• Title/Summary/Keyword: Photon counting system

Search Result 34, Processing Time 0.018 seconds

Development of a Wireless Gamma-ray Probe for Diagnosing and Evaluation of its Effectiveness (진단용 무선 감마선 프로브 개발 및 유용성 평가)

  • Park, Hyemin;Joo, Koansik
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.2
    • /
    • pp.173-181
    • /
    • 2015
  • We developed a wireless gamma-ray probe based on radiation photon counting method to diagnose and detect remaining lesions after surgery, and its effectiveness was evaluated using calibration sources and a phantom. The probe was designed and miniaturized using a semi-conductor-based radiation sensor, and a Bluetooth remote communication module was used to implement the wireless diagnosis and detection system. Moreover, a remote monitoring system was implemented to monitor affected areas during diagnosis and surgery. To assess the effectiveness of the developed probe in this study, calibration sources $^{57}Co$, $^{133}Ba$, $^{22}Na$ and $^{137}Cs$ and a chicken breast phantom were used. Furthermore, the probe's detection response to gamma ray was confirmed through evaluation. Its clinical applicability was verified by assessing the response linearity and detection direction according to gamma-ray intensity, as well as the detection efficiency according to the depth of the gamma source in the phantom.

Picosecond Fluorescence Lifetimes of Hematoporphyrin Derivatives in Solutions and in vitro (용액 및 시험관 실험에서의 헤마토포르피린 유도체 분자의 피코초 형광수명시간 분석)

  • Kim, Hyun-Soo;Chu, Sung-Sil;Kim, Gwi-Eon;Lee, Won-Young;Kim, Ung
    • Progress in Medical Physics
    • /
    • v.6 no.2
    • /
    • pp.61-70
    • /
    • 1995
  • The picosecond time resolved fluorescence spectra of Hematoporphyrin Derivative (HPD) in both solutions and cancer cell are measured by a time correlated single photon counting system with a synchronously mode locked dye laser. Two exoponential decay components in the fluorescence spectra were observed. The slow decay(6.3 ㎱)and the fast one(350 ㎰)are attributed to be originated from monomers and dimers, respectively. The absorption and fluorescence measurements in steady state also showed the presence of a monomeric and dimeric forms of HPD molecules. The monomer lifetime in the cancer cell was measured to be longer than that in solution, which was expected from the blue shift and narrowing of the absorption spectra for HPD-treated in vitro. The relative amplitude of the fast component was found to be enhanced in cancer cell, strongly indicating the higher affinity of the dimer for the cancer cell.

  • PDF

Measurement of the coherence time of the light from a quasi-thermal source (준열광원의 결맞음시간 측정)

  • Kim, Hyun-Oh;Ha, Yang;Shin, Jong-Tae;Kim, Tae-Soo
    • Korean Journal of Optics and Photonics
    • /
    • v.7 no.4
    • /
    • pp.341-347
    • /
    • 1996
  • The photocount distribution from a quasi-thermal light source, a moving ground glass disk (surface roughness; 9 ${\mu}{\textrm}{m}$) illuminated by a well-stabilized He-Ne laser, is measured by a photon counting system, and analyzed with theoretical calculations. The distribution approaches the Poisson distribution for the long coherence time ${\tau}_c$ compared to the measuring time T. The coherence time ${\tau}_c$ of the quasi-thermal source can be changed by controlling the velocity v of the motor driving the glass disk. By the comparison of experimental results and theory for the condition of T/ ${\tau}_c$ >>1, the coherence time ${\tau}_c$ of the quasi-thermal source is turned out to be in the range of 31.43 $mutextrm{s}$~2.48 $mutextrm{s}$ according to the circumferential velocity of the disk, and compared with the simple calculation of $\sigma$/v.

  • PDF

Comparison of Parallel and Fan-Beam Monochromatic X-Ray CT Using Synchrotron Radiation

  • Toyofuku, Fukai;Tokumori, Kenji;Kanda, Shigenobu;Ohki, Masafumi;Higashida, Yoshiharu;Hyodo, Kazuyuki;Ando, Masami;Uyama, Chikao
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.407-410
    • /
    • 2002
  • Monochromatic x-ray CT has several advantages over conventional CT, which utilizes bremsstrahlung white x-rays from an x-ray tube. There are several methods to produce such monochromatic x-rays. The most popular one is crystal diffraction monochromatization, which has been commonly used because of the fact that the energy spread is very narrow and the energy can be changed continuously. The alternative method is the use of fluorescent x-ray, which has several advantages such as large beam size and fast energy change. We have developed a parallel-beam and a fan-beam monochromatic x-ray CT, and compared some characteristics such as accuracy of CT numbers between those systems. The fan beam monochromatic x-rays were generated by irradiating target materials by incident white x-rays from a bending magnet beam line NE5 in 6.5 GeV Accumulation Ring at Tukuba. The parallel beam monochromatic x-rays were generated by using a silicon double crystal monochromator at the bending magnet beam line BL-20BM in Spring-8. A Cadmium telluride (CdTe) 256 channel array detector with 512mm sensitive width capable of operating at room temperature was used in the photon counting mode. A cylindrical phantom containing eight concentrations of gadolinium was used for the fan beam monochromatic x-ray CT system, while a phantom containing acetone, ethanol, acrylic and water was used for the parallel monochromatic x-ray CT system. The linear attenuation coefficients obtained from CT numbers of those monochromatic x-ray CT images were compared with theoretical values. They showed a good agreement within 3%. It was found that the quantitative measurement can be possible by using the fan beam monochromatic x-ray CT system as well as a parallel beam monochromatic X-ray CT system.

  • PDF