• Title/Summary/Keyword: Physical cleaning

Search Result 188, Processing Time 0.028 seconds

Effect of Occupants' Behaviour of Environmental Control on Improvement of Air Environment in Winter's High School Classroom (겨울철 고등학교 교실에서 재실자의 환경조절행동이 공기환경 개선에 미치는 영향)

  • Kwak, Ro-Yeul
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.36 no.4
    • /
    • pp.163-172
    • /
    • 2020
  • In this study, the effect of window opening, which is a control mechanism for air control in winter high school classrooms, on the change in air and indoor environment of the classroom was analyzed and physical conditions of indoor and air environment were observed during the classroom course, and satisfaction of the students and teachers was assessed with questionnaires. And the changes in air environment were assessed by the performance of the duster cleaning work in the classroom. It was found that 84.6% of the students surveyed said the air was stuffy. And among the alternatives, opening windows all times during class was most effective in reducing CO2 concentration and PM concentration was measured within classroom's standard. In addition, the concentration change rate of duster cleaning work was reduced by 74.4% and 65.4% of PM10 compared to broom cleaning work.

Evaluation of Cleaning ability and Environmental Evaluation of Commercial Aqueous/Semi-aqueous Cleaning Agents (시판 수계/준수계 세정제의 세정성 및 환경성 평가 연구)

  • Cha, A.J.;Park, J.N.;Kim, H.S.;Bae, J.H.
    • Clean Technology
    • /
    • v.10 no.2
    • /
    • pp.73-87
    • /
    • 2004
  • In most of industrial fields, cleaning is employed for removing soils on their products or parts. Halogenated cleaning agents such as CFC-113, 1,1,1-TCE(1,1,1-trichloroethane), MC(methylene chloride) and TCE (trichloroethylene) have been used as cleaning ones in most of companies in the world since their excellent performance of cleaning ability and good material compatibility. However, CFC-113 and 1,1,1-TCE which are ozone destruction substances are not used any more in the advanced countries because of the which are ozone destruction substances are not used any more in the advanced countries because of the Montreal protocol. MC and TCE are now used restrictively at small part of industrial fields in most of countries since they are known to be hazardous or carcinogenic materials. Thus, it is indispensible that the alternative cleaning agents which are environmental-friendly and safe, and show good cleaning ability should be developed or utilized for replacement of the halogenated cleaning agents. Aqueous/semi-aqueous cleaning agents are evaluated to be promising alternative ones among various alternatives in environmental and economical view point. In this study, commercially available 12 aqueous and 6 semi-aqueous cleaning agents were selected and their physical properties, cleaning abilities, rinsing abilities and recycling of contaminated rinse water were measured and analyzed. Aqueous cleaning agents with higher wetting index showed better cleaning ability compared with those with lower wetting index. However wetting index did not have any correlation with cleaning ability in semi-aqueous cleaning agents. It was observed that soil concentration in aqueous and semi-aqueous cleaning agents should be maintained below the certain concentrations which depend on types of clearing agents. More than 70% soils in contaminated rinse water by some of aqueous and semi-aqueous clearing agents could be separated by simple settling method. This means that some cleaning agents with high oil-water separation efficiency will be effiective for recycling oil-contaminated rinse water. It was found that contaminated rinse water with aqueous agents was purified easiy by ultrafiltration method with PAN membrane of 30 kDa.

  • PDF

Harvesting of microalgae via submerged membranes: flux, fouling and its reversibility

  • Elcik, Harun;Cakmakci, Mehmet
    • Membrane and Water Treatment
    • /
    • v.8 no.5
    • /
    • pp.499-515
    • /
    • 2017
  • The purpose of this study was to investigate membrane fouling caused by microalgal cells in submerged membrane systems consisting of polymeric and ceramic microfiltration membranes. In this study, one polymeric (flat-sheet, pore size: $0.2{\mu}m$) and two ceramic (flat-sheet, pore size: $0.2{\mu}m$ and cylindrical, pore size: $1{\mu}m$) membranes were used. Physical cleaning was performed with water and air to determine the potential for reversible and irreversible membrane fouling. The study results showed that substantial irreversible membrane fouling (after four filtration cycles, irreversible fouling degree 27% (cleaning with water) and 38% (cleaning with air)) occurs in the polymeric membrane. In cleaning studies performed using water and air on ceramic membranes, it was observed that compressed air was more effective (recovery rate: 87-91%) for membrane cleaning. The harvesting performance of the membranes was examined through critical flux experiments. The critical flux values for polymeric membrane with a pore size of $0.20{\mu}m$ and ceramic membranes with a pore size of $0.20{\mu}m$ and $1{\mu}m$ were ${\leq}95L/m^2hour$, ${\leq}70L/m^2hour$ and ${\leq}55L/m^2hour$, respectively. It was determined that critical flux varies depending on the membrane material and the pore size. To obtain more information on membrane fouling caused by microalgal cells, the characterization of the fouled polymeric membrane was performed. This study concluded that ceramic membranes with a pore size of $0.2-1{\mu}m$ in the submerged membrane system could be efficiently used for microalgae harvesting by cleaning the membrane with compressed air at regular intervals.

Study on removal method of Brownish black and White crust on Mural in Koguryo Tomb (고구려 고분벽화 오염물질 제거에 관한 연구)

  • Han, Kyeong-Soon;Lim, Kwon-Woong
    • Journal of Conservation Science
    • /
    • v.22
    • /
    • pp.99-108
    • /
    • 2008
  • This research aimed to provide a scientific methodology for removing white and black/brown coloured stains on the wall paintings of tombs of Jinpari No 1 and No 4. in the Democratic People's Republic of Korea. For the analysis of chemical composition of stains of the samples from the wall paintings, a microscope and SEM/EDX were used. The analysis confirmed that the fomula of white coloured stains should be $CaSO_4$ or $CaCO_3$ and the black/brown coloured stains should be $CaSO_4$ or $CaCO_3$ with soil deposition. Because of the difficulties of testing several cleaning solutions on sample patches of large area of the painting, the author considered a risk-free cleaning solution as being the most appropriate one, with Ammonium bicarbonate and Anion exchange resin showing satisfactory cleaning effect without visible side effects. For the removal of dense layer of stains, the research suggested that physical cleaning should be followed by applying a cleaning solution.

  • PDF

Effects of Isothermal Stabilization Process and Ultrasonic Cleaning on the Characteristics of Rayon Fabrics (레이온직물의 특성에 미치는 등온 안정화공정 및 초음파세척의 영향)

  • Cho, Chaewook;Cho, Donghwan;Park, Jong Kyoo;Lee, Jae Yeol
    • Journal of Adhesion and Interface
    • /
    • v.14 no.1
    • /
    • pp.21-27
    • /
    • 2013
  • Cellulose-based rayon fibers or fabrics can be thermally decomposed very fast within a narrow temperature window during stabilization process. Therefore the stabilization stage is critically important for producing rayon-based carbon fibers. Consequently, in the present study the effects of isothermal stabilization and ultrasonic cleaning on the weight loss, chemical composition, microstructure, and fabric texture of cellulose-based rayon fabrics were explored. The temperature of the isothermal stabilization process performed in the range of $200{\sim}240^{\circ}C$ influenced the processing time, carbon and oxygen contents, cellulose structural change, and fabric texture. The ultrasonic cleaning, which was conducted prior to the stabilization process, played a role in shortening the stabilization time, increasing the carbon contents, decreasing the oxygen contents, and changing the XRD pattern. Also, it was considered that the ultrasonic cleaning contributed to retarding the weight loss, to reducing the thermal shrinkage, and further to reducing the fast physical change of rayon fabrics.

Effects of Ultrasonic Cleaning and Chemical Pre-treatment on the Characteristics of Fast-stabilized Rayon Fabrics (빠르게 안정화된 레이온직물의 특성에 미치는 초음파세척 및 화학전처리 영향)

  • Cho, Chae Wook;Cho, Donghwan
    • Journal of Adhesion and Interface
    • /
    • v.14 no.3
    • /
    • pp.146-159
    • /
    • 2013
  • In the present study, stabilized rayon fabrics were prepared from fast isothermal stabilization processes, which were carried out within four minutes at $350^{\circ}C$. The effects of ultrasonic cleaning and chemical pre-treatment on the chemical composition, physical characteristics, X-ray diffraction pattern, thermal stability and shape of the stabilized rayon fabrics were investigated extensively. In order to reduce the weight loss and thermal shrinkage of rayon fabrics occurring during the stabilization process, ultrasonic cleaning was first conducted and then chemical pre-treatments using $NH_4Cl$, $Na_3PO_4$, $H_3PO_4$, and $ZnCl_2$ were performed, respectively. The results indicated that both ultrasonic cleaning and chemical pre-treatment influenced the weight loss, thermal shrinkage, microstructure, carbon content, thermal stability and fabric shape of stabilized rayon fabrics. Also the results depended on the fast-stabilization time and the type of chemical pre-treatment agents used.

CFD simulation of cleaning nanometer-sized particulate contaminants using high-speed injection of micron droplets (초고속 미세 액적 충돌을 이용한 나노미터 크기 입자상 오염물질의 세정에 대한 CFD 시뮬레이션)

  • Jinhyo, Park;Jeonggeon, Kim;Seungwook, Lee;Donggeun, Lee
    • Particle and aerosol research
    • /
    • v.18 no.4
    • /
    • pp.129-136
    • /
    • 2022
  • The line width of circuits in semiconductor devices continues to decrease down to a few nanometers. Since nanoparticles attached to the patterned wafer surface may cause malfunction of the devices, it is crucial to remove the contaminant nanoparticles. Physical cleaning that utilizes momentum of liquid for detaching solid nanoparticles has recently been tested in place of the conventional chemical method. Dropwise impaction has been employed to increase the removal efficiency with expectation of more efficient momentum exchange. To date, most of relevant studies have been focused on drop spreading behavior on a horizontal surface in terms of maximum spreading diameters and average spreading velocity of drop. More important is the local liquid velocity at the position of nanoparticle, very near the surface, rather than the vertical average value. In addition, there are very scarce existing studies dealing with microdroplet impaction that may be desirable for minimizing pattern demage of the wafer. In this study, we investigated the local velocity distribution in spreading liquid film under various impaction conditions through the CFD simulation. Combining the numerical results with the particle removal model, we estimated an effective cleaning diameter (ECD), which is a measure of the particle removal capacity of a single drop, and presented the predicted ECD data as a function of droplet's velocity and diameter particularly when the droplets are microns in diameter.

Stability Evaluation of Cleaning Agent for Ceramics (토기 및 도자기 유물에 사용되는 보존처리용 세척제의 안정성 평가)

  • Park, Daw-Woo;Kang, Hyun-Mi;Nam, Byeong-Jik;Jang, Sung-Yoon
    • Journal of Conservation Science
    • /
    • v.25 no.4
    • /
    • pp.451-464
    • /
    • 2009
  • To do conservation for ceramics, sometimes it needs to clean the ceramics chemically to remove stains on the ceramics, which should be performed with caution. This study will provide quantitative data about the extraction characteristics of major elements from ceramics through the soaking test to evaluate the stability of ceramic cleaning agents. As soft textured pottery(fired at $700^{\circ}C$) had high absorption, it showed higher extraction characteristics in short soaking time. Especially the strong acid among chemical cleaning agents caused the expoliation and the color change on the surface of soft textured pottery. But these color change had no effect on the physical characteristics of soft textured pottery. The hard textured pottery(fired at $1,000^{\circ}C$) is relatively stable in the cleaning agent because it is ascertained the extraction of that was not enough and also it had little chromatic and physical change by strong acid. Porcelains(Celadon, Whiteware and Puncheong ware) was safer than the soft textured pottery due to their low extraction. But it should take precautions to clean the porcelains with lots of cracklewares such like Puncheong ware chemically in connection with the extraction characteristics and their cracklewares.

  • PDF

A Study on Ion Extraction Characteristics of Ceramics by Cleaning Agents (보존처리용 세척제에 대한 토기의 이온용출 특성연구)

  • Park, Dae-Woo;Kang, Hyun-Mi;Nam, Byeong-Jik;Jang, Sung-Yoon;Ham, Chul-Hee
    • 보존과학연구
    • /
    • s.31
    • /
    • pp.43-57
    • /
    • 2010
  • This study intends to provide quantitative data about the extraction characteristics of major elements of earthenware by executing soaking test of cleaning agents. It aims at providing basic data for the stability assessment when applying the cleaning agents for conserving earthenware. The data will be extracted from the analysis of co-relationship between the physical characteristics and the ion extraction characteristics. XRD analysis displayed that AT-1, AT-2 and AT-3 which did not generate mullite were fired at lower than 1,000 whereas AT-3 and AT-5 that included mullite were higher than 1,000. The degree of absorption was AT-4 > AT-2 > AT-1 > AT-3 > AT-5 in order and the correlation between the degree of absorption and firing temperature of earthenware displayed a positive correlation. Extraction amount of oxalic acid which was used for the removing iron oxide was AT-1 > AT-2 AT-4 > AT-3 > AT-5 in order. and the ion extraction data displayed that there is a positive correlation with absorption level. However AT-1 and AT-2 which were fired at lower temperature showed that there was no correlation between the ion extraction characteristics and absorption level. Ion extraction of citric acid produced little amount compared with the one of oxalic acid, yet it caused less damage to earthenware than oxalic acid when it applied. The result of ion extraction level in the absorption test displayed that Fe had higher level than in Si, Al from the test for both oxalic acid and citric acid. Based on the regression analysis of the data from the previous studies, the physical characteristics of the earthenware and ion extraction level, further studies will be conducted on the predicting technique on the extraction characteristics of major elements of earthenware samples for the conservation in future.

  • PDF