• 제목/요약/키워드: Photovoltaic(PV) Cell

검색결과 318건 처리시간 0.038초

공기 중의 미세먼지에 의한 태양전지의 오염에 관한 연구 (A Study on the Contamination of Photovoltaic Cells by Fine Dust in the Air)

  • 한진목;최수광;김세웅;정영관
    • 한국수소및신에너지학회논문집
    • /
    • 제29권3호
    • /
    • pp.292-298
    • /
    • 2018
  • The contamination of photovoltaic (PV) cells reduces the incidence of sunlight and reduces the power generation output of PV cells. The main factor influencing the contamination of PV cells installed outdoors is the fine dust in the air, but the influence of temperature, humidity, rain and wind can be considered. In this paper, experiments on the contamination of PV cells according to the fine dust density, the temperature and humidity of air were investigated. As results of this study, the contamination area of PV cells increases with contamination time and cumulative fine dust density in the air. The contamination of PV cells increases when the temperature is low and the humidity is high. Also, as the contamination of PV cells is affected to the wind, the deviation of contamination area is happened.

PV모듈의 발전성능시험을 위한 Solar Simulator의 측정불확도 요인 분석 (Analysis of Solar Simulator's Uncertainty Factor for Maximum Output Power Test of Photovoltaic Module)

  • 강기환;김경수;박지홍;유권종;안형근;한득영
    • 한국태양에너지학회 논문집
    • /
    • 제27권1호
    • /
    • pp.39-45
    • /
    • 2007
  • In this paper, we analyzed the elements of measurement uncertainty on electrical performance test which are the most important things in photovoltaic module performance test. Repeating the performance test by 6 men, the measurement uncertainty could be calculated. In this experiment, Solar Simulator (A-Class pulse type) used for domestic certificate test of PV module is Pasan IIIb (Balval, Switzerland). The possible elements of the measurement uncertain that could effect electrical performance test of PV module are reference cell, spectrum correction, error from measurement repetition, test condition, stability and uniformity of artificial solar simulator. To find the measurement uncertainty, 6 men repeated the test by 10 times. And the results were that numerical average value was 124.44W and measurement uncertainty was $124.44W{\pm}0.36W$ with 95% confidence level for 125W PV module(KD-5125).

PV모듈의 I-V특성 시험을 위한 Solar Simulator의 측정불확도 요인 분석 (Analysis of Solar Simulator's Uncertainty Factor for Photovoltaic Module's I-V curve test)

  • 강기환;박지홍;김경수;유권종;안형근;한득영
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 하계학술대회 논문집 Vol.7
    • /
    • pp.5-7
    • /
    • 2006
  • In this paper, we analyzed the elements of measurement uncertainty on electrical performance test which are the most important things in photovoltaic module performance test. Repeating the performance test by 6 men, the measurement uncertainty could be calculated. In this experiment, Solar Simulator (A-Class pulse type) used for domestic certificate test of PV module is Pasan IIIb (Balval, Switzerland). The possible elements of the measurement uncertain that could effect electrical performance test of PV module are reference cell, spectrum correction, error from measurement repetition, test condition, stability and uniformity of artificial solar simulator. To find the measurement uncertainty, 6 men repeated the test by 10 times. And the results were that numerical average value was 124.44W and measurement uncertainty was $124.44W{\pm}0.75W$ with 95% confidence level for 125W PV module.

  • PDF

PWM 쵸퍼와 전류형 인버터를 이용한 계통연계형 태양광발전시스템 (A Utility Interactive Photovoltaic Generation System using PWM Chopper and Current Source Inverter)

  • 이승환;성낙규;오봉환;검성남;이훈구;김용주;한경희
    • 전력전자학회논문지
    • /
    • 제3권4호
    • /
    • pp.323-329
    • /
    • 1998
  • 계통연계형 태양광발전시스템을 PWM 쵸퍼와 전류형 인버터로 구성하였다. 전류형 인버터의 직류리액터를 경감하는 방법으로, 직류측에 병렬공진회로를 삽입함에 따라 맥동전력의 일부를 교류 전해콘덴서에 축적하여 직류전류의 맥동을 억제하는 방법과, 쵸퍼의 변조파를 전원주파수의 2배로 제어하여 직류전류의 맥동을 억제하는 것을 비교 검토하였다. 그리고 태양전지전류와 쵸퍼의 변조율만을 이용하여 태양전지가 항상 최대출력점에서 동작하도록 하였다. 계통과 연계함으로서 출력전력이 부하전력보다 큰 경우에는 잉영전력을 계통전원에 공급하고, 발전전력 부하전력에 대해 부족한 경우에는 계통전원이 부족분을 공급하는 것을 확인하였다.

  • PDF

Photovoltaic Properties of Poly[(9,9-dioctylfluorenyl-2,7-vinylene )-co-{2-(3'-dimethyldodecylsilylphenyl)-1,4-phenylenevinylene}] for Electro-Active Devices

  • Jin Sung-Ho;Shim Jong-Min;Jung, Seung-Jin;Kim, Sung-Chul;Naidu B. Vijaya Kumar;Shin, Won-Suk;Gal Yeong-Soon;Lee, Jae-Wook;Kim, Ji-Hyeon;Lee, Jin-Kook
    • Macromolecular Research
    • /
    • 제14권5호
    • /
    • pp.524-529
    • /
    • 2006
  • New, thermally robust, arylenevinylene conjugated polymers, including poly(9,9-dioctylfluorenyl-2,7-vinylene) [poly(FV)] and poly[2-(3'-dimethyldodecylsilylphenyl)-1,4-phenylenevinylene] [poly(m-SiPhPV)], were synthesized and used for the fabrication of efficient photovoltaic cells. Bulk heterojunction photovoltaic cells fabricated by blending one of the polymers, [poly(FV)], [poly(m-SiPhPV)], and poly(FV-co-m-SiPhPV), with the fullerene derivative [6,6]-phenyl-$C_{61}$-butyric acid methyl ester (PCBM) were found to have a power conversion efficiency of up to 0.038%..

감광성 염료를 도핑한 고분자 태양 전지 소자 연구 (Photovoltaic Effect of Polymer Solar Cells Doped with Sensitizing Dye)

  • 윤수홍;박재우;허윤호;박병주
    • 한국전기전자재료학회논문지
    • /
    • 제26권3호
    • /
    • pp.252-256
    • /
    • 2013
  • We introduced sensitizing dyes into the bulk-heterojunction (BHJ) photovoltaic (PV) layer of polymer solar cells (PSCs). The sensitizing dyes doped were Bis(tetra butyl ammonium) cis-dithio cyanato bis(2,2'-bipyridine-4-carboxylicacid-4'-carboxylate) ruthenium (II) (N719 dye) and the BHJ PV layer used was made of poly (3-hexylthiophene) (P3HT) and phenyl $C_{61}$-butyric acid methyl ester (PCBM). It was found that the N719 dyes increase the photovoltaic performance, i.e., increasing open-circuit voltage and short-circuit current density with improved fill factor. For the P3HT:PCBM PV cells doped with the N719 dyes (0.24 wt%), an increase in power conversion efficiency of 4.0% was achieved, compared to that of the control cells (3.6%) without the N719 dyes.

스팬드럴용 투광형 결정계 PV창호의 셀 간격 개구율에 따른 온도 및 발전성능 해석연구 (Temperature and Power Generation Characteristics of c-Si G/G Spandrel Window depending on Opening Ratio of PV Module)

  • 윤종호;김동수;오명환;이재범
    • 한국태양에너지학회 논문집
    • /
    • 제32권4호
    • /
    • pp.51-58
    • /
    • 2012
  • This study aims to analyze characteristics of Cell surface temperature and generated power performance for improving PV(Photovoltaic) system condition according to the cell opening ratio of transparent crystal PV system at Spandrel of curtain-wall. For this purpose, alternatives were classified for eight different cases that opening ratio of transparent crystal PV system varied from 0% to 70%, which was used by simulation tool, EnergyPlus. As results, it turned out that increasing opening ratio of transparent crystal PV system led higher PV surface temperature, back-sheet type was thus the most advantageous for decreasing surface temperature, annual generating efficiency, and annual accumulated generating power. Consequently, blocking off air space from outside insolation can advantageously keep to be better condition for generated power performance.

PV-SPE 시스템을 위한 새로운 MPPT 제어의 운전특성 분석에 관한 연구 (Analysis on Operational Characteristics of PV-SPE System by a Novel MPPT Control)

  • 최종호;이동한;김종현;김재호;박민원;유인근
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 춘계학술대회
    • /
    • pp.121-124
    • /
    • 2006
  • In the newly developed control method, the current flowing into SPE cell is the only one considerable factor. So, the structure of control circuit becomes simple and the manufacturing cost of the control device decreases. In conventional power comparison MPPT control method however, a voltage and current coming out from PV cell should be feedbacked to chase maximum power point at every moment. Then, the structure of control circuit becomes so complex and the risk of control failure is much higher than the novel MPPT control method. Therefore, PV generation system by a novel MPPT control method is especially operated much more safely in case of a huge system, because the voltage coming out from PV-cell is not needed to be feedbacked. In this paper, the PV-SPR system was actually manufactured based on the simulation model of PSCAD/EMTDC program and the results tested were shown. Authors are sure that it is the most useful method to maximize power from PV to SPE with only a feedback of SPE input current.

  • PDF

PV모듈에서 태양전지와 Interconnect회로의 구성이 I-V특성과 Hot Spot에 미치는 영향 (The effect of I-V characteristic and hot-spot by solar cell and interconnection circuit in PV module)

  • 이진섭;강기환;박지홍;유권종;안형근;한득영
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 춘계학술발표대회 논문집
    • /
    • pp.241-246
    • /
    • 2008
  • In this paper, we analyze the I-V curve and hot-spot phenomenon caused by solar cells' serial and parallel connected circuit. The mis-match loss of parallel interconnection with low Isc string decrease lower than serially interconnected one and temperature caused by hot-spot does. Also, mis-match loss of parallel interconnection with low Voc string increase more than serially interconnected one. The string having low Voc happened hot-spot phenomenon when open circuit. The bad solar cell in string gives revere bias to good solar cell and make hot-spot phenomenon. If we consider the mis-match loss, when designing PV module and array. the efficiency of PV system might increase.

  • PDF

A Dynamic Model of Single Crystalline Photovoltaic Cells Incorporating Thermo-Electric Characteristics

  • Ghods, Amirhossein;Kim, Katherine A.;Jung, Jee-Hoon
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2015년도 전력전자학술대회 논문집
    • /
    • pp.373-374
    • /
    • 2015
  • This paper proposes a dynamic thermo-electric model that links electrical parameters with thermal parameters. In this model, the irradiance and ambient temperature are used to calculate the cell temperature based on a four-layer model that includes the PV cell and surround materials. The calculated cell temperature is then used in the electrical model to accurately adjust the PV electrical characteristics. Dynamic PV characteristics, parallel capacitive and series inductive components, are added to the conventional single-diode model. The results show the effectiveness of this model rather than other conventional models of a PV panel.

  • PDF