    • 2008
  • The purpose of this study is mainly directed towards present of viewpoints on critical and commentary analysis on blood rheology, blood viscosity models, and physiological flow conditions. Understanding these basics is fundamental to meet the need for a sufficient and reliable CFD model of blood. Most of the used viscosity models on this manner have determined from parameter fitting on experimental viscosity data. Availability of experimental data from literature to define viscosity models of CFD analysis should be accurately chosen and treated in order to avoid any errors. Several basic gaps that limit the CFD model results are identified and given opportunities for future research.

Effect of Metal Components in Seminal Plasma on Seminal Parameter and Male Fertile Ability (정장액내의 금속성분이 정액지표 및 가임능에 미치는 영향)

  • Park, Nam-Cheol;Kim, Min-Soo;Yoon, Jong-Byung
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.24 no.1
    • /
    • pp.67-81
    • /
    • 1997
  • To determine the concentration and the physiologic role of metal components in blood plasma and seminal plasma in relation to male infertility, the concentrations of twelve metal components in blood plasma and seminal plasma including Na, Mg, K, Ca, Cr, Mn, Fe, Cu, Zn, Se, Cd and Pb were measured by atomic absorbance spectrophotometery or ion selective electrode analysis. Semen and blood samples were obtained from a total of 110 men including 70 male infertility patients, 20 vasectomized persons and 20 fertility proven volunteers visited to the Male Infertility Clinic of Pusan National University Hospital. The concentrations of Ca, Zn, Mg, Cr and Cd in control group were higher in seminal plasma than in blood plasma, and additionally Pb were higher in infertility group. The concentrations of all metal components revealed no significant difference according to patients' age, resident, occupation, sperm density, motility and hormone level in blood plasma, but some metal components including Ca, Mg, Cu, Mn, Cd and Pb revealed a significant difference according to each these parameters except patient's age in seminal plasma. The concentrations of Mn, Cd and Pb in the vasectomy persons were higher than in the infertility group III including testicular and epididymal factors, but not in blood plasma. We conclude that the quantitative changes of metal components in the seminal plasma may have effects on not only spermatogenesis and sperm function, but also contribute to diagnostic parameter according to organ specificity of the metal in the male reproduction.

  • PDF

Development of the Control System for the Motor-Driven Electromechanical Total Artificial Hearta

  • Kim, Hee-Chan;Lee, Sang-Hun;Kim, Jong-Won-;Kim, Jin-Tae-;Min, Byoung-Goo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1988.10b
    • /
    • pp.858-863
    • /
    • 1988
  • A micro-processor based control system for a brushless DC motor used in the motor-driven electromechanical total artificial heart was developed. Functionally, the control system is composed of two parts. The first part is the velocity and position controller to assure that the motor follows a predetermined optimal velocity profile with minimal energy consumption, and to guarantee the full stroke length. This part also utilize the passive adaptive control method to be robust against the load disturbance, system parameter variation, and uncertainty which is the environment of artificial heart system. The pump output control is the second part, and this part provides the required responses of the artificial heart to the time-varying physiologic demands. The basic requirements of these responses are preload sensitivity, afterload insensitivity, and the balanced ventricular outputs. The performance and reliability of this control system was evaluated through a series of mock circulation tests and animal implantation, and the results are very encouraging.

  • PDF

A Study on Locational Control of Motion Ghost in Magnetic Imaging System (자기공명영상장치(磁氣共鳴映像裝置)에서 움직임허상(虛像)의 위치제어(位置制御)에 관(關)한 연구(硏究))

  • Lee, Who-Min
    • Journal of radiological science and technology
    • /
    • v.16 no.2
    • /
    • pp.19-26
    • /
    • 1993
  • Magnetic Resonance Image represents three-dimensional diagnostic imaging technique using both nuclear magnetic resonance phenomenon and computer. Compared with computed tomography (CT), MRI have advantages harmless to patient's body, three-dimensional image with high resolution and disadvantages long data acquisition time because of long T1 relaxation time, relatively low signal to noise ratio, high cost of setting, also. As physiologic motion of tissue results in motion ghost in MRI, high 2.0Tesla make improve low signal to noise ratio. This study have aim to improve image quality with controling motion ghost of tissue. Supposing a moving pixel in constant frequency, one pixel make two ghosts which are same size and different anti-phase. So, this study will show adjust parameter on locational control of motion ghost. Author made moving phantom replaced by respiratory movement of human, researched change of motion frequency, FOV by location shift, and them decided optimal FOV (field of view). The results are as follows: 1. The frequency content of the motion determines how far the image always appear in phase-encoding direction, the morphology of the ghost image is characteristic of the direction of the motion and its amplitude. 2. Double FOV of fixed signal object for locational control of motion ghost is recommended. Decreasement of spatial resolution by increasing FOV can compensate on increasing of matrix in spite of scan time increasement.

  • PDF

A Comparative Study of Item Difficulty Hierarchy of Self-Reported Activity Measure Versus Metabolic Equivalent of Tasks

  • Choi, Bong-Sam
    • Physical Therapy Korea
    • /
    • v.20 no.3
    • /
    • pp.89-99
    • /
    • 2013
  • The purposes of this study were: 1) to show the item difficulty hierarchy of walking/moving construct of the International Classification of Functioning, Disability and Health-Activity Measure (ICF-AM), 2) to evaluate the item-level psychometrics for model fit, 3) to describe the relevant physical activity defined by level of activity intensity expressed as Metabolic Equivalent of Tasks (MET), and 4) to explore what extent the empirical activity hierarchy of the ICF-AM is linked to the conceptual model based on the level of energy expenditure described as MET. One hundred and eight participants with lower extremity impairments were examined for the present study. A newly created activity measure, the ICF-AM using an item response theory (IRT) model and computer adaptive testing (CAT) method, has a construct on walking/moving construct. Based on the ICF category of walking and moving, the instrument comprised items corresponding to: walking short distances, walking long distances, walking on different surfaces, walking around objects, climbing, and running. The item difficulty hierarchy was created using Winstep software for 20 items. The Rasch analyses (1-parameter IRT model) were performed on participants with lower extremity injuries who completed the paper and pencil version of walking/moving construct of the ICF-AM. The classification of physical activity can also be performed by the use of METs that is often preferred to determine the level of physical activity. The empirical item hierarchy of walking, climbing, running activities of the ICF-AM instrument was similar to the conceptual activity hierarchy based on the METs. The empirically derived item difficulty hierarchy of the ICF-AM may be useful in developing MET-based activity measure questionnaires. In addition to convenience of applying items to questionnaires, implications of the finding could lead to the use of CAT method without sacrificing the objectivity of physiologic measures.

Physiologic Cervical Alignment Change between Cervical Spine X-ray and Computed Tomography

  • Lee, Ho Jin;Kim, Il Sup;Hong, Jae Taek
    • Journal of Korean Neurosurgical Society
    • /
    • v.64 no.5
    • /
    • pp.784-790
    • /
    • 2021
  • Objective : The purpose of this study was to investigate the correlations among various radiological parameters used to determine cervical alignment from cervical spine radiographs (X-CS) and cervical spine computed tomography (CT-CS), both within and between modalities. Methods : This study included 168 patients (≤60 years old) without a definite whole spine deformity who underwent CT-CS and X-CS. We measured occipital slope (O-s), C1 slope, C2 slope, C7 slope, sella turcica - C7 sagittal vertical axis (StC7-SVA), spino-cranial angle, T1 slope, and C27-SVA. We calculated the O-C2 angle, O-C7 angle, and C2-7 angle from the measured parameters and conducted correlation analyses among multiple parameters. Results : The intrinsic correlation features among multiple cervical parameters were very similar for both X-CS and CT-CS. The two SVA parameters (C27-SVA and StC7-SVA) were mainly influenced by the upper cervical slope parameters (r=|0.13-0.74|) rather than the lower slope cervical parameters (r=|0.08-0.13|). The correlation between X-CS and CT-CS for each radiological parameter was statistically significant (r=0.26-0.44) except for O-s (r=0.10) and StC7-SVA (r=0.11). Conclusion : The correlation patterns within X-CS and CT-CS were very similar in this study. The correlation between X-ray and CT was statistically significant for most radiological parameters, and the correlation score increased when the horizontal gaze was consistently maintained. The lower cervical parameters were not statistically associated with translation-related parameters (C2-7 SVA and StC7-SVA). Therefore, the upper cervical segment may be a better predictor for determining head and neck translation.

ANALYSIS OF ER:YAG LASER IRRADIATION ON CUTTING EFFICACY AND TEMPERATURE CHANGES OF DENTIN (Er:YAG 레이저의 상아질 삭제효과 및 이에 따른 온도변화)

  • Im, Kwang-Ho;Lee, Chang-Seop;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.1
    • /
    • pp.32-44
    • /
    • 2001
  • The purpose of this study was to investigate the effects of Er : YAG laser on cutting efficacy and temperature changes of dentin. We used the dentin specimens of human premolars and molars which contain the physiologic saline and maintain the pulpal pressure in dentinal tubules. Each specimen was exposed to Er : YAG laser with non-contact handpiece type delivery system under different treatment condition of irradiation energy, pulse repetition rate, and exposure time. Two procedures were conducted by the presence of water flow during lasing. The specimens were grouped by thickness of dentin. We investigated the cavity pattern, volume, and temperature change of dentin specimen to determine the cutting efficacy and temperature rise of Er : YAG laser, and obtained following results. 1. Cutting volume of dentin was increased by increasing the irradiation energy, pulse repetition rate, and exposure time(P<0.05). 2. Margins of abulated cavities were sharp and clean and floors of cavities were conical in shape and showing smooth surfaces. Upper diameter of abulated cavities were increasing as laser parameter of irradiation energy, pulse repetition rate, and exposure time were increased. A few cracks were observed on abulated surfaces under treatment condition of laser parameter with 150mJ, 5Hz, and 5sec. 3. Temperature was increased as laser parameter of irradiation energy, pulse repetition rate, and exposure time were increased, and temperature rise was decreased as dentin thickness was increased(P<0.05). 4. Temperature rise was decreased under water flow compared with no water flow during laser exposure(P<0.05). From these results, we think that the method of using a Er:YAG laser would be effective and safe in cutting dentin for clinical application.

  • PDF

Analysis of fMRI Signal Using Independent Component Analysis (Independent Component Analysis를 이용한 fMRI신호 분석)

  • 문찬홍;나동규;박현욱;유재욱;이은정;변홍식
    • Investigative Magnetic Resonance Imaging
    • /
    • v.3 no.2
    • /
    • pp.188-195
    • /
    • 1999
  • The fMRI signals are composed of many various signals. It is very difficult to find the accurate parameter for the model of fMRI signal containing only neural activity, though we may estimating the signal patterns by the modeling of several signal components. Besides the nose by the physiologic motion, the motion of object and noise of MR instruments make it more difficult to analyze signals of fMRI. Therefore, it is not easy to select an accurate reference data that can accurately reflect neural activity, and the method of an analysis of various signal patterns containing the information of neural activity is an issue of the post-processing methods for fMRI. In the present study, fMRI data was analyzed with the Independent Component Analysis(ICA) method that doesn't need a priori-knowledge or reference data. ICA can be more effective over the analytic method using cross-correlation analysis and can separate the signal patterns of the signals with delayed response or motion related components. The Principal component Analysis (PCA) threshold, wavelet spatial filtering and analysis of a part of whole images can be used for the reduction of the freedom of data before ICA analysis, and these preceding analyses may be useful for a more effective analysis. As a result, ICA method will be effective for the degree of freedom of the data.

  • PDF