• Title/Summary/Keyword: Physical Mode

Search Result 675, Processing Time 0.024 seconds

Fabrication and characterization of SILO isolation structure (SILO 구조의 제작 방법과 소자 분리 특성)

  • Choi, Soo-Han;Jang, Tae-Kyong;Kim, Byeong-Yeol
    • Proceedings of the KIEE Conference
    • /
    • 1988.07a
    • /
    • pp.328-331
    • /
    • 1988
  • Sealed Interface Local Oxidation (SILO) technology has been investigated using a nitride/oxide/nitride three-layered sandwich structure. P-type silicon substrate was either nitrided by rapid thermal processing, or silicon nitride was deposited by LPCVD method. A three-layered sandwich structure was patterned either by reactive ion etch (RIE) mode or by plasma mode. Sacrificial oxidation conditions were also varied. Physical characterization such as cross-section analysis of field oxide, and electrical characterization such as gate oxide integrity, junction leakage and transistor behavior were carried out. It was found that bird's beak was nearly zero or below 0.1um, and the junction leakages in plasma mode were low compared to devices of the same geometry patterned in RIE mode, and gate oxide integrity and transistor behavior were comparable. Conclusively, SILO process is compatible with conventional local oxidation process.

  • PDF

Independent Clinic Open of Physical Therapist (물리치료사의 자립개원)

  • Song Ju-Young;Kim Hyung-Nam;Cho Gui-Soon
    • The Journal of Korean Physical Therapy
    • /
    • v.8 no.1
    • /
    • pp.81-89
    • /
    • 1996
  • This study is to make legal suggestions concerning the legal status of the physical therapists and the their clinics io Korea. This study compares the legal status of the physical therapists with that of the optical and dental technicians, and reviews the current system of the American physical therapeutic clinic. 1. Under the supervision of the doctor or dentist' in Article 1 of Law concerning the Medical Technician should be deleted or changed into 'by the request of the doctor or dentist'. A new independent law should be mode only fer the physical therapist from the general law that stipulates the legal status of other similar medical technicians. 3. The legal status of the physical therapeutic clinic should be stipulated in the regulations for the application of the law as that of the dental technician does. The modification of the medical services, the medical expences, waiting time, the easy access to the clinic of farmers, fishermen, urban laborers, and handicapped people, and the development of the area of the physical therapy.

  • PDF

A Hybrid IPO-MoM Technique for Wave Scattering Analysis of Jet Engine (제트 엔진 산란 해석을 위한 하이브리드 IPO-MoM 기법)

  • Lim, Ho;Choi, Seung-Ho;Myung, Noh-Hoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.8
    • /
    • pp.791-796
    • /
    • 2009
  • A hybrid iterative physical optics-method of moments(IPO-MoM) technique is presented for the analysis of jet engine structures which are both electrically large and complex. In this technique, the IPO method is used to analyze smooth inlet region and the MoM method is used to analyze electrically complex region inclusive of blades and hub. It is efficient and accurate by virtue of combining the respective merits of both methods. Numerical results are presented and validated through comparison with Mode-FDTD and measured results.

Identification of nonlinear elastic structures using empirical mode decomposition and nonlinear normal modes

  • Poon, C.W.;Chang, C.C.
    • Smart Structures and Systems
    • /
    • v.3 no.4
    • /
    • pp.423-437
    • /
    • 2007
  • The empirical mode decomposition (EMD) method is well-known for its ability to decompose a multi-component signal into a set of intrinsic mode functions (IMFs). The method uses a sifting process in which local extrema of a signal are identified and followed by a spline fitting approximation for decomposition. This method provides an effective and robust approach for decomposing nonlinear and non-stationary signals. On the other hand, the IMF components do not automatically guarantee a well-defined physical meaning hence it is necessary to validate the IMF components carefully prior to any further processing and interpretation. In this paper, an attempt to use the EMD method to identify properties of nonlinear elastic multi-degree-of-freedom structures is explored. It is first shown that the IMF components of the displacement and velocity responses of a nonlinear elastic structure are numerically close to the nonlinear normal mode (NNM) responses obtained from two-dimensional invariant manifolds. The IMF components can then be used in the context of the NNM method to estimate the properties of the nonlinear elastic structure. A two-degree-of-freedom shear-beam building model is used as an example to illustrate the proposed technique. Numerical results show that combining the EMD and the NNM method provides a possible means for obtaining nonlinear properties in a structure.

Electromagnetic Coupling to Nonuniform Transmission Lines, II:Correction to the Cylindrical TEM Mode Solution (비균일 전송선의 전자기적 결합, II:원통형 TEM 모드 해의 수정)

  • 홍성용;김세윤;라정웅
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.30A no.2
    • /
    • pp.10-15
    • /
    • 1993
  • The cylindrical TEM mode solution for electromagnetic coupling to an angled two-wire transmission line is corrected by imposing some physical constraints additionally. The validity of the correction process is assured by showing that the corrected solution approaches the numerical result for the equivalent model of cascaded piecewise uniform sections.

  • PDF

Vibration Analysis for a Huge Marine Engine using a Substructure Synthesis Method (부분구조합성법을 이용한 대형선박엔진의 진동분석)

  • Lee, Jae-Whoan;Jung, Jong-Ha;Kim, Chae-Sil;Park, Hyung-Ho
    • Proceedings of the KSME Conference
    • /
    • 2001.06b
    • /
    • pp.651-657
    • /
    • 2001
  • This article explains the theory of multiple mode/physical coordinate synthesis method in order to analyze the dynamic characteristics for an huge marine engine. The theory leads to make a simulation code. The natural frequencies obtained from the simulation code is compared to those from a commercial analysis software, ANSYS. The simulation code is well reviewed.

  • PDF

Image Quality and Dose Assessment According to Examination Mode during Head CT Examination (두부 CT 검사 시 검사 모드에 따른 화질 및 선량평가)

  • Gang, Heon-Hyo;Choi, Woo-Jeon;Kim, Dong-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.4
    • /
    • pp.437-444
    • /
    • 2021
  • To evaluate the usefulness of Volume Axial Mode by comparing analyzing the exposure dose of the patients and the quality of each images from CT images obtained from high pitch mode using the local phantom or volume axial mode to determine the usefulness of he volume axial mode in diagnosing the head and cervical disease in adults. High Pitch Mode, Helical Mode, and Volume axial Mode as adult phantom were tested according to 70 kVp, 80 kVp, and 100 kVp tube voltages during an adult frontal CT scans. The equipment used was GE's Revolution (GE Healthcare, Wisconsin USA) model and iMED X-ray Phantom. The exposure dose of phantom was compared using the images obtained from each protocol, and the image quality was compared by calculating SNR and CNR by setting ROI on each image. When examined using Volume Axial Mode, the exposure dose of phantom was measured 17.12% lower than Helical Mode, 5.35% lower than High Pitch Mode, and both SNR and CNR were improved. Volume Axial Mode is a useful test that reduces investigation time without table movement using high speed rotary scanner, and in which exposure dose is reduced and image quality is improved by acquiring images in a short time of 0.28 seconds of phantom than using High Pitch Mode and Helical Mode. In addition, the fast testing time of Volume Axial Mode can be seen as the biggest advantage CT scans of emergency patients or patients with physical discomfort.

Effects of Pelvic Floor Muscle Function on Mode of Delivery (분만방법 유형이 골반바닥근육 기능에 미치는 영향)

  • Kwon, Yu-Jeong;Lee, Hyun-Ok
    • PNF and Movement
    • /
    • v.15 no.3
    • /
    • pp.373-380
    • /
    • 2017
  • Purpose: The purpose of this study was to investigate of the effects of the mode of delivery on pelvic floor muscle function by examining bladder base movement and urinary incontinence. Methods: This study was conducted on 100 females who had delivered in the previous 3-8 months. There were 2 groups: 56 vaginal deliveries and 44 cesarean section deliveries. Prior to the study, a survey was conducted on the subjects' general status, delivery mode, urinary incontinence, and physical activity. The groups could not be blinded due to scar tissue from the operations. The function of the pelvic floor muscle was observed with the bladder base movement using transabdominal ultrasound during pelvic floor contraction. To objectify and measure the subjective symptoms of subjects suffering from urinary incontinence, an incontinence quality of life (I-QoL) test was administered. Statistical analysis of the data was performed using SPSS version 20.0. An independent t-test was used to assess the statistical significance of pelvic floor muscle function between the 2 groups after delivery. Results: The movement of the bladder base in the pelvic floor muscle function was decreased in the vaginal delivery group, but the difference was not significant. Urinary incontinence was significantly increased in the vaginal delivery group. Conclusion: The function of the pelvic floor muscles was better in the cesarean section group and the incidence of urinary incontinence was relatively low in this group. Therefore, vaginal delivery requires more efforts to restore the function of the pelvic floor muscles than cesarean delivery.

Evaluation of mental and physical load using inverse regression on sinus arrhythmia scores

  • Lee, Dhong-H.;Park, Kyung-S.
    • Journal of the Ergonomics Society of Korea
    • /
    • v.6 no.1
    • /
    • pp.3-8
    • /
    • 1987
  • This paper develops a statistical mode which estimates mental and physical loads of light work from sinus arrhythmia (SA) scores. During experiments, various levels of mental and physical loads (respectively scored by information processing and finger tapping rates) were imposed on subjects and SA scores were measured from the subjects. Two methods were used in developing workload estimation model. One is an algebraic inverse function of a multivariate regression equation, where mental and physical loads are independent variables and SA scores are dependent variables. The other is a statistical multivariate inverse regression. Of the two methods, inverse function resulted in larger mean squqre error in predicting mental and physical loads. Hence, inverse regression model is recommended for precise workload estimation.

  • PDF