• 제목/요약/키워드: Photovoltaic (PV) power system

검색결과 770건 처리시간 0.027초

태양광발전시스템과 계통간의 전력 전송 효율 개선을 위한 최대효율점 추적 제어 알고리즘 (Maximum Efficiency Point Tracking Control Algorithm for Improving Electric Power Transmission Efficiency between Photovoltaic Power Generating system and the Grid)

  • 권철순;김광수;도태용;박성준;강필순
    • 전기학회논문지
    • /
    • 제62권3호
    • /
    • pp.342-348
    • /
    • 2013
  • It proposes an efficient control algorithm to increase electric power transmission efficiency between photovoltaic power generating system and the grid. The main controller finds a maximum efficiency condition by considering the quantity of power generated from PV arrays, the number of inverters, and efficiency of PV inverter. According to the condition, a relay board arranges a point of contract of PV arrays. By the disposition of PV arrays, it assigns the optimized power on each PV inverter. Operational principle of the proposed maximum efficiency point tracking algorithm is given in detail. To verify the validity of the proposed approach, computer-aided simulation and experiment carried out.

3kW 태양광발전시스템의 효율분석에 관한 연구 (A study of on the Efficiency Analysis for 3kW Utility interactive PV System)

  • 박정민;임홍우;최연옥;이성길;조금배;백형래
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.61-63
    • /
    • 2005
  • Utility interactive photovoltaic systems is one of the most premising applications of photovoltaic systems. These systems are employed in applications where utility service is already available. In this case, there is no need for battery storage because utility power may be used to supplement photovoltaic systems when the load exceeds available PV generation. The load receives electricity from both the photovoltaic array and the utility inter-tied. In this paper, Principle and operating characteristic of Utility Interconnected Photovoltaic System is presented. For the purpose of optimal utility Inter-tied photovoltaic system design and installation. It is that demonstrate throughout the installed 3 PV system respectively, 3kW utility interconnected residential system.

  • PDF

PV모듈의 음영 상태 및 바이패스 다이오드 단락 고장 특성 분석 (The Characteristics of PV module under the Partial Shading Condition and with a Failure of Bypass Diode with Short)

  • 고석환;주영철;소정훈;황혜미;정영석;강기환
    • 한국태양에너지학회 논문집
    • /
    • 제36권4호
    • /
    • pp.41-47
    • /
    • 2016
  • A bypass diode is connected in parallel to solar cells with opposite polarity. The advantage of using the bypass diode is circumvented a destructive efforts of hot-spot heating in the photovoltaic(PV) module. In addition, it is possible to reduce a energy loss under the partial shading on the PV module. This paper presents a characteristic of photovoltaic module under partial shading condition and with defective bypass diode by using the experimental data. The results of field testing for each photovoltaic modules, when photovoltaic system which is connected power grid is operating, the inner junction-box temperature of shading photovoltaic module is high $5^{\circ}C$ because of difference of flowing current through into bypass diode. And incase of not operating photovoltaic system, the inner junction-box temperature of module with defective bypass diode is greatly higher than partial shading PV module.

반사판을 이용한 태양광발전시스템 실증연구 (Demonstration Research of Photovoltaic System with Solar Reflectors)

  • 김용식;강기환;심상용;이후락;이진섭;홍진기
    • 한국태양에너지학회 논문집
    • /
    • 제29권1호
    • /
    • pp.64-69
    • /
    • 2009
  • This paper aims at enhancing the electric production efficiency of photovoltaic(PV) system. The electrical power of PV system is proportional to light intensity on a PV module surface. In this paper, we apply two types of systems to enhance power generation efficiency. First, of all, concentring sunlight using specular surface and one-axis tracking system which traces the sun with vertical direction are applied in this project. From this, we analyze the fixed type method and power generation efficiency.

서울시 한강교량의 태양광발전시스템 적용 시 경관조명 에너지 절약에 관한 경제성 분석 및 고찰 (An Economic Analysis and Consideration on the Application of Photovoltaic System for Bridge Nightscape Energy Savings at Han River in Seoul)

  • 박윤민;홍성관;최안섭
    • 조명전기설비학회논문지
    • /
    • 제25권1호
    • /
    • pp.42-49
    • /
    • 2011
  • PV(Photovoltaic) system is environmentally friendly power system using solar energy in renewable energy. PV system compared to other renewable energy power generation systems is relatively easy to install, so the dissemination is increasing worldwide. Especially, BIPV(Building Integrated Photovoltaic) is a system that PV modules are installed on the building and use renewable energy. But this system is difficult to apply due to the shadow of adjacent buildings and limited installation. In this study, payback period is calculated by Retscreen 2010, that is an economic assessment software of renewable energy, on applied to the bridge of PV system. As results, this study aims at actively considering the application.

학교 교실의 태양광발전 환기시스템 적용성 연구 (A Study on Application of a Heat Recovery Ventilator using Photovoltaic System in School)

  • 장용성;서승직;홍성희;유권종;박효순
    • 한국태양에너지학회 논문집
    • /
    • 제25권1호
    • /
    • pp.27-34
    • /
    • 2005
  • This study aims to evaluate application of a heat recovery ventilator(HRV) using photovoltaic(PV) system. To this end, we analyzed performance of a PV system, which it was evaluated by monthly power wattage and conversion efficiency according to design capacity of a HRV. The results of this study can be summarized as follows. (1) A conversion efficiency of the PCS was evaluated about 86% in rated power. (2) A maximum, minimum and average output power were respectively analyzed 49.2W, 47.3W, and 48.8W. (3) Total power wattage of 200W PV system was 211kW and it was 316kW in case of 300W PV system. (4) Insufficient electrical power of a duct and window type ventilation system was respectively calculated 133.5kW and 147.7kW.

A Study of Islanding Detection of Grid-connected Three-phase Photovoltaic Power Conditioning System

  • Jung Y.S.;Yu G.J.;Choi J.Y.;Choi J.H.
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(2)
    • /
    • pp.761-764
    • /
    • 2003
  • Islanding phenomenon of a grid-connected photovoltaic (PV) power conditioning system (PCS) is said to occur if the PCS continues to power a section of the utility system after that section has been disconnected from the utility source. Since islanding creates hazards for personnel and equipment, PCSs are required to detect and prevent Et. In this paper, several islanding detection methods (IDMs) and reactive power variation method are described. Islanding test results for 9kW PCS are presented for verification.

  • PDF

태양광 발전시스템에서 모듈 설치 각도와 어레이 간격의 비교 연구 (Comparison Researches for Installation of the Module Angles and Array Spacing on Photovoltaic Power System)

  • 최동진
    • 조명전기설비학회논문지
    • /
    • 제23권1호
    • /
    • pp.162-168
    • /
    • 2009
  • 본 논문에서는 태양전지를 가지고 일정량의 태양광으로부터 최대 유효전력을 얻기 위해 고정식 태양광 발전시스템과 태양 위치추적기를 부착한 태양광 발전시스템에서 PV모듈의 각도 변화 및 어레이 간격에 따른 최적의 발전효율에 대한 연구 및 실험을 하였다. 먼저, PV 모듈의 다양한 각도를 가지고 실험한 결과 PV 모듈 경사각 30[$^{\circ}$]에서 측정한 결과 값이 경사각 20[$^{\circ}$] 및 40[$^{\circ}$]일 때보다 발전 효율이 $12{\sim}17$[%] 상승되었다. 그러므로 본 논문의 연구 결과에서는 태양광 발전시스템의 실용화 측면에서 PV 모듈의 경사각 30[$^{\circ}$] 설치를 하여 발전을 하는 것이 가장 좋은 변환 효율을 얻을 수 있었다. 하지만 태양전지를 지붕 및 옥상에 설치를 할 경우, 면적 활용이 좁고 겨울에 눈이 쌓이게 될 경우에는 경사각에 의해 빠르게 쓸려 내려갈 수 있도록 경사각을 35[$^{\circ}$]로 선정하는 것이 타당하다.

50kW급 계통연계형 태양광발전시스템의 시뮬레이터 구현 (Implementation of the 50kW Utility Interconnected Photovoltaic System Simulator)

  • 정병호;박정민;조금배;백형래;정수복
    • 한국태양에너지학회 논문집
    • /
    • 제25권4호
    • /
    • pp.21-27
    • /
    • 2005
  • This paper summarizes the results of these efforts by offering a photovoltaic system structure in 50kW middle scale applications installed in Cho-sun University dormitory roof. The combination of photovoltaic system components are interconnected and system monitoring system will be summarized for the purpose of the increasing safety in this article. This paper describes configuration of utility interactive photovoltaic system which generated electric power supplies to dormitory. In order to installing the middle or large scale photovoltaic system, It must investigated the optimal design of system, compute quantity of power generation, economic rate of return and so on. In this paper represent 50kW utility photovoltaic system examination and developed simulation results. The performance of photovoltaic system has been evaluated and analyzed with simulation. The results obtained in this research will be much useful to prior investigation for installing utility interactive photovoltaic system.

계통연계형 태양광발전시스템의 동특성 모델링 및 모의해석 (Modeling and Simulation Analysis of Grid-Connected Photovoltaic Generation System in terms of Dynamic behavior)

  • 김응상;김슬기
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2005년도 춘계학술대회
    • /
    • pp.127-131
    • /
    • 2005
  • The paper addresses modeling and analysis of a grid-connected photovoltaic generation system (PV system). PSCAD/EMIDC. an industry standard simulation tool for studying the transient behavior of electric power system and apparatus. is used to conduct all aspects of model implementation and to carry out extensive simulation study. An equivalent circuit model of a solar cell has been used for modeling solar array. A PWM voltage source inverter (VSI) and its current control scheme have been implemented. A maximum power point tracking (MPPT) technique is employed for drawing the maximum available energy from the PV array. Comprehensive simulation results are presented to examine PV array behaviors and PV system control performance in response to irradiation changes. In addition, dynamic responses of PV array and system to network fault conditions are simulated and analysed

  • PDF