• 제목/요약/키워드: Photodiode

검색결과 532건 처리시간 0.195초

유전 알고리즘을 이용한 다중 양자 우물 구조의 갈륨비소 광수신소자 공정변수의 최적화 (Optimization of Device Process Parameters for GaAs-AlGaAs Multiple Quantum Well Avalanche Photodiodes Using Genetic Algorithms)

  • 김의승;오창훈;이서구;이봉용;이상렬;명재민;윤일구
    • 한국전기전자재료학회논문지
    • /
    • 제14권3호
    • /
    • pp.241-245
    • /
    • 2001
  • In this paper, we present parameter optimization technique for GaAs/AlGaAs multiple quantum well avalanche photodiodes used for image capture mechanism in high-definition system. Even under flawless environment in semiconductor manufacturing process, random variation in process parameters can bring the fluctuation to device performance. The precise modeling for this variation is thus required for accurate prediction of device performance. The precise modeling for this variation is thus required for accurate prediction of device performance. This paper will first use experimental design and neural networks to model the nonlinear relationship between device process parameters and device performance parameters. The derived model was then put into genetic algorithms to acquire optimized device process parameters. From the optimized technique, we can predict device performance before high-volume manufacturign, and also increase production efficiency.

  • PDF

The Implementation of The Multi-Subject, Multi-Channel Optical Telemetry System for Physiological Signals

  • 박차훈;박종대;서희돈
    • 센서학회지
    • /
    • 제9권6호
    • /
    • pp.448-454
    • /
    • 2000
  • This paper describes the implementation of a multi-subject, multi-channel optical telemetry system for the short range measurement of electrocardiograms (EKGs) a system which receives command signals and transmits physiological signals to the external system using LED (Light Emitting Diode) and PD (Photodiode). This system decreases the dependency of power supply voltage to the CMOS IC chips and a new enforced synchronization technique using infrared bi-directional communication has also been proposed. The telemetry IC with the size of $5.1{\times}5.1mm^2$ has the following functions: receiving of command signal, initialization of internal state of all functional blocks, decoding of subject selection signal, time division multiplexing of 4-channel modulated physiological signals, transmission of modulated signals to external system, and auto power down control.

  • PDF

Laser Weld Quality Monitoring System

  • Park, H.;Park, Y.;S. Rhee
    • International Journal of Korean Welding Society
    • /
    • 제1권1호
    • /
    • pp.7-12
    • /
    • 2001
  • Real time monitoring has become critical as the use of laser welding increases. Plasma and spatter are measured and used as the signal for estimating weld quality. The estimating algorithm was made using the fuzzy pattern recognition with the area of data that is beyond the tolerance boundary. Also, an algorithm that detects the spatter and the localized defect was created in order to kd the partially produced pit and the sudden loss of weld penetration. These algorithms were used in quality monitoring of the $CO_2$ laser tailored blank weld. Statistical program that can display the laser weld quality result and the signal transition was made for the first stage of the remote control system.

  • PDF

광센서를 이용한 레이저용접공정 모니터링 (Process Monitoring in Laser Welding with Photodiodes)

  • 방세윤;윤충섭
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1996년도 추계학술대회 논문집
    • /
    • pp.474-478
    • /
    • 1996
  • Process monitoring in laser welding is essential for automation and quality control of products. Various signals from laser welding, such as plasma, sound, optical signals, etc., are utilized for monitoring the process and detecting abnormal weld conditions. In this study, both W light from plasma formed above the weld pool and IR signal from the melting pool are detected with photodiodes and PC-based A/D board, and analyzed to give a guidance about the weld quality. Experimental results show the possibility of using the signals for predicting and evaluating the weld qualify and adapting into the system for on-line process monitoring.

  • PDF

펄스형 레이저 거리측정기를 위한 거리계산 카운터 개발

  • 유병헌;조성학;장원석;김재구;황경현
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2004년도 춘계학술대회 논문요약집
    • /
    • pp.180-180
    • /
    • 2004
  • 정밀한 계측의 필요성이 높아지면서 레이저는 그 신뢰성과 사용 편의성으로 인해 거리측정에도 높은 활용을 보이고 있다. 레이저 거리측정기(laser range finder, LRF)의 원리는 20ns 미만의 짧은 레이저 펄스를 표적에 발사한 후 반사되어 돌아오는 신호의 시간과 빛의 속도를 곱하여 거리를 계산하는 방식이다. 이러한 반사펄스(pulse-echo techniques)법은 수m-수백만 km까지의 거리측정에 사용되는 방식으로서 정밀하고 빠른 측정이 가능할 뿐 아니라 단지 목표물을 확인하고 측정버튼을 누름으로써 결과를 얻을 수 있는 사용 편의성을 장점으로 한다.(중략)

  • PDF

Detection of Toxic Heavy Metal, Co(II) Trace via Voltammetry with Semiconductor Microelectrodes

  • Ly, Suw Young;Lee, Chang Hyun;Koo, Jae Mo
    • Toxicological Research
    • /
    • 제33권2호
    • /
    • pp.135-140
    • /
    • 2017
  • The cobalt (Co(II)) ion is a main component of alloys and considered to be carcinogenic, especially due to the carcinogenic and toxicological effects in the aquatic environment. The toxic trace of the Co(II) detection was conducted using the infrared photodiode electrode (IPDE) using a working electrode, via the cyclic and square-wave anodic stripping voltammetry. The results indicated a sensitive oxidation peak current of Co(II) on the IPDE. Under the optimal conditions, the common-type glassy carbon, the metal platinum, the carbon paste, and the carbon fiber microelectrode were compared with the IPDE in the electrolyte using the standard Co(II). The IPDE was found to be far superior to the others.

살충제 Imidacloprid 잔류물의 신속한 측정을 위한 생물반응 및 계측제어 시스템 개발 (Development of a Biological Reaction and Measurement Control System for Rapid Detection of the Insecticide Imidacloprid Residues)

  • 임종근;조한근
    • Journal of Biosystems Engineering
    • /
    • 제30권2호
    • /
    • pp.114-120
    • /
    • 2005
  • In this study, a biological reaction and measurement control system was developed to rapidly measure the insecticide imidacloprid residues in agricultural products. The biological reaction part of the system was designed to include micro-pumps and valves for fluid transport, and a polystyrene covet as a reaction chamber. The measurement control part of the system consisted of a photodiode with a light-emitting diode for optical density measurement, and a control microcomputer to implement assay. Signal output was read as the rate of change in optical density at 645 nm. The sensitivity of the system was 2.2 ng/mL ($IC_50$). The system could execute a measurement cycle in about 19 minutes. Research will be continued to develop an automatic sampler fur imidacloprid residues from agricultural products.

무선광 연결에서 솔라 셀을 이용한 잡음광 소거 (Optical Noise Reduction using a Solar Cell in a Wireless Optical Interconnection)

  • 이성호
    • 한국전자파학회논문지
    • /
    • 제14권4호
    • /
    • pp.336-342
    • /
    • 2003
  • 본 논문에서는 잡음광의 영향이 심한 환경에서 솔라 셀을 이용하여 잡음광에 의한 저주파 간섭을 소거하는 동시에 강한 잡음광을 수신부의 전원으로 활용할 수 있는 차동검출기를 새로이 소개한다. 솔라 셀에서 검출되는 DC전압을 수신부의 전원으로 사용하고, AC전압을 이용하여 차동검출방식으로 포토다이오드의 잡음전압을 소거함으로써 신호대잡음비가 약 20 dB 개선되었다.

펄스레이저 및 광다이오드를 이용한 변압기 절연유의 절연감시법 (Monitoring method of transformer insulationg oil using pulsed-laser and photodiode)

  • 조정수;양동민;안광선;윤성호;김희제
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2130-2132
    • /
    • 1999
  • This paper is research for the practicability of instrument which can apply to the transformer on the spot with the criteria of insulation oil with the method of measuring the volume of $H_2O$ in the insulation oil by playing insulation oil with the significant role for precaution diagnosis on breakdown of transformer among power system into Nd:YAG laser.

  • PDF

Implementation of Non-Contact Gesture Recognition System Using Proximity-based Sensors

  • Lee, Kwangjae
    • 반도체디스플레이기술학회지
    • /
    • 제19권3호
    • /
    • pp.106-111
    • /
    • 2020
  • In this paper, we propose the non-contact gesture recognition system and algorithm using proximity-based sensors. The system uses four IR receiving photodiode embedded on a single chip and an IR LED for small area. The goal of this paper is to use the proposed algorithm to solve the problem associated with bringing the four IR receivers close to each other and to implement a gesture sensor capable of recognizing eight directional gestures from a distance of 10cm and above. The proposed system was implemented on a FPGA board using Verilog HDL with Android host board. As a result of the implementation, a 2-D swipe gesture of fingers and palms of 3cm and 15cm width was recognized, and a recognition rate of more than 97% was achieved under various conditions. The proposed system is a low-power and non-contact HMI system that recognizes a simple but accurate motion. It can be used as an auxiliary interface to use simple functions such as calls, music, and games for portable devices using batteries.