• 제목/요약/키워드: Physical wedge

검색결과 103건 처리시간 0.028초

DYNAMIC WEDGE의 임상 적용 가능성에 관한 고찰

  • 김영범;정세영;황웅구
    • 대한방사선치료학회지
    • /
    • 제7권1호
    • /
    • pp.103-110
    • /
    • 1995
  • Dynamic wedge system has been introduced to modify the beam profile and to make homogeneous isodose curves in the mass of irregular shape. Before the clinical use of dynamic wedge, several factors such as wedge transmission factor, dose profile, percent depth dose, and wedge angle have to be measured quantitatively. Film dosimetry is used to evaluate these factors in this study. A comparison of the result of the dynamic wedge to physical wedge system is made. A positive result for the application of the dynamic wedge to clinic is derived even though there is a limitation in accuracy of the dosimetry system used. To measure all factors quantitatively, more accurate dosimetry systems are required.

  • PDF

Rear Foot Wedge 각도가 보행시 전족저 최대압력에 미치는 영향 (The Effect of Rear Foot Wedge Angle on Peak Plantar Pressures on the Forefoot During Walking)

  • 권오윤;정도영;박경희
    • 한국전문물리치료학회지
    • /
    • 제9권3호
    • /
    • pp.11-21
    • /
    • 2002
  • The purpose of this study was to find the effect of rear foot wedge angle on peak plantar pressures on the forefoot during walking. Twenty normal healthy subjects (10 female, 10 male) were recruited. Peak plantar pressure was measured using pressure distribution platforms (MatScan system) in medial forefoot (under the first, second metatarsal head) and lateral forefoot (under the third, fourth, fifth metatarsal head). The subjects walked at the comfortable velocity under seven conditions; bare footed, $5^{\circ}$, $10^{\circ}$ and $15^{\circ}$ wedges under the medial and lateral sides of the hindfoot. The three averaged peak plantar pressures were collected at each condition at stance and toe off phases. The results showed that a significant increase in lateral forefoot plantar peak pressure investigated in the medial wedge and a significant decrease in lateral forefoot plantar peak pressure investigated in lateral wedge at stance phase (p<.05). These results suggest that rear foot wedge may be useful to modify the peak plantar pressure on the forefoot.

  • PDF

도체와 유전체가 복합된 쐐기에 의한 E-편파된 전자파의 회절, II:확장된 회절계수 (E-polarized electromagnetic diffraction by a composite wedge, II:Extended diffraction coefficients)

  • 김세윤;김상욱
    • 전자공학회논문지D
    • /
    • 제34D권7호
    • /
    • pp.1-7
    • /
    • 1997
  • The physical optical solution to the E-polarized diffraction by a composite wedge consisting of perfect conductor and lossless dielectric cannot sayisfy not only the boundary conditions at the wedge interfaces but also the edge condition at the wedge tip. Its diffraction coefficients are extended outside the composite wedge to become the exact solution to the perfectly conducting wedge as its relative dielectric constant increases to infinite or decreases to 1. It is assured that the extended diffraction coefficients approach zero in the arificially complementary region of the composite wedge.

  • PDF

Effects of Combined Wedge on Angle and Moment of Ankle and Knee Joint During Gait in Patients With Genu Varus

  • Yang, Hae Sun;Choi, Houng Sik
    • 국제물리치료학회지
    • /
    • 제7권2호
    • /
    • pp.1025-1030
    • /
    • 2016
  • The purpose of this study was to investigate the effects of combined wedge on the range of motion in ankle and knee joint, ankle eversion moment and knee adduction moment, and center of pressure excursion of foot for genu varus among adult men during gait. This study was carried out with 10 adult men for genu varus in a motion analysis laboratory in J university. The subjects of the experiment were measured above 5cm width between the knees on contact of both medial malleolus of ankle while standing. The width of their knees in neutral position was measured without the inversion or eversion of the subtalar joint by the investigator. The subjects of the experiment were ten who were conducted randomly for standard insole, insole with $10^{\circ}$ lateral on rear foot wedge, insole at $10^{\circ}$lateral on rear foot and $5^{\circ}$ medial on fore foot wedge. Before and after intervention, changes on the range of motion in ankle and knee joint, ankle eversion moment and knee adduction moment, and center of pressure excursion were measured. In order to compare analyses among groups; repeated one-way ANOVA and $Scheff{\acute{e}}$ post hoc test were used. As a result, combined wedge group was significantly decreased compared to control wedge group in terms of knee varus angle in mid-stance(p<.05). Combined wedge group was significantly decreased compared to lateral wedge group in terms of ankle eversion moment in whole stance(p<.05). Combined wedge group was significantly decreased compared to lateral wedge group in terms of knee adduction moment in whole stance(p<.05). Combined wedge group was significantly decreased compared to lateral wedge in terms of center of pressure excursion in whole stance(p<.05). The results of this study suggest that combined wedge for genu varus decreased ankle eversion moment and knee adduction moment upon center of pressure excursion. We hypothesize that combined wedge may also be effective in the protection excessive ankle pronation.

Determination of an Effective Wedge Angle by Combination of Two Arbitrary Universal Wedge Fields in Radiation Therapy of Cancer Patients with Megavoltage Photon Beams

  • Shamsi, Azin;Birgani, Mohammad Javad Tahmasebi;Behrooz, Mohammad Ali;Arvandi, Sholeh;Fatahiasl, Jafar;Maskny, Reza;Abdalvand, Neda
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제17권1호
    • /
    • pp.197-200
    • /
    • 2016
  • Background: Wedge filters are commonly used in radiation oncology for eliminating hot spots and creating a uniform dose distribution in optimizing isodose curves in the target volume for clinical aspects. These are some limited standard physical wedges ($15^{\circ}$, $30^{\circ}$, $45^{\circ}$, $60^{\circ}$),or creating an arbitrary wedge angle, like motorized wedge or dynamic wedge,${\ldots}$ The new formulation is presented by the combination of wedge fields for determining an arbitrary effective wedge angles. The isodose curves also are derived for these wedges. Materials and Methods: we performed the dosimetry of Varian Clinac 2100C/D with Scanditronix Wellhofer water blue phantom, CU500E, OmniPro - Accept software and 0.13cc ionization chamber for 6Mv photon beam in depth of 10cm (reference depth) for universal physical wedges ($15^{\circ}$, $30^{\circ}$, $45^{\circ}$, and $60^{\circ}$) and reference field $10.10cm^2$. By combining the isodose curve standard wedge fields with compatible weighting dose for each field, the effective isodose curve is calculated for any wedge angle. Results: The relation between a given effective wedge angle and the weighting of each combining wedge fields was derived. A good agreement was found between the measured and calculated wedge angles and the maximum deviation did not exceed $3^{\circ}$. The difference between the measured and calculated data decreased when the combined wedge angles were closer. The results are in agreement with the motorized single wedge appliance in the literature. Conclusions: This technique showed that the effective wedge angle that is obtained from this method is adequate for clinical applications and the motorized wedge formalism is a special case of this consideration.

Heuristic Physical Theory of Diffraction for Impedance Polygon

  • Lee, Keunhwa;Park, Sanghyun;Kim, Kookhyun;Seong, Woojae
    • International Journal of Ocean System Engineering
    • /
    • 제3권1호
    • /
    • pp.22-32
    • /
    • 2013
  • A heuristic physical theory of diffraction (PTD) for an acoustic impedance wedge is proposed. This method is based on Ufimtsev's three-dimensional PTD, which is derived for an acoustic soft or hard wedge. We modify the original PTD according to the process of physical optics (or the Kirchhoff approximation) to obtain a 3D heuristic diffraction model for an impedance wedge. In principle, our result is equivalent to Luebbers' model presented in electromagnetism. Moreover, our approach provides a useful insight into the theoretical basis of the existing heuristic diffraction methods. The derived heuristic PTD is applied to an arbitrary impedance polygon, and a simple PTD formula is derived as a supplement to the physical optics formula.

내·외측 Wedge와 넙다리네갈래근 각의 차이가 안쪽빗넓은근/가쪽넓은근 비에 미치는 영향 (Effects of Medial, Lateral Wedge and Difference of Quadriceps Angle on Vastus Medialis Oblique/Vastus Lateralis Muscle Activity Ratios)

  • 유원규;이현주;이충휘
    • 한국전문물리치료학회지
    • /
    • 제12권2호
    • /
    • pp.11-19
    • /
    • 2005
  • Patellofemoral pain syndrome (PFPS) is often attributed to malalignment and maltracking of patella within the patellofemoral joint. Most exercise for PFPS has focused on selectively strengthening the vastus medialis oblique muscle (VMO). This study was designed to identify the effect of medial, lateral wedge and difference of Quadriceps angle (Q-angle) on vastus medialis oblique/vastus lateralis muscle (VL) activity ratios. The subjects were twenty young adult males who had not experienced any knee injury. They were asked to perform isometric contraction exercises in three postures using medial and lateral wedge. The EMG activity of the VL and VMO were recorded in three postures by surface electrodes and normalized by %MVC values derived from seated, isometric knee extensions. The normalized EMG activity levels (%MVC) of the VL and VMO for the three postures of the lower extremities were compared using 2-way repeated measures ANOVA with 1 between-subject factor (group), and 1 within-subject factor (wedge). Results of repeated measures of ANOVA's revealed that the medial wedge isometric contraction exercise produced significantly greater EMG activity of VMO/VL ratios in Group I (Q-angle $18^{\circ}$ or less) (p<.05). But, the medial wedge isometric contraction exercise was no significant difference of VMO/VL ratios in Group II (Q-angle $19^{\circ}$ or more) (p>.05). These results have important implications for selective VMO muscle strengthening exercises in PFPS patients.

  • PDF

쐐기필터 사용 시 레디오크로믹 필름을 이용한 조직에 따른 선량분포 연구 (Dose Distribution According to the Tissue Composition Using Wedge Filter by Radiochromic Film)

  • 김연래;이정우;박병문;정재용;박지연;서태석
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제35권2호
    • /
    • pp.157-164
    • /
    • 2012
  • 본 논문의 목적은 쐐기필터를 사용한 방사선조사면에서 다양한 조직전자밀도가 선량분포에 미치는 영향을 분석하고자 함이다. 구성된 물질에 따라 밀도가 다른 고체 팬텀, 코르크팬텀, 그리고 공기층에서 동적쐐기필터와 금속쐐기필터를 이용하여 선량분포의 변형정도를 평가하였다. 본 실험에서는 매질 내 삽입이 용이하고 우수한 선량특성을 가지고 있는 레디오크로믹 필름(Gafchromic EBT2, International Speciality Products, NJ)을 사용하였다. 선형가속기 6 MV 광자선을 이용해서 $10{\times}10cm^2$ 조사면에 400 MU를 조사하였다. 필름의 선량분포는 선량 분석프로그램을 이용하여 조사면 내 영역과 반음영 영역을 분석하였다. 조직의 밀도가 같을 때 동적쐐기필터와 금속 쐐기필터의 선량분포는 금속 쐐기필터 선량이 동적쐐기필터 선량보다 높게 나타났다. 조직전자밀도가 다른 부위에 쐐기필터의 종류에 따른 선량분포는 고체팬텀과 코르크 팬텀에서 2% 이내 차이를 나타내고 있었다. 그러나 공기층에서 선량분포는 고체팬텀이나 코르크 팬텀의 선량분포와 큰 차이를 보이고 있다. 공기층에서 쐐기필터의 선량분포는 쐐기 사용 효과가 나타나지 않고 있다. 쐐기필터의 두꺼운 부분과 얇은 부분 밖에서 반음영의 크기는 1 cm에서 2 cm 정도 크게 두꺼운 부분에서 크게 나타났다. 그리고 금속 쐐기필터에서 반음영이 동적쐐기필터 보다 평균 6.4%정도 높게 반음영이 나타났다. 본 실험을 통해 공기층과 같이 조직전자밀도 현저히 작은 매질에서는 쐐기필터의 효과가 크게 떨어지는 것과 불균질 물질에 따라 흡수되는 선량분포가 크게 변형되는 것을 알 수 있었다. 따라서 조직전자밀도의 차이가 큰 부위의 방사선치료계획 시 쐐기필터의 적용에 따른 적절한 보정이 이루어져야 한다.

Review of the Hidden Rays of Diffraction

  • Kim, Se-Yun
    • Journal of electromagnetic engineering and science
    • /
    • 제15권1호
    • /
    • pp.1-5
    • /
    • 2015
  • A high-frequency analysis technique, called the hidden rays of diffraction (HRD), is reviewed in this paper. The physical optics and the rigorous diffraction coefficients of a perfectly conducting wedge illuminated by a plane wave are compared. The physical existence of hidden rays on the shadow boundary is explained in view of the geometric theory of diffraction (GTD). In particular, a systematic tracing of hidden rays and its visualization are precisely described by introducing the concept of the supplementary boundary. The physical meaning of the null-field condition in the complementary region is also explained.

Dosimetric Characteristics of 6 MV Modified Beams by Physical Wedges of a Siemens Linear Accelerator

  • Zabihzadeh, Mansour;Birgani, Mohammad Javad Tahmasebi;Hoseini-Ghahfarokhi, Mojtaba;Arvandi, Sholeh;Hoseini, Seyed Mohammad;Fadaei, Mahbube
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제17권4호
    • /
    • pp.1685-1689
    • /
    • 2016
  • Physical wedges still can be used as missing tissue compensators or filters to alter the shape of isodose curves in a target volume to reach an optimal radiotherapy plan without creating a hotspot. The aim of this study was to investigate the dosimetric properties of physical wedges filters such as off-axis photon fluence, photon spectrum, output factor and half value layer. The photon beam quality of a 6 MV Primus Siemens modified by 150 and 450 physical wedges was studied with BEAMnrc Monte Carlo (MC) code. The calculated present depth dose and dose profile curves for open and wedged photon beam were in good agreement with the measurements. Increase of wedge angle increased the beam hardening and this effect was more pronounced at the heal region. Using such an accurate MC model to determine of wedge factors and implementation of it as a calculation algorithm in the future treatment planning systems is recommended.