Although many current low back pain exercise incorporate proprioceptive training, very little research has been performed on proprioception of the low back. To determine wether reposition error is different in male than female. Eighteen young individuals took part in the research, seven male and eleven female. The 3-dimensional position of the lumbar was measured with a CMS70P. Reposition error was calculated as the absolute difference between the neutral position and return position. No significant differences in reposition error were found between male and female. No significant correlations were identified between reposition error and movement direction.
A bibliographical review of Gy sampling theory for particulate materials was conducted to provide readers with useful means to reduce errors in soil contamination investigation. According to the Gy theory, the errors caused by the heterogeneous nature of soil include; the fundamental error (FE) caused by physical and chemical constitutional heterogeneity, the grouping and segregation error (GE) aroused from gravitational force, long-range heterogeneous fluctuation error ($CE_2$), the periodic heterogeneity fluctuation error ($CE_3$), and the materialization error (ME) generated during physical process of sample treatment. However, the accurate estimation of $CE_2$ and $CE_3$ cannot be estimated easily and only increasing sampling locations can reduce the magnitude of the errors. In addition, incremental sampling is the only method to reduce GE while grab sampling should be avoided as it introduces uncertainty and errors to the sampling process. Correct preparation and operation of sampling tools are important factors in reducing the incremental delimitation error (DE) and extraction error (EE) which are resulted from physical processes in the sampling. Therefore, Gy sampling theory can be used efficiently in planning a strategy for soil investigations of non-volatile and non-reactive samples.
Purpose : The purpose of this study was to compare trunk repositioning errors between subjects with and without low back pain in sitting and standing. Methods : Total 81 participants were recruited who consisted of 41 subjects with low back pain and 40 normal subjects. The subjects were instructed to replicate the predetermined target positions of the trunk toward upright and $30^{\circ}$ flexion in sitting and standing. During each of movement, digital inclinometer was used to measure the angular movement of $T_{12}$ spinal process. Repositioning error was calculated as the absolute difference between the predetermined target positions and replicated target positions. Results : In subjects with low back pain, upright repositioning error was $1.26^{\circ}{\pm}0.14^{\circ}$ in sitting and $1.55^{\circ}{\pm}0.24^{\circ}$ in standing, and $30^{\circ}$ flexion repositioning error was $3.23^{\circ}{\pm}0.33^{\circ}$ in sitting and $5.50^{\circ}{\pm}0.50^{\circ}$ in standing. In subjects without low back pain, upright repositioning error was $1.38^{\circ}{\pm}0.15^{\circ}$ in sitting and $1.67^{\circ}{\pm}0.18^{\circ}$ in standing, and flexion repositioning error was $2.61^{\circ}{\pm}0.28^{\circ}$ in sitting and $3.70^{\circ}{\pm}0.52^{\circ}$ in standing. It was demonstrated that flexion repositioning error increased significantly in standing position. In subjects with low back pain, $30^{\circ}$ flexion repositioning error was significantly higher in standing than in sitting. Conclusion : The repositioning error of subjects with low back pain increased during flexion and it implies that some aspects of proprioception are decreased in subjects with low back pain. Therefore, it will be emphasis that a clinical trial to increase the trunk flexion stability of subjects with low back pain in standing.
Basis frame-work's base in a semiconductor industry have gas, chemical, electricity and various facilities in bring to it. That it is a foundation by fire, power failure, blast, spill of toxicant huge by large size accident human and physical loss and damage because it can bring this efficient, connect with each kind mechanical, physical thing to prevent usefully need that control finding achievement factor of human factor of human action. Large size accident in a semiconductor industry to machine and human and it is involved that present, in system by safety interlock defect of machine is conclusion for error of behaviour. What is not construing in this study, do safety in a semiconductor industry to do improvement. Control human error analyzes in human control with and considers mechanical element and several elements. Also, apply achievement factor using O'conner Model by control method of human error. In analyze by failure mode effect using actuality example.
The purpose of this study was to assess the influence of the duration of smartphone usage on cervical and lumbar spine flexion angles and reposition error in the cervical spine. The study included 18 healthy smartphone users (7 males and 11 females). We measured the kinematics of the upper and lower cervical and lumbar spine flexion angles and the reposition error of the upper and lower cervical spine after 3 s and 300 s smartphone use in sitting. A paired t-test was used to compare the effects of the duration of smartphone usage on the kinematics of cervical and lumbar spine flexion angles and reposition error. The flexion angles of the lower cervical and lumbar spine and the reposition error in the upper and lower cervical spine were significantly increased after 300 s smartphone of use (p<.05). However, the flexion angle of the upper cervical spine was not significantly different between the 3 s and 300 s smartphone of use (p>.05). These findings suggest that prolonged use of smartphones can induce changes in cervical and lumbar spine posture and proprioception in the cervical spine.
Purpose: The purpose of this study was to investigate the immediate effects of calf muscle Kinesio taping on ankle joint reposition sense (JRS) and force sense (FS) in healthy elderly. Methods: Thirteen healthy elderly subjects were participated in this study. The error of ankle JRS and FS was evaluated by 3D motion capture device and digital dynamometer depending on three different taping conditions (Kinesio taping, sham taping, and no taping) respectively. All of subjects were asked to perform a proprioceptive task of ankle JRS and FS. One-way repeated ANOVA test was used to compare the error of JRS and FS depending on three different taping conditions. Results: With Kinesio taping over calf muscle, ankle joint reposition sense error and force sense error significantly decreased, if compared with a sham taping or no taping condition. Conclusion: To apply Kinesio taping over calf muscle could enhance ankle proprioceptive sense in the elderly people.
Purpose: The purpose of this is to identify the relationship among the age, body mass index(BMI) and exercise frequency(EF) with knee joint position sense in korean healthy women. Methods: Healthy women of 328 who participated in this study were tested knee joint position sense; reposition error was measured with a Myrin goniometer. Each reposition error was analyzed using descriptive statics, pearson correlation coefficients, and stepwise multiple regression. Results: The mean reposition error by age groups was significant decrease getting older. The mean reposition error by BMI groups was significant decrease getting higher. And the mean reposition error by EF groups was significant decrease getting lower. The knee joint position sense showed a significantly correlation with age(r=0.36, p=.00), BMI(r=0.34, p=.00) and EF(r=-0.50, p=.00). The most powerful predictor of knee joint position sense was EF. The reposition error according to stepwise multiple regression is $3.36+(-2.64){\times}EF+0.13{\times}age$, and account for 46%($R^2=0.46$) of the variance in the knee joint position sense. Conclusion: The older the women are, for prevent of knee injuries due to decreased joint position sense, regular exercise is essential factor.
Purpose: Most studies have reported pain in the head-neck and upper-limbs according to smartphone usage, which is related to the proprioception sense in the head and neck, but there have been few studies. Therefore, the aim of this study was identify the adverse effects of the proprioceptive sense in the head-neck according to smartphone usage. Methods: Twenty-seven young adults (male: 9, female: 18) were enrolled in this study. The proprioceptive sense was measured through the joint reposition sense error and neural positon error in the head-neck during smartphone usage for 0, 5, and 20 minutes. The Noraxon MyoMotion system was used to record the joint position angle and neutral positon in the head-neck. One-way repeated ANOVA was used to identify the differences between the three smartphone use durations and the least-squares difference was used as a post hoc test. The data were analyzed using SPSS 18.0 software. Results: The joint reposition sense error and neural positon error in the head-neck were significantly different among the 0, 5, and 20 minutes of smartphone usage (p<0.05). In the post hoc test, the joint reposition sense error and neural positon error showed a significant difference between smartphone use for 0 minute and 5 minute, and between smartphone use for 0 minute and 20 minutes. Conclusion: This study suggests that smartphone use within 5 minutes can have adverse effects on the proprioceptive sense. Therefore, it is necessary to consider the appropriate use time and break time when using smart phones.
Background and Purpose : This study was to analysis effects of muscle fatigue on error of elbow joint sense. Methods : A total 19 healthy student(men = 10, women = 9) who did't have any problem of musculoskeletal system in upper extremities participated this study. we divided two groups into young group(n = 10, $19.67{\pm}.5$) and old group(n = 9, $28.56{\pm}1.5$). In order to evoke muscle fatigue of elbow flexor, we used Biodex, and participations performed concentric contraction of elbow flexor 150 numbers as well as we measured error of joint sense using by Biodex. We collected data just after, 30min, 2hour, 24hour after evoked muscle fatigue, and we finanlly acquired average value of three times measured joint sense of elbow joint. And we calculated value of percentage of error of joint sense. We analyzed collected data by repeated ANOVA, ANOVA using by SPSS ver.12.0 program. Result : This study showed that there was no significantly effects between groups and within groups, we could see that there was significantly difference among duration by each group of age, and sex(p<.05). Conclusion : The error of joint position sense presented highest value just period after evoked muscle fatigue compared after 30 min, 2 hours, 24 hours, and we can't find out interaction between duration and age and sex.
This study examined the correlation between power error (PE) and velocity error (VE) according to the condition and frequency of self-controlled feedback (SCF) during knee extension. One hundred participants were randomly assigned to 30% SCF, 70% SCF, 30% yoked feedback (YF), 70% YF and control group, respectively. The SCF group was provided with feedback when they requested it, whereas the YF group did not influence the feedback schedule. Participants in the control group were not given any visual feedback during the experiment. The isotonic, isometric, and isokinetic dynamometer (PRIMUS RS, BTE, USA) was used to measure the power and velocity error during knee extension. The collected data was analyzed using a Pearson test and SPSS 21.0. The correlation between PE and VE according to the condition and frequency of feedback on each phase during knee extension was significant. Both PE and VE were significantly higher when the feedback was provided with high frequency, passive, and no feedback. Our study suggests that application of SCF can help to improve the proprioception of the healthy person while reducing errors through low frequency and active feedback.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.