• Title/Summary/Keyword: Physical protection system

Search Result 212, Processing Time 0.027 seconds

GEOTECHNICAL DESIGNS OF THE SHIP IMPACT PROTECTION SYSTEM FOR INCHEON BRIDGE

  • Choi, Sung-Min;Oh, Seung-Tak;Park, Sang-Il;Kim, Sung-Hwan
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09c
    • /
    • pp.72-77
    • /
    • 2010
  • The Incheon Bridge, which was opened to the traffic in October 2009, is an 18.4 km long sea-crossing bridge connecting the Incheon International Airport with the expressway networks around the Seoul metropolitan area by way of Songdo District of Incheon City. This bridge is an integration of several special featured bridges and the major part of the bridge consists of cable-stayed spans. This marine cable-stayed bridge has a main span of 800 m wide to cross the vessel navigation channel in and out of the Incheon Port. In waterways where ship collision is anticipated, bridges shall be designed to resist ship impact forces, and/or, adequately protected by ship impact protection (SIP) systems. For the Incheon Bridge, large diameter circular dolphins as SIP were made at 44 locations of the both side of the main span around the piers of the cable-stayed bridge span. This world's largest dolphin-type SIP system protects the bridge against the collision with 100,000 DWT tanker navigating the channel with speed of 10 knots. Diameter of the dolphin is up to 25 m. Vessel collision risk was assessed by probability based analysis with AASHTO Method-II. The annual frequency of bridge collapse through the risk analysis for 71,370 cases of the impact scenario was less than $0.5{\times}10^{-4}$ and satisfies design requirements. The dolphin is the circular sheet pile structure filled with crushed rock and closed at the top with a robust concrete cap. The structural design was performed with numerical analyses of which constitutional model was verified by the physical model experiment using the geo-centrifugal testing equipment. 3D non-linear finite element models were used to analyze the structural response and energy-dissipating capability of dolphins which were deeply embedded in the seabed. The dolphin structure secures external stability and internal stability for ordinary loads such as wave and current pressure. Considering failure mechanism, stability assessment was performed for the strength limit state and service limit state of the dolphins. The friction angle of the crushed stone as a filling material was reduced to $38^{\circ}$ considering the possibility of contracting behavior as the impact.

  • PDF

An Audit Model for Information Security of Hospital Information System (병원정보시스템에서의 정보보호를 위한 감리모형)

  • Yu, Wan Hee;Han, Ki Joon;Kim, Dong Soo;Kim, Hee Wan
    • Journal of Digital Convergence
    • /
    • v.12 no.7
    • /
    • pp.133-145
    • /
    • 2014
  • Recently, Hospital information systems have the large databases by wide range offices for hospital management, health care to improve the quality of care. However, hospital information systems for information security measures are insufficient. Therefore, when we construct the hospital information system, we have to audit the information security measures for them, and we have to manage the ISMS(Information Security Management System) to maintain the information protection level through the risk managements. In this paper, we suggested the hospital information security audit model for the protection of health information privacy by the current hospital information systems, information security management system(ISMS), and hospital information security requirements and threats. We derived the check items compared with ISO27799 reflected the characteristics of the hospital. We classified the security domains as the physical, technical, administrative domain, and derived the check items for information security. We also designed the check lists by mapping the ISO27799 risk management process to improve the security and efficiency simultaneously. Our model by the five-point scale survey of IT experts was verified the suitability with the average of 4.91 points.

Technical and Managerial Requirements for Privacy Protection Using Face Detection and Recognition in CCTV Systems (영상감시 시스템에서의 얼굴 영상 정보보호를 위한 기술적·관리적 요구사항)

  • Shin, Yong-Nyuo;Chun, Myung Geun
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.24 no.1
    • /
    • pp.97-106
    • /
    • 2014
  • CCTV(Closed Circuit television) is one of the widely used physical security technologies and video acquisition device installed at specific point with various purposes. Recently, as the CCTV capabilities improve, facial recognition from the information collected from CCTV video is under development. However, in case these technologies are exploited, concerns on major privacy infringement are high. Especially, a computer connected to a particular space images taken by the camera in real time over the Internet has emerged to show information services. In the privacy law, safety measures which is related with biometric template are notified. Accordingly, in this paper, for the protection of privacy video information in the video surveillance system, the technical and managerial requirements for video information security are suggested.

Hydraulic Characteristic Analysis of Buoyant Flap Typed Storm Surge Barrier using FLOW-3D model (FLOW-3D 모형을 이용한 부유 플랩형 고조방파제의 수리학적 특성 분석)

  • Ko, Dong Hui;Jeong, Shin Taek;Kim, Jeong Dae
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.26 no.3
    • /
    • pp.140-148
    • /
    • 2014
  • A storm surge barrier is a specific type of floodgate, designed to prevent a storm surge or spring tide from flooding the protected area behind the barrier. A surge barrier is almost always part of a larger flood protection system consisting of floodwalls, dikes, and other constructions. Surge barriers allow water to pass under normal circumstances but, when a (storm) surge is expected, the barrier can be closed. Among the various means of closing, buoyant flap typed storm surge barrier which was indicated by MOSE project in Italy is chosen for Masan bay protection, and the motion of the surge barrier under the action of storm surge and wave is examined using FLOW-3D, a computational fluid dynamics software analyzing various physical flow processes. Numerical result shows that storm surge barrier is successfully operated under wave height 3 m, and tidal range 2 m.

A Secure Technique Design for Privacy Protection in RFID System (RFID 시스템에서 프라이버시 보호를 위한 보안기법 설계)

  • Oh, Gi-Oug;Park, Mi-Og
    • Journal of the Korea Society of Computer and Information
    • /
    • v.15 no.8
    • /
    • pp.107-115
    • /
    • 2010
  • RFID (Radio Frequency IDentification) technology, automatic identification and data capture technologies in ubiquitous computing is an essential skill. Low-cost Radio Frequency Identification tags using memory and no physical contact due to the ease of use and maintenance of excellence are going to use expanded. However, it is possible to the illegal acquisition of the information between RFID tags and readers because RFID uses the RF signal, and the obtained information can be used for the purpose of location tracking and invasion of privacy. In this paper, we proposed the security scheme to protect against the illegal user location tracking and invasion of privacy. The security scheme proposed in this paper, using Gray Code and reduced the capacity of the calculation of the actual tags, However, it is impossible for the malicious attacker to track information because tag information transmitted from the reader is not fixed. Therefore, even if the tags information is obtained by a malicious way, our scheme provides more simple and safe user privacy than any other protection methods to protect user privacy, because not actual information but encrypted information is becoming exposed.

Wet Flashover Characteristics and Reform Measure of a Conventional Lightning Rod against Lightning Impulse Voltages (뇌임펄스전압에 대한 돌침형 피뢰침의 주수섬락특성과 개선 방안)

  • 이복희;강석만;엄주홍;이승칠;김승지
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.3
    • /
    • pp.93-100
    • /
    • 2002
  • In this paper, in ordor to examine the relevant technical facts which are very instructive to revise the domestic standard for lightning protection systems, standards and technical guideline for the protection of structure against lightning were reviewed, and several issues of the domestic standards were experimentally investigated. As a consequence, the insulator of relatively low implse voltage and a large percentage of lighting rods is flashovered by relatively low impulse voltage and a lage percentage of lighting current flows through supporting mast. Thus the potential gradient in the vicinity of supporter for lighting rods is extremely increased and the role of lighting propection systems is nullified. It seems obvious that the flashover of insular supporting lighting rod can range from erratic operation of microelectronic devices to minor physical ham or even death, or costly damage electrical equipment.

Evaluation of Firefighting Gloves and the Behavior Regarding their Usage, of Firefighting Officials in Seoul (서울시 소방공무원의 방화장갑에 대한 평가 및 사용실태)

  • Kim, Do-Hee;Nam, Kibum;Oh, Jung-Woo;Lee, Joo-Young
    • Fashion & Textile Research Journal
    • /
    • v.23 no.4
    • /
    • pp.515-526
    • /
    • 2021
  • This study aimed to investigate the evaluation of firefighting gloves and the behavior regarding their usage, of firefighting officials in Seoul, using a questionnaire. Responses from a total of 270 firefighters who are responsible for putting out fires or undertaking rescue works in Seoul were analyzed. As per the findings, the firefighters considered ease of hand operation and fire/flame protection as the most important performance factors for firefighting gloves, and they were satisfied with the supply status of the gloves. The average number of firefighting gloves currently owned by the firefighters was 2.6 ± 0.8 pairs. Thirty-nine percent of the respondents said that their firefighting gloves lasted, with maintained performance, for more than six months and less than a year, and when asked how they handled the gloves with degraded performance, 46% of them said that they would discard them. Sixty-eight percent of the respondents said that they used the most recently developed and supplied gloves, which they considered as the most satisfying gloves and which they mainly used these days. Respondents were highly satisfied with the fire/flame protection performance of their firefighting gloves, but were less satisfied, however, with the glove fit. These results suggest that there has been a significant improvement in the overall performance level and supply status of the firefighting gloves. Given the current situation, careful considerations with flexible approaches are needed on the current firefighting gloves size system as well as on the personal protective equipment maintenance and management scheme.

The implementation of Smart Care System for Dementia Patients (치매 환자를 위한 스마트 캐어 시스템 구현)

  • Ha, Eun-Sil
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.6
    • /
    • pp.3832-3840
    • /
    • 2014
  • The rapidly aging population is also increasing the number of dementia patients rapidly. Studies have revealed the early signs of slowing progress. Therefore, dementia patient safety, continuous care, daily living, and health care are becoming more important. In this paper, a smart home care system using smart phones and Bluetooth communication technology was used to monitor the state of dementia patients of based on the results of grading dementia, health care of the dementia patients at home and provide for the safety of the system using motion sensors and gas leak sensors to respond to various emergency situations, such as fire, gas leak protection, and loitering. Using this system, the patient can stay longer in their home due to the nature of Korean culture before admission, while reducing the family's economical, physical and psychological burden and allowing the consultation of specialists through the system by building a database of individuals and providing professional service and specialty care referral agencies through the link.

Assessment of Evaluation by Hybrid Waterproof-Roof Barrier Layer for Green System on Artificial Ground (인공지반 녹화시스템 활용을 위한 일체형 방수·방근 시트의 성능평가)

  • Oh, Chang-Won;Hong, Jong-Chul;Park, Ki-Bong
    • Journal of the Korea Institute of Building Construction
    • /
    • v.15 no.4
    • /
    • pp.391-396
    • /
    • 2015
  • The demands about eco friendly space are increased as buildings are denser in downtown, and green system on the roof and the artificial ground are widely being applied. The construction of green system applies a waterproof layer, a root barrier and a protection concrete layer. Assembly of these many layers leads to a long construction term, and cause many defects. This study is to evaluate one layer-hybrid sheet which gets waterproof and root barrier performance simultaneously, which is developed to use in the new green system. As results, the performances of physical properties, durability, waterproof and root barrier not only exceeded quality standards but also showed excellent durability. In addition, mock-up test would be proceed to certify long term performance.

Development of the Integrative System to Categorize Damaged Areas for Participatory Restoration by Local Residents (주민참여형 복원을 위한 훼손지의 통합적 유형 구분 체계 개발)

  • Ahn, Tong Mahn;Kim, In Ho;Choi, Hyung Suk;Lee, Jae Young;Lee, Ji Young;Lee, Young;Ryu, Sun Jung;Min, So Young;Yoon, Min Ho
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.11 no.2
    • /
    • pp.87-103
    • /
    • 2008
  • Despite its high level of symbolic and ecological values, BaigDooDaeGahn, about 684km long stretch of mountains in the eastern part of Korean peninsular, has been widely destroyed and barely recovered. While Korean government enacted a special law in 2005 to protect these areas and designated about 2,658 $km^2$ as the protection zone in 2007, there were a number of sites inside that had been disturbed by mining, illegal crop cultivations, stone quarry, development of resort facilities, construction of roads, and other human activities. To restore these damaged areas in a sustainable manner, the integrative system to categorize damaged areas for participatory restoration by local residents was suggested by this study. The most distinguished feature of the proposed system was to integrate the existing restoration approach focusing on biophysical conditions into the sustainability-building approach to reactivate socio-economic conditions of local society, called 'restoration of eco-cultural community'. As an entry stage to design the new restoration system including processes and procedures, the damaged areas had to be re-categorized by two characteristics, their physical conditions in terms of possibility of public participatory restoration and the readiness of local society required for pursuing endogenous development. More detailed considerations regarding these two characteristics and three different categories has been suggested and discussed.