• Title/Summary/Keyword: Photo Diode

Search Result 256, Processing Time 0.038 seconds

Aqueous Glucose Solution Measurement by Three Types NIR Spectrometer (세 가지 방식의 근적외선 분광분석기를 이용한 글루코오스 수용액의 측정)

  • 백주현;강나루;우영아;김효진
    • YAKHAK HOEJI
    • /
    • v.47 no.6
    • /
    • pp.461-468
    • /
    • 2003
  • A method is described for measuring clinically relevant levels of glucose in a pH 7.4 phosphate buffer by nearinfrared (NIR) absorption spectroscopy. Three types of NIR spectrometer, dispersive type, photo-diode array (PDA) type, and fourier transform (FT) type spectrometer were used and the performance was compared. Spectra were collected with a cuvette cell or quartz liquid fiber of 1 mm or 2 mm optical pathlength as transmittance method. Glucose absorption band appeared at second overtone, first overtone, and combination region for all systems. By use of the multivariate technigue of partial least squares (PLS) regression, glucose concentrations can be determined with a 16, 44, and 9.1 mg/d l standard error of prediction for dispersive type, photo-diode array type, and fourier transform type system, respectively. Sensitivity of spectrometer was evaluated by absorbance for the difference of 10 mg/d l glucose. Three absorption bands, second overtone, first overtone, and combination region were suited to three types systems, dispersive type, photo-diode array type, and fourier transform type systems, respectively. This investigation showed that three types NIR spectrometer were proper method for identification and quantitative analysis of glucose and possible for noninvasive blood glucose monitoring.

Small Particle Detection System by Optical Scattering Effect (광 산란특성을 이용한 미세입자 감지시스템)

  • Kim, Eung-Soo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.7 no.3
    • /
    • pp.579-583
    • /
    • 2012
  • We have designed the small particle detection system. The scatteing effect of light was used to detect small particle. The fabricated system consisted of laser diode, lens, pin hole, and photo detector. The aperture, lens, and photo detector were optimized to improve the performance of detection system. The fabricated detection system detected the scattered light by small particle entering into detection system and its response time was fast.

TIG Welding Process Monitoring using Photo Diode (광소자를 이용한 TIG 용접 가공의 모니터링)

  • 장욱진;김재도
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.04b
    • /
    • pp.383-388
    • /
    • 1995
  • The ARC light has been measured using photo-detect system under different TIG welding condition. Light detect system consists of photo diode, ND Filter, OP Amp. A/D convertor and PC. The purpose of this experiment is to show the relationship between ARC light and process variables such as welding current, torch travel speed, etc. The results can be applied to estimate the condition of welding process and the quality of welding products. The signal of ARC light has periodic patterns in good TIG welding condition whereas in abnormal condition the signal has different pattern. Amount of Ar shielding gas and distance from electrode to specimen affect the signal pattern significantly.

  • PDF

Small Methane Detection System using Optical Spectrum Characteristics (분광특성을 이용한 소형의 메탄 가스 감지 시스템)

  • Jo, Kyung-Hwa;Lyu, Geun-Jun;Kim, Eung-Soo
    • Journal of Sensor Science and Technology
    • /
    • v.20 no.1
    • /
    • pp.53-57
    • /
    • 2011
  • We developed a small methane detection system because methane gas is used in many areas and is dangerous. The developed system consisted of LD(Laser Diode) tuned a wavelength of $1.65\;{\mu}m$, two mirrors to collect a laser beam, photo detector. It could detect methane gas at a long range and its sensitivity was 1.98 V/$CH_4%$.

A study on underwater optical wireless communication link capability in the Bay of Bengal

  • Sathyaram, V.;Prince, Shanthi;Vedachalam, N.
    • Ocean Systems Engineering
    • /
    • v.8 no.1
    • /
    • pp.33-39
    • /
    • 2018
  • The paper presents a numerical underwater channel model developed in MATLAB for estimating the optical link budget between a light emitting diode (LED) based optical transmitter and a photo diode (PD) receiver when operated in the harbor, coastal and deep waters locations in the Bay of Bengal. The water samples are collected at different locations in the Bay of Bengal using a water sampler during an offshore research cruise. The optical attenuation, the main inherent parameter determining the range of the optical communication link is identified for the different waters using an underwater irradiance measurement system in the laboratory. The identified parameters are applied to the numerical model and found that a 10 W LED and a photo diode based system can provide the optical budget required for a horizontal underwater communication range of about 0.5, 14 and 35 m in the harbor, coastal and deep waters locations respectively. By increasing the transmitter power to 50 W, the operating range of the communication link could be increased up to 53 m in deep water locations in the Bay of Bengal.

Antimicrobial Photodynamic Therapy on Pseudomonas aeruginosa Using a Diode Laser and PhotoMed, Methyl Pheophorbide A, or Radachlorin® (다이오드 레이저와 PhotoMed, Methyl Pheophorbide A, Radachlorin®을 이용한 녹농균에 대한 항균 광역학 요법)

  • Young-Kyu SONG;Keun-Dol YOOK;Ji-Won KIM
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.56 no.1
    • /
    • pp.52-58
    • /
    • 2024
  • Photodynamic therapy (PDT) activates intracellular oxygen using a photosensitizer activated by light of a specific wavelength and is a potential means of treating wound infections caused by antibiotic-resistant bacteria. Pseudomonas aeruginosa (P. aeruginosa) is typically non-pathogenic in healthy individuals but can induce severe illnesses like sepsis in the immunocompromised. Antibiotics have been conventionally used to treat P. aeruginosa infections, but increasing antibiotic resistance caused by drug misuse poses a growing challenge to the management of these infections. This study aimed to investigate the ability of PDT using photosensitizers (PhotoMed, Methyl pheophorbide A, or Radachlorin®) and a diode laser to inhibit P. aeruginosa. Suspensions of P. aeruginosa and a photosensitizer were inoculated into Petri dishes and incubated for 30 minutes. Samples were then irradiated with the laser at 3 J/cm2, and after incubation, colony areas were measured. P. aeruginosa killing rates were 79.65% for PhotoMed, 47.36% for Methyl pheophorbide A, and 40.91% for Radachlorin®. This study shows that PDT using a diode laser and a photosensitizer constitutes an effective practical therapeutic approach for inhibiting P. aeruginosa.

Geometric error assessment system for linear guideway using laser-photodiodes (레이저-수광소자를 이용한 선형 이송측의 기하학적 오차측정 시스템)

  • Pahk, H.J.;Chu, C.N.;Hwang, S.W.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.11 no.5
    • /
    • pp.180-188
    • /
    • 1994
  • Error assessment and evaluation for machine for machine tool slides have been considered as essential tools for improving accuracy. In this paper, a computer aided measurement technique is proposed using photo pin diodes of quadrant type and laser source. In thedeveloped system, three photo diodes are mounted on a sensor mounting table, and the sensored signal is processed by specially designed signal conditioner to give fine resolution with minimum noise. A micro computer inputs the processed signal, and the geometric errors of five degree of freedoms are successfully evaluated. Pitch, roll, yaw, vertical and horizontal straightness errors are thus assessed simultaneously for a machine tool slide. Calibration techniques such as optics calibration, photo diode calibration are proposed and implemented, giving precise calibration for the measurement system. The developed system has been applied to a practical machine tool slide, and has been found as one of efficient and precise technique for machine tool slide.

  • PDF

Measurement of Micro Thermal Deformation of Optical Pick-up Base Using Holographic Interferometry (흘로그램 간섭계를 이용한 광픽업 베이스의 미소 열변형 측정)

  • 서영민;강신일
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.191-194
    • /
    • 2002
  • In optical pick-up, optical components such as objective lens, collimator, mirror, laser diode and photo diode are mounted on the pick-up base. These components must keep their original position during operation for proper transmittance of information from laser diode to optical disk and back to photo diode. However, micro thermal deformation of pick-up base which is induced by thermal environment during operation can deteriorate the performance of optical pick-up. Therefore, it is important to measure and analyze the thermal deformation behavior of pick-up base under thermal environment. In the present study, a measurement system using holographic interferometry was designed to measure micro thermal deformation of pick up base. The measurement system was verified by using the deformation of cantilever with prescribed motion actuated by PZT with 1 nm resolution. Interferometric measurement was compared quantitatively with that induced by PZT actuator. Finally, micro thermal deformation of pick-up base under actual thermal environment was measured using the present holographic interferometry and the results were analysed.

  • PDF

Effect of Particle Contamination of Objective Lens in a CD-ROM Drive on Laser Diode Power and Photo Diode RE Signal (CD-ROM 드라이브의 대물렌즈 입자오염이 레이저 다이오드 파워와 포토 다이오드 RF 신호에 미치는 영향)

  • Pae, Yang-Il;Lee, Jae-Ho;Hwang, Jung-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.1
    • /
    • pp.66-71
    • /
    • 2004
  • Airborne contaminant particles are intruded into optical disk drive(ODD) due to the flow caused by disk rotation and can be adhered to objective lens, which causes read/write errors. Such a phenomenon can be a serious problem for high-density storage devices. The purpose of this paper is to understand the effect of particle contamination of objective lens in a CD-ROM drive on laser diode power and photo diode RF signal. The measurements of laser power and readout RF signal were carried out by using a laser power meter and a time interval analyzer, respectively. The parameters for estimating a readout-signal' distortion were its jitter and amplitude. Alumina(Al$_2$O$_3$) particles were used as test dust particles. The results show that the failure for data access happened as the degree of lens contamination was greater than 20%.

Fabrication and characteristic evaluation of microfluidics chip integrated OLED for the light sources (OLED광원이 집적화된 마이크로 플루이딕칩의 제작 및 특성 평가)

  • Kim, Young-Hwan;Han, Jin-Woo;Kim, Jong-Yeon;Kim, Byoung-Yong;Seo, Dae-Shik
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.377-377
    • /
    • 2007
  • A simplified integration process including packaging is presented, which enables the realization of the portable fluorescence detection system. A fluorescence detection microchip system consisting of an integrated PIN photodiode, an organic light emitting diode (OLED) as the light source, an interference filter, and a microchannel was developed. The on-chip fluorescence detector fabricated by poly(dimethylsiloxane) (PDMS)-based packaging had thin-film structure. A silicon-based integrated PIN photo diode combined with an optical filter removed the background noise, which was produced by an excitation source, on the same substrate. The active area of the finger-type PIN photo diode was extended to obtain a higher detection sensitivity of fluorescence. The sensitivity and the limit of detection (LOD S/N = 3) of the system were $0.198\;nA/{\mu}M$ and $10\;{\mu}M$, respectively.

  • PDF