Sinusoidal A Study on the gain Stability of the Feedback Linear Pulse Amplifiers for Fast Pulse Input (금속펄스 선형증폭기의 빠른 입력펄스에 대한 이득안정도에 관한 연구)

  • 이병선
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.11 no.3
    • /
    • pp.1-14
    • /
    • 1974
  • The gain stability of the nuclear pulse linear amplifiers with feedback for such a fast pulse input as the step voltage or the nuclear radiation detector pulse is analysed in detail. The expression is derived which describes the waveform at the anode circuit of the photomultiplier tube which is a part of the nuclear radiation detector. It is analysed and compared when the feedback amplifier has one and two time-constants. When these fast input pulse voltages are applied to the feedback amplifier, the effects of feedback in linearity and stability of the output voltage appear only after two or three rise-times of the amplifier, And it is proved that in order to reduce this limitation, the rise time of the feedback amplifier shou1d be less than the input pulse width. It is also shown that the above theory can be applied directly to the voltage-shunt feedback amplifier stages designed as the basic amplifier of the linear amplifier, and that the gain stability is more improved for the smaller input impedance of this amplifier stage.

  • PDF

Application of an Energy Sensitive CZT Detector to a DXA Type of Bone Densitometer

  • Yoon, Je-Woong;Lee, Hyung-Koo;Lee, Heung-Kyu
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.422-424
    • /
    • 2002
  • The accuracy of DXA(Dual Energy X-ray Absorptiometry) highly depends on the detection and separation capability of dual energy X-ray X-ray photons. In addition both of scan time and patient exposure are affected by detection efficiency. A CZT detector with a good energy resolution and high detection efficiency was evaluated for the application of bone densitometry. Its performance was compared to a photomultiplier tube with a NaI(T1) scintillator in terms of energy resolution, detection efficiency and the accuracy of bone mineral density measurement. The comparison study was performed with CZT detector and PM tube using DXA equipments(OSTEO Plus, OSTEO Prima, ISOL Technology). The energy spectrum was acquired using MCA(Multi-Channel Analyzer). The used X-ray energy ranged from 20keV to 86keV. The MCA result of the CZT detector showed a slightly sharper energy spectrum than that of NaI(T1). Detection efficiency of the CZT detector at 59.5keV was 1.4 times better. Remarkably the final results of bone mineral density measurements demonstrate only less than 1% difference. The CZT detector appears to have many benefits for the application of bone densitometry. Its excellent energy resolution can enhance the counting accuracy of dual energy X-ray spectrum. Furthermore its compactness in physical dimension and no cooling requirement will be additional benefits for a more compact and accurate bone densitometer.

  • PDF

Fabrication of Fiber-optics Detector for Measuring Radioactive Waste (방사성 오염도 측정을 위한 광섬유 검출기 제작)

  • Kim, Jeong-Ho;Joo, Koan-Sik
    • Journal of IKEEE
    • /
    • v.19 no.3
    • /
    • pp.282-287
    • /
    • 2015
  • In this study, an optical fiber detector was constructed by using a Ce:GAGG scintillator, optical fiber, and photomultiplier. The single crystal size of the scintillator was set to $3{\times}3{\times}20mm^3$ after simulating the counting efficiency of gamma rays in the scintillator by using the MCNPX code. The constructed detector used the standard gamma ray sources $^{137}Cs$ and $^{133}Ba$ to measure radiation and analyze the spectral characteristics of gamma rays. The resulting trend curve showed excellent linearity with an R-squared value of 0.99741, and the detector characteristics were found to vary 2% or less with distance based on comparison with the MCNPX value. Furthermore, the spectroscopic analysis of the gamma ray energy from the single-ray and mixed-ray sources showed that $^{137}Cs$ had its peak energy at 662 keV, and $^{133}Ba$ had at 356 keV. It seems that if the fiber-optics detector is used, working hours and exposure of worker can be reduced.

MgO 표면을 diamond stylus로 마모시킬 때 발생되는 전자와 광자 방출에 관한 연구

  • 황도진;김종민;김명원
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.198-198
    • /
    • 1999
  • 본 연구는 진공상태에서 단단한 물질로 된 diamond stylus로 단결정 MgO 표면에 마모(abrasion)가 할 때 발생되는 Photon emission(PHE), electron emission(EE), 마찰력을 시간의 함수로 동시에 측정하였다. 마모가 일어나는 동안 PHE 와 EE을 시간의 함수로 측정하면 마찰력 신호(signal)와 일치하지 않고 강한 fluctuation을 보여주고 있다. 마모를 가할 때 PHE와 EE의 signal은 wear 실험이 지속되는 동안은 force signal과 관계가 있다. 그러나 변형과 마찰력의 시간의 함수에는 관계하지 않음을 알 수 있다. 본 실험에서 사용된 실험장치는 PhE, EE, frictional force을 동시에 실할 수 있는 장치이다. 광자방출 실험은 공기 중에서도 할 수 있으나 전자방출은 진공에서 얻을 수 있으므로 1$\times$10-4pa하에서 실험하였다. 전자방출은 Channel electron multiplier(bias-100V)로 검출하였고, 광자 에너지는 Gencom photomultiplier를 사용하여 180~600nm의 photon을 측정하였다. 마모는 탐색기에 관계되는 접촉점의 움직임에 관계없이 실험하였다. 시료의 처리과정과 load속도에 따른 PhE, EE, data의 방출은 시료의 표면 상태에 따라 좌우되었다. cleaved 표면은 polished 표면보다 강한 emission을 나타내었다. 이것은 마찰이 표면 상태에 의존됨을 볼 수 있었다. 속도에 따라 emission이 증가하다가 ~0.5m/s이상에서 포화상태에 도달하였다. emission 측정은 열처리한 시료와 열처리 안한 시료를 비교하였다. 발광도(luminescence)는 주로 변형(deformation)에 의해 생겼으며, 전자 방출은 벽개(fracture)에 의해 발생됨을 알 수 있었다. 측정한 3개의 signal을 시간에 따라 분석하면 stick-slip-like 현상을 볼 수 있었다. 이것으로 보아 stick은 변형에 의해 생기고 ms 후에 벽개 현상이 발생됨을 볼 수 있다. 이러한 방출 현상은 마모시 일어나는 세라믹의 급격한 벽개 과정을 이해하는 데 많은 도움을 주었다. PhE와 EE signal은 다이아몬드 stylus로 단결정 MgO 기판에 마모를 가할 때 ms 단위로 검출 할 수 있었다. 방출과 마찰력은 표면조건, load, stylus velocity에 따라 변하였다. 마찰력, PhE, EE의 시간에 따른 분석에서 PhE는 변형 과정에 민감하며, EE는 stylus velocity에 의존하였다. 본 연구의 MgO 마찰 실험에서 표면 변화에 대한 정보를 얻을 수 있었다.

  • PDF

Feasibility Study of Source Position Verification in HDR Brachytherapy Using Scintillating Fiber

  • Moon, Sun Young;Jeong, EunHee;Lim, Young Kyung;Chung, Weon Kyu;Huh, Hyun Do;Kim, Dong Wook;Yoon, Myonggeun
    • Progress in Medical Physics
    • /
    • v.27 no.4
    • /
    • pp.213-219
    • /
    • 2016
  • The position verification of the radiation source utilized in brachytherapy forms a critical factor in determining the therapeutic efficiency. Currently, films are used to verify the source position; however, this method is encumbered by the lengthy time interval required from film scanning to analysis, which makes real-time position verification difficult. In general, the source position accuracy is usually tested in a monthly quality assurance check. In this context, this study investigates the feasibility of the real-time position verification of the radiation source in high dose rate (HDR) brachytherapy with the use of scintillating fibers. To this end, we construct a system consisting of scintillating fibers and a silicon photomultiplier (SiPM), optimize the dosimetric software setup and radiation system characteristics to obtain maximum measurement accuracy, and determine the relative ratio of the measured signals dependent upon the position of the scintillating fiber. According to the dosimetric results based on a treatment plan, in which the dwell time is set at 30 and 60 s at two dwell positions, the number of signals is 31.5 and 83, respectively. In other words, the signal rate roughly doubles in proportion to the dwell time. The source position can also be confirmed at the same time. With further improvements in the spatial resolution and scintillating fiber array, the source position can be verified in real-time in clinical settings with the use of a scintillating fiber-based system.

The Change of Biophoton Emission on Acupuncture Stimulus and Environment Condition in Healthy Volunteers (환경조건 및 침자극에 따른 인체 생물 광자 방출량 변화에 관한 연구)

  • Ryu, Yeon-Hee;Jung, Sang-Yong;Hwang, Hye-Suk;Kim, Yoo-Sung;Lee, Young-Seop;Yang, Eun-Jin;Choi, Sun-Mi
    • Korean Journal of Oriental Medicine
    • /
    • v.14 no.2
    • /
    • pp.35-39
    • /
    • 2008
  • Objective: Recently biophysical research has shown very weak radiation of photons in plant, animal and human cells. Biophoton emission of the aliving system has received specific phenomena because of its scientific potential for monitoring metabolism to human body. This paper proposes a new challenge possibility of the biophoton emission in biophysiological human condition index. Method: Biophoton emission were measured with twenty one healthy volunteers. The study analyses existence for the effect of specific acupoint stimulus, exposure to the sun and low temperature in healthy volunteers. Two photomultiplier tubes which spectral range was from 300 nm to 650 nm was used for the detection of biophoton emission observation of possible acupuncture stimulation effect at left hand palm. Result: There was a reversion of relative emission rates from the palms affected the environment condition. Otherwise, when the acupuncture stimulation, the emission rate was not enough significantly change(p<0.05). Conclusion: In this study, biophoton emissions depend on the environment condition for all subjects. Measurments with the biophoton emission rate analysis might be much considered in future studies.

  • PDF

Development of a Small Gamma Camera Using NaI(Tl)-PSPMT or Breast Imaging (NaI(Tl) 섬광결정과 위치민감형 광전자증배관을 이용한 유방암 진단용 소형 감마카메라 개발)

  • Kim, J.H.;Choi, Y.;Kwon, H.S.;Kim, H.J.;Kim, S.E.;Choe, Y.S.;Kim, M.H.;Joo, K.S.;Kim, B.T.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.365-368
    • /
    • 1997
  • We are developing a small gamma camera or imaging malignant breast tumors. The small scintillation camera system consists of NaI(Tl) crystal ($60\;{\times}\;60\;{\times}\;6\;mm^3$) coupled to position sensitive photomultiplier tube (PSPMT), nuclear instrument module (NIM), analog to digital converter (ADC), and personal computer. High quality flood source image and hole mask image were obtained using the gamma camera developed in this study. Breast phantom containing $2{\sim}7\;mm$ diameter spheres was successfully imaged with parallel hole collimator. The obtained image displayed accurate activity distribution over the imaging field of view. Linearity and uniformity correction algorithms are being developed. It is believed that the developed small gamma camera could be useful or detection of malignant breast cancer.

  • PDF

Fabrication and Characterization of a Fiber-Optic Alpha/Beta Detector for Nuclear Medicine Application (핵의학 적용을 위한 광섬유 기반의 알파/베타 검출기의 제작 및 특성분석)

  • Hong, Seung-Han;Yoo, Wook-Jae;Shin, Sang-Hun;Seo, Jeong-Ki;Han, Ki-Tek;Jeon, Da-Yeong;Cho, Seung-Hyun;Lee, Bong-Soo
    • Journal of Sensor Science and Technology
    • /
    • v.21 no.5
    • /
    • pp.367-373
    • /
    • 2012
  • We fabricated a fiber-optic alpha/beta detector, which is composed of a sensing probe, a plastic optical fiber, a photomultiplier tube, and a multichannel analyzer, to obtain the energy spectra of radioactive isotopes. As inorganic scintillators of a sensing probe, a ZnS(Ag) film was coupled with a $CaF_2$(Eu) crystal for alpha and beta spectroscopy. In this study, $^{210}Po$ and $^{90}Sr$ were used as alpha and beta sources, respectively, and we measured the radiation energy spectra using a fiber-optic alpha/beta detector to identify alpha and beta emitting radionuclides for nuclear medicine application. Also, the variations of energy spectrum were obtained according to the length of plastic optical fiber.

Development of a Coded-aperture Gamma Camera for Monitoring of Radioactive Materials (방사성 물질 감시를 위한 부호화 구경 감마카메라 개발)

  • Cho, Gye-Seong;Shin, Hyung-Joo;Chi, Yong-Ki;Yoon, Jeong-Hyoun
    • Journal of Radiation Protection and Research
    • /
    • v.29 no.4
    • /
    • pp.257-261
    • /
    • 2004
  • A coded-aperture gamma camera was developed to increase the sensitivity of a pin hole camera made with a pixellated CsI(Tl) scintillator and a position-sensitive photomultiplier tube. The modified round-hole uniformly redundant array of pixel size $13{\times}11$ was chosen as a coded mask considering the detector spatial resolution. The performance of the coded-aperture camera was compared with the pin hole camera using various forms of Tc-99m source to see the improvement of signal-to-noise ratio or the improvement of the sensitivity. The image quality is much improved despite of a slight degradation of the spatial resolution. Though the camera and the test were made for low energy case, but the concept of the coded-aperture gamma camera could be effectively used for the radioactive environmental monitoring and other applications.

Fabrication and Characterization of a Fiber-optic Radiation Sensor for Detection of Tritium (삼중수소 검출용 광섬유 방사선 센서의 제작 및 특성분석)

  • Jang, Kyoung-Won;Cho, Dong-Hyun;Yoo, Wook-Jae;Lee, Bong-Soo;Moon, Joo-Hyun;Park, Byung-Gi;Cho, Young-Ho;Kim, Sin
    • Korean Journal of Optics and Photonics
    • /
    • v.20 no.4
    • /
    • pp.201-206
    • /
    • 2009
  • In this study, we have fabricated a fiber-optic radiation sensor for detection of tritium using inorganic scintillators and optical fibers. We have tested various kinds of inorganic scintillators such as $Gd_2O_2S$ : Tb, $Y_3Al_5O_{12}$ : Ce, and CsI : Tl to select the most effective sensor tip. In addition, we have measured the scintillating lights using a photomultiplier tube as a function of distance between sensor tips to the source with the different activities of hydride tritium. The final results are compared with those which are obtained using a surface activity monitor.