• Title/Summary/Keyword: Photoplethysmography

Search Result 131, Processing Time 0.018 seconds

Postoperative Pain Assessment based on Derivative Waveform of Photoplethysmogram (광용적맥파 미분 파형 기반 수술 후 통증 평가 가능성 고찰)

  • Seok, Hyeon Seok;Shin, Hangsik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.7
    • /
    • pp.962-968
    • /
    • 2018
  • In this study, we developed novel indicators to assess postoperative pain based on PPG derivative waveform. As the candidate indicator of postoperative pain assessment, the time from the start of beating to the n-th peak($T_n$) and the n-th peak amplitude($A_n$) of the PPG derivative were selected. In order to verify derived indicators, each candidate indicator was derived from the PPG of 78 subjects before and after surgery, and it was confirmed whether significant changes were observed after surgery. Logistic classification was performed with each proposed indicator to calculate the pain classification accuracy, then the classification performance was compared with SPI(Surgical Pleth Index, GE Healthcare, Chicago, US). The results showed that there were significant differences(p < 0.01) in all indicators except for $T_3$ and $A_3$. The coefficient of variation(CV) of every time-related indicators were lower than the CV of SPI(30.43%), however, the CV in amplitude-related parameters were higher than that of SPI. Among the candidate indicators, amplitude of the first peak, $A_1$, showed that highest accuracy in post-operative pain classification, 68.72%, and it is 15.53% higher than SPI.

Emotion-Specific Autonomic Nervous System Responses and Patterns in Children (아동의 정서 특정적 자율신경계 반응 분석)

  • 손진훈;이정미;이경화;석지아;방석원;김경환;이미희
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2001.11a
    • /
    • pp.96-103
    • /
    • 2001
  • 그동안 정서의 실험적 유도의 어려움과 많은 제약으로 인해 성인 위주로만 이루어져 오던 정서연구가 최근 수 년 간의 정서연구에 대한 방법론의 발달로 아동에게까지 그 범위가 확대되고 있다. 본 연구에서는 아동의 다섯 가지 정서 (기쁨, 분노, 슬픔, 스트레스, 놀람)에 의해 유발되는 아동의 자율신경계 패턴을 확인하고자 한다. 놀람 정서를 추가한 "아동용 정서유발 프로토콜 (양경혜 등, 2000)"을 사용하여 아동에게 정서를 유발시키고, 정서가 유발되는 도안의 자율신경계 반응(KST, ECG, EDA, PPG)을 측정하였다. 초등학교 1, 2 학년인 34명(남: 18, 여:16)의 아동이 실험에 참여하였다. 실험 결과 다섯 가지 정서가 아동들에게 적절하고 효과적으로 유발되었으며, 정서에 따른 생리반응 변화가 관찰되었다. 분석에 사용된 12개 생리반응 변수 중 8개 변수에서 정서에 따른 차이가 발견되었으며, 정서에 따라 다른 자율신경계 반응 패턴을 얻을 수 있었다. 또한, 동일한 방법으로 수행한 본 연구실의 선행 연구와도 일치하는 결과를 보였다. 이는 아동용 정서유발 프로토콜이 표준화된 아동정서 유발자극으로 사용될 수 있으며, 생리반응 주형(template)을 이용하여 아동정서를 구분할 수 있음을 제시한다.

  • PDF

Estimation of baroreflex sensitivity using pulse arrival time rather than systolic blood pressure measurement

  • Lee, Jong-Shill;Chee, Young-Joon
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.1
    • /
    • pp.14-19
    • /
    • 2010
  • Baroreflex sensitivity (BRS) is a parameter of the cardiovascular system that is reflected in changes in pulse interval (PD and systolic blood pressure (SBP). BRS contains information about how the autonomic nervous system regulates hemodynamic homeostasis. Normally the beat-to-beat SBP measurement and the pulse interval measured from the electrocardiogram (ECG) are required to estimate the BRS. We investigated the possibility of measuring BRS in the absence of a beat-to-beat SBP measurement device. Pulse arrival time (PAT), defined as the time between the R-peak of the ECG and a single characteristic point on the pulse wave recorded from any arterial location was measured by photoplethysmography. By comparing the BRS obtained from conventional measurements with our method during controlled breathing, we confirmed again that PAT and SBP are closely correlated, with a correlation coefficient of -0.82 to -0.95. The coherence between SBP and PI at a respiration frequency of 0.07-0.12 Hz was similar to the coherence between PAT and PI. Although the ranges and units of measurement are different (ms/mmHg vs. ms/ms) for BRS measured conventionally and by our method, the correlation is very strong. Following further investigation under various conditions, BRS can be reliably estimated without the inconvenient and expensive beat-to-beat SBP measurement.

User-Adaptive Movement Noise Detection Algorithm Using Wavelet Transform (Wavelet을 이용한 사용자 적응 동잡음 판단 알고리즘)

  • Ban, Dahee;Kwon, Sungoh
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.40 no.6
    • /
    • pp.1120-1129
    • /
    • 2015
  • In this paper, we propose an algorithm to detect movement noise in PPG(Photoplethysmography) measurements. Movement noise significantly deteriorate PPG signals in measurement, so that a movement noise detection algorithm is critical before using measured PPG signals for applications such as diagnosis. To detect movement noise, we apply wavelet transform to PPG signals instead of short-time Fourier transform and decide if the measured signlas include movement noise. To that end, we adaptively choose a wavelet, which is the most similar to the subject's PPG pattern. In the case when movement noise is intentionally added in the 20% and 30% of the total experiment time, our algorithm detects time-slots including movement and outperforms previous works.

A Remote Rehabilitation System using Kinect Stereo Camera (키넥트 스테레오 영상을 이용한 원격 재활 시스템)

  • Kim, Kyungah;Chung, Wan-Young;Kim, Jong-Jin
    • Journal of Sensor Science and Technology
    • /
    • v.25 no.3
    • /
    • pp.196-201
    • /
    • 2016
  • Rehabilitation exercises are the treatments designed to help patients who are in the process of recovery from injury or illness to restore their body functions back to the original status. However, many patients suffering from chronic diseases have found difficulties visiting hospitals for the rehabilitation program due to lack of transportation, cost of the program, their own busy schedules, etc. Also, the program usually contains a few medical check-ups which can cause patients to feel uncomfortable. In this paper, we develop a remote rehabilitation system with bio-signals by a stereo camera. A Kinect stereo camera manufactured by Microsoft corporation was used to recognize the body movement of a patient by using its infrared(IR) camera. Also, we detect the chest area of a user from the skeleton data and process to gain respiratory status. ROI coordinates are created on a user's face to detect photoplethysmography(PPG) signals to calculate heart rate values from its color sensor. Finally, rehabilitation exercises and bio-signal detecting features are combined into a Windows application for the cost effective and high performance remote rehabilitation system.

A Comparative Study on the Optimal Model for abnormal Detection event of Heart Rate Time Series Data Based on the Correlation between PPG and ECG (PPG와 ECG의 상관 관계에 기반한 심박 시계열 데이터 이상 상황 탐지 최적 모델 비교 연구)

  • Kim, Jin-soo;Lee, Kang-yoon
    • Journal of Internet Computing and Services
    • /
    • v.20 no.6
    • /
    • pp.137-142
    • /
    • 2019
  • This paper Various services exist to detect and monitor abnormal event. However, most services focus on fires and gas leaks. so It is impossible to prevent and respond to emergency situations for the elderly and severely disabled people living alone. In this study, AI model is designed and compared to detect abnormal event of heart rate signal which is considered to be the most important among various bio signals. Specifically, electrocardiogram (ECG) data is collected using Physionet's MIT-BIH Arrhythmia Database, an open medical data. The collected data is transformed in different ways. We then compare the trained AI model with the modified and ECG data.

The Motion Artifact Reduction using Periodic Moving Average Filter (주기적 이동평균필터를 이용한 동잡음 제거)

  • Lee, Jun-Yeon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.17 no.4
    • /
    • pp.75-82
    • /
    • 2012
  • The Photoplethysmogram is a similar periodic signal that synchronized to a heartbeat. In this paper, we propose a periodic moving average filter that use similarity of Photoplethysmogram. This filtering method has the average value of each samples through separating the cycle of PPG signal. If there are some motion artifacts in continuous PPG signal, disjoin the signal based on cycle. And then, we made these signals to have same cycle by coordinating the number of sample. After arrange these cycles in 2 dimension, we put the average value of each samples from starting till now. So, we can eliminate the motion artifacts without damaged PPG signal.

A New Method for Unconstrained Pulse Arrival Time (PAT) Measurement on a Chair

  • Kim Ko-Keun;Chee Young-Joon;Lim Yong-Gyu;Choi Jin-Wook;Park Kwang-Suk
    • Journal of Biomedical Engineering Research
    • /
    • v.27 no.3
    • /
    • pp.83-88
    • /
    • 2006
  • A new method of measuring pulse arrival time (PAT), which is usually used for the estimation of systolic blood pressure, in an unconstrained manner using a chair, is proposed. The capacitive-coupled ECG (CC-ECG) measurement system and the air cushion with balancing tubes system were used for unconstrained PAT measurement. Firstly, the correlation between the standard PAT (S-PAT) from the photoplethysmography (PPG) and the PAT measured in an unconstrained manner (U-PAT) was evaluated. It was observed that U-PAT, which is the time delay from the R-peak of ECG to the steepest decent point of air cushion pressure wave, is significantly correlated with the S-PAT. Secondly, systolic blood pressure (SBP) measured by the radial tonometer is compared to the U-PAT. The ten-beat averaged U-PAT removed respiration effects and demonstrated a high intra-subject correlation with SBP in all participants. Finally, the tonometry SBP was estimated from these U-PAT values for one participant intermittently during half a day.

A Study on Wrist Band Type Vital Sign Acquisition Device (손목형 생체신호수집 장치에 대한 연구)

  • Kim, Hee-Hoon;Kim, Kyung-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.5
    • /
    • pp.857-861
    • /
    • 2016
  • In this study, we proposed a new method that can be measure ECG (Electrocardiography) and PPG (Photoplethysmography) in realtime on the site of the wrist for check the state of health in daily life. For convenience measurement of ECG the lead I method was used on the wrist, and omit the reference junction ECG I was measured in the right hand and the left hand of the potential difference. Then the measured electrocardiogram was amplified by the differential amplifier and the signals were passed HPF, LPF, and BPF filters. For removing the PPG's noise from the Motion artifact and temperature, we apply the reflective photoelectric volume pulse wave measurement method using green LED as a light source. The circuits was designed to be able to check the waveform using higher active amplification method at weak signals. For the validation of our device, the measured signals were compared with E2-KIT on same time. The results shows that the error does not exceed the maximum one, most of the data is confirmed to be issued Peak inspection of the same number.

A Study on Personal and Lifestyle Factors that Affects Pulse Types (개체 요인 및 생활 습관 요인이 맥상에 미치는 영향)

  • Jung, Hyun-Jung;Yun, Sang-Hun;Kang, Won-Suk
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.16 no.3
    • /
    • pp.11-22
    • /
    • 2012
  • Objectives: The aim of this study was to elucidate the relationship between pulse types measured by pulse analyzer and several factors including smoking, drinking alcohol, exercises etc. Methods: The subjects were 71 persons who were tested by oriental health examination. A self-reported questionnaire was used to gather age, smoking, drinking alcohol, exercise state and gender. The pulse types were measured by DMP 1000. The index of stress and fatigue were measured by SA 3000. We analyzed the frequency of pulse types according to gender, ages, smoking, drinking alcohol etc by chi-square test with SPSS ver. 19.0. Results: In the main pulse types, there were significant differences according to age(p<0.05) and marginal differences according to drinking alcohol(p<0.1). In the secondary pulse types, there were marginal differences according to exercise, ages. But there was no significant differences according to gender, smoking, body mass index (BMI), accelerated photoplethysmography (APG) feature, stress and fatigue. Conclusions: This study suggests that the pulse types are affected by drinking alcohol, ages, exercise.