• Title/Summary/Keyword: Physical distance

Search Result 1,259, Processing Time 0.029 seconds

Analysis on the Relative Importance and Priority in Speech Therapy Center of Parents of Children with Disabilities (장애아 부모의 언어치료실 선택속성 분석)

  • Kim, Sun;Hong, Gyung Hun
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.3
    • /
    • pp.444-455
    • /
    • 2013
  • The purpose of this study is to explore the selection attributes for parents of children with language disability when choosing a clinic. The data collection was carried out in 3 steps: the preliminary survey, first open survey and second survey in AHP(Analytic Hierarchy Process). The subjects of were 252 in total. The results were as follows: First, The order of priority attributes in superior categories for parents of children with language disability when selecting a clinic were 'therapist-related attributes', 'program-related attributes' and 'physical-related attributes' in turn. The top 5 priority attributes in subcategories were 'therapist's academic background and major', 'ability to make a rapport', 'clinical experience and qualification of therapist', 'kindness and confidence' and 'counseling program for parents'. Second, The parents of preschoolers age 6 and younger chose 'clinical experience and qualification of therapist', 'counseling program for parents' and 'learning materials' for the most priority attributes, whereas the parents of students age from 7 to 12, considered 'therapist's academic background and major', 'clinical fee' and 'distance transport parking' more importantly to select a clinic. The results of this study provided preliminary data for successful planning of speech and language therapy.

A study on the relationship between the movement of animation and heritage of modern mechanism (애니메이션의 움직임과 근대 기계론 전통의 상관관계 연구)

  • Kim, Takhoon;Han, Tae-Sik
    • Cartoon and Animation Studies
    • /
    • s.30
    • /
    • pp.27-57
    • /
    • 2013
  • Animation which appeared with films in the late 19th century was a medium which came on obtaining nourishment from art historical style of modernism. However, the relation establishment between animation and modernism has been focused mainly on animation shapes, namely painted images. This sprang from explaining the relationship between animation and paintings, and for this reason, discussions of movements in animation were understood in tradition of chromophotograph of Muybridge and Jules Marey, or some characteristics owned by the live-action film. However, movements of animation were essentially different from the indexical sign of films or photogram, and objects of reproduction were different between them. Movements reproduced by animation are not ordinary movements, but expressions of or compressed movements and considerably systematic movements. As a result, these movements are far from reproduction of live-action film photogram. Rather, the logic of movements reproduced by animation comes near to controlling their motion scopes, time, distance etc. after dividing each part of the body. This is concluded in a standpoint of modern mechanism which is represented by Descartes and La Mettrie who tried to understand human body as a exchangeable machine. Design of modern mechanism ranging from modern society to industrial society and the age of modernism came to lead to analysis of physical motions of modern industrial society called composition of efficient movements understanding them as the law of nature rather than movements as nature. In the late 19th century, Taylor, F. W. and Gilbreth, Frank Bunker's studies of workers' working hours and 'motion study' were a way of constituting the frame of machine-human, which indicates that tradition of modern mechanism affected the entire modernism passing through industrial society. Further, we can see that motion studies conducted by them have almost similar characteristics to action analysis to study animation later in the name of 'timing'.

Characteristics of Electrolyzed Water Manufactured from Various Electrolytic Diaphragm and Electrolyte (전기분해 격막 및 전해액에 따른 전해수의 특성 비교)

  • 정진웅;김종훈;김병삼;정승원
    • Food Science and Preservation
    • /
    • v.10 no.1
    • /
    • pp.99-105
    • /
    • 2003
  • This study was carried out to investigate the efficacy of surface sterilization and the physicochemical properties of electrolyzed water manufactured from various electrolytic diaphragm and electrolyte. Physical properties of electrolyzed water manufactured from the diaphragm system were the most effective at the following conditions; the distance between diaphragms was 1.0 mm and the supplying rate of 20% NaCl was 6 mL/min. The ORP, HClO content and pH at above conditions were 1,170 mV, 100 ppm and 2.5, respectively. And two stage electrolyzed system was more effective than one stage electrolyzed water manufactured from non-diaphragm system, with 4 mL/min supplying rate of 20% NaCl, was similar to the most effective diaphragm system. But ORP, HClO content and pH were abut 800 mV, 200 ppm and 9 level, respectively. Sealed electrolyzed water could be preserved more than one month at room temperature with ORP of 750 mV in non-diaphragm system and 1,150 mV in diaphragm system, and HClO content of 100 ppm. Twelve kinds of microorganism tested were sterilized within 30 seconds from initial total counts of 10$\^$5/∼10$\^$6/cfu/ml by electrolyzed water. Though the ORP and HCIO contents of electrolyzed water manufactured from various electrolyte were higher in order of NaCl>KCl>CaCl$_2$, there were no difference between the electyolytes in the efficacy of sterilization. Salmonella typhi and Vibrio Proteolyticus were also sterilized by electrolyzed water manufactured from elctrolytes of NaCl CaC1$_2$and KCl

A study on the spectacles-wearing and eyesight health behavior of the middle school students (서울시내 일부 중학생의 시력 및 안경착용과 그에 따른 보건행태 조사연구)

  • Jeon, Ye-Jin;Kim, Myung
    • Korean Journal of Health Education and Promotion
    • /
    • v.11 no.2
    • /
    • pp.87-106
    • /
    • 1994
  • Owing to the use of many cultural facilities, the elevation of life standards and the high level progress of industry, visual impairment was on increasing trends. Especially due to studying for many hours, the myopia of adolescents became a serious social issue. The purpose of this study was to understand adolescent's wearing glasses and eyesight condition, whether the primary myopia factor and the subjective symptoms were different between the myopia group and the normal group, between the wearing glasses group and the non-wearing glasses group, and the effect on physical, mental and study activity of myopia. The subject of investigation was 627 middle school students in Seoul and the investigation was accomplished from July 7th, 1993 to July 12th, 1993. The data were analyzed by the percentage, x²-test, t-test and ANOVA of SPSS. The results were as followed; 1. The rate of the right and left eyesights higher than 0.8 in the normal group was 47.0%, and those less than 0.7 in the myopia group was 53.0%. In the boy students, the normal group was 54.1%, the myopia group was 45.9%. In the girl students, the normal group was 39.2%, the myopia group was 60.8%. Therefore the girl students' myopia rates were higher than the boy students', and this result was significant(p<0.01). 2. The rate of wearing glasses of the middle school students was 44.6%. The rate of wearing glasses of the girl students was 56.8%. The rate of wearing glasses of the girl students was higher than that of the boy students 43.2%. The rate of necessary glasses of the middle school students was 6.1% and the rate of necessary glasses of the boy students was 7.9%, the rate of necessary glasses of the girl students was 4.1%. 3. In case of a family member of the student wear glasses, the rate of wearing glasses was higher. 4. In the myopia group, the main reason for not wearing glasses was "Uncomfortable"(63.3% in the boy students, 40% in the girl students). In case of the girl students, "Nonpermission of their parents" was 18.7% and remarkably higher than 5.1% in case of the boy students. 5. The factor of myopia was that "The bad attitude of watching TV closely" was 19.9%, that "The dimly-lit room" was 6.6%. 6. In order to protect eyesight, the rate of the students who practiced "Looking at something from afar 3∼4times a day" was 37.3%, the rate of the students who did "Eye exercise" was 17.5%, the rate of the students who took "A medicine for promoting nutrition" was 12.9%. The rate of taking the medicine was higher than 3.5% in the normal eyesight group. 7. After near working, the point of subjective symptoms was higher in the myopia group than in the normal group and in the wearing glasses group than in the unwearing group and in the girl students than in the boy students. 8. The longer time to watch TV, the higher point of subjective symptoms. The longer distance to watch TV, the lower point of subjective symptoms(p<0.05).

  • PDF

Cluster Topology Algorithm for Efficient Data Transmission in Wireless Body Area Network based on Mobile Sink (WBAN 환경에서 효율적인 데이터 전송을 위한 모바일 싱크기반의 클러스터 토폴로지 알고리즘)

  • Lee, Jun-Hyuk
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.49 no.12
    • /
    • pp.56-63
    • /
    • 2012
  • The WBAN technology means a short distance wireless network which provides each device interactive communication by connecting devices inside and outside of body. Standardization on the physical layer, data link layer, network layer and application layer is in progress by IEEE 802.15.6 TG BAN. Wireless body area network is usually configured in energy efficient using sensor and zigbee device due to the power limitation and the characteristics of human body. Wireless sensor network consist of sensor field and sink node. Sensor field are composed a lot of sensor node and sink node collect sensing data. Wireless sensor network has capacity of the self constitution by protocol where placed in large area without fixed position. Mobile sink node distribute energy consumption therefore network life time was increased than fixed sink node. The energy efficient is important matter in wireless body area network because energy resource was limited on sensor node. In this paper we proposed cluster topology algorithm for efficient data transmission in wireless body area network based mobile sink. The proposed algorithm show good performance under the advantage of grid routing protocol and TDMA scheduling that minimized overlap area on cluster and reduced amount of data on cluster header in error prone wireless sensor network based on mobile sink.

Finite Element Stress Analysis of Implant Prosthesis according to Position and Direction of Load (하중의 위치 및 경사에 따른 임플랜트 보철의 유한요소법적 응력분석)

  • Bae, Sook-Jin;Chung, Chae-Heon;Jeong, Seung-Mi
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.19 no.4
    • /
    • pp.257-268
    • /
    • 2003
  • The purpose of this study was to assess the loading distributing characteristics of implant prosthesis according to position and direction of load, under vertical and inclined loading using FEA analysis. The finite element model was designed according to standard fixture (4.1mm restorative component x 11.5mm length). The crown for mandibular first molar was made using UCLA abutment. Each three-dimensional finite element model was created with the physical properties of the implant and surrounding bone. This study simulated loads of 200N at the central fossa in a vertical direction (loading condition A), 200N at the outside point of the central fossa with resin filling into screw hole in a vertical direction (loading condition B), 200N at the centric usp in a $15^{\circ}$ inward oblique direction (loading condition C), 200N at the in a $30^{\circ}$ inward oblique direction (loading condition D) or 200N at the centric cusp in a $30^{\circ}$ outward oblique direction (loading condition E) individually. Von Mises stresses were recorded and compared in the supporting bone, fixture, and abutment screw. The following results have been made based on this study: 1. Stresses were concentrated mainly at the ridge crest around implant in both vertical and oblique loading but stresses in the cancellous bone were low in both vertical and oblique loading. 2. Bending moments resulting from non-axial loading of dental implants caused stress concentrations on cortical bone. The magnitude of the stress was greater with the oblique loading than with the vertical loading. 3. An offset of the vertical occlusal force in the buccolingual direction relative to the implant axis gave rise to increased bending of the implant. 4. The relative positions of the resultant line of force from occlusal contact and the center of rotation seems to be more important. 5. The magnitude of the stress in the supporting bone, fixture and abutment screw was greater with the outward oblique loading than with the inward oblique loading and was the greatest under loading at the centric cusp in a $30^{\circ}$ outward oblique direction. Conclusively, this study provides evidence that bending moments resulting from non-axial loading of dental implants caused stress concentrations on cortical bone. But it seems to be more important that how long is the distance from center of rotation of the implant itself to the resultant line of force from occlusal contact(leverage). The goal of improving implants should be to avoid bending of the implant.

Finite Element Stress Analysis of Implant Prosthesis of Internal Connection System According to Position and Direction of Load (임플랜트-지대주의 내측연결 시스템에서 하중의 위치 및 경사에 따른 임플랜트 보철의 유한요소 응력분석)

  • Jang, Jong-Seok;Jeong, Yong-Tae;Chung, Chae-Heon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.21 no.1
    • /
    • pp.1-14
    • /
    • 2005
  • The purpose of this study was to assess the loading distributing characteristics of implant prosthesis of internal connection system(ITI system) according to position and direction of load, under vertical and inclined loading using finite element analysis (FEA). The finite element model of a synOcta implant and a solid abutment with $8^{\circ}$ internal conical joint used by the ITI implant was constructed. The gold crown for mandibular first molar was made on solid abutment. Each three-dimensional finite element model was created with the physical properties of the implant and surrounding bone. This study simulated loads of 200N at the central fossa in a vertical direction (loading condition A), 200N at the outside point of the central fossa with resin filling into screw hole in a vertical direction (loading condition B), 200N at the centric cusp in a $15^{\circ}$ inward oblique direction (loading condition C), 200N at the in a $30^{\circ}$ inward oblique direction (loading condition D) or 200N at the centric cusp in a $30^{\circ}$ outward oblique direction (loading condition E) individually. Von Mises stresses were recorded and compared in the supporting bone, fixture, and abutment. The following results have been made based on this study: 1. Stresses were concentrated mainly at the ridge crest around implant under both vertical and oblique loading but stresses in the cancellous bone were low under both vertical and oblique loading. 2. Bending moments resulting from non-axial loading of dental implants caused stress concentrations on cortical bone. The magnitude of the stress was greater with the oblique loading than with the vertical loading. 3. An offset of the vertical occlusal force in the buccolingual direction relative to the implant axis gave rise to increased bending of the implant. So, the relative positions of the resultant line of force from occlusal contact and the center of rotation seems to be more important. 4. In this internal conical joint, vertical and oblique loads were resisted mainly by the implant-abutment joint at the screw level and by the implant collar. Conclusively, It seems to be more important that how long the distance is from center of rotation of the implant itself to the resultant line of force from occlusal contact (leverage). In a morse taper implant, vertical and oblique loads are resisted mainly by the implant-abutment joint at the screw level and by the implant collar. This type of implant-abutment connection can also distribute forces deeper within the implant and shield the retention screw from excessive loading. Lateral forces are transmitted directly to the walls of the implant and the implant abutment mating bevels, providing greater resistance to interface opening.

Effect of Fluoride and Laser on Artificial Caries-like Lesion Formation in Bovine Enamel (불소 및 레이저가 우치법랑질의 인공우식병소에 미치는 영향)

  • Kim, Jae-Gon;Baik, Byeong-Ju;Ju, Hoon;Yun, Hyun-Du
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.24 no.3
    • /
    • pp.660-677
    • /
    • 1997
  • The purpose of this study was to examine the morphological characteristics and combined effects of fluoride application and laser irradiation on artificial caries-like lesion formation in bovine enamel. Enamel specimens were divided into five experiment group and placed in no-treatment(group C), APF application alone(group F), laser irradiation alone(group L), APF application before laser irradiation (group FL), and APF application after laser irradiation(group LF) on artificial caries-like lesion. Sound enamel was used as a control group. The ultrastructural changes and physical effects of the fluorided and lased enamel has been investigated by using SEM, enamel solubility and microhardness test as well as distributions of calcium, phosphorus and fluoride in internal enamel by using EPMA. The following results were obtained. 1. In the all experiment groups, the amounts of dissolved calcium of enamel surfaces significantly decreased according to increasing exposure time of acid solution than control group(P<0.001). Group L showed higher than that group FL and LF in 30 and 60min(P<0.05). 2. The microhardness values of enamel surface in the control group was highest than that in the other experiment groups. Group F, L, FL and LF were significantly increased than group C(P<0.001). The enamel surface treated with APF produced deposites of numerous small globules and lased enamel showed a cracker-like appearance with microcrack and small pore. Numerous deposits were infiltrated in the fissured portion of enamel treated with APF after laser irradiation. 4. In the case of APF application alone, the elevation of the fluoride profile can be seen within $5{\mu}m$ of the outermost layer and a similar profile observed in the specimen treated with APF before laser irradiation. However, the specimen treated with APF after laser Irradiation showed a large elevation within $10{\mu}m$ of the outermost layer of the enamel. 5. The higher Ca/P ratios were observed in $10{\mu}m$ depth of lased and fluorided enamel when compared to the sound and carious enamel. The fluoride content decreased rapidly with distance from enamel surface, in the group F, fluoride concentration was significantly higher than that in the group C, L, FL, LF and control group according to increasing enamel depth (P<0.05).

  • PDF

Characteristics of Tissue Dose of High Dose Rate Ir-192 Source Substitution for Co-60 Brachytherapy Source (코발트-60 선원 대체용 고선량률 Ir-192 선원의 조직선량특성)

  • 최태진;이호준;김옥배
    • Progress in Medical Physics
    • /
    • v.9 no.4
    • /
    • pp.259-266
    • /
    • 1998
  • To achieve the 2D dose distribution around the designed high dose rate Ir-192 source substitution for Co-60 brachytherapy source, we determined the exposure rate constant and tissue attenuation factors as a large depth as a 20 cm from source center. The exposure rate constant is used for apparent activity in designed source with self-absorption and encapsulation steel wall. The tissue dose delivered from the 4401 segments of 2.5 mm in a diameter and 2.5 mm height of disk-type source layer. In the experiments, the tissue attenuation factors include the tissue attenuation and multiple scattering in a medium surrounding the source. The fitted the polynomial regression with 4th order for the tissue attenuation factors are very closed to the experimental measurement data within ${\pm}$1% discrepancy. The Meisberger's constant showed the large uncertainty in large distance from source. The exposure rate constant 4.69 Rcm$^2$/mCi-hr was currently used for determination of apparent activity of source and air kerma strength was obtained 0.973 for tissue absorbed dose from the energy spectrum of Ir-192 source. In our experiments with designed high dose rate brachytherapy source, the apparent activity of Ir-192 source was delivered from the 54.6 % of actual physical source activity through the self-absorption and encapsulation wall attenuations. This paper provides the 2-dimensional dose tabulation from unit apparent activity in a water medium for dose planning includes the multiple scattering, source anisotropy effect and geometric factors.

  • PDF

Molecular analysis of alternative transcripts of equine AXL receptor tyrosine kinase gene

  • Park, Jeong-Woong;Song, Ki-Duk;Kim, Nam Young;Choi, Jae-Young;Hong, Seul A;Oh, Jin Hyeog;Kim, Si Won;Lee, Jeong Hyo;Park, Tae Sub;Kim, Jin-Kyoo;Kim, Jong Geun;Cho, Byung-Wook
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.30 no.10
    • /
    • pp.1471-1477
    • /
    • 2017
  • Objective: Since athletic performance is a most importance trait in horses, most research focused on physiological and physical studies of horse athletic abilities. In contrast, the molecular analysis as well as the regulatory pathway studies remain insufficient for evaluation and prediction of horse athletic abilities. In our previous study, we identified AXL receptor tyrosine kinase (AXL) gene which was expressed as alternative spliced isoforms in skeletal muscle during exercise. In the present study, we validated two AXL alternative splicing transcripts (named as AXLa for long form and AXLb for short form) in equine skeletal muscle to gain insight(s) into the role of each alternative transcript during exercise. Methods: We validated two isoforms of AXL transcripts in horse tissues by reverse transcriptase polymerase chain reaction (RT-PCR), and then cloned the transcripts to confirm the alternative locus and its sequences. Additionally, we examined the expression patterns of AXLa and AXLb transcripts in horse tissues by quantitative RT-PCR (qRT-PCR). Results: Both of AXLa and AXLb transcripts were expressed in horse skeletal muscle and the expression levels were significantly increased after exercise. The sequencing analysis showed that there was an alternative splicing event at exon 11 between AXLa and AXLb transcripts. 3-dimentional (3D) prediction of the alternative protein structures revealed that the structural distance of the connective region between fibronectin type 3 (FN3) and immunoglobin (Ig) domain was different between two alternative isoforms. Conclusion: It is assumed that the expression patterns of AXLa and AXLb transcripts would be involved in regulation of exercise-induced stress in horse muscle possibly through an $NF-{\kappa}B$ signaling pathway. Further study is necessary to uncover biological function(s) and significance of the alternative splicing isoforms in race horse skeletal muscle.